Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 CrAccepted-AOC S4018 NO 5 KATHIRESAN STREET GNANAMURTHY NAGAR AMBATTUR CHENNAI 600 053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | ₹19.9 Cr | L1 | Accepted-AOC Technically Qualified and Financially accepted |
| 2 | Rejected-Technical COIMBATORE | COIMBATORE | TAMIL NADU | 641001 | - | - | Rejected-Technical Technically Disqualified |
Tender Value
Refer Docs
EMD Value
₹18.5 L
Closing Date
6 Jul 2023, 5:00 pmClosed
GM (S and T/RS and E)
Kochi Metro Rail Ltd, 4th Floor, JLN Stadium Metro Station, Kaloor, Kochi - 682 017
Development/Improvement of Non-Motorised Transport (NMT) Initiatives of Kochi Metro Rail Ltd. Package B (Electrical Works) - Manorama junction to SN junction
2023_KMRL_581979_1
KMRL/PROC/TENDER/2023-24/021
Open Tender
Marine Works
240 days
Kochi
Please refer Tender documents.
21 documents required · 21 mandatory
₹23,600
₹18.5 L
Yes
Kochi Metro Rail Limited
31 Aug 2023
15 Jun 2023
10 Jul 2023
15 Jun 2023
6 Jul 2023
29 Jun 2023
15 Jun 2023 - 26 Jun 2023
22 Jun 2023
Amount
SCHEDULE- A Electrical Street Light Works
RCC Foundation for Lighting Pole including excavation in all type of soil,shuttering works , reinforcement , backfilling and restoation of the same (unit in cubic meter). Foundation: adequate size M20 grade RCC foundation with Raft including excavation , backfilling ,including erection of foundation bolts and restoration of the same shall be done by the contractor. The pedestal has to be provided with 63 mm dia HDPE pipe for looping in and out of cable. The item includes the excavation by mechanical means (hydraulic excavator)/manual means including disposal of excavated earth, disposed earth to be levelled and neatly dressed, in all kinds of soil.Contractor/Pole manufacturer shall submit design calculation in support of size of RCC foundation for external lighting poles for approval.
Supply, Erection, Testing and commissiong of square type Lighting pole. Upper arm length shall be min 1100mm and lower arm length shall be min 700 mm. Square Lighting pole asymmetrical Arm – 7 meter total height .The upper arm 6.4 meter and second arm at 5 meter. Pole has a built-in control box with service door including lock and safety chain. Dimension of Square type lighting pole 100mm x 100mm x 2.5mm thick and height of 7000 mm. Pole shall be coated with epoxy zinc phosphate primer of 40 microns and finished using environmentally stable polyurethane based paint of 40 microns. Pole with base plate GI of dimension 300mm x300mm x 16mm thick. Wind speed consideration in pole design shall be minimum 50 m/sec. Steel of grade YSt 210 to IS 4923:1997 in galvanized condition to be used for manufacturing square hollow sections. Steel used for manufacturing base plate is of Grade E250 to IS 2062:2011 in galvanized condition and foundation bolt is of Grade 5.6 in galvanized condition. Pole is hot dip galvanized to 80 microns to IS 2629:1985 / IS 4759:1996 / IS 2633:1986. The pole shall include 4 Nos. of hot dip galvanized M20 x 500mm foundation bolts. The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree / equivalant MCB, terminal connectors for loop-in loop-out arrangement suitable of terminating aluminium armoured cables up to 25 Sq.m size. The pole shall be integrated with LED module of 60W and 30W. The luminaire shall have an Integral power supply along with an earth connection and 10KV surge protection. - Luminaire shall be pre-wired. The pole shall be with foundation bolt, fittings, internal cabling, painting and printing of KMRL logo on Poles by consultation with KMRL.Pole shall include a support structures of advertisement board and Dimension of support structure 500mmx500mmx1000mm. The support structures of advertisment board shall adjustable type. The LED luminaire shall meet the following details. System Lumens: Min 7000 Lumens for 60 w and 4000 lumens for 30W, Luminaire Efficacy: 120 Lumen/Watt or above , CCT: 4000K, CRI: 70,a driver with surge protection of 10/10 kv, THD<=15%, PF:>=0.95, Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP66 rating (Refer Annexure-VII for drawing)
Supply, Erection, testing & Commissioing of square cross section pole and 35W/ 40W LED with the following details. Total height of the pole shall be 3.5 metre.Pole has a built-in control box with service door including lock and safety chain. The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree or equivalent make MCB, terminal connectors for loop-in loop-out arrangement. Dimension of Square type cross section lighting pole 100mm x 100mm x 2.5mm thick and height of 3500 mm. Pole shall be coated with epoxy zinc phosphate primer of 40 microns and finished using environmentally stable polyurethane based paint of 40 microns. Pole with base plate GI of dimension 300mm x300mm x 16mm thick. Wind speed consideration in pole design shall be minimum 50 m/sec. Steel of grade YSt 210 to IS 4923:1997 in galvanized condition to be used for manufacturing square hollow sections. Steel used for manufacturing base plate is of Grade E250 to IS 2062:2011 in galvanized condition and foundation bolt is of Grade 5.6 in galvanized condition. Pole is hot dip galvanized to 80 microns to IS 2629:1985 / IS 4759:1996 / IS 2633:1986. The pole shall include 4 Nos. of hot dip galvanized M20 x 500mm foundation bolts. .The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree / equivalant MCB, terminal connectors for loop-in loop-out arrangement suitable of terminating Al armoured cables up to 25 Sq.m size. Pole shall include a support structures of advertisement board and Dimension of support structure 500mmx500mmx1000mm. The support structures of advertisment board shall adjustable type. The pole shall be integrated with LED module of 35/40W. System Lumens: Min 4000 lumens for 35/40 W, Luminaire Efficacy: 120 Lumen/Watt or above , CCT: 4000K, CRI: 70,a driver with surge protection of 10 kv, THD<=15%, PF:>=0.95, Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP66 rating .(Refer annexure-VI for drawing)
Supply, Erection, Testing and commissiong of 7 meter height decorative differential height Conical tapered type Lighting pole. Dimension of conical type lighting pole: bottom dia of the pipe shall be 146 mm and top dia of 76 mm and minimum not less than 2.5mm-3mm thick with single section height of 7000 mm.Pole shall be mounted on square base plate , suitable for mounting on 4 nos foundation bolts. The base plate dimensions shall be 240x240x14mm. The Pole Shaft/pipe should be fabricated out of Steel tube of grade YST 210/240. The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65microns before the coating of epoxy primer. Complete pole shall be treated with high quality epoxy zinc rich penetrating primer 45 microns(2 coats of primer) and thereafter coated with Polyurethane paint (to minimum average DFT of 70 microns). Steel of grade YSt 210 /240 to IS 4923:1997 in galvanized condition to be used for manufacturing conical hollow sections. Steel used for manufacturing base plate is of Grade E250 to IS 2062:2011 in galvanized condition and foundation bolt is of Grade 5.6 in galvanized condition.. The pole shall include 4 Nos. of hot dip galvanized M20 x 500mm foundation bolts. The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree / equivalant MCB, terminal connectors for loop-in loop-out arrangement suitable of terminating aluminium armoured cables up to 25 Sq.m size. The pole shall be of ‘composite’ construction designed to ‘wind load’ corresponding to a basic wind speed of 50 m/sec without any deformation or damage to the structure. Hot dip galvanised bracket of 1000mm length at height of 6.4mtr & lower bracket having length of 500mm at height of 5mtr, tightned with stainless steel grub screws to the pole for mounting luminaire. The entire system should be hot dip galvanised. The pole shall be integrated with LED module of 60W and 40W. The luminaire shall have an Integral power supply along with an earth connection and 10KV surge protection. - Luminaire shall be pre-wired. The pole shall be with foundation bolt, fittings, internal cabling, painting and printing of KMRL logo on Poles by consultation with KMRL.Pole shall include a support structures of advertisement board and Dimension of support structure 500mmx500mmx1000mm. The support structures of advertisment board shall adjustable type. The LED luminaire shall meet the following details. BIS certified with a luminaire body made of spun aluminium, permanently sealed optical block (IP66) with heat sink and a PMMA clear protector (IK07) fitted with a VentPlug pressure equalisation unit, fixed onto a hinged spun aluminium frame, control gear compartment accessed by opening clamps for tool free access.Highly efficient temperature resistant lenses for asymmetric light distribution with several optical options providing excellent photometry to optimally cater to different applications, suitable for suspended mounting. System Lumens: Min 7000 Lumens for 60 w and 4000 lumens for 40 W, Luminaire Efficacy: 120 Lumen/Watt or above , CCT: 4000K, CRI: >70,a driver with surge protection of 10/10 kv, THD<=15%, PF:>=0.95 with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP66 rating (Refer Annexure-IX for drawing)
FEEDER PILLAR CUM CCMS PANEL FOR GROUP CONTROL: Supply, unloading at site, shifting to site, assembling, levelling, grouting, foundation,erecting, earthing,cable termination, Testing, & Commissioning of Street light Feeder Pillar boxes as per tender specification Including with all accessories Complete as required as per standard and directions of officer .The feeder pillar shall be for group control of LED street lights in Access Road and High Mast system with all hard wares for power, control and communication devices and required software. It Shall be a GPRS/GSM/ RF / LORA/ based remote street light monitoring system with capacity for self - protection from short circuit, over voltage and anti- theft alert, one contactor for each phase is to be provided. Device capability for scheduling the on/off timings of lighting control switchgears based on the available sun-rise and sunset. Special emergency on/off facility with wireless control. System capability to capture and provide all electrical parameters at variable time intervals and live data collection timings. Smart Energy meter with ISI marking accuracy class for measuring energy consumption
Street light Management System Software: Development, Installation, testing, implementation and integration of Street light Management System (LMS). Lighting Control System should be deployed to manage the entire Street Lighting System under the scope of the project. The solution should be provided as a SaaS model. Fool proof communication is to be provided between luminaire and Light Management System (LMS). This could be using any or multiple form of communication networks, like LoRa, RF, GSM, etc. All group controls should have redundant communication system. System should exercise complete control over the streetlights and thus be able to monitor their functions / operations such as Scheduling, controlling Dimming, etc.The item covers all the necessary hardware and software required for the interface of LMS with the command and control centre as per the technical specification requirements.
Supply and making end termination with brass double compression gland and aluminium lugs for Making loop in loop out connection at connection terminals provided in street light pole for 4c 16 sqmm PVC sheathed/XLPE aluminium conductor cable of 1.1kv grade Complete as required including all accessories as per standard and directions of officer
Supply and erection of KSEBL approved make LT energy meter WITH METERING KIOSKS AND SUITABLE MCB including all accessories ,as per standard and directions of officer .
Supply, laying of XLPE insulated armoured cable with aluminium conductor size 4C 16 sq. mm for working voltage up to 1100v confirming to IS specification in the cable through supply,laying of 63mm dia /4KG pressure PN4 HDPE pipe ISI marked along with all accessories like socket, bend,couplers etc. conforming to IS 14930,Part II complete with fitting and cutting , jointing including cost of material , labour and all accessories for cable laying in cable duct/open cable trench and including road cutting,demolish the concrete,back filling ,paver block removing and restoration the same Complete as required. as per standard and directions of officer .
Supply, installation, Testing and commissioning of copper bonded pressed pipe filling with conductive & anti-corrosive minerals 48mm dia,1200mm long, 100 micron with 10Kg Highly conductive carbon based backfill compound suitable for areas with soil resisitivity (dry/rock area) complete including cost of all materials,labour and transportation as per standards and directions of officers.(Refer annexure-VIII for drawing)
Supply, installation, testing and commissioning of Decorative LED ground recessed marker luminaire with 9W for pedestrian zones. Luminaire body of extruded aluminium profile, die-cast aluminium components and a glass on top. With flush-fitting cover and integral LED unit. Highly weather resistant,powder-coated paint finish. Length of the luminaire is 900mm. Protection rating: IP67, impact resistance level in accordance with IEC62262: IK08. luminous efficiency of 70 lm/W. Correlated colour temperature (CCT) 4000K, colour rendering index (CRI) > 80. Mean rated service life of 50,000 hours at L70, rated voltage 240V. Including cost of Paver block/Granite removing without damage, restoration for the paver block/granite, restoration with smooth finishing and debris removing from the site etc. complete as required as per directions of officer
Supply, laying of XLPE insulated armoured cable with aluminium conductor size 4C 4 sq. mm for working voltage up to 1100v confirming to IS specification in the cable laying through existing HDPE pipe including loop in loopout termination , back filling, Concrete demolishing, road cutting,Paver block tile removing without damage, restoration for the paver block, reconcreting and debris removing from the site etc. complete as required as per standard and directions of officer
SCHEDULE-B OPERATION AND MAINTENANCE OF SMART LED LIGHTING SYSTEM WITH ALL SPARES, EQUIPEMENT AND MANPOWER : Setting up of a 24X7 Control and Monitoring with all required manpower / vehicles/ tools, testing equipments/ furniture etc
Operation and maintenance charges for third year including cost of cables,junction boxes,terminal block,connector,MCB,Ferule,Cable gland,Distribution board including all aceesories except light pole and fixtures .
Operation and maintenance charges for fourth year including cost of cables,junction boxes,terminal block,connector,MCB,Ferule,Cable gland,Distribution board including all aceesories except light pole and fixtures .
Operation and maintenance charges for fifth year including cost of cables,junction boxes,terminal block,connector,MCB,Ferule,Cable gland,Distribution board including all aceesories except light pole and fixtures .
Operation and maintenance charges for sixth year including cost of cables,junction boxes,terminal block,connector,MCB,Ferule,Cable gland,Distribution board including all aceesories except light pole and fixtures .
Operation and maintenance charges for seventh year including cost of cables,junction boxes,terminal block,connector,MCB,Ferule,Cable gland,Distribution board including all aceesories except light pole and fixtures .
Description of Work / Item(s)
Amount
Electrical Utility Shifting and UG cable conversion
Supply of HDPE pipe confirming to PN4 as specified the size given below, laying of HDPE pipe properly and continuously joined with suitable accessories and laying as per specification . 110mm
Supply at the site of work of 11kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of HDPE and laying of cables through HDPE pipes in all areas, all type of soil ,footpath,road ,etc by (open trench) excavation with laying arrangement in sand cushionn and brick/Tile protection at required depth ,refilling and restoration after laying of cables through pipe as required/approved by utility owning agency , Testing and commissioning of cable as required as per standards and directions of officer 11Kv XLPE 3x300sqmm
Supply at the site of work of 11kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of cables in cable duct including conveying cable from Sub Regional Store/stacking place to work site and cable duct slab opening and closing , laying it carefully using cable rollers and core cutting of cable duct for cable entry/exit ,after laying of cables through cable duct as required/approved by utility owning aegncy, testing & comissioning of cable et complete as required as per standards and directions of officers. 11Kv XLPE 3x300sqmm
Supply at the site of work of 11kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of cables in all type of soil ,footpath,road ,etc(open trench) by excavation with laying arrangement in sand cushionn and brick/Tile protection at required depth , refilling and restoration after laying of cables and testing & commissioning of cable et complete as required as per standards and directions of officers. 11Kv XLPE 3x300sqmm
Supply at the site of work of 1.1kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-l /1988 with up to date amendment & specified in the specification of the sizes given below, laying of HDPE pipe and cable laying through in HDPE pipe in all areas, all types of soil, footpath,road etc by open cable trench excavation with laying arrangement in sand cushion and brick/tile protection at required depth and refilling after laying of cables through pipes as required/ approved by utility, including supply & doing HS type end termination, testing & commissioning of cable et complete as required as per standards and directions of officers. 1.1Kv 3.5x185sqmm
Supply at the site of work of 1.1kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of cables in cable duct including conveying cable from Sub Regional Store/stacking place to work site and cable duct slab opening and closing , laying it carefully using cable rollers and core cutting of cable duct for cable entry/exit ,after laying of cables through cable duct as required/approved by utility owning aegncy, testing & comissioning of cable et complete as required as per standards and directions of officers. 1.1Kv 3.5x185sqmm
Supply at the site of work of 1.1kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-I/1988 with up to date amendment & specified in the specification of the sizes given below, laying of cables in open cable trench in all types of soil, footpath, road etc., by excavation with laying arrangement in sand cushion and brick/Tile protection at required depth , refilling and restoration after laying of cables as required/approved by utility, including supply & doing HS type end termination, and testing & commissioning of cable et complete as per standards and directions of officers. 1.1Kv XLPE 3.5x185sqmm
Supply ,Drawing of 11kv Aerial bunch cable of size 3x150 + 1x120(Insulated messenger) with suitable Anchor clamp/dead clamp,suspension clamp,surge arrestor,TEE/straight through joint,termination joint,cable ties,spiral earthing set,earth connector,fitting cross arms,stainless steel strap and buckle etc using 11kv Aerial bunch cable of size 3x150 + 1x120(Insulated messenger) including cutting and removing tree branches wherever necessary and conveyance of all materials from stacking place.at the site of work and testing & commissioning of Aerial bunch cable etc complete as required as per standards & specified in the specification of the below size 11 kV Ariel bunched cable XLPE insulated of size 3 x 150+ 1 x 120 sqmm with bare/insulated Messenger
Supply ,laying of 1.1kv Aerial bunch cable of size 3x95 + 1x70(Insulated messenger) with suitable Anchor clamp/dead clamp,suspension clamp,surge arrestor,TEE/straight through joint,termination joint,cable ties,spiral earthing set,earth connector,fitting cross arms,stainless steel strap and buckle etc using 1.1kv Aerial bunch cable of size 3x95 + 1x70(Insulated messenger) including cutting and removing tree branches wherever necessary and conveyance of all materials from stacking place.at the site of work of 1.1Kv Aeriel Bunched cable as per IS & specified in the specification of the below size. 1.1Kv Aeriel bunched cable XLPE insulated of size 3x95(For phase) + 1x70(insulated messenger nuetral) + 1x16(street light) sqmm.
Supply, Making testing & commissioning of complete Heat shrinkable type indoor/ outdoor type and end termination as specified in the specification including provision of laying,dressing, Tagging,Glanding with Lugs/ferrules for termination of 11kv HT XLPE insulated cable including making holes in the switch board, clamping supporting complete as required by utility owning agency following sizes and as per standards and directions of officers. Additional loop of cable should be made before end termination on the structure/Ground 11kv H S type 3x300 sqmm
Supply making testing & commissioning of 11kv HT XLPE cable complete Heat shrinkable type straight through joint as specified in the specification complete as required by utility owning agency including all accessories as per standards and directions of officers. 11kv H S type 3x300 sqmm
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCT type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator ,standard earthing of RMU and 11kv HS type end termination etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCC type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator ,standard earthing of RMU and 11kv HS type end termination etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCCT type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator ,standard earthing of RMU and 11kv HS type end termination etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCCC type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator ,standard earthing of RMU and 11kv HS type end termination etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCCCT type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator ,standard earthing of RMU and 11kv HS type end termination etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCCTT type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator ,standard earthing of RMU and 11kv HS type end termination etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, ADD ON Module RMU - Type - +C+ consists of 1nos Load Break switches with complete coupling accessories for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HS type end termination, ,standard earthing of RMU ,coupling with existing RMU etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, ADD ON Module RMU - Type - +V+ consists of 1nos Vaccum circuit breaker with complete coupling accessories for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HS type end termination,standard earthing of RMU, coupling with existing RMU etc complete including cost of all materials and labor, as per standards and directions of officers. (Make: ABB/Siemens/Schneider)
Fitting including supply of material one Fuse unit (one no.), giving connection from Transformer to fuse units, fuse units to LT OH line and provision of suitable protection cover including all accessories complete as required as per standards and directions of officers.
Dismantling (taking out from ground) if necessary all sizes of XLPE cable/Pilca/ Pvc cables, without damaging the cable. By excavation in all types of area (all type of soil) with refilling excavated Trenches as per standards and directions of officers. This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Dismantling (taking out from tarred road and concrete surface) if necessary all sizes of XLPE cable/Pilca/ Pvc cables, without damaging the cable. By excavation in all types of area with refilling excavated Trenches as per standards and directions of officers. This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Dismantling (without damage) LT3 phase 4/5 wire OH line including existing stucture ,stay,strut,cross arms,insulators, etc...and transportation and stacking of all materials at suitable locations as per instructions including digging out loading and unloading on to lorries without damaging the materials.This also includes handling over of materials to concerned utility agency.(including Transportation)
Dismantling (without damage) HT lines(3 conductor) including existing stucture ,stay,strut,cross arms,insulators, etc...and transportation and stacking of all materials at suitable locations as per instructions including digging out loading and unloading on to lorries without damaging the materials.This also includes handling over of materials to concerned utility agency.(including Transportation).
Dismantling and shifting of RMU at nearest locations and re- erecting, including foundation works ,Providing 11kv HS type end termination ,looping of cable etc and earthing complete as required as per standards and directions of officers.
Dismantling existing Transformer,DP/transformer Structure posts, etc of Transformer installation and transportation and stacking of all materials at suitable location as per instruction of officer including digging out loading and unloading on to lorries, etc of poles Transformers, and materials without damaging the same.Erecting the transformer on the new constructed plinth/DP structure and giving connections,fittings etc complete as per standards and directions of officers excluding cost of plinth.
Dismantling existing DP Structuress using A-pole /PSC pole as per instruction including digging out of poles , and materials without damaging the same including digging out,loading and unloadind and staking in suitable location.This also includes handling over of materials to concerned utility agency.(including Transportation).
Dismantling existing DP Structuress using A-pole /PSC pole as per instruction including digging out of poles , and materials without damage and reerecting the DP structure with the same materials at near by location as instructedby the officer.
Dismantling one LT PSC/RCC/RS Joists/TW pole,fittins,service connections etc including digging out and back filling pit .This also includes handling over of materials (if not relayed) to concerned utility agency.(including Transportation).Dismantling the existing street light fixtures with all accessories and erecting in nearest LT/HT poles as per KSEB standard and directions of officer
Dismantling one 11 kv A- pole/HT PSC/RCC/TW including accessories,fittings etc and This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Supply and erection at site LT/RSJ/PSC/RCC poles at site of required height including foundation digging and back filling with fittings including x-Arms and clamps / insulator,stay ,concrete muffing and including all materials cable loop In-loop-out as per standard and direction of officers
Supply and erection at site HT/RSJ/PSC/RCC poles at site of required height including foundation digging and back filling with fittings including x-Arms and clamps / insulator,stay ,concrete muffing including all materials cable loop In-loop-out as per standard and direction of officers
Supply and erection one A-pole (painted MS) at site of required Height including excavation , foundation and back filling , crossarms ,insulator,stay,earth leads including all materials as per standards and direction of officers.
Supply and erection one DP/Transformer structure using A-pole(painted MS) at site of required Height including foundation and AB switch, lightning arrestor, fittings, crossarms, insulator, cable looping, digging and back filling pit, earth leads including all materials as per standards and direction of officers.
Providing Strut using LT pole including digging and back filling pit( taken from the dismantled items).
Providing earthing for poles and support, pillar boxes panels, DP structures, Transformers, etc including supply of materials, Excavation, giving connection, laying lead wire, etc complete using 40mm Gi pipes 3mt long and Gi wires of size up to No.6 SWG.
Constructing Transformer plinth RCC foundation(Cement concrete column) including excavation in all type of soil,shuttering works , reinforcement , backfilling and restoation of the same . Foundation: adequate size M20 grade RCC foundation with Raft including excavation , backfilling and restoration of the same shall be done by the contractor. The item includes the excavation by mechanical means (hydraulic excavator)/manual means including disposal of excavated earth, disposed earth to be levelled and neatly dressed, in all kinds of soil inclusive of cost of all materials (as per specification) including suitable colour painting for the complete structure as per standards and direction of officers.Contractor shall submit design calculation in support of size of RCC foundation for approval.
Dismantling and reconnecting S ph service connection required from the OH line incl..lower down the WP portion
Dismantling and reconnecting 3 ph service connection required from the OH line incl..lower down the WP portion
Dismantling 11kv ABC conductor of size 3*150(for phase)+1*120(Insulated messenger) from existing HT PSC/A pole without damage as per standards and directions of officers.
Redrawing 11kv ABC of size 3*150 +1*120 sq. mm with anchor clamp/dead clamp,suspension clamp, surge arrestor, T/Straight through joint, termination joint,cable ties,spiral earthing , earth connector, fitting cross arms, stainless steel strap and buckle etc as per standards and specifications and direction of officers.
Dismantling and re erecting (without damage) LT3 phase 4/5 wire OH line including stay,strut,cross arms,insulators, including all materials at nearest LT/HT/A pole as as per standards and directions of officers.
Dismantling and re erecting (without damage) HT lines(3 conductor) including stay,strut,cross arms,insulators including all materials at nearest HT/A pole as as per standards and directions of officers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid