Tender Value
₹4.7 L
EMD Value
₹48,000
Closing Date
27 Aug 2026, 12:00 pm2d left
Office of the SE47(E/M)Circle PWD Moradabad
Office of the SE47(E/M)Circle PWD Moradabad
Janpad Nyayalya Rampur me Janpad Nyayadheesh evam apar janpad nyayadheesh ke nyayalaya kakshon evam vishram Kakshon me AC isthapna ka karya
2026_CEEMP_1176127_4
996/3WE(MBD)-47/2026 Dt. 27.07-2026
Open Tender
Electrical Works
Percentage
60 days
Rampur
As per NIT
2 documents required · 2 mandatory
₹677
Executive Engineer E/M Div PWD
₹48,000
As per NIT
27 Aug 2026
12 Aug 2026
27 Aug 2026
12 Aug 2026
27 Aug 2026
12 Aug 2026
13 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS / International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 0C (out door ambient temperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating
(Make- Carrier, Panasonic, LG, Blue Star) | 4 | each | 45,889.75 | ₹1,83,559 |
| 2 | Same as above but for 1.5 TR with 5 Star BEE Rating | 1 | each | 37,033.85 | ₹37,033.85 |
| 3 | S/F of Extra main lead wire 2.5 sq mm 4 core round copper cable for providing the power supply from the indoor unit to the outdoor unit for split AC.(without GST) | 85 | RM | 136.8 | ₹11,628 |
| 4 | S/F of Extra main lead wire 2.5 sq mm 3 core round copper cable for providing the power supply from Stabilizer to indoor unit for split AC.(without GST) | 5 | RM | 119.7 | ₹598.5 |
| 5 | S/F Automatic Voltage stabilizer 5 KVA voltage range130V to 280V for upto 2.0 Ton AC copper winding.(without GST) | 4 | each | 4,317.75 | ₹17,271 |
| 6 | S/F Automatic Voltage stabilizer 4 KVA voltage range130V to 280V for upto 1.5 Ton AC copper winding.(without GST) | 1 | each | 3,633.75 | ₹3,633.75 |
| 7 | SITC of Suction/Discharge copper pipe line in split AC unit 1.5 Ton capacity including brazing,nitrile, rubber insulation 6 mm thick class'O' etc. complete 1/4" (6.40mm) and 1/2"(12.70 mm).(without GST) | 17 | mtr | 983.25 | ₹16,715.25 |
| 8 | SITC of Suction/Discharge copper pipe line in split AC unit 1.8/2.0 Ton capacity including brazing,nitrile, rubber insulation 9 mm thick class'O' etc. complete 3/8" (9.50 mm) and 5/8"(15.90 mm).(without GST) | 68 | mtr | 1,239.75 | ₹84,303 |
| 9 | S/f of Extra Drain Pipe heavy duty PVC plastic braided 20 mm OD flexible pipe for condensed water drain with clipping accessories complete (without GST) | 60 | mtr | 136.8 | ₹8,208 |
| 10 | S/f of M.S angle iron mtg.bracket for outdoor unit with antirust paint.(without GST) | 5 | nos. | 1,068.75 | ₹5,343.75 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.01 MB
T1Rampur.pdf
Tender Documents • 6.97 MB
BOQ_2210294.xls
BOQ • 0.35 MB
ACCorrigenum.pdf
Additional Documents • 0.42 MB
Corrigendum19.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].