GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVN OF 240KW POWER SUPPLY FOR FAST CHARGER AT MT SECTION OF HQ SWAC
2026_MES_796630_1
8532/26-27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CHILODA
As per tender document
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹58,180
Yes
30 Oct 2026
30 Oct 2026
23 Nov 2026
30 Oct 2026
21 Nov 2026
14 Nov 2026
30 Oct 2026 - 13 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, commisioning and testing factory made and tested, CPRI approved, LT Panel (KISOK), outdoor type, mounted on rigid angle iron frame, suitable size, having independent compartment for insulated Aluminium bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of not less than 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of 1000 Amp rating for 3 phase and neutal 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals , cable glands with independent plates at bottom for each out going and in coming cables in cable alley and complete board painted with powder coating in siemens grey colour front & rear opening type with double door shutter and locking arrangement including provision of 65 mm Godrej (freedom) lock with 2 keys, suitable aprons for cable entry/exist including taking down and refixing of exisiting cable properly with lug and thimable, Rate including for removal and taking out existing old/rusted LT Panel board of any type any size complete all as approved & complete all as specified and as directed by Engineer- in-Charge and comprising as under: -
Incoming :-
(i) 800A FP 50 KA EDO MICRO ACB (U - POWER) - 01 No
(ii) Under Voltage Release (UVR) 240V AC- 01 No.
(iii) Digital MFM Metering, Multifunction Meter. -01 No.
(iv) R-Y-B indicating lamps - 01 set.
(v) Control fuse -04 Nos.
(vi) CT -03 Nos
(vii)CT Short link - 04 Nos
(viii)6A SP 'C' MCB - 08 Nos
(ix) E- STOP Push button - 01 No
(x) R-G-O Indication Lamp - 01 No
(xi) Selector Switch 1 P 2 W 6A - 01 No
(xii) TNC Breaker Control Switch 25 A (1 NO + 1 NC) - 1 No
(xiii)On Delay Timer 0.3 Sec-30 Hrs (MICON 175) 240 - 415 VAC - 01 No | 1 | Each | - | - |
| 1.01 | Out going :-
(i) 630A FP 50 KA EDO MICRO ACB (U - POWER) - 02 Nos
(ii) Under Voltage Release (UVR) 240V AC- 02 Nos.
(iii) Digital MFM Metering, Multifunction Meter. -02 Nos.
(iv) R-Y-B indicating lamps - 02 set.
(v) Control fuse -08 Nos.
(vi) CT -06 Nos
(vii) CT Short link - 08 Nos
(viii)6A SP 'C' MCB - 16 Nos
(ix) E- STOP Push button - 02 Nos
(x) R-G-O Indication Lamp - 02 Nos
(xi) Selector Switch 1 P 2 W 6A - 02 Nos
(xii) TNC Breaker Control Switch 25 A (1 NO + 1 NC) - 02 Nos
(xiii) On Delay Timer 0.3 Sec-30 Hrs (MICON 175) 240 - 415 VAC - 02 Nos
(xiv) CRYO CC-510-B1-01-R _ 01 No
(xv) Door Limit Switch With Light - 03 Nos
(xvi) Cooling Fan 6 x 6 - 02 Nos
(xvii) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
(xviii) M & L for necessary excavation and as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job | - | - | - | - |
| 2 | Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc complete all as specified and as directed by Engineer- in-Charge. | 36 | CUM | - | - |
| 3 | Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm in Soft/loose soil complete all as specified and as directed by Engineer- in-Charge. | 24 | CUM | - | - |
| 4 | Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point in Soft / loose soil complete all as specified and as directed by Engineer- in-Charge. | 12 | CUM | - | - |
| 5 | Supply and laying dry Sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed.
Note : -
Thickness after punning will be measured for payment. | 11 | CUM | - | - |
| 6 | Supplying and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mmx 40mm complete all as specified and directed by Engineer in charge. | 810 | Each | - | - |
| 7 | Supply and lay and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 400 Sqmm 3.5 Core complete all as specified and as directed by Engineer- in-Charge.
Note: -
Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 120 | RM | - | - |
| 8 | Supply and Fixing PVC insulated unsheathed, multi stranded FRLS copper conductor flexible cable 1100 volt grade of size 185 Sqmm single core. laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and as directed by Engineer- in-Charge. | 20 | RM | - | - |
| 9 | Supply and Fixing PVC insulated unsheathed, multi stranded FRLS copper conductor flexible cable 1100 volt grade of size 50 Sqmm single core. laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and as directed by Engineer- in-Charge. | 20 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.35 MB
BOQ_893533.xls
BOQ • 1.58 MB
Tenderdocuments8532.pdf
Tender Documents • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .