Loading…
Loading…
Tender ID
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
4 May 2026, 5:30 amClosed
Barrackpore Division
HINDUSTAN AERONAUTICS LIMITED Barrackpore Division Barrackpore Post Parganas (N) , Dist. 24 W. Bengal - 700 120 Phone : 2592-0157/2592-0163 Fax No : 91-033-2592-2379
ELECTRICAL, I.T. AND FIRE DETECTION AND ALARM SYSTEM WORKS FOR G PLUS 1 ANNEX BUILDING OF ASSEMBLY HANGAR AT HAL BARRACKPORE DIVISION.
25377
HAL/BKP/NIT/ELECT/824/2026 Dt. 25-03-2026
Limited
Works
Helicopter Complex -Barrackpore Divn-PM-Cheetah-Chetak-Plant Maintenance-Electrical
| # | Company Name | Location | Address |
|---|---|---|---|
| 1 | Origin Techserve Pvt Ltd | Chennai,India | New No 124, Old No 74, 3rd Floor,,Sri Balaji Towers, Mount Road, Guindy, Chennai,Chennai,Tamil Nadu,India,Pin-600032 |
| 2 | VICOM SECURITY PVT LTD | KOLKATA,India | 8 BECK BAGAN ROW,,KOLKATA,West Bengal,India,Pin-700017 |
| 3 | DG Micropronix Pvt Ltd | Kolkata,India | Royal Plaza, 3 Feeder Road, Rathtala, Belgharia,,Kolkata,West Bengal,India,Pin-700056 |
| 4 | EVEREST ELECTRO MECH ENGINEERS | LUCKNOW,India | 3/212,SEC H JANKIPURAM,LUCKNOW,Uttar Pradesh,India,Pin-226021 |
| 5 | Vishal Technopower Private Limited | TEST,India | TEST,,TEST,Uttar Pradesh,India,Pin-201001 |
Origin Techserve Pvt Ltd
Chennai,India
New No 124, Old No 74, 3rd Floor,,Sri Balaji Towers, Mount Road, Guindy, Chennai,Chennai,Tamil Nadu,India,Pin-600032
VICOM SECURITY PVT LTD
KOLKATA,India
8 BECK BAGAN ROW,,KOLKATA,West Bengal,India,Pin-700017
DG Micropronix Pvt Ltd
Kolkata,India
Royal Plaza, 3 Feeder Road, Rathtala, Belgharia,,Kolkata,West Bengal,India,Pin-700056
EVEREST ELECTRO MECH ENGINEERS
LUCKNOW,India
3/212,SEC H JANKIPURAM,LUCKNOW,Uttar Pradesh,India,Pin-226021
Vishal Technopower Private Limited
TEST,India
TEST,,TEST,Uttar Pradesh,India,Pin-201001
₹0
₹3.8 L
4 May 2026
31 Mar 2026
31 Mar 2026
4 May 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
Goods & Service Tax Registration No
Format of Undertaking
PAN No.:
Electrical Licence.:
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Average annual financial turn over during the last 3 years, ending 31st March of the previous financial year [ should not be less than 30% of Amount put to tender] [The Annual Turnover figure should be excluding miscellaneous incomes etc. and same as per Profit & Loss statement duly certified by Chartered Accountant with UDIN]
TURN OVER IN Rupees
Enclosed
Enclosed
Enclosed
ESI & PF Nos with proof (If any)
Related Document to be Uploaded to e-procurement Portal
Bank(s) details: [Copy of the cancelled cheque leaf to be uploaded]
Related Document to be Uploaded to e-procurement Portal (Note Cancelled cheque leaf to be uploaded)
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender Notice. [SOLVENCY CERTIFICATE AS PER ENCLOSED FORMAT IN TENDER DOCUMENT TO BE UPLOADED]
Pls Enter Details of 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending last day of previous month. [Latest work experience certificate may be uploaded] [WORK COMPLETION CERTIFICATE AS PER ENCLOSED FORMAT IN TENDER DOCUMENT TO BE UPLOADED] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
40% (Three Works)
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
work done
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION :
Pls Accept The Declaration
DECLARATION II
Pls Accept the Delaration II
It is an express condition that the tenderers are advised to visit the site before qouting to ascertain the scope of work involved.No extra claims will be entertained later.
The work has to be carried out in Co-ordination with Engineer In-Charge(EIC)for minimum power interuptions and shutdowns if any required shall be intimated to EIC in advance in writing for smooth coordination work.Also preparation work if any required has to be carried out as directed by EIC without any additional cost during execution.
Basic rate to be quoted for each item.Subject work is called on works contract basis and prevailing GST as applicable for each item to be mentioned in the coloumn for GST .Tenderers must abide by the prevailing GST rules.
L1 will be determined including GST (on Package basis)
The Tenderer shall be deemed to have examined the Tender documents-PART A for Instruction to tenderers,General Condition of Contract,Special Conditions of Contract,Safety requirements,List of Approved make of Materials and Equipments etc. before quoting .
Description
Supplying and fixing 8 way (4+24),surface/recess mounted vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's ( but without MCB's and incomer ) as required.
Supplying and fixing 12 way (4+36),surface/recess mounted vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's ( but without MCB's and incomer ) as required.
Supplying and fixing 8 way, Double Door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
Supplying and fixing 12 way, Double Door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
Supplying and fixing 100 amps 4P MCCB,with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
Supplying and fixing 125 amps 4P MCCB,with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 amps, double pole, (single phase and neutral), 240 volts,10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 amps, double pole, 240V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 amps, double pole, 240V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and drawing 3 core 2.5 sq.mm of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying and drawing 3 core 2.5 sq.mm of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Indoor terminal Termination jointing of 3.5 core 185 sq.mm PVC/Aluminium Cable by compression type brass cable gland, crimping type sockets, tapes etc complete.
Indoor terminal Termination jointing of 3.5 core 95 sq.mm PVC/Aluminium Cable by compression type brass cable gland, crimping type sockets, tapes etc complete.
Indoor terminal Termination jointing of 3.5 core 35 sq.mm PVC/Aluminium Cable by compression type brass cable gland, crimping type sockets, tapes etc complete.
Indoor terminal Termination jointing of 4 core 16 sq.mm PVC/Aluminium Cable by compression type brass cable gland, crimping type sockets, tapes etc complete.
Indoor terminal Termination jointing of 4 core 6/10 sq.mm PVC/Aluminium Cable by compression type brass cable gland, crimping type sockets, tapes etc complete.
Indoor terminal Termination jointing of 3 core 6/10 sq.mm PVC/Aluminium Cable by compression type brass cable gland, crimping type sockets, tapes etc complete.
Supplying and fixing 100mm wide X 50mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and fixing 150mm wide X 50mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and fixing 300mm wide X 50mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and fixing 450mm wide X 50mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and fixing 600mm wide X 50mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (GROUP C)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular switch, suitable M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(Circuit length from DB to Thermal Sensor,MCB controlled lights from Sensor)
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (6A+16A Primary Point + Loop)
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.(Circuit length DB to 16A Primary Point & 16A Loop)
Supplying and fixing 5/6 A switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 15/16 A switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 6 pin 15/16 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supply and fixing one module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following 1 or 2 Module (75mmX75mm)
Supplying and fixing following 3 Module (100mmX75mm)
Supplying and fixing following 4 Module (125mmX75mm)
Supplying and fixing following 6 Module (200mmX75mm)
Supplying and fixing following 8 Module (125mmX125mm)
Supplying and fixing following 12 Module (200mmX150mm)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modus protocol ie. Supplying communcation linnks between building management system and fire alarm control panel cpmlete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying and drawing 4 x 1.5 sq. mm of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying and fixing following 1 or 2 Module (75 mm x 75 mm) / modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
Supplying and fixing following Telephone Socket outlet modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required
Supply and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :
Supply and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :
Supply and drawing 2 pair, 0.5 sq.mm. FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. make:- (Molex/Schneider/Tyco)
Supplying and drawing following 12 Core Single Mode OS2 10G Outdoor Armored Fiber Optic Cable,Single loose tube,Gel filled . Sequencial meter marking on cable. Armoring: 0.15mm corrugated steel tape. Sheath: LS0H. Standards: IEC 60793-1-40 , ISO 11801, Telecordia GR-20, RoHS Compliant. (Make:Molex/Schneider/Tyco)
Supply and drawing 20 pair, 0.5 sq.mm. FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required.
Supplying and fixing of 15U Rack Wall Mount 19" Telco Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. Make:- SCHNEIDER/VERTIV/Valrack/Netrack/APW
Supplying and fixing 24U Rack withminimum 800 mm x 1000 mm with 5mm thick glass Glass Door in Front,complied with UL & RoHS. 2 nos power distribution units, 1 number cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. Should Have Side Panel Mount Air conditioner with minimum 1000W of cooling power. Air-conditioning unit should be designed specifically to cool & partially dehumidify the internal environment of Electrical/Electronic devices. Rack should be Thermally insulated. The Panel AC unit should consist of evaporator fan,condenser coil, evaporator coil (Hydrophilic coated ), drier filter in refrigerant piping section . The controller of the unit should be Microprocessor based and support RS485 protocol enabling the unit to connect with the monitoring system for remote monitoring Should work in Ambient Temperature Range from 10°C to 50°C and should maintain atleast 24°C in said Ambient Temperature Range. Refrigerant : R134A (Eco-friendly) The unit should consist of the PTC heater-based Condensate evaporator which must evaporate the condensate water & eliminate the requirement of separate drainage point connection to the Panel AC Unit. Air conditioner should assure cool & clean atmosphere essential for electronic circuitry. The hot air generated inside the electronic cabinet is drawn into the AC through a blower where the evaporator coil placed. The hot air, which passes through the evaporator coil, gets cooled and is discharged into cabinet. Should have capability to run 24hrs x 365days Proposed system should made such way that it can be easily dismantled and relocated to different location along with All the components of the said infrastructure. Propsed Rack & Air conditioner should operate in Single Phase 220V AC power supply. Separate Power Input Cable with plug with MCB protection and other necessary accessories should be given to run/operate the Rack & Air conditioner. All the components should be from same OEM. Make:- Make:- SCHNEIDER/VERTIV/Valrack/Netrack/APW
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panelshould have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. make:- Molex/Schneider/Tyco)
Supply and fixing following Rack Mount LIU 24 PORT FULLY LOAD LIU Port type : LC Connector Pigtail : Single Mode OS2 10G Mount: 1U height , 19" Rack mountable (Make:Molex/Schneider/Tyco)
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. 10G SFP+ LC Duplex LR transceiver (10Gb UP TO 10KM) for SM OS2 Fibre Optics Cable. Must be hot Pluggable, RoHS Complaint, etc. complete as required. It should be same make as the offered network switch and should be compatible with offered FO. MAKE: (Cisco/HP/Nortel/Juniper/Allied Telesis)
Supply Installation Testing and commissioning of 12 port SFP+ L2/L3 Switch Intranet. Switch having minimum 12Nos. 10G SFP+ slots Switching Capacity should be atleast 240Gbps Packet Forwarding Rate should be atleast 150 Mpps. The Switch should have following L2 features: 1.Min 8000 MAC address supported 2. Flow Control: IEEE 802.3x in full duplex. 3. IEEE802.1D STP, 802.1w RSTP,802.1s MSTP. 4.Should support IEEE 802.3ad 5.IEEE 802.1x Port based Network access control. 6.Should support IEEE 802.1Q VLAN. 7.Should support service restoration time <100 ms after a station or link failure. 8.The switch should have IEEE 802.1p. Support . The switch should have support for standard & extended Access control lists. The Switch should have following Management features: Command line interface,Web browser interface,configuration menu,RMON,Full SNMP Management Information base.(v1,v2c and v3) Auto discovering on physical and logical basis. Should support the discovery of device from L2 to L3 devices. Switch should support firmware upgrade using web. The switch should have energy saving technology based on IEEE 802.3az or equivalent The switch should be 1U height Power Supply : 220v AC operated Integrated/Modular single/dual PSU MAKE: (Cisco/HP/Nortel/Juniper/Allied Telesis)
Supplying, Installation, Testing and commissioning of 24 port L2 Gigabite Switch with 4 SFP+ Port Intranet. L2 Managed Switch having 24x10/100/1000BaseT ports & 4x1G SFP slots Switching Capacity should be atleast 56Gbps Packet Forwarding Rate should be atleast 41 Mpps. The Switch should have following L2 features: 1.Min 8000 MAC address supported 2. Flow Control: IEEE 802.3x in full duplex. 3. IEEE802.1D STP, 802.1w RSTP,802.1s MSTP. 4.Should support IEEE 802.3ad 5.IEEE 802.1x Port based Network access control. 6.Should support IEEE 802.1Q VLAN. 7.Should support service restoration time <100 ms after a station or link failure. 8.The switch should have IEEE 802.1p. Support . The switch should have support for standard & extended Access control lists. The Switch should have following Management features: Command line interface,Web browser interface,configuration menu,RMON,Full SNMP Management Information base.(v1,v2c and v3) Auto discovering on physical and logical basis. Should support the discovery of device from L2 to L3 devices. Switch should support firmware upgrade using web. The switch should have energy saving technology based on IEEE 802.3az or equivalent The switch should be 1U height Power Supply : 220v AC operated Integrated/Modular single/dual PSU MAKE(Cisco/HP/Nortel/Juniper/Allied Telesis)
Supplying, Installation, Testing and commissioning of 1G SFP LC Duplex LR transceiver for SM OS2 Fibre Optics Cable) FOR INTERNET. It should be same make as the offered switch. MAKE(Cisco/HP/Nortel/Juniper/Allied Telesis)
Supplying, Installation, Testing and commissioning of length 3m LC-LC Duplex Single Mode OS2 10G FO Patch Cord.
Supplying, Installation, Testing and commissioning of CAT6 Copper Patch Cords of length 1meter Conductor:24AWG standard copper wire Sheath: PVC RJ45 Plug : Clear Polycarbonate UL94V-0 RJ45 plug Compliants: ISO/IEC 60603-7 and FCC 47 Part 68 Standards: ISO 11801, TIA-568-C.2, UL1863,UL444,RoHS Compliant (Make:Molex/Schneider/Tyco)
Supplying, Installation, Testing and commissioning of CAT6 Copper Patch Cords of length 2meter. Conductor:24AWG standard copper wire Sheath: PVC RJ45 Plug : Clear Polycarbonate UL94V-0 RJ45 plug Compliants: ISO/IEC 60603-7 and FCC 47 Part 68 Standards: ISO 11801, TIA-568-C.2, UL1863,UL444,RoHS Compliant (Make:Molex/Schneider/Tyco)
Supplying Installation Testing and Commissioning of 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens
08 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9, 2nd screen: 1/4/8/9
16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
Supplying, Installation, Testing and Commissioning 8TB (Terabytes) capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC,KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
Supplying and fixing following 1 or 2 Module (75 mm x 75 mm) / modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
Supply and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :
Supply and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring for connection as required.
Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type (as per CPWD Delhi Specs). Indoor Usage Rated Power - 18W Light Source - LED Installation Type - Surface Mount Voltage - 240 Volts Light Colour - Cool White
Supplying, installation, Testing & Commissioning of Panel light 2x2 Panel Lighter (as per CPWD Specs). Indoor Usage Rated Power - 36W Light Source - LED Installation Type - Recess Mount Voltage - 240 Volts Light Colour - Cool White
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten lightSurface mounted Batten Tube light. (as per CPWD Specs). Indoor Usage Rated Power - 40W Light Source - LED Installation Type - Surface Mount Voltage - 240 Volts Light Colour - Cool White
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying, Installation, Testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.)
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 3.5 core 185 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 3.5 core 70 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 3.5 core 35 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 4 core 16 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 4 core 10 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 4 core 6 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 3 core 10 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade Heavy Duty XLPE with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated with standard conductor 3 core 6 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Supplying & Laying or fixing through pipe or cable Tray of following 1100 volt grade PVC insulated Copper Flexible conductor with standard conductor 1 core 25 sq.mm nominal cross section in service connections. Material like joining material, catenary, GI wire,gland,fixing accessories, etc are included in the scope of work. NOTE : Actual quantity to be measured by contractor before supply to avoid wastage in cut piece.
Product or component type On-Line Uninterruptible power supply (UPS) Main Input AC 3 phases Other Input Voltage 380 V - 415V Input Power Frequency 50~60 Hz sync to mains Maximum input short > 0.99 circuit withstand Icc=10 kA Output voltage AC 3 phases Other Output Voltage 380 V - 415V Output Power Frequency 50~60 Hz sync to mains Rated power in (Watt.) 20 kW Rated power in (VA) 20 kVA Harmonic distortion < 3% linear load Output overload operation Minimum 10 minutes at 125% Bypass type Built-in maintenance bypass Switch Protection Circuit breaker ( Input, Output and Battery) Product certifications CE , EAC , RCM IP degree of protection IP20 Monitoring Visible and Audible Alarm ,SNMP card with Ethernet Redundancy UPS Parallel Card Warranty 1 Year Comprehensive on-site Warranty from OEM Make Schneider/Vertiv/GE Battery Specifications Battery Qty. Minimum 32NOS Battery Type SMF 12V Battery capacity (Ah) 100 Ah Nominal battery block ±192 voltage (VDC) Maximum charging power (W) 2000 W Ripple current < 5% C10 Accessories: Battery rack and connecting cable should included Warranty 2 Year Comprehensive on-site Warranty from OEM Make: Exide/Amaron Installation: All 3nos UPS should be connected with each other forming redundancy and load sharing. Any necessary equipment/item required should be included.
Supplying and fixing following RJ-45 face plate( computer Jack) modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
Supply and Installation, testing & commisioning of 20 pair Telephone Tag Block of following sizes with all assories complete in all respect.
Supplying and fixing following RJ-45 face plate( computer Jack) modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
Supply & Installation of Waterless and maintenance free Earthing (grounding) electrode of following size Dia MS / Cu /GI bonded MS conductor and Pre cast or in-site cast in high purity electrically conductive granular (Marconite), having ultra low resistivity of 0.001 Ohm - m. ( Provide the resistivity certificate for the same) Electrode made of electrically conductive granular mixed with cement to pre castor backfill the voids surrounding the metal conductor in augured bore hole of 150 mm dia x 3000 mm depth, resulting in increase of effective surface area of the earth electrode and in case of high soil resistivity agrid of multiple electrodes to be installed to lower the desiredearth resistance value , permanently with no further maintenance or periodic watering or recharge during it’s life of over 50 years in all type of soil including dry or rocky soils. Earth enhancing material should not leach into the adjacent soil or underground water channels and it’spH should be in neutral range. Electrode of dia 70mm x 3000mm with 16mm CC/GI conductor (Panels, UPS panels & lifts)
Mirror Lighting fixture Indoor Usage Rated Power - 10 W Light Source - LED Installation Type - Surface/ suspended Mount Voltage - 240 Volts Light Colour - Cool White Power back-up - 2 Hrs
Bulk Head Lighting fixture Indoor & Oudoor Usage Rated Power - 10 W Light Source - LED Installation Type - Surface/ suspended Mount Voltage - 240 Volts Light Colour - Cool White Power back-up - 2 Hrs
Supplying, Installation, Testing & Commissioning of LED Outdoor type Secutity light. Indoor Usage Rated Power - 35W Light Source - LED Voltage - 240 Volts Light Colour - Cool White
300mm sweep PVC body wall Fan
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
1.NIT.pdf
TENDER_DOCUMENT • 0.50 MB
2.UndertakingFormat.pdf
TENDER_DOCUMENT • 0.44 MB
4.PQCriteria.pdf
TENDER_DOCUMENT • 0.24 MB
5.PriceBid.pdf
TENDER_DOCUMENT • 0.38 MB
6.PQCriteria.xlsm
TENDER_DOCUMENT • 0.04 MB
7.PriceBid1.xlsm
TENDER_DOCUMENT • 0.05 MB
3.TandC.pdf
TENDER_DOCUMENT • 2.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .