| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.9 LAccepted-AOC | L1 | Accepted-AOC L1 Contract value | |
| 2 | L2₹83.8 L+₹4.9 L (6.23%)Rejected-Finance | L2 | Rejected-Finance L2 bidder |
Tender Value
₹90.2 L
EMD Value
₹50,000
Closing Date
27 Nov 2024, 3:00 pmClosed
Man aging Director
MM Gardens Church Landing Road Pallimukku Ernakulam
Development of Taluk Hospital Parassala MGPS work
2024_KITCO_700867_1
HFWD/KITCO/CL/12/2024
Open Tender
Civil Works - Others
Item Rate
90 days
Parassala
As per Tender
5 documents required · 5 mandatory
₹2,950
Yes
₹50,000
Yes
KITCO Ltd
14 Feb 2025
30 Oct 2024
29 Nov 2024
30 Oct 2024
27 Nov 2024
8 Nov 2024
30 Oct 2024 - 4 Nov 2024
6 Nov 2024
Amount
od156147/2023_2024 : Supply,testing and commissioning of Automatic Oxygen Control Panel with minimum flow rate of 1500 LPM Fully complying with ISO 10524-2, ISO 7396-1:2007/HTM02-01 as per technical specifications. The cylinders shall not be included in the quoted price.
od156148/2023_2024 : Supply,testing and commissioning of Oxygen Manifold - 2 banks x10 cylinders, as per technical specifications. The cylinders shall not be included in the quoted price.
od156149/2023_2024 : Supply,testing and commissioning of Cylinder Emergency Oxygen Manifold - 1 Bank x5 Cylinders wih high flow regulator, The cylinders shall not be included in the quoted price.
od157626/2023_2024 : NITROUS OXIDE SYSTEM: Supply,testing and commissioning of automatic N2O control panel complete set with inlet and outlet connectors for fully automatic control panel for both sides with brass hosing and suitable connectors. ½ BSP (M) thread.
od157627/2023_2024 : Supply,testing and commissioning of Nitrous Oxide Manifold - 2 banks x 2 cylinders.as per technical specifications. The cylinders shall not be included in the quoted price.
od157628/2023_2024 : Supply,testing and commissioning of Emergency N2O Out let with Convertion Kit (Convertion Kit- 2nos)
od156231/2023_2024 : Supply,testing and commissioning of semi automatic CO2 control panel complete set with inlet and outlet with brass housing and suitable connectors.12 BSP (M) thread.
od156232/2023_2024 : Supply,testing and commissioning of Cylinder CO2 Manifold - 1cylinder x 2bank with all accessories required as per specification.
od172568/2023_2024 : Supply,testing and commissioning of Emergency CO2 Out let with Convertion Kit (Convertion Kit- 2nos)
od156233/2023_2024 : MEDICAL AIR SYSTEM: Supply,testing and commissioning of Compressed air plant complete with - 2 compressors, each compressor should have minimum free air delivery of 1020 LPM, 1 air receiver-2000 ltrs, 2 air purification system to ensure medical air quality as per HTM 02-01 guidelines, pressure reducing station, control panel, automatic drain valves, ball valves etc and as per technical specifications.
od156234/2023_2024 : VACUUM PLANT: Supply,testing and commissioning of Vacuum plant complete with 1 vacuum pump and one as standby, each vacuum pump should have minimum free air aspirated of 2900LPM betwen 570 mmHg and 720 mm Hg.min, vaccum receiver tank of minimum 3000ltr capacity,bacteria double filter, valves,pressure guages,NRV, electrical control panel including circuit breakers, pressure switches, timers, ball valves etc as per technical specifications.
od156235/2023_2024 : "Supply,testing and commissioning of Master Plant Alarm Panel ,Complies with HTM 02-01/ISO<br>7396-1 Standards. Each Master Alarm should be modular in design and be fitted with required number of master alarm modules. The master alarms should be capable to monitor minimum 25 point. Each point represents an alarm condition that the source equipment might have. When an alarm condition exists, a red-light flashes and the audible alarm sounds. If several alarm conditions occur simultaneously, the most recent alarm light should flash, while the other alarm lights should remain lit. When an alarm condition is generated, an audible alarm should be actuated. A dry contact module should be available to interface with a building management system. The box material should be of gauge steel of requisite thickness and equipped with mounting brackets. The emissions from alarms should conform with EMC standards. Master alarm management system should be designed to display alarm conditions from the source supply units indicating the broad status of the source equipment and manifolds as well as the master distribution status from the source supplies. Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. Each panel shall display and/or input of multi point alarms,including all necessary cabling between mater alarm and floor panels. The master alarm must be able to monitor the following source alarm conditions. as per technical specifications.
od156236/2023_2024 : Combined Electrical Control panel with wiring for Air compressor & vaccum Pump system as per technical specification.
od157636/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-12mm x 0.7 mm thick copper pipe.
od157637/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-15 mm x 0.9 mm thick copper pipe.
od157638/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications.
od157639/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-28 mm x 0.9 mm thick Copper pipe.
od157640/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-35 mm x 1.2 mm thick Copper pipe.
od157641/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-42 mm x 1.2 mm thick Copper pipe
od156237/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-O2 Outlets with Probes
od156238/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-N2O Outlets with Probes
od156239/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications- Air ( 4 bar) Outlets with Probes
od156240/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Air (7 bar) Outlets with Probes
od156241/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Vac (7 bar) Outlets with Probes
od156244/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-3 gas - 1 O2, 1M air, 1 Vac
od156246/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-5 gas- 1O2,1 N2O, IM air , 1 s air, 1 vac
od156247/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-6 gas- 1O2,IM air,1 N2O, 1 s air, 1 vac
od156248/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-15 mm
od156249/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-22 mm
od156250/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-28mm
od156251/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-35 mm
od156252/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-42 mm
od156253/2023_2024 : Supply,testing and commissioning of class J type Oxygen Gas filled Cylinder etc in complete as per technical specification.
od156254/2023_2024 : Supply,testing and commissioning of J type Nitrous Oxide Gas filled Cylinder as per technical specification.;
od156255/2023_2024 : Supply,testing and commissioning of J type CO2 Gas filled Cylinder as per technical specification.
od156707/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge.
od156708/2023_2024 : Supply Installation of BPC Oxygen Flow meter as per technical specification.
od156150/2023_2024 : Supply Installation of Ward vacuum unit with 600 ml collection jar asper technical specification.
od156151/2023_2024 : Supply Installation of Theatre Vacuum unit with trolly and 2000 ml collection jar as per technical.
od156154/2023_2024 : BHP Suction Clamp
od156155/2023_2024 : BHP IV Stand
od156156/2023_2024 : BHP Monitor Tray
od156157/2023_2024 : Supply,Installation,testing and commissioning of High Pressure Antistatic Hose with color coded.
Blaze Systems and Services (BID ID -1976413)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .