Loading…
Loading…
Tender Value
₹2.6 Cr
EMD Value
₹5.1 L
Closing Date
23 Jul 2026, 3:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SNT TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where, V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar Nature of Work :- Any RI or EI or CLS or ABS or IBS work involving indoor & outdoor work (cable laying & termination).
6 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Checklist for Tenderer: The Tenderer shall submit signed copy of Check-list placed in documents attached with tender. The Tenderer shall also submit relevant documents of compliance of the checklist if any.
While bidding, bidder should submit the MOU of RDSO approved source (OEM or his RDSO approved source) of existing MEDHA make EI at the time of bidding covering supply of the equipment of EI, installation, alteration, testing and commissioning of EI including after sales support required during the warranty period and beyond the warranty period, failing which tender/offer shall be summarily rejected.
Bhavnagar Division: Supply installation, Testing, Commissioning of Signalling gears and alteration in Medha make Electronics Interlocking system at Dhasa, Kukavav & Chital stations in connection of (i) Surendranagar - Dhasa Track machine siding at 06 stations. Signaling work for alteration in EI at DAS station. (ii) Dhasa - Jetalsar section - Creation of siding facilities for track machine siding at two stations. (Chital and Kukavav).
DRMSnT-BVP-Sig13of26-27
DRMSnT-BVP-Sig13of26-27
Open
Works - General
12 Months
Bhavnagar, Gujarat
₹0
₹5.1 L
23 Jul 2026
30 Jun 2026
9 Jul 2026
354 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 9,11,271.55 | ||
| — | 1.00 | — | — | ||
| INPUT WFM CPU CARD for Medha make EI | — | — | — | 43,473 | |
| — | 1.00 | — | — | ||
| OUTPUT WFM CPU CARD for Medha make EI | — | — | — | 53,501 | |
| — | 1.00 | — | — | ||
| WFM RELAY DRIVER CARD for Medha make EI | — | — | — | 36,383 | |
| — | 0.50 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. (85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 16,683.1 | |
| — | 0.50 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 68,031.77 | |
| — | 0.50 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 66,252.56 | |
| — | 2.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 11,097.08 | |
| — | 2.00 | — | — | ||
| Extinguisher CO2 type (capacity 4.5 kg. or above). | — | — | — | 17,049.92 | |
| — | 2.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in Signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card.( Unit read as per module) | — | — | — | 59,487.26 | |
| — | 1.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. (unit read as per module). | — | — | — | 51,953.78 | |
| — | 100.00 | — | — | ||
| Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 5,099 | |
| — | 300.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 5,580 | |
| — | 50.00 | — | — | ||
| Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. | — | — | — | 2,860.5 | |
| — | 2.00 | — | — | ||
| Miniature, Plug in Type, M to C, DC Neutral, Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec: BRS :939-A & 966 (Appx-F2) & IRS: S-23, S-23, S-34 & 60. | — | — | — | 9,757.8 | |
| — | 2.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral, Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec: BRS:933A ; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 10,842.8 | |
| — | 2.00 | — | — | ||
| Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 7,046.54 | |
| — | 2.00 | — | — | ||
| Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | — | — | — | 1,956.92 | |
| — | 15.00 | — | — | ||
| Track Lead Junction Boxes as per C. Rly Drg. No. RST 11509 made from fibre glass/SMC/FRP along with terminal blocks. | — | — | — | 16,809.75 | |
| — | 1000.00 | — | — | ||
| GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. | — | — | — | 68,170 | |
| — | 10.00 | — | — | ||
| Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split- Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement). | — | — | — | 13,459.3 | |
| — | 1.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | — | — | — | 9,743.97 | |
| — | 3.00 | — | — | ||
| Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two no.s of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377 Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | — | — | — | 46,833.21 | |
| — | 1.00 | — | — | ||
| Apparatus Case half NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A fitted two nos E Type lock of (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | — | — | — | 9,893.99 | |
| — | 3.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet: 1000x1000x8 | — | — | — | 16,166.01 | |
| — | 100.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | — | — | — | 5,853 | |
| — | 500.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec Nos/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 37,500 | |
| — | 200.00 | — | — | ||
| Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type | — | — | — | 87,104 | |
| — | 10.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die, & 103.5 mm inner dia. One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | — | — | — | 19,122 | |
| — | 24.00 | — | — | ||
| Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 28,086.72 | |
| — | 6.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. | — | — | — | 62,418.48 | |
| — | 5.00 | — | — | ||
| Earth Electrode as per Drg. No. CSTE / 6091. | — | — | — | 13,994.95 | |
| — | — | — | 42,94,159.38 | ||
| — | 7.00 | — | — | ||
| INPUT WFM CPU CARD | — | — | — | 3,04,311 | |
| — | 2.00 | — | — | ||
| OUTPUT WFM CPU CARD | — | — | — | 1,07,002 | |
| — | 2.00 | — | — | ||
| WFM RELAY DRIVER CARD | — | — | — | 72,766 | |
| — | 2.00 | — | — | ||
| Supply of Relay Rack | — | — | — | 15,00,000 | |
| — | 100.00 | — | — | ||
| Rubber Mat for Power Equipment room. (5mm thick). | — | — | — | 12,163 | |
| — | 4.00 | — | — | ||
| Supply of Surge protection device (SPD) 4- Pole, 5 V versions similar to model no MDP- 4 D-5-T of OBO make. Make OBO, Phoenix, ABB or DEHN | — | — | — | 19,399.2 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq. mm.(85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 33,366.21 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 1,36,063.55 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 1,32,505.12 | |
| — | 2.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 11,097.08 | |
| — | 1000.00 | — | — | ||
| Supply of 35 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 2,47,740 | |
| — | 1000.00 | — | — | ||
| Supply of 10 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 1,05,670 | |
| — | 4.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 1,18,974.52 | |
| — | 2.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 1,03,907.56 | |
| — | 100.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 1,860 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged..pdf Digging
ATTACHMENT
CHECKLISTFORTENDERERmorethan50Lacs.pdf
ATTACHMENT
GCCACS11Merged_compressed.pdf
ATTACHMENT
TENDERCONDITIONANDSCHEDULEOFWORK.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .