Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC DOOR NO 44 19 10 RAILWAY NEW COLONY BEHIND SIVALAYAM VISAKHAPATNAM AP 530016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.9 L+₹3,665 (0.47%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹8.0 L+₹11,840 (1.50%)Rejected-Finance DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹8.2 L+₹29,889 (3.79%)Rejected-Finance 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹8.3 L+₹43,830 (5.56%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
22 Jul 2022, 6:00 pmClosed
Shri Nitesh K Singh, IDSE AEE AGE (I) R and D NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8401 REPAIRS/ REPLACEMENT OF INTERNAL WIRING WITH FITTINGS/ FIXTURES AND CONNECTED ACCESSORIES AT RESIDENTIAL AREA UNDER AGE (I) RnD NSTL, VISAKHAPATNAM
2022_MES_533413_1
AGE I R AND D NSTL VIZAG 8401
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Visakhapatnam
Class E Category b(i)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹19,000
Yes
14 Sept 2022
24 Jun 2022
25 Jul 2022
24 Jun 2022
22 Jul 2022
8 Jul 2022
Amount
Taking down carefully point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, removing materials from site and making good the disturbed surfaces of walls, floors etc as per existing specification and taken as credit complete all as specified and as directed by the Engineer-in-Charge.
Taking down sub main wiring of aluminium/copperconductor PVC insulated cable of any size drawn through rigid steel / PVC conduit GI wire accessories etc complete and removing materials from site and making good the disturbed surfaces of walls, floors etc as per existing specification and taken as credit complete all as specified and as directed by the Engineer-in-Charge.
M & L for Point Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded with copper conductors conforming to IS specifications, with colour code drawn through and including non metallic rigid PVC conduit, PVC conduit fittings and conduit accessories or casing capings incl acceesoires fixed on wall/ ceiling or concealed on wall and fixed on ceiling etc with suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified and as directed for One light/ Fan/ Bell/ Exhaust fan controlled by one switch
All as per above item No 03 above but for one three/ five pin switch scoket combination 5 Amps on independent board.
All as per item No.03 above but below/parallel the switch board of independent 5 Amps socket in the same vertical/horizontal plane.
All as per above item No 03 above but with three runs 2.5 sqmm copper conductor cable for one three/ five pin switch socket combination 15 Amps on independent board.
Supply and fix in repair of Switch piano type 5 Amp single pole one way complete all as specified and directed.
Supply and fix in repair of Switch piano type 5 Amp single pole two way complete all as specified and directed.
Supply and fix switch socket combination along with gang box 5 amp flush type complete all as specified and directed.
Supply and fix switch socket combination multipurpose along with gang box 3 pin 15 Amp and 3 pin 5 amp flush type 2 in 1 complete all as specified and directed
Supply and fixing one module switch modular type, single pole one way 6/10 Amps 230 Volts ISI Marked all as specified and as directed by the Engineer-in-Charge.
Supply and fixing one module switch modular type, single pole one way 16 Amps 230 Volts ISI Marked all as specified and as directed by the Engineer-in-Charge.
Supply and fixing socket two module type 6 Amps , 3 pin , 230 Volts ISI Markedall as specified and as directed by the Engineer-in-Charge.
Supply and fixing socket two module type 6/16 Amps, twin socket , 3 pin , 230 Volts ISI Markedall as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling rose surface backelite min dia 35 mm three terminal complete all as specified and directed.
Supply and fix Modular bell push 6 Amp, 2 modular 230 volts one way complete all as specified and directed
Supply and fix call Bell single pole, ding dong type and including 03 mm thick plastic laminated sheet cover of suitable size with brass screws and washers etc complete all as directed.
Supply and fixing of cover plate 1 module with inner frame
Supply and fixing of cover plate 2module with inner frame
Supply and fixing of cover plate 4 module with inner frame
Supply and fixing of cover plate 8 module with inner frame horizontal/vertical type
S & F in replacement modular blank plate, two module 240 volts,50 Hz all as directed.
S & F in replacement modular blank plate, three module 240 volts,50 Hz all as directed.
Taking down the old unserviceable security light fitting of any type and taken as credit and Supply & Fix LED base bldg security lamainare 20 Watt with pressure die cast aluminium housing with Poly carbonate coverand high power LEDs and secondary lenses with IP 66 Protection including 40x6mm flat iron clamps,nut,bolts,washer with 32 mm dia GI pipe light grade bracket bend to shape not less than 1.2 m long complete all as spcified and directed. Make: Havells, Cat part no:LHEXAYP7PN6K020 or equivalent model of Philips / Crompton/ Bajaj
Taking down the old unserviceable SK fitting/ FTL fitting/ lamp holder and taken as credit and supply and fix LED light fitting (Efficacy: 100 lumen/ watt), 4 feet, 20W, 230v , Box type, wall mounted extruded aluminium housing enhances safety, High quality PC diffuser, connector block etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Havells, Cat part no: LHEXAWP7IN1J020 or equivalent model of Philips / Bajaj/Crompton
Taking down the old unserviceable SK fitting/ FTL fitting/ lamp holder and taken as credit and supply and fix LED light fitting (Efficacy: 100 lumen/ watt), 2 feet, 10W, 230v , Box type, wall mounted extruded aluminium housing enhances safety, High quality PC diffuser, connector block etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Crompton, Cat part no: LDL-10-NW or equivalent model of Philips /Hevells/ Bajaj
Taking down the old unserviceable Tube light and taken as credit and Supply and fix LED polycarbonate 20 Watt T8 tube rod in built driver with metal heat sink Double sided connection suitable as per site requirement including necessary connections complete all as specified. Make: Bajaj Cat Part No.BLRB-DB 118 or equivalent model model of Philips /Havells/ Crompton
Taking down the old unserviceable CFL/ Bulb of any type and taken as credit and Supply and fix LED Bulb type B22 of 9 watts complete all as specified. Make: Crompton, or equivalent model of Philips /Havells/ Bajaj
Taking down the old unserviceable SK Fitting/ Bulk head fitting of any type and taken as credit and Supply and fix LED Bulk head light fitting of 10 watts complete all as specified. Make: Crompton, Cat No. LBHP-10-CDL or equivalent model of Philips /Hevells/ Bajaj
M&L For Sub main wiring concealed with 2.5 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 2.5 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
M&L For Sub main wiring concealed with 4.0 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 4.0 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
M&L For Sub main wiring concealed with 6.0 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 6.0 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
S&F in repairs of single phase static energy meters in LCD display from 5A-30A, 240 volts AC supply,50 Hz with backlit LCD display with push button (measures KW,KVA,SIX MONTHS HISTORY OF ENERGY & MD IN KW&KVA) tamper proof with making incoming & outgoing cable connection with proper thimble and sealing the meter alongwith Optical port + Box as specified and directed.(The cost of sealing of meter shall be included in the meter cost) Direct connected Wiring Single phase, two wire Voltage range 230/240 V (L-N) Current range 5-30 A, Accuracy Class 1.0, Mains frequency 50 Hz ± 5% Burden , Make-HPL, Cat no SPPB1320110000OC00 & Equivalent in L&T,SECURE. Note :- Old electric meter shall be deposited in E/M store yard on own contractor cost.
S&F in repairs of Three phase static energy meter of accuracy class 1.0 3x240 V,50 Hz,with backlit LCD display of rating 10-60A (MEASURES & DISPLAYS kwh,V,I,KW,PF,Hz,last month history of KWH & MD in KW) with special features like TOD,Tamper logging,optical communication port 7 display in absence of power complete all as specified and directed by Engr-in-charge.Make :HPL Cat No.TPPB1521130000ME01 & Equivalent in L&T,SECURE Note :- Old electric meter shall be deposited in E/M store yard on own contractor cost.
Material & Labour in replacement of Earthing complete with galvanised steel earth electrode 60Cm x 60Cm x 6 mm thick directly burried in ground (earth pit not less than 2.25 M deep below the normal ground level conneceted to galvanised earth lead dia 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron steel including necessery excavation earth work PCC chamber CI chamber cover protection pipe watering pipe etc. (Complete all as shown in electrical plate No 3 and conected to earthing test point complete including excavation earthwork, PCC chamber, chamber cover ,funnel watering and protection pipe etc all specified and directed and testing on completion. Note:- If the desired earth resistance is not less than 5 Ohms, earthing shall be redone by the contractor at no extra cost to the department.
M&L Earthing continuity galvanised earth lead dia 4 mm dia or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
LAKSHMI SAI CONSTRUCTIONS
B SRINIVAS
SVG SUPPLIES
LEO ENTERPRISES
SRI LAKSHMI GANAPATHI CONSTRUCTIONS
KRISHNA ENGINEARING
M/s ANUSHA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .