Loading…
Loading…
Tender ID
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.0 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹14.8 L+₹81,071.41 (5.81%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹15.2 L+₹1.2 L (8.77%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹15.2 L+₹1.2 L (8.92%)Admitted-Finance | L4 | Admitted-Finance | ||
| 5 | L5₹16.0 L+₹2.0 L (14.4%)Admitted-Finance | L5 | Admitted-Finance |
Tender Value
₹20.8 L
EMD Value
₹41,680
Closing Date
20 Feb 2026, 4:00 pmClosed
Executive Engineer PWD RandB Divisin Thanamandi
Executive Engineer PWD RandB Divisin Thanamandi
Construction of 2 ACR At Middle school Upper Shahdara
2026_PWDJK_303101_4
NIT No 105 of 2025 26 Dated 13 02 2026
Open Tender
Civil Works
Percentage
60 days
Thanamandi
Construction of 2 ACR At Middle school Upper Shahdara
3 documents required · 3 mandatory
₹600
Executive Engineer PWD RandB Divisin Thanamandi
₹41,680
5 Mar 2026
13 Feb 2026
21 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil :
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m
Brick work with common burnt clay (Non-Modular) bricks of class designation 7.5 in foundation and plinth including curing complete in Cement mortar 1:6 ( 1 cement : 6 coarse sand). Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) Brick work with common burnt clay (Non-Modular) bricks of class designation 7.5 in foundation and plinth including curing complete in Cement mortar 1:6 ( 1 cement : 6 coarse sand).
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
Reinforcement for RCC works including straightening, cutting, bending, placing in position and binding all complete all work up to plinth level and above plinth level , Thermo-Mechanically Treated bars of grade Fe-500D or more.,
Centering and shuttering including strutting, propping, etc and removal of form work for foundations , footings ,bases of columns, Plinth Beams etc.
Centering and shuttering including strutting, propping, etc and removal of form for suspended floors,roofs,landings,balconies and access platforms, stairs and spiral stairs cases.
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to steel windows by welding
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. Complete 50 mm thick with 20mm nominal size stone aggregate
Providing and fixing strips in joints of terrazzo/ cement concrete floors.Glass strips 40 mm wide and 4 mm thick
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second kail wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thickcPlain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws Second class Kail wood
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 150x10 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10 mm
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 100 mm
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 125 mm
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
EXTERIOR FINISHING Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing and fixing on wall face and on ground un-plasticized Rigid PVC rain/soil water pipes conforming to IS: 13592 Type A including jointing with seal ring confirming to IS:5283 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes
110 mm diameter
Wiring for light point fan point exhaust fan point/ call bell point with 1.5 sq.num FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch. modular plate, suitable G1 box and carthing the point with 1.5 sq.num FRLS PVC insulated copper conductor single core cable etc. complete job as per direction of engineer-in-charge
Carriage of material from source to site of work by mechanical transport including loading /unloading and stacking complete.
Sand for an average distance of 120 kms by M.T and 0.5 Km by H.L
Stone aggregate below 40 mm nominal size for an average distance 50 kms by M.T and 0.5 Km by H.L
Bricks for an average distance up to 100 km by M.T and 0.5 Km by H.L
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.39 MB
BOQ_983730.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .