Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹29.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹29.9 L+₹74,353 (2.55%)Rejected-AOC 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹29.9 L+₹74,353 (2.55%) | L2 | Rejected-AOC L2 |
| 3 | L3₹31.1 L+₹1.9 L (6.58%)Rejected-AOC H NO 6 1ST FLOOR P B ROAD SUHAGPUR REBARARI GUWAHATI 08 | GUWAHATI | ₹31.1 L+₹1.9 L (6.58%) | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | VOLKS ENERGIE PVT LTD L1 | Lyric International L2 | RS COOLING APPLIANCES L3 |
|---|---|---|---|---|---|---|
| 1.00 | VRF HIGH SIDE WORK
Supply of 415v 3Ph 50Hz Top Discharge Modular type only cool Next Generation Variable Refrigerant Flow system, each Outdoor unit (The COP shall be 4.02 at 100% load at AHRI conditions) comprises of 100% Inverter Driven Hermatically sealed Scroll Compressors, air cooled Condenser with 100% Capacity at 44 deg. C, protective coated fins heat exchangement with Corrossion fin factory coated Propeller type fan with Motor, Specially designed ODU with refrigerant cooled head sink; Non-stop working at 56 deg. C. Outdoor with with capable of working within Range of Voltage fluctuation from 380V to 420V, auto addressing setting, refrigerant cooled PCB, electronic expansion valve. MicroProcessor Controller with R410A gas.
18.0 HP (Top Discharge) | 3 | Nos. | 4,78,518 ₹14,35,554 | 4,02,542 ₹12,07,626 Lowest | 4,34,490 ₹13,03,470 |
| 2.00 | Indoor Unit
Supply of below mentioned capacities Cassette type indoor air conditioners complete with evaporator coil, fan and fan motor, control panel as per specifications and drawings.
a) 2.3 TR 4 Way Cassette ( VLC- 27) Check in Counter Area | 3 | Nos | 45,000 ₹1,35,000 | 51,271 ₹1,53,813 | 41,190 ₹1,23,570 Lowest |
| 3.00 | Indoor Unit
Supply of below mentioned capacities Cassette type indoor air conditioners complete with evaporator coil, fan and fan motor, control panel as per specifications and drawings.
b) 2.8 TR 4 Way Cassette (VLC- 34 ) Arrival Area | 13 | Nos | 50,000 ₹6,50,000 | 50,000 ₹6,50,000 | 45,690 ₹5,93,970 Lowest |
| 4.00 | Supply of Cordless Remore Controller | 16 | Nos | 1,050 ₹16,800 Lowest | 1,780 ₹28,480 | 1,290 ₹20,640 |
| 5.00 | Supply of Refnet joints for indoor and outdoor units of suitable size complete as required. | 16 | Nos. | 3,500 ₹56,000 Lowest | 6,347 ₹1,01,552 | 6,990 ₹1,11,840 |
| 6.00 | Outdoor Unit
Installation, Testing and Commissioning of below mentioned capacities VRF outdoor units with Nitrogen flushing & pressure testing including Lifting and Shifting of VRF ODU Unit complete as required.
18.0 HP ( Top Discharge ) | 3 | Nos | 20,000 ₹60,000 Lowest | 38,136 ₹1,14,408 | 32,490 ₹97,470 |
| 7.00 | Indoor Unit
Installation, Testing and Commissioning of below mentioned capacities VRF Indoor units with Nitrogen flushing 6 pressure testing complete as required.
a) 2.3 TR 4 Way Cassette ( VLC- 27) Check in Counter Area | 3 | Nos. | 3,000 ₹9,000 | 3,517 ₹10,551 | 2,029 ₹6,087 Lowest |
| 8.00 | Indoor Unit
Installation, Testing and Commissioning of below mentioned capacities VRF Indoor units with Nitrogen flushing 6 pressure testing complete as required.
b) 2.8 TR 4 Way Cassette (VLC- 34 ) Arrival Area | 13 | Nos. | 2,900 ₹37,700 | 3,814 ₹49,582 | 2,290 ₹29,770 Lowest |
| 9.00 | Refrigerant Pipe Works: ( For VRF )
Supply, Installation, Testing and Commissioning of interconnecting copper circuit refrigerant pipe work (19mm/13mm) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor 6 outdoor units as per specifications. Joints shall be covered with nitrite rubber tape of 3 mm thick complete as per specification. (Both pipes Liquid & Gas) complete as required. | 200 | Rmt. | 1,500 ₹3,00,000 | 1,144 ₹2,28,800 Lowest | 1,790 ₹3,58,000 |
| 10.00 | Drain piping:
Providing and fixing of Hard PVC drain water piping with fittings, support and insulated with 9mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications.
Dia 25 mm | 110 | Rmt. | 100 ₹11,000 Lowest | 119 ₹13,090 | 270 ₹29,700 |
Tender Value
₹33.6 L
EMD Value
₹1.0 L
Closing Date
11 Mar 2026, 3:00 pmClosed
Asst. General Manager (Engg-E)
AAI, Silchar Airport
Improvement of Air Conditioning Inside Arrival Hall at Silchar Airport
2026_AAI_267728_1
AAI/SIL/ENGG-E/AC/2025-26
Open Tender
Electrical Works
Works
90 days
AAI, Silchar Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹1.0 L
30 Apr 2026
18 Feb 2026
12 Mar 2026
19 Feb 2026
11 Mar 2026
19 Feb 2026
19 Feb 2026 - 25 Feb 2026
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
TD.pdf
Tender Documents • 8.92 MB
BOQ_311499.xls
BOQ • 0.29 MB
CORIB.pdf
PDF • 0.81 MB
CORIA.pdf
PDF • 0.75 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .