| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-AOC | ₹7.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹7.3 Cr+₹21.6 L (3.05%)Rejected-AOC AGHAPUR RAMPUR UTTAR PRADESH 244901 | RAMPUR | UTTAR PRADESH | 244901 | ₹7.3 Cr+₹21.6 L (3.05%) | L2 | Rejected-AOC L2 |
| 3 | L3₹7.4 Cr+₹28.6 L (4.04%)Rejected-AOC 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹7.4 Cr+₹28.6 L (4.04%) | L3 | Rejected-AOC L3 |
| 4 | L4₹7.4 Cr+₹34.3 L (4.85%)Rejected-AOC 44 1 3 VILL RITHANI DELHI ROAD WEST RITHANI MEERUT UTTAR PRADESH 250103 | MEERUT | UTTAR PRADESH | 250103 | ₹7.4 Cr+₹34.3 L (4.85%) | L4 | Rejected-AOC L4 |
| 5 | L5₹7.6 Cr+₹55.8 L (7.89%)Rejected-AOC | ₹7.6 Cr+₹55.8 L (7.89%) | L5 | Rejected-AOC L5 |
Tender Value
₹8.6 Cr
EMD Value
₹17.3 L
Closing Date
3 Jan 2020, 5:00 pmClosed
Superintending Engineer,Contract and Procurement-I
VCV Gabar Singh Urja Bhawan
Construction of 33/11KV GIS Substations under IPDS on turnkey basis Package-IPDS-33KV SS-GIS-GADARPUR
2019_UPCLC_21567_1
CCP-I/23/2019-2020
Open Tender
Electrical Works
Turn-key
365 days
As per tender specification
As per tender specification
6 documents required · 6 mandatory
₹23,600
Executive Engineer, ESD, UPCL
₹17.3 L
30 May 2020
13 Dec 2019
4 Jan 2020
13 Dec 2019
3 Jan 2020
28 Dec 2019
Amount
CONSTRUCTION OF 2X10 MVA 33/11kV SUB-STATIONS WITH INDOOR GAS INSUALTED SWITCHGEAR AT Majra Seela Gadarpur
33kV substation class II Surge Arrestor
33kV 3 Pole 1250A Line Isolator (Verticle Type)
33kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33kV Outdoor cable termination kit (3CX300 SQMM)
33kV Indoor cable termination kit (3CX300 SQMM)
10 MVA, 33/11 KV Power Transformer with On Load Tap Changer with complete RTCC & related accessories
63 kVA, 33/0.4 KV Oil Cooled Type for Substation supply.
9kV, 10kA Outdoor type Lighting Arrestors
11kV 800A Outdoor Type Isolators (TPMO Switch)
33kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (With termination kits) CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 600-300/5-5A
Bus Coupler Panel
Bus Riser Panel
11kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (with termination kits) with required CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 400-200/5-5A
Bus Coupler Panel
Bus Riser Panel
APFC panel for 10 MVA Transformer
11kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33 kV 3CX70 SQMM XLPE Cable and its laying
11kV Outdoor Cable termination kit (3CX300 SQMM)
11kV Indoor Cable termination kit (3CX300 SQMM)
33kV Outdoor Cable termination kit (3CX70SQMM)
33 kV Indoor Cable termination kit (3CX70SQMM)
LT Power & Control Cable from Station T/F to AC DB along with suitable crimping lugs and its laying:
3.5CX120SqMM LT Power Cable Aluminium
LT PVC Cable Aluminium 4X10 Sq MM
LT PVC Cable Aluminium 2X6 Sq MM
10CX2.5 SqMM LT Control Cable Copper
4CX2.5 SqMM LT Control Cable Copper
Suitable rating lugs, glands, braided copper wire/Strip (50X500MM) with coppper lugs
Battery & Charger
110V Battery Set (300AH) - Tubular type
110V Battery Charger (300AH) with Automatice boost and trickle charge.
110V DCDB
AC Power distribution Board
Earth of Substation and equipments
(i) 32MM MS Round
(ii) 65X6MM GI Strip
(iii) 40/50X6 GI Strip
(iv) Special chemical earthing
(v) Gravel pitching 1/2" to 3/4"
Cost of fire & safety equipments of Substation
(i) CO2 type ire Extingusher confirming IS 2878-1976 and cylinder fully charged of 4.5kg capacity
(ii) Foam type Fire Extingusher portable type 5 Lit capacity hang on wall with bracket complete as required.
(iii) Metal fire bucket with sand
(iv) Stand of chuggi type of MS Angle 50X50X6 MM with top covered by MS sheet 1.5MM thickness duly painted with Red color including fabrication complete
Mics items for Substation like:
Rubber mat 1X2MtX 12MM thick suitable for 11kV/33kV di-electic strenght
Steel office table, Godrej, (5'x3')
Steel office table, Godrej, (4'x2.5')
Steel Almirah, Godrej,
Steel cabinet, Godrej,
Steel office chair, Godrej,
Shock treatment chart
Danger board
Shut down / Break down board (Bi-lingual Hindi & English)
HT Hand Gloves
Wall Clock
Insulated electrical Plier Taparia
D-Spanner Set Taparia
3 cells Torch
Pipe wrench, 12" Taparia
First aid Box
Earth chain brass 12 mtr. Length
5 KV Megger Digital (Make-Motwane)
2.5kv Megger Digital (Make-Motwane)
Earth Megger Digital (Make-Motwane)
Instruction board 3’x2½’ of Flex board duly printed.
Single line diagram of size 3’x2½’ on flex board, duly printed.
Maximum & tripping display board of size 5’x3’ of mica board moulded with frame duly painted & writing.
Sub-station name board (Size 3'x2' of MS sheet & MS angle 45x45x5 mm, Height 1.5 mtr. Above ground level ), duly painted
Name plate of equipment TG, LI, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, cable glands for control cable.
Perforated Cable Tray
(iii) 100MM
LIGHTING ARRANGEMENT AT YARD AND S.G. ROOM
S.T. Pole 8 mtr. Long S.P.-10
Iron clad 30 Amps water proof switch on the ST pole.
250W, HPSV/ LED lamp with control gear & mounting accessories
150W, HPSV/ LED lamp with control gear & mounting accessories & 15 A MCB's
Incoming/Outgoing 33KV/11kV Double Pole Strcuture complete in all respect including MS Channel, Earth Rod, Stay Set, Polymer Isnulators, Dics Fittings, GI wire,PP& clamps, fuse set,TPMO SWITCH, GI Pipe 4"X3.0Mt, MS Plate,complete structure for S/S T/F as per electricity noms complete
MS strcuture steel, angle, channel, Rail, MS Bar, RS Joist, MS Plate. Duly painted 1 coat Red Oxide, 2 coat aluminium paint - Aisan, Burger, Dulux.
Wire Mesh fencing with gate, RS Joist, duly painted on both sides with green color and red oxide as per specifications including civil works, stay post,
CONSTRUCTION OF 33 KV UNDERGROUND EXISITING LINE AT Majraseela GADARPUR
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe at the depth of about 1meter as per site requirement & Cable dia including provision of cable route markers in CC casting etc. complete in all respect in the form original before digging.
33KV (E) XLPE HT cable 3x400sqmm
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers without open excavation in HDPE pipe:
33KV (E) XLPE HT cable 3x400sqmm
Supply, erection, testing and commissioning of HT cable termination Kits / Straight through
33 KV (E) XLPE HT cable 3 x 400 sq.mm (Outdoor)
33kV Touch proof termination kits 3X400Sq MM (suitable for 33kV RMU) (Indoor)
33KV (E) XLPE HT cable 3x400sqmm (Straight thro)
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Road crossing, culverts, crossings, by side of bridges with support hangers, fastners, complete in all respects.
Description of Work / Item(s)
Amount
CONSTRUCTION OF 2X10 MVA 33/11kV SUB-STATIONS WITH INDOOR GAS INSUALTED SWITCHGEAR AT Majra Seela Gadarpur
33kV substation class II Surge Arrestor
33kV 3 Pole 1250A Line Isolator (Verticle Type)
33kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33kV Outdoor cable termination kit (3CX300 SQMM)
33kV Indoor cable termination kit (3CX300 SQMM)
10 MVA, 33/11 KV Power Transformer with On Load Tap Changer with complete RTCC & related accessories
63 kVA, 33/0.4 KV Oil Cooled Type for Substation supply.
9kV, 10kA Outdoor type Lighting Arrestors
11kV 800A Outdoor Type Isolators (TPMO Switch)
33kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (With termination kits) CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 600-300/5-5A
Bus Coupler Panel
Bus Riser Panel
11kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (with termination kits) with required CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 400-200/5-5A
Bus Coupler Panel
Bus Riser Panel
APFC panel for 10 MVA Transformer
11kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33 kV 3CX70 SQMM XLPE Cable and its laying
11kV Outdoor Cable termination kit (3CX300 SQMM)
11kV Indoor Cable termination kit (3CX300 SQMM)
33kV Outdoor Cable termination kit (3CX70SQMM)
33 kV Indoor Cable termination kit (3CX70SQMM)
LT Power & Control Cable from Station T/F to AC DB along with suitable crimping lugs and its laying:
3.5CX120SqMM LT Power Cable Aluminium
LT PVC Cable Aluminium 4X10 Sq MM
LT PVC Cable Aluminium 2X6 Sq MM
10CX2.5 SqMM LT Control Cable Copper
4CX2.5 SqMM LT Control Cable Copper
Suitable rating lugs, glands, braided copper wire/Strip (50X500MM) with coppper lugs
Battery & Charger
110V Battery Set (300AH) - Tubular type
110V Battery Charger (300AH) with Automatice boost and trickle charge.
110V DCDB
AC Power distribution Board
Earth of Substation and equipments
(i) 32MM MS Round
(ii) 65X6MM GI Strip
(iii) 40/50X6 GI Strip
(iv) Special chemical earthing
(v) Gravel pitching 1/2" to 3/4"
Cost of fire & safety equipments of Substation
(i) CO2 type ire Extingusher confirming IS 2878-1976 and cylinder fully charged of 4.5kg capacity
(ii) Foam type Fire Extingusher portable type 5 Lit capacity hang on wall with bracket complete as required.
(iii) Metal fire bucket with sand
(iv) Stand of chuggi type of MS Angle 50X50X6 MM with top covered by MS sheet 1.5MM thickness duly painted with Red color including fabrication complete
Mics items for Substation like:
Rubber mat 1X2MtX 12MM thick suitable for 11kV/33kV di-electic strenght
Steel office table, Godrej, (5'x3')
Steel office table, Godrej, (4'x2.5')
Steel Almirah, Godrej,
Steel cabinet, Godrej,
Steel office chair, Godrej,
Shock treatment chart
Danger board
Shut down / Break down board (Bi-lingual Hindi & English)
HT Hand Gloves
Wall Clock
Insulated electrical Plier Taparia
D-Spanner Set Taparia
3 cells Torch
Pipe wrench, 12" Taparia
First aid Box
Earth chain brass 12 mtr. Length
5 KV Megger Digital (Make-Motwane)
2.5kv Megger Digital (Make-Motwane)
Earth Megger Digital (Make-Motwane)
Instruction board 3’x2½’ of Flex board duly printed.
Single line diagram of size 3’x2½’ on flex board, duly printed.
Maximum & tripping display board of size 5’x3’ of mica board moulded with frame duly painted & writing.
Sub-station name board (Size 3'x2' of MS sheet & MS angle 45x45x5 mm, Height 1.5 mtr. Above ground level ), duly painted
Name plate of equipment TG, LI, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, cable glands for control cable.
Perforated Cable Tray
(iii) 100MM
LIGHTING ARRANGEMENT AT YARD AND S.G. ROOM
S.T. Pole 8 mtr. Long S.P.-10
Iron clad 30 Amps water proof switch on the ST pole.
250W, HPSV/ LED lamp with control gear & mounting accessories
150W, HPSV/ LED lamp with control gear & mounting accessories & 15 A MCB's
Incoming/Outgoing 33KV/11kV Double Pole Strcuture complete in all respect including MS Channel, Earth Rod, Stay Set, Polymer Isnulators, Dics Fittings, GI wire,PP& clamps, fuse set,TPMO SWITCH, GI Pipe 4"X3.0Mt, MS Plate,complete structure for S/S T/F as per electricity noms complete
MS strcuture steel, angle, channel, Rail, MS Bar, RS Joist, MS Plate. Duly painted 1 coat Red Oxide, 2 coat aluminium paint - Aisan, Burger, Dulux.
Wire Mesh fencing with gate, RS Joist, duly painted on both sides with green color and red oxide as per specifications including civil works, stay post,
CONSTRUCTION OF 33 KV UNDERGROUND EXISITING LINE AT Majraseela GADARPUR
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe at the depth of about 1meter as per site requirement & Cable dia including provision of cable route markers in CC casting etc. complete in all respect in the form original before digging.
33KV (E) XLPE HT cable 3x400sqmm
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers without open excavation in HDPE pipe:
33KV (E) XLPE HT cable 3x400sqmm
Supply, erection, testing and commissioning of HT cable termination Kits / Straight through
33 KV (E) XLPE HT cable 3 x 400 sq.mm (Outdoor)
33kV Touch proof termination kits 3X400Sq MM (suitable for 33kV RMU) (Indoor)
33KV (E) XLPE HT cable 3x400sqmm (Straight thro)
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Road crossing, culverts, crossings, by side of bridges with support hangers, fastners, complete in all respects.
Description of Work / Item(s)
Amount
CONSTRUCTION OF 2X10 MVA 33/11kV SUB-STATIONS WITH INDOOR GAS INSUALTED SWITCHGEAR AT Majra Seela Gadarpur
33kV substation class II Surge Arrestor
33kV 3 Pole 1250A Line Isolator (Verticle Type)
33kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33kV Outdoor cable termination kit (3CX300 SQMM)
33kV Indoor cable termination kit (3CX300 SQMM)
10 MVA, 33/11 KV Power Transformer with On Load Tap Changer with complete RTCC & related accessories
63 kVA, 33/0.4 KV Oil Cooled Type for Substation supply.
9kV, 10kA Outdoor type Lighting Arrestors
11kV 800A Outdoor Type Isolators (TPMO Switch)
33kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (With termination kits) CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 600-300/5-5A
Bus Coupler Panel
Bus Riser Panel
11kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (with termination kits) with required CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 400-200/5-5A
Bus Coupler Panel
Bus Riser Panel
APFC panel for 10 MVA Transformer
11kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33 kV 3CX70 SQMM XLPE Cable and its laying
11kV Outdoor Cable termination kit (3CX300 SQMM)
11kV Indoor Cable termination kit (3CX300 SQMM)
33kV Outdoor Cable termination kit (3CX70SQMM)
33 kV Indoor Cable termination kit (3CX70SQMM)
LT Power & Control Cable from Station T/F to AC DB along with suitable crimping lugs and its laying:
3.5CX120SqMM LT Power Cable Aluminium
LT PVC Cable Aluminium 4X10 Sq MM
LT PVC Cable Aluminium 2X6 Sq MM
10CX2.5 SqMM LT Control Cable Copper
4CX2.5 SqMM LT Control Cable Copper
Suitable rating lugs, glands, braided copper wire/Strip (50X500MM) with coppper lugs
Battery & Charger
110V Battery Set (300AH) - Tubular type
110V Battery Charger (300AH) with Automatice boost and trickle charge.
110V DCDB
AC Power distribution Board
Earth of Substation and equipments
(i) 32MM MS Round
(ii) 65X6MM GI Strip
(iii) 40/50X6 GI Strip
(iv) Special chemical earthing
(v) Gravel pitching 1/2" to 3/4"
Cost of fire & safety equipments of Substation
(i) CO2 type ire Extingusher confirming IS 2878-1976 and cylinder fully charged of 4.5kg capacity
(ii) Foam type Fire Extingusher portable type 5 Lit capacity hang on wall with bracket complete as required.
(iii) Metal fire bucket with sand
(iv) Stand of chuggi type of MS Angle 50X50X6 MM with top covered by MS sheet 1.5MM thickness duly painted with Red color including fabrication complete
Mics items for Substation like:
Rubber mat 1X2MtX 12MM thick suitable for 11kV/33kV di-electic strenght
Steel office table, Godrej, (5'x3')
Steel office table, Godrej, (4'x2.5')
Steel Almirah, Godrej,
Steel cabinet, Godrej,
Steel office chair, Godrej,
Shock treatment chart
Danger board
Shut down / Break down board (Bi-lingual Hindi & English)
HT Hand Gloves
Wall Clock
Insulated electrical Plier Taparia
D-Spanner Set Taparia
3 cells Torch
Pipe wrench, 12" Taparia
First aid Box
Earth chain brass 12 mtr. Length
5 KV Megger Digital (Make-Motwane)
2.5kv Megger Digital (Make-Motwane)
Earth Megger Digital (Make-Motwane)
Instruction board 3’x2½’ of Flex board duly printed.
Single line diagram of size 3’x2½’ on flex board, duly printed.
Maximum & tripping display board of size 5’x3’ of mica board moulded with frame duly painted & writing.
Sub-station name board (Size 3'x2' of MS sheet & MS angle 45x45x5 mm, Height 1.5 mtr. Above ground level ), duly painted
Name plate of equipment TG, LI, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, cable glands for control cable.
Perforated Cable Tray
(iii) 100MM
LIGHTING ARRANGEMENT AT YARD AND S.G. ROOM
S.T. Pole 8 mtr. Long S.P.-10
Iron clad 30 Amps water proof switch on the ST pole.
250W, HPSV/ LED lamp with control gear & mounting accessories
150W, HPSV/ LED lamp with control gear & mounting accessories & 15 A MCB's
Incoming/Outgoing 33KV/11kV Double Pole Strcuture complete in all respect including MS Channel, Earth Rod, Stay Set, Polymer Isnulators, Dics Fittings, GI wire,PP& clamps, fuse set,TPMO SWITCH, GI Pipe 4"X3.0Mt, MS Plate,complete structure for S/S T/F as per electricity noms complete
MS strcuture steel, angle, channel, Rail, MS Bar, RS Joist, MS Plate. Duly painted 1 coat Red Oxide, 2 coat aluminium paint - Aisan, Burger, Dulux.
Wire Mesh fencing with gate, RS Joist, duly painted on both sides with green color and red oxide as per specifications including civil works, stay post,
Civil Works for Transformer plinth, S/s Transformer structures, Cable trench, Pole
Brick work in 1:4
Plaster in 1:4
Excavation of earth in mixed soil
Construction of S.G.R Building
Earth work in excavation by mechanical means (Hydraulic excavator ) manual means in foundation tranches (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. (All kinds of soil). (DSR item No. 2.8.1)
Supplying and filling in plinth with Jamuna sand under floors including. Watering, ramming consolidating and dressing complete.(DSR item No. 2.27)
Clearing jungle including uprooting of rank vegetation, grass, brush wood trees and saplings of girth upto 30 cm measured at a height of 1 m 50 m outside the periphery of the area cleared. (DSR item No. 2.31)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level:1:4 :8 (1 Cement :4 coarse sand: 8 graded stone agg. 40 mm nominal size) (DSR item No. 4.1.8)
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size). (DSR item No. 4.1.3)
Providing and laying D.P.C 40 cm thick with cement concrete 1:2:4 ( 1 cement :2 coarse sand: 4 graded stone aggregate 12.5 mm nominal size) (DSR item No. 4.10)
Providing/ laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering,up to plinth level: 1:1:5:3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 cm nominal size). (DSR item No. 5.1.2)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: 1:2:4 (1 cement :2 coarse sand:4 graded stone aggregate 20 cm nominal size). (DSR item No. 5.1.3)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, posts reinforcement. 1:1:5:3 (1 cement : 1.5 coarse sand 3 graded stone aggregate 20 cm nominal size). (DSR item No. 5.2.2)
Reinforced cement concrete working beams, suspended floors, roofs having slope up to 1.5 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral/ of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement :2 coarse sand:4 graded stone aggregate 20 cm nominal size). (DSR item No. 5.3)
Centering and shuttering including strutting propping etc. and removal of form for: Foundations footings, bases of columns, etc. For mass concrete (DSR item No. 5.9.1)
Centering and shuttering including strutting propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.(DSR item No. 5.9.3)
Centering and shuttering including strutting propping etc. and removal of form for: Shelves (Cast in situ)(DSR item No. 5.9.4)
Centering and shuttering including strutting propping etc. and removal of form for: Lintels, beams, plinth beams girders, bressumers and cantilevers, (DSR item No. 5.9.5)
Centering&shuttering including strutting propping etc. and removal of form for:. Columns, Pillars, Piers, Abutments, Posts and Struts.(DSR item No. 5.9.6)
Centering& shuttering including strutting propping etc. and removal of form for. Weather shade, Chaffas, corbels etc. including edges. (DSR item No. 5.9.19)
Reinforcement for R.C.C. work incl.straightening, cutting, bending, placing in position and binding all complete. (TMT bars ). (DSR item No. 5.22.6)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4( 1 cement : 4 coarse sand) (DSR item No. 6.1.1)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.1.2)
Brick work with F.P.S. Bricks of class designation 75 in S/S above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.4.2)
Half brick masonry with F.P.S. bricks of class designation 75 in s/s above planth level up to floor V level. Cement morat 1:4 ( 1 cement : 4 coarse sand) (DSR item No. 6.13.2)
P/F 18mm thick gang saw cut mirror polished pre moulded and prepolished) machine cut for kitchen platforms, , windos sills, facias& similar locations of required sixe of approved shade colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment,, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/Udaipur green marble/Zebra black margle.. : Area of slab upto 0.50 sqm. (DSR item No. 8.2.1.1)
Extra for providing edge moulding to 18 mm thick marble stone conters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge (Marble work) (DSR item No. 8.3.1)
P/F ISI marked flush door shutters conforming to IS: 2202 (PartI) decorative type, core of block board construction with frame of 1st. Class hard wood and well matchd teak 3ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (35 mm th.incl.ISi marked Stainlss Steel butt hinges with screws. ) (DSR item No. 9.20.1)
P/ fixing M.S. grills of required pattem in frames of windows etc. with M.S. flats square or round bars etc. all complete. (Fixed to steel windows by welding). (DSR item No. 9.48.1)
P/Fixing IS:3564 marked Aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. (DSR item No. 9.84)
P/fixing aluminium sliding door bolts ISI marked anodised (Anodic coating not less than grade AC 10 as per IS:1868) etc. complete: (250x16mm) (DSR item No. 9.96.2)
P/fixing aluminium tower bolts ISI marked anodised (Anodic coating not less than grade AC 10 as per IS:1868)transparent or dyed to required colour or shade with nuts and screws etc. complete: (200x10mm) (DSR item No. 9.97.3)
P/fixing aluminium tower bolts ISI marked anodised (Anodic coating not less than grade AC 10 as per IS:1868)transparent or dyed to required colour or shade with nuts and screws etc. complete: (150x10mm) (DSR item No. 9.97.4)
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary scerews etc. complet: 125mm (DSR item No. 9.100.1)
Providing and fixing aluminium floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) etc. complet: Twin rubber stopper. (DSR item No. 9.101.2)
Providing and fixing in position collapaible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with botts, nuts locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. (DSR item No. 10.3)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and comers, all necessary fittings complete, including applying a priming coat of aproved steel prmer. (Usingflats 30 x6mm for diagonal braces and central cross piece.) (DSR item No. 10.5.2)
Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover (DSR item No. 10.6.1)
Providing and fixing ball bearing for rolling shutters. (DSR item No. 10.7)
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area (DSR item No. 10.8.1)
steel work welded in built up sections/ framed work including cutting, hoisting fixing in position and applying a priming coat of approved steel primer susing structural steel etc. as required. (In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.) for raillings etc. (DSR item No. 10.25.2)
Cement concrete flooring 1:2:4 (1 cement : 2coarse sand : 4 gradd stone aggregate) finished with a floating coat of neat cement including cement slurry, (40 mm thick with 20mm nomnal sxe stone aggregate). (DSR item No. 11.3.1)
Providing/fixing glass strips in joints of terrazo/cement concrete floors. (40mm wide and 4mm thick) (DSR item No. 11.13.1)
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS: 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile. (DSR item No. 11.21.1.1)
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by E/I over 20mm (average) thick base of cement mortar 1:4 ( 1cement: 4coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete with: (Raj Nagar plain). (DSR item No. 11.23.1)
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigement to match the shade of the slab including rubbing and polishing omplete with base of cement mortar 1:4 (1 cement: 4 coarse sand): 25mm thick. (DSR item No. 11.26.1)
Kota stone slabs 25mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (avg.) thick cement mortar 1:3 (1cement : 3 c.sand )incl. rubbing and polishing complete. (DSR item No. 11.27)
Extra for pre finished noising in treads of steps of Kota stone/sand stone slab. (DSR item No. 11.31)
P/F Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacture) of approved make in all colours, s@ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR item No. 11.36)
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS; n 20 mm thick Cement Mortar 1:4 ( 1 cement :4 Coarse sand ) (DSR item No. 11.37)
Providing and laying polished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption,s less than 0.08% and conforming to IS 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) including grouting the joints with white cement and matching pigments etc, complete. (size of Tile 60x60cm) (DSR item No. 11.41.2)
Providing and laying pressed clay tiles (as per approved pattem 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 ( 1 cement :4 coarse sand) mixed with 2% integral water prooling compound laid over a bed of 20 mm thick cement mortar 1:4 ( 1cement:4c/sand ) and finished neat complete. (DSR item No. 12.20)
Providing and fixing 100mm diameter and 60cm long rain water spolut in cement mortar 1:4 (1cement ;4fine sand).(DSR item No. 12.37.1)
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concreete blocks 10x10x10cm of 1:2:4mix (1 cement:2coarse sand:4graded stone aggregate 20mm nominal size) and cost of cutting holes and making good the walis etc. (100 mm diameter). (DSR item No. 12.38.1)
P/F on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 (i) Single socketed pipes (75mm diameter) (DSR item No. 12.40.1)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointin with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes (110mm diameter) (DSR item No. 12.41.2)
12mm cement plaster of mix: 1:6 (1cement :6coarse sand) (DSR item No. 13.4.2)
12mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1cement : 4coarse sand) (DSR item No. 13.7.2)
Add or deduct of plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR item No. 5.30)
Providing/applying plaster of paris putty of 2mm th. over plastered surface to prepare the surface even and smooth complete. (DSR item No. 13.26)
Distempering with oil bound washable distemper of app. brand and manufacture to give an enen shade . New work (two or more coats ) over& incl. priming coat with cement primer. (DSR item No. 13.41.1)
Finishing walls with water proffing cement paint on required shade: New work (Two or more coats applied @ 3.84kg/10sam0 (DSR item No. 13.44.1)
Finishing wall with textured exterior paint of required shade: New work (two or moar coats applied @ 3.28 ltr/10sqm over and including base coat of water proofing cement paing applied @2.20kg/10sqm. (DSR item No. 13.45.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved prand and manufacture. (DSR item No. 13.62.1)
Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work (DSR item No. 13.64.1)
Forming groove of uniform size from 12x12mm and upto 25x15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges o plaster panel and finishing the groove complete as per specifications and direction of the E/I. (DSR item No. 13.76)
Renewing glass panes, with putty and nails wherever necessary . Float glass panes of thickness 4mm (DSR item No. 14.5.1)
Supplying and stacking at site.Good earth (DSR item No. 16.3.9)
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast lron P or S trap. 10 litre low level white P.V.C. flushning cistem with manually controlled device (handle lever ) conforming to IS: 7231, with all fitting and fixtures complete including cutting adn making good the walls and floors wherever required: White Vitreous china Orissa patern W.C. pan of size 580x440mm with integral type foot rests. (DSR item No. 17.1.1)
Providing and fixing white vitreous china pedestal type water closet (European tyope W.C. pan) with seat and lid , 10 litre low level white P.V.C. flushing cistern with manually controlled decice (handle lever), conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid (DSR item No. 17.2.1)
Providing and fixing wash basin with C.I. brackets 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets cutting and making good the walls wherever require: White Vitreous china Flat back wash basin size 550x400mm with a pair of 15mm C.P. brass pillar tap. (DSR item No. 17.7.4)
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR item No. 17.24)
Providing /fixing 600x450mm beveled edge mirror of superior glass (of approved quality ) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws & washers complete. (DSR item No. 17.31)
Providing anf fixing soil, waste and vent pipes: 100mm dia( Sand cast iron S&S pipe as per IS:1729) (DSR item No. 17.35.1.1)
Providing anf fixing soil, waste and vent pipes: 75mm diameter: ( Sand cast iron S&S pipe as per IS:1729) (DSR item No. 17.35.2.1)
Providing/fixing the joints with spun yam cement slurry and cement mortar 1:2 ( 1cement:2fine sand ) in S.C.I/C.I. pipes: 75mm dia pipe (DSR item No. 17.36.1)
Providing and fixing the joints with spun yam cement slurry and cement mortar 1:2 ( 1cement:2fine sand ) in S.C.I/C.I. pipes: 100mm dia pipe (DSR item No. 17.36.2)
Providing and fixing M.S. holder-bat clamps of approved design to Sand cast iron/cast iron(spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4mix( 1cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 75mm dia. pipe. (DSR item No. 17.37.2)
Providing and fixing terminal guard: :75mm (Sand cast iron S&S as per IS- 1729) (DSR item No. 17.56.2.1)
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 100mm (DSR item No. 17.58.1)
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 75mm (DSR item No. 17.58.2)
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P. brass screws with concealed fitting arrangement of approved quality an colour. 450mm long towel rail with total length of 495mm 78mm wide and effective height of 88mm, weighing not less than 170gms. (DSR item No. 17.73.1)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps including cutting and making good the walls etc. Internal work -Exposed on wall. 15mm dia. nominal bore (DSR item No. 18.10.1)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps including cutting and making good the walls etc. Internal work -Exposed on wall. 20mm dia. nominal bore (DSR item No. 18.10.2)
Concealed pipe including painting with anti corrosive bitumasiic paint cutting chases& making good the wall . 15mm dia nominal bore (DSR item No. 18.11.1)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15mm dia nominal bore (DSR item No. 18.12.1)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20mm dia nominal bore (DSR item No. 18.12.2)
Constructing masonry Chamber 30x30x50 cm inside with 75 class designation brick work in cement mortar 1:4 (1cement : 4coarse sand) for stop cock with C.I. surface bozx 100x100x75mm (insside) with hinged cover fixed in cement concrete slab 1:2:4 mix ( 1cement : 2coarse sand: 4 graded stone aggregate 20mm nomnal size) necessary excavation foundation concrete 1:5:10( 1cement:5fine sand :10 graded stone aggregate 40mm nominal size) and inside plastering with cemnt mortar 1:3 (1cement:3coarse sand ) 12mm thick finsished with a floating coat of neat cement complete as per standard design . With F.P.S. bricks (DSR item No. 18.32.1)
Providing and placing on terrace (at all floor levels) polyethylene water stonrage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for nilet, outlet and overflow pipes but without fittings and the base support for tank. (DSR item No. 18.48)
Providing anf fixing C.P. brass bib cock of approved quality conforming to IS: 8931 (15mm nominal bore). (DSR item No. 18.49.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 a(15mm nominal bore) (DSR item No. 18.53.1)
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, thight of 75mm with concealed fitting arrangements. Weighing not less than 106gms (DSR item No. 18.65)
Providing and fixing aluminium work for doors, windows ventilators and partitions with extruded built up standard tubular sections/ approprate Z ections and other sections of approprate make conforming to IS: 733 and IS: 1285 fixed with rawl plugs and screws of with fixing clips or with expanision hold fasteners including necessary filling up of gapu at junctions at top bottom and sides with required PVC/ neoperene felt etc. For fixed portion. (DSR item No. 21.1.1.2)
Providing and fixing aluminium work for doors, windows ventilators and partitions with extruded built up standard tubular sections/ approprate Z ections and other sections of approprate make conforming to IS: 733 and IS: 1285 fixed with rawl plugs and screws of with fixing clips or with expanision hold fasteners including necessary filling up of gapu at junctions at top bottom and sides with required PVC/ neoperene felt etc. : For shutters of doors windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required (DSR item No. 21.1.2.2)
Providing/fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle borad conforming to IS: 12823 Grade I Type II in panelling fixied in aluminum doors windows sutters and partition frames with C.P. brass/ stainless stell screws etc. (DSR item No. 21.2.2)
Providing and fixing glazing in aluminium door, window ventilator shutters and partitons etc. with PVC/ neoprene gasket etccomplete as per the architectural) With flot glass panes of 5.50mm thickness (DSR item No. 21.3.2)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness (DSR item No. 21.4.1)
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. (DSR item No. 21.13)
Providing fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge.Powder coated minimum thickness 50 micron aluminium (DSR item No. 21.16.2)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. pipe. (DSR item No. 19.6.4)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable 1.5 sqmm FR PVC insulated copper conductor single core cable etc as requited. GROUP B (DSR item No. 1.1.2)
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (DSR item No. 1.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required Circuit / sub main wiring in PVC codute 2*1.5 Sq.M*1*1.5 Sq.M (DSR item No. 1.7.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ sub main wiring in PVC codute 2*2.5 Sq.M*1*2.5Sq.M (DSR item No. 1.7.2)
S/F stepped type electronic fan regulator on the existing moduler plate switch box incl.connection but excluding moduler plate etc.required. (DSR item No. 1.25)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (DSR item No. 1.29)
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. (DSR item No. 1.30)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. (DSR item No. 1.41)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., incl.s/f ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable earthing etc. as required. (DSR item No. 1.42)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (DSR item No. 1.45)
S/ fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Single door (DSR item No. 2.45.1)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. (DSR item No. 5.5)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)2 + 6 way/ 8 way , Double door (DSR item No. 2.3.6)
S/F 5amp to 32amp rating 240 volts,B series,MCB suitable for lighting and other loads of single pole in the existing MCB D.B complete with connection ,testing and commissioning etc. as required. Single pole (DSR item No. 2.10.1)
S/F 5amp to 32amp rating 240 volts,B series,MCB suitable for lighting and other loads of single pole in the existing MCB D.B complete with connection ,testing and commissioning etc. as required. Double pole (DSR item No. 2.10.3)
Supply of factory wired HPF box type 1x40 Watt flurescent tube fitting of approved quality ( Bajaj,Havells or equilent make) with requisite accessories like electronic ballast, Tube etc. complete. (NSI)
Supply of 1200 mm sweep ceiling fan of approved quality ( Bajaj,USHA, Havells or equilent make) without regulator. (NSI)
Supply of 300 mm sweep ventilating fan of approved quality ( Bajaj, USHA, Havells or equilent make) without regulator. (NSI)
Land development
Earth work in excavation by mechanical means (Hydraulic excavator ) manual means in foundation tranches (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. (All kinds of soil). (DSR item No. 2.8.1)
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5m (DSR item No. 2.25)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. (DSR item No. 2.31)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (DSR item No. 4.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level:1:4 :8 (1 Cement :4 coarse sand: 8 graded stone aggregate 40 mm nominal size) (DSR item No. 4.1.8)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 cm nominal size). (DSR item No. 5.1.2)
Reinforced cement concrete work in walls (any thickness),including attached pillasters,buttresses,plinth and string courses, fillets, columns, pillars,piers,abutments,posts and struts etc. upto floor five levels,excluding cost of centering,shuttering,finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (DSR item No. 5.2.2)
Reinforced cement concrete working beams, suspended floors, roofs having slope up to 1.5 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral/ stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). (DSR item No. 5.3)
Centering and shuttering including strutting propping etc. and removal of form for: Lintels, beams, plinth beams girders, bressumers and cantilevers, (DSR item No. 5.9.5)
Centering and shuttering including strutting propping etc. and removal of form for:Columns,Pillars,Piers,Abutments,Posts and Struts. (DSR item No. 5.9.6)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. (TMT bars ). (DSR item No. 5.22.6)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.1.2)
Brick work with F.P.S. Bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.4.2)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) (DSR item No. 6.13.2)
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR item No. 10.16.1)
steel work welded in built up sections/ framed work including cutting, hoisting fixing in position and applying a priming coat of approved steel primer susing structural steel etc. as required. (In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.) (DSR item No. 10.25.2)
12mm cement plaster of mix: 1:6 (1cement :6coarse sand) (DSR item No. 13.4.2)
15mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1cement :6coarse sand) (DSR item No. 13.5.2)
Finishing wall with textured exterior paint of required shade: New work (two or more coats applied @ 3.28 ltr/10sqm over and including priming coat of exterior primer applied @2.20kg/10sqm. (DSR item No. 13.45.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved prand and manufacture. (DSR item No. 15.2.1)
Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) verendah and etc. (DSR item No. 15.2.1)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR item No. 15.7.4)
Engaging suitable Beldar for petty works (DSR item No. 114)
Stone tile work for wall lining upto 10m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade. (i) 12mm thick stone Textured Exterior cladding tiles. (NSI)
Supplying and stacking at site.Good earth (DSR item No. 16.3.9)
CONSTRUCTION OF 33 KV UNDERGROUND EXISITING LINE AT Majraseela GADARPUR
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe at the depth of about 1meter as per site requirement & Cable dia including provision of cable route markers in CC casting etc. complete in all respect in the form original before digging.
33KV (E) XLPE HT cable 3x400sqmm
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers without open excavation in HDPE pipe:
33KV (E) XLPE HT cable 3x400sqmm
Supply, erection, testing and commissioning of HT cable termination Kits / Straight through
33 KV (E) XLPE HT cable 3 x 400 sq.mm (Outdoor)
33kV Touch proof termination kits 3X400Sq MM (suitable for 33kV RMU) (Indoor)
33KV (E) XLPE HT cable 3x400sqmm (Straight thro)
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Road crossing, culverts, crossings, by side of bridges with support hangers, fastners, complete in all respects.
CIVIL WORKS
Making and casting of Manholes , wherever required for obervation/ monitoring the cable as per site requirement including CI heavy duty chamber
Description of Work / Item(s)
Amount
CONSTRUCTION OF 2X10 MVA 33/11kV SUB-STATIONS WITH INDOOR GAS INSUALTED SWITCHGEAR AT Majra Seela Gadarpur
33kV substation class II Surge Arrestor
33kV 3 Pole 1250A Line Isolator (Verticle Type)
33kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33kV Outdoor cable termination kit (3CX300 SQMM)
33kV Indoor cable termination kit (3CX300 SQMM)
10 MVA, 33/11 KV Power Transformer with On Load Tap Changer with complete RTCC & related accessories
63 kVA, 33/0.4 KV Oil Cooled Type for Substation supply.
9kV, 10kA Outdoor type Lighting Arrestors
11kV 800A Outdoor Type Isolators (TPMO Switch)
33kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (With termination kits) CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 600-300/5-5A
Bus Coupler Panel
Bus Riser Panel
11kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (with termination kits) with required CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 400-200/5-5A
Bus Coupler Panel
Bus Riser Panel
APFC panel for 10 MVA Transformer
11kV 3CX300 SQMM XLPE Cable and its laying in Trenches
33 kV 3CX70 SQMM XLPE Cable and its laying
11kV Outdoor Cable termination kit (3CX300 SQMM)
11kV Indoor Cable termination kit (3CX300 SQMM)
33kV Outdoor Cable termination kit (3CX70SQMM)
33 kV Indoor Cable termination kit (3CX70SQMM)
LT Power & Control Cable from Station T/F to AC DB along with suitable crimping lugs and its laying:
3.5CX120SqMM LT Power Cable Aluminium
LT PVC Cable Aluminium 4X10 Sq MM
LT PVC Cable Aluminium 2X6 Sq MM
10CX2.5 SqMM LT Control Cable Copper
4CX2.5 SqMM LT Control Cable Copper
Suitable rating lugs, glands, braided copper wire/Strip (50X500MM) with coppper lugs
Battery & Charger
110V Battery Set (300AH) - Tubular type
110V Battery Charger (300AH) with Automatice boost and trickle charge.
110V DCDB
AC Power distribution Board
Earth of Substation and equipments
(i) 32MM MS Round
(ii) 65X6MM GI Strip
(iii) 40/50X6 GI Strip
(iv) Special chemical earthing
(v) Gravel pitching 1/2" to 3/4"
Cost of fire & safety equipments of Substation
(i) CO2 type ire Extingusher confirming IS 2878-1976 and cylinder fully charged of 4.5kg capacity
(ii) Foam type Fire Extingusher portable type 5 Lit capacity hang on wall with bracket complete as required.
(iii) Metal fire bucket with sand
(iv) Stand of chuggi type of MS Angle 50X50X6 MM with top covered by MS sheet 1.5MM thickness duly painted with Red color including fabrication complete
Mics items for Substation like:
Rubber mat 1X2MtX 12MM thick suitable for 11kV/33kV di-electic strenght
Steel office table, Godrej, (5'x3')
Steel office table, Godrej, (4'x2.5')
Steel Almirah, Godrej,
Steel cabinet, Godrej,
Steel office chair, Godrej,
Shock treatment chart
Danger board
Shut down / Break down board (Bi-lingual Hindi & English)
HT Hand Gloves
Wall Clock
Insulated electrical Plier Taparia
D-Spanner Set Taparia
3 cells Torch
Pipe wrench, 12" Taparia
First aid Box
Earth chain brass 12 mtr. Length
5 KV Megger Digital (Make-Motwane)
2.5kv Megger Digital (Make-Motwane)
Earth Megger Digital (Make-Motwane)
Instruction board 3’x2½’ of Flex board duly printed.
Single line diagram of size 3’x2½’ on flex board, duly printed.
Maximum & tripping display board of size 5’x3’ of mica board moulded with frame duly painted & writing.
Sub-station name board (Size 3'x2' of MS sheet & MS angle 45x45x5 mm, Height 1.5 mtr. Above ground level ), duly painted
Name plate of equipment TG, LI, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, cable glands for control cable.
Perforated Cable Tray
(iii) 100MM
LIGHTING ARRANGEMENT AT YARD AND S.G. ROOM
S.T. Pole 8 mtr. Long S.P.-10
Iron clad 30 Amps water proof switch on the ST pole.
250W, HPSV/ LED lamp with control gear & mounting accessories
150W, HPSV/ LED lamp with control gear & mounting accessories & 15 A MCB's
Incoming/Outgoing 33KV/11kV Double Pole Strcuture complete in all respect including MS Channel, Earth Rod, Stay Set, Polymer Isnulators, Dics Fittings, GI wire,PP& clamps, fuse set,TPMO SWITCH, GI Pipe 4"X3.0Mt, MS Plate,complete structure for S/S T/F as per electricity noms complete
MS strcuture steel, angle, channel, Rail, MS Bar, RS Joist, MS Plate. Duly painted 1 coat Red Oxide, 2 coat aluminium paint - Aisan, Burger, Dulux.
Wire Mesh fencing with gate, RS Joist, duly painted on both sides with green color and red oxide as per specifications including civil works, stay post,
Civil Works for Transformer plinth, S/s Transformer structures, Cable trench, Pole
Brick work in 1:4
Plaster in 1:4
Excavation of earth in mixed soil
Construction of S.G.R Building
Earth work in excavation by mechanical means (Hydraulic excavator ) manual means in foundation tranches (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. (All kinds of soil). (DSR item No. 2.8.1)
Supplying and filling in plinth with Jamuna sand under floors including. Watering, ramming consolidating and dressing complete.(DSR item No. 2.27)
Clearing jungle including uprooting of rank vegetation, grass, brush wood trees and saplings of girth upto 30 cm measured at a height of 1 m 50 m outside the periphery of the area cleared. (DSR item No. 2.31)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level:1:4 :8 (1 Cement :4 coarse sand: 8 graded stone agg. 40 mm nominal size) (DSR item No. 4.1.8)
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size). (DSR item No. 4.1.3)
Providing and laying D.P.C 40 cm thick with cement concrete 1:2:4 ( 1 cement :2 coarse sand: 4 graded stone aggregate 12.5 mm nominal size) (DSR item No. 4.10)
Providing/ laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering,up to plinth level: 1:1:5:3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 cm nominal size). (DSR item No. 5.1.2)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: 1:2:4 (1 cement :2 coarse sand:4 graded stone aggregate 20 cm nominal size). (DSR item No. 5.1.3)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, posts reinforcement. 1:1:5:3 (1 cement : 1.5 coarse sand 3 graded stone aggregate 20 cm nominal size). (DSR item No. 5.2.2)
Reinforced cement concrete working beams, suspended floors, roofs having slope up to 1.5 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral/ of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement :2 coarse sand:4 graded stone aggregate 20 cm nominal size). (DSR item No. 5.3)
Centering and shuttering including strutting propping etc. and removal of form for: Foundations footings, bases of columns, etc. For mass concrete (DSR item No. 5.9.1)
Centering and shuttering including strutting propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.(DSR item No. 5.9.3)
Centering and shuttering including strutting propping etc. and removal of form for: Shelves (Cast in situ)(DSR item No. 5.9.4)
Centering and shuttering including strutting propping etc. and removal of form for: Lintels, beams, plinth beams girders, bressumers and cantilevers, (DSR item No. 5.9.5)
Centering&shuttering including strutting propping etc. and removal of form for:. Columns, Pillars, Piers, Abutments, Posts and Struts.(DSR item No. 5.9.6)
Centering& shuttering including strutting propping etc. and removal of form for. Weather shade, Chaffas, corbels etc. including edges. (DSR item No. 5.9.19)
Reinforcement for R.C.C. work incl.straightening, cutting, bending, placing in position and binding all complete. (TMT bars ). (DSR item No. 5.22.6)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4( 1 cement : 4 coarse sand) (DSR item No. 6.1.1)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.1.2)
Brick work with F.P.S. Bricks of class designation 75 in S/S above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.4.2)
Half brick masonry with F.P.S. bricks of class designation 75 in s/s above planth level up to floor V level. Cement morat 1:4 ( 1 cement : 4 coarse sand) (DSR item No. 6.13.2)
P/F 18mm thick gang saw cut mirror polished pre moulded and prepolished) machine cut for kitchen platforms, , windos sills, facias& similar locations of required sixe of approved shade colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment,, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/Udaipur green marble/Zebra black margle.. : Area of slab upto 0.50 sqm. (DSR item No. 8.2.1.1)
Extra for providing edge moulding to 18 mm thick marble stone conters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge (Marble work) (DSR item No. 8.3.1)
P/F ISI marked flush door shutters conforming to IS: 2202 (PartI) decorative type, core of block board construction with frame of 1st. Class hard wood and well matchd teak 3ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (35 mm th.incl.ISi marked Stainlss Steel butt hinges with screws. ) (DSR item No. 9.20.1)
P/ fixing M.S. grills of required pattem in frames of windows etc. with M.S. flats square or round bars etc. all complete. (Fixed to steel windows by welding). (DSR item No. 9.48.1)
P/Fixing IS:3564 marked Aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. (DSR item No. 9.84)
P/fixing aluminium sliding door bolts ISI marked anodised (Anodic coating not less than grade AC 10 as per IS:1868) etc. complete: (250x16mm) (DSR item No. 9.96.2)
P/fixing aluminium tower bolts ISI marked anodised (Anodic coating not less than grade AC 10 as per IS:1868)transparent or dyed to required colour or shade with nuts and screws etc. complete: (200x10mm) (DSR item No. 9.97.3)
P/fixing aluminium tower bolts ISI marked anodised (Anodic coating not less than grade AC 10 as per IS:1868)transparent or dyed to required colour or shade with nuts and screws etc. complete: (150x10mm) (DSR item No. 9.97.4)
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary scerews etc. complet: 125mm (DSR item No. 9.100.1)
Providing and fixing aluminium floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) etc. complet: Twin rubber stopper. (DSR item No. 9.101.2)
Providing and fixing in position collapaible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with botts, nuts locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. (DSR item No. 10.3)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and comers, all necessary fittings complete, including applying a priming coat of aproved steel prmer. (Usingflats 30 x6mm for diagonal braces and central cross piece.) (DSR item No. 10.5.2)
Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover (DSR item No. 10.6.1)
Providing and fixing ball bearing for rolling shutters. (DSR item No. 10.7)
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area (DSR item No. 10.8.1)
steel work welded in built up sections/ framed work including cutting, hoisting fixing in position and applying a priming coat of approved steel primer susing structural steel etc. as required. (In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.) for raillings etc. (DSR item No. 10.25.2)
Cement concrete flooring 1:2:4 (1 cement : 2coarse sand : 4 gradd stone aggregate) finished with a floating coat of neat cement including cement slurry, (40 mm thick with 20mm nomnal sxe stone aggregate). (DSR item No. 11.3.1)
Providing/fixing glass strips in joints of terrazo/cement concrete floors. (40mm wide and 4mm thick) (DSR item No. 11.13.1)
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS: 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile. (DSR item No. 11.21.1.1)
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by E/I over 20mm (average) thick base of cement mortar 1:4 ( 1cement: 4coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete with: (Raj Nagar plain). (DSR item No. 11.23.1)
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigement to match the shade of the slab including rubbing and polishing omplete with base of cement mortar 1:4 (1 cement: 4 coarse sand): 25mm thick. (DSR item No. 11.26.1)
Kota stone slabs 25mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (avg.) thick cement mortar 1:3 (1cement : 3 c.sand )incl. rubbing and polishing complete. (DSR item No. 11.27)
Extra for pre finished noising in treads of steps of Kota stone/sand stone slab. (DSR item No. 11.31)
P/F Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacture) of approved make in all colours, s@ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR item No. 11.36)
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS; n 20 mm thick Cement Mortar 1:4 ( 1 cement :4 Coarse sand ) (DSR item No. 11.37)
Providing and laying polished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption,s less than 0.08% and conforming to IS 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) including grouting the joints with white cement and matching pigments etc, complete. (size of Tile 60x60cm) (DSR item No. 11.41.2)
Providing and laying pressed clay tiles (as per approved pattem 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 ( 1 cement :4 coarse sand) mixed with 2% integral water prooling compound laid over a bed of 20 mm thick cement mortar 1:4 ( 1cement:4c/sand ) and finished neat complete. (DSR item No. 12.20)
Providing and fixing 100mm diameter and 60cm long rain water spolut in cement mortar 1:4 (1cement ;4fine sand).(DSR item No. 12.37.1)
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concreete blocks 10x10x10cm of 1:2:4mix (1 cement:2coarse sand:4graded stone aggregate 20mm nominal size) and cost of cutting holes and making good the walis etc. (100 mm diameter). (DSR item No. 12.38.1)
P/F on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 (i) Single socketed pipes (75mm diameter) (DSR item No. 12.40.1)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointin with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes (110mm diameter) (DSR item No. 12.41.2)
12mm cement plaster of mix: 1:6 (1cement :6coarse sand) (DSR item No. 13.4.2)
12mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1cement : 4coarse sand) (DSR item No. 13.7.2)
Add or deduct of plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR item No. 5.30)
Providing/applying plaster of paris putty of 2mm th. over plastered surface to prepare the surface even and smooth complete. (DSR item No. 13.26)
Distempering with oil bound washable distemper of app. brand and manufacture to give an enen shade . New work (two or more coats ) over& incl. priming coat with cement primer. (DSR item No. 13.41.1)
Finishing walls with water proffing cement paint on required shade: New work (Two or more coats applied @ 3.84kg/10sam0 (DSR item No. 13.44.1)
Finishing wall with textured exterior paint of required shade: New work (two or moar coats applied @ 3.28 ltr/10sqm over and including base coat of water proofing cement paing applied @2.20kg/10sqm. (DSR item No. 13.45.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved prand and manufacture. (DSR item No. 13.62.1)
Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work (DSR item No. 13.64.1)
Forming groove of uniform size from 12x12mm and upto 25x15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges o plaster panel and finishing the groove complete as per specifications and direction of the E/I. (DSR item No. 13.76)
Renewing glass panes, with putty and nails wherever necessary . Float glass panes of thickness 4mm (DSR item No. 14.5.1)
Supplying and stacking at site.Good earth (DSR item No. 16.3.9)
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast lron P or S trap. 10 litre low level white P.V.C. flushning cistem with manually controlled device (handle lever ) conforming to IS: 7231, with all fitting and fixtures complete including cutting adn making good the walls and floors wherever required: White Vitreous china Orissa patern W.C. pan of size 580x440mm with integral type foot rests. (DSR item No. 17.1.1)
Providing and fixing white vitreous china pedestal type water closet (European tyope W.C. pan) with seat and lid , 10 litre low level white P.V.C. flushing cistern with manually controlled decice (handle lever), conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid (DSR item No. 17.2.1)
Providing and fixing wash basin with C.I. brackets 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets cutting and making good the walls wherever require: White Vitreous china Flat back wash basin size 550x400mm with a pair of 15mm C.P. brass pillar tap. (DSR item No. 17.7.4)
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR item No. 17.24)
Providing /fixing 600x450mm beveled edge mirror of superior glass (of approved quality ) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws & washers complete. (DSR item No. 17.31)
Providing anf fixing soil, waste and vent pipes: 100mm dia( Sand cast iron S&S pipe as per IS:1729) (DSR item No. 17.35.1.1)
Providing anf fixing soil, waste and vent pipes: 75mm diameter: ( Sand cast iron S&S pipe as per IS:1729) (DSR item No. 17.35.2.1)
Providing/fixing the joints with spun yam cement slurry and cement mortar 1:2 ( 1cement:2fine sand ) in S.C.I/C.I. pipes: 75mm dia pipe (DSR item No. 17.36.1)
Providing and fixing the joints with spun yam cement slurry and cement mortar 1:2 ( 1cement:2fine sand ) in S.C.I/C.I. pipes: 100mm dia pipe (DSR item No. 17.36.2)
Providing and fixing M.S. holder-bat clamps of approved design to Sand cast iron/cast iron(spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4mix( 1cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 75mm dia. pipe. (DSR item No. 17.37.2)
Providing and fixing terminal guard: :75mm (Sand cast iron S&S as per IS- 1729) (DSR item No. 17.56.2.1)
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 100mm (DSR item No. 17.58.1)
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 75mm (DSR item No. 17.58.2)
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P. brass screws with concealed fitting arrangement of approved quality an colour. 450mm long towel rail with total length of 495mm 78mm wide and effective height of 88mm, weighing not less than 170gms. (DSR item No. 17.73.1)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps including cutting and making good the walls etc. Internal work -Exposed on wall. 15mm dia. nominal bore (DSR item No. 18.10.1)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps including cutting and making good the walls etc. Internal work -Exposed on wall. 20mm dia. nominal bore (DSR item No. 18.10.2)
Concealed pipe including painting with anti corrosive bitumasiic paint cutting chases& making good the wall . 15mm dia nominal bore (DSR item No. 18.11.1)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15mm dia nominal bore (DSR item No. 18.12.1)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20mm dia nominal bore (DSR item No. 18.12.2)
Constructing masonry Chamber 30x30x50 cm inside with 75 class designation brick work in cement mortar 1:4 (1cement : 4coarse sand) for stop cock with C.I. surface bozx 100x100x75mm (insside) with hinged cover fixed in cement concrete slab 1:2:4 mix ( 1cement : 2coarse sand: 4 graded stone aggregate 20mm nomnal size) necessary excavation foundation concrete 1:5:10( 1cement:5fine sand :10 graded stone aggregate 40mm nominal size) and inside plastering with cemnt mortar 1:3 (1cement:3coarse sand ) 12mm thick finsished with a floating coat of neat cement complete as per standard design . With F.P.S. bricks (DSR item No. 18.32.1)
Providing and placing on terrace (at all floor levels) polyethylene water stonrage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for nilet, outlet and overflow pipes but without fittings and the base support for tank. (DSR item No. 18.48)
Providing anf fixing C.P. brass bib cock of approved quality conforming to IS: 8931 (15mm nominal bore). (DSR item No. 18.49.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 a(15mm nominal bore) (DSR item No. 18.53.1)
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, thight of 75mm with concealed fitting arrangements. Weighing not less than 106gms (DSR item No. 18.65)
Providing and fixing aluminium work for doors, windows ventilators and partitions with extruded built up standard tubular sections/ approprate Z ections and other sections of approprate make conforming to IS: 733 and IS: 1285 fixed with rawl plugs and screws of with fixing clips or with expanision hold fasteners including necessary filling up of gapu at junctions at top bottom and sides with required PVC/ neoperene felt etc. For fixed portion. (DSR item No. 21.1.1.2)
Providing and fixing aluminium work for doors, windows ventilators and partitions with extruded built up standard tubular sections/ approprate Z ections and other sections of approprate make conforming to IS: 733 and IS: 1285 fixed with rawl plugs and screws of with fixing clips or with expanision hold fasteners including necessary filling up of gapu at junctions at top bottom and sides with required PVC/ neoperene felt etc. : For shutters of doors windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required (DSR item No. 21.1.2.2)
Providing/fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle borad conforming to IS: 12823 Grade I Type II in panelling fixied in aluminum doors windows sutters and partition frames with C.P. brass/ stainless stell screws etc. (DSR item No. 21.2.2)
Providing and fixing glazing in aluminium door, window ventilator shutters and partitons etc. with PVC/ neoprene gasket etccomplete as per the architectural) With flot glass panes of 5.50mm thickness (DSR item No. 21.3.2)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness (DSR item No. 21.4.1)
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. (DSR item No. 21.13)
Providing fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge.Powder coated minimum thickness 50 micron aluminium (DSR item No. 21.16.2)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. pipe. (DSR item No. 19.6.4)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable 1.5 sqmm FR PVC insulated copper conductor single core cable etc as requited. GROUP B (DSR item No. 1.1.2)
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (DSR item No. 1.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required Circuit / sub main wiring in PVC codute 2*1.5 Sq.M*1*1.5 Sq.M (DSR item No. 1.7.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ sub main wiring in PVC codute 2*2.5 Sq.M*1*2.5Sq.M (DSR item No. 1.7.2)
S/F stepped type electronic fan regulator on the existing moduler plate switch box incl.connection but excluding moduler plate etc.required. (DSR item No. 1.25)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (DSR item No. 1.29)
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. (DSR item No. 1.30)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. (DSR item No. 1.41)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., incl.s/f ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable earthing etc. as required. (DSR item No. 1.42)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (DSR item No. 1.45)
S/ fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Single door (DSR item No. 2.45.1)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. (DSR item No. 5.5)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)2 + 6 way/ 8 way , Double door (DSR item No. 2.3.6)
S/F 5amp to 32amp rating 240 volts,B series,MCB suitable for lighting and other loads of single pole in the existing MCB D.B complete with connection ,testing and commissioning etc. as required. Single pole (DSR item No. 2.10.1)
S/F 5amp to 32amp rating 240 volts,B series,MCB suitable for lighting and other loads of single pole in the existing MCB D.B complete with connection ,testing and commissioning etc. as required. Double pole (DSR item No. 2.10.3)
Supply of factory wired HPF box type 1x40 Watt flurescent tube fitting of approved quality ( Bajaj,Havells or equilent make) with requisite accessories like electronic ballast, Tube etc. complete. (NSI)
Supply of 1200 mm sweep ceiling fan of approved quality ( Bajaj,USHA, Havells or equilent make) without regulator. (NSI)
Supply of 300 mm sweep ventilating fan of approved quality ( Bajaj, USHA, Havells or equilent make) without regulator. (NSI)
Land development
Earth work in excavation by mechanical means (Hydraulic excavator ) manual means in foundation tranches (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. (All kinds of soil). (DSR item No. 2.8.1)
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5m (DSR item No. 2.25)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. (DSR item No. 2.31)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (DSR item No. 4.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level:1:4 :8 (1 Cement :4 coarse sand: 8 graded stone aggregate 40 mm nominal size) (DSR item No. 4.1.8)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 cm nominal size). (DSR item No. 5.1.2)
Reinforced cement concrete work in walls (any thickness),including attached pillasters,buttresses,plinth and string courses, fillets, columns, pillars,piers,abutments,posts and struts etc. upto floor five levels,excluding cost of centering,shuttering,finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (DSR item No. 5.2.2)
Reinforced cement concrete working beams, suspended floors, roofs having slope up to 1.5 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral/ stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). (DSR item No. 5.3)
Centering and shuttering including strutting propping etc. and removal of form for: Lintels, beams, plinth beams girders, bressumers and cantilevers, (DSR item No. 5.9.5)
Centering and shuttering including strutting propping etc. and removal of form for:Columns,Pillars,Piers,Abutments,Posts and Struts. (DSR item No. 5.9.6)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. (TMT bars ). (DSR item No. 5.22.6)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.1.2)
Brick work with F.P.S. Bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) (DSR item No. 6.4.2)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) (DSR item No. 6.13.2)
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR item No. 10.16.1)
steel work welded in built up sections/ framed work including cutting, hoisting fixing in position and applying a priming coat of approved steel primer susing structural steel etc. as required. (In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.) (DSR item No. 10.25.2)
12mm cement plaster of mix: 1:6 (1cement :6coarse sand) (DSR item No. 13.4.2)
15mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1cement :6coarse sand) (DSR item No. 13.5.2)
Finishing wall with textured exterior paint of required shade: New work (two or more coats applied @ 3.28 ltr/10sqm over and including priming coat of exterior primer applied @2.20kg/10sqm. (DSR item No. 13.45.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved prand and manufacture. (DSR item No. 15.2.1)
Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) verendah and etc. (DSR item No. 15.2.1)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR item No. 15.7.4)
Engaging suitable Beldar for petty works (DSR item No. 114)
Stone tile work for wall lining upto 10m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade. (i) 12mm thick stone Textured Exterior cladding tiles. (NSI)
Supplying and stacking at site.Good earth (DSR item No. 16.3.9)
CONSTRUCTION OF 33 KV UNDERGROUND EXISITING LINE AT Majraseela GADARPUR
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe at the depth of about 1meter as per site requirement & Cable dia including provision of cable route markers in CC casting etc. complete in all respect in the form original before digging.
33KV (E) XLPE HT cable 3x400sqmm
Supply and Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers without open excavation in HDPE pipe:
33KV (E) XLPE HT cable 3x400sqmm
Supply, erection, testing and commissioning of HT cable termination Kits / Straight through
33 KV (E) XLPE HT cable 3 x 400 sq.mm (Outdoor)
33kV Touch proof termination kits 3X400Sq MM (suitable for 33kV RMU) (Indoor)
33KV (E) XLPE HT cable 3x400sqmm (Straight thro)
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Road crossing, culverts, crossings, by side of bridges with support hangers, fastners, complete in all respects.
CIVIL WORKS
Making and casting of Manholes , wherever required for obervation/ monitoring the cable as per site requirement including CI heavy duty chamber
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .