Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹39.4 L | L1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L2₹47.4 L+₹8.0 L (20.2%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹47.4 L+₹8.0 L (20.2%) | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹48.1 L+₹8.8 L (22.2%)Rejected-Finance | ₹48.1 L+₹8.8 L (22.2%) | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹53.7 L+₹14.3 L (36.3%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | ₹53.7 L+₹14.3 L (36.3%) | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 5 | Rejected-Technical B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | - | - | Rejected-Technical The firm is not enlisted in category c(i) |
Tender Value
₹43.7 L
EMD Value
₹87,380
Closing Date
9 Apr 2024, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVN OF AIR CONDITIONERS ALONGWITH STABILIZERS AT OTM ACCN OF GANDHINAGAR AND PROVN OF CHEMICAL EARTHING AT OTM ACCN OF GANDHINAGAR UNDER GE (AF) CHILODA
2024_MES_641414_2
8986/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GANDHINAGAR
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹87,380
Yes
17 May 2024
26 Mar 2024
11 Apr 2024
26 Mar 2024
9 Apr 2024
3 Apr 2024
26 Mar 2024 - 2 Apr 2024
Amount
Supply , installation and testing for electric driven single phase HI wall Digital Inverter 4 -in-1 convertible 1.5 TR 5 star rating split AC, eco frIendly refrigerant with indoor & outdoor unit with copper condenser, cordless remote , 2 way air flow, anti-dust & anti-bacterial air filter, suitable size copper pipe upto 10 feet, mounting stand etc. complete all as specified and directed.
Supply , installation and testing for electric driven single phase HI wall Digital Inverter 4 -in-1 convertible 2.0 TR 5 star rating split AC, eco frendly refrigerant with indoor & outdoor unit with copper condenser, cordless remote, 2 way air flow, anti-dust & anti-bacterial air filter, suitable size copper pipe upto 10 feet mounting stand etc. complete all as specified and directed.
Supply & Fixing for wall mounted voltage stabilizer 12 Amp capacity single phase, naturally air cooled with volt meter, for automatic Low & High Voltage cut-off protection for input voltage of 150 V to 280V and output voltage stabilized between 230 V with accuracy of 2.5% fixing voltage stabilizer to wall complete all as specified and directed.
Supply & Fixing for wall mounted voltage stabilizer 15 Amp capacity single phase, naturally air cooled with volt meter, for automatic Low & High Voltage cut-off protection for input voltage of 150 V to 280V and output voltage stabilized between 230 V with accuracy of 2.5% fixing voltage stabilizer to wall complete all as specified and directed.
Supply, Fixing and testing for Auto change over digital timer switch 1 To 24 Hr’s programmable micro Controller Based Technology Split AC With Auto/ Manual Facility suitable for 2 Nos 2.0 TR air conditioner (for 24 hrs operation / for operation of standby AC) complete all as specified and directed.
Supply and fixing air conditioner copper pipe grade ASTM B280 suitable size for suction and discharge line of refrigerant gas complete including jointing and testing complete all as specified and directed.
S & F for nitrile rubber foam insulation pipe suitable for suction and discharge split air conditioner copper tube complete all as specified and directed.
S & F for Unplasticised PVC pipes 20 mm dia of pressure rating 6 kgf/cm2 ISI marked with tee, bend, coupler etc fixed on wall/ floor or as required as site for AC water drain pipe complete all as specified and directed.
S & F round PVC FRLS insulated stranded copper conductor 2.5 Sq mm, 4 core 1100 volt grade cable connected from indoor unit to out door unit of AC complete all as specified and directed.
Supplying and fixing of PVC standard sloted cable trunking of size 45 mm H x 60 mm W fixed to walls, ceilings etc with all fixing accesories complete all as specified and directed.
M&L for sub main wiring using four single core FRLS PVC insulated, unsheathed multi stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 Volts drawn in existing concealed PVC conduit or in surface conduit of dia not less than 25 mm with standard accessories, along-with one run of FRLS PVC (green colour) insulated , unsheathed, multi stranded copper conductor of size 10.0 Sqmm as earth continuity conductor complete all as specified and directed. (Note : four run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
Material & Labour for sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts drawn in in existing concealed PVC conduit or in surface conduit of size not less than 20 mm with standard accessories fixed on walls / ceiling surface along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm as earth continuity conductor complete all as specified and directed.
Material & Labour for sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including PVC casing capping of size not less than 20 mm with standard accessories fixed on walls / ceiling surface along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor complete all as specified and directed. (Note for item No 12 & 13 : two run of single core PVC cable with one run of earth conductor and if reqd surface conduit shall be measured as one unit.)
Supply & fixing sheet metal powder coated versatile double door Verticle TPN 4 way distribution system as per IS 8623 with copper bus bar rated 200 amps neutral link, earth bar and din rail etc suitable for use on 415 Volts, 50 Hz supply suitable for 3P/4P MCCB as incomer complete all as specified and directed.
Supply & fixing sheet metal powder coated versatile double door TPN 4 way distribution system as per IS 8623 with copper bus bar rated 200 amps neutral link, earth bar and din rail etc. suitable for use on 415 Volts, 50 Hz supply complete all as specified and directed.
Supply & Fixing industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 volts with including 20 Amp SP MCB complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of TPN current carrying capacity 32 to 63 AMP, 415V, 10 KA 'C' curve in the MCB DB Complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of TP and current carrying capacity 32 to 63 AMP, 415V, 10 KA 'C' curve in the MCB DB Complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of single poles with neutral (SPN) and current carrying capacity 16 to 32 AMP, 240V, 10 KA 'C' curve in the MCB DB complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, 240V, 10 KA 'C' curve in the MCB DB Complete all as specified and directed.
Supply and fixing for MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 35 KA fixed in V TPN MCB DB as incomer complete all as specified and directed.
M & L for chemical earthing with using copper earth plate of 900 x 600 x 5 mm buried directly in ground) Earth pit not less than 4.0 meter below the ground level with top edge of the earth plate at a depth not less than 3.25 meter below ground level connected to test point terminal test block by means of copper nuts, bolts, check nuts & washer etc with including necessary earth work and Pre- cast RCC earth pit and cover lifting arrangement and with two coat red paint including marking the chamber as earth pit with writing of inspection test & earth result with black & white paint complete all as specified and directed. note: The rate quoted shall deemed to be inclusive of the followings. a). Excavation & earth work ( filling in, ramming in layers, watering etc as directed)in any type of soil for earth pit of size 1.2 meter X 1.2 meter X 4 meter deep. (b) 20 mm bore mild steel galvanised iron tubing light grade with funnel for watering purpose complete. (c) 40mm bore mild steel galvanized iron tubing light grade for strip protection (d) main cooper earth strip 32 x 6 mm upto 7.5 meter long or upto earth test point (f) common salt and charcoal dust in alternative layers of 15 cm up to 90cm above the top of copper plate & one layer of 15cm magnesium sulphate, ( approximate quantity of salt 500kg, charcol dust 1000kg, magnesium sulphate150 Kg, 100 Kg soil resistivity improvement powder/ GEL) complete all as specified and directed (g) Earthing earth testing value should be less than 1.0 Ohm and this should be the sole responsibility of contractor.
M & L for 32 x 6 mm copper earth strip continuity conductor or main earthing lead with saddles, insulators and fixing screws etc on wall or recess or buried in ground or drawn in conduit or any other indicated situation for loop earthing complete all as specified and directed.
M & L for 20 x 3mm copper earth strip continuity conductor or main earthing lead with saddles, insulators and fixing screws etc on wall or recess or buried in ground or drawn in conduit or any other indicated situation for loop earthing complete all as specified and directed.
S & F for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
ALBA AC AND REF SERVICES
Dighard Electricals
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .