Annual Plan completion work of Kulippura colony Watersupply Scheme S0178 26 General Electrical Work Retender
2026_LSGD_846985_5
AE/LID-EW/BPSBY/07/2025-26
Open Tender
Electrical Works
Item Rate
180 days
Sulthan Bathery
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹3,073
Yes
12 Mar 2026
12 Mar 2026
23 Mar 2026
12 Mar 2026
20 Mar 2026
12 Mar 2026
Electrical
OD449679/2025-2026:Supply, installation testing and commissioning of 5 HP Vertical open well submersible pump set 2880 rpm at rated voltage 3 phase 415V 50HZ AC supply at 16-74 Mtr head delivery size 50 mm or nearest size having 21.6 - 1.8 discharge and 4.5 LPS at 50 Mtrs head using leak proof materials as required and suspended on existing rope/steel rope including fixing G.I. / uPVC Column heavy duty Pipe for Submersible Pumps as delivery pipe connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary supports on both sides of the motor including giving connection as per the direction at site. (Texmo/CRI/Kirloskar/Deccan)
OD449678/2025-2026:Supply, Installation, Testing and Commisioning of DOL MUG Starter Panel for 5HP Submerssible motor comprising of Relay, LED Indicator, Voltmeter, Ammeter, Contactor, Capacitor etc as required. L&T
OD449680/2025-2026:Supply threading, laying and joining of 50 mm/nearest size Submersible Column/HDPE Pipe for submersible pump, approved make specials as delivery pipe using required leak proofing materials etc. as required.
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD449683/2025-2026:Supply and providing 50 mm/nearest size dia Gun Metal Non return valve (ISI)
OD449688/2025-2026:Supply and providing 50 mm dia Full way valve (ISI)
OD449681/2025-2026:Supply and providing 50 mm dia Flange set
OD449686/2025-2026:Supply and laying of 20mm or nearest size Nylon rope
OD449685/2025-2026:Supply and providing 50 mm stainless steel Hose Collar with hose clip
OD449689/2025-2026:Supply and fixing flat iron clamps made from 2 nos. 50x6 mm flat iron clamp of 50 mm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
OD449682/2025-2026:Supply and installation of dust and vermin proof Three-phase sintex motherboard (GS MB6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required
OD449687/2025-2026:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
OD449684/2025-2026:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
E178SBD.pdf
Tender Documents • 1.63 MB
BOQ_1431178.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .