Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC | ₹43.1 L Quoted ₹45.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹48.8 L+₹3.8 L (8.44%)Rejected-Finance | ₹48.8 L+₹3.8 L (8.44%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹49.2 L+₹4.2 L (9.34%)Rejected-Finance 79 O P ROAD NAYABASTI P O P S BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹49.2 L+₹4.2 L (9.34%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹49.5 L+₹4.5 L (10.1%)Rejected-Finance | ₹49.5 L+₹4.5 L (10.1%) | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹50.1 L+₹5.1 L (11.4%)Rejected-Finance | ₹50.1 L+₹5.1 L (11.4%) | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Aug 2022, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
REPAIR/MAINTENANC AND REWINDING OF CEILING FANS, EXHAUST FANS, REPAIR TO SOLAR/ ELECTRIC WATER STORAGE HEATERS, REPLACEMENT OF FITTINGS/ FIXTURES INCLUDING MISC ELECTRICAL WORK AT KANCHRAPARA UNDER GE BARRACKPORE
2022_MES_536952_1
8661/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹90,000
Yes
26 Aug 2022
9 Jul 2022
9 Aug 2022
9 Jul 2022
6 Aug 2022
23 Jul 2022
Amount
S&F of LED luminaire 600 mm x 600 mm, 40 watts, 220 Volts, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size compete including taking dwon old unserviceable light fitting complete all as specified and directed.
S&F of vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 including taking out old unserviceable DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed. ( Note- MCCB 3 pole 63 amps as main incomer will be measured and paid separately)
S&F in repairs of MCCB 3 pole , 415V fixed type of capacity 63 Amps, 16 KA, housed with Vertical load line DB and connecting under ground cable as a main incomer to he building complete all as specified and directed .
S&F of sheet metal enclosures for TPN DB's with double door for incorporating MCBs, IP-43 , TPN 4 way with 200 amps rated busbar, 415 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and directed .
S&F of sheet metal enclosures for SPN DB's with double door for incorporating MCBs, IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and directed .
S&F of sheet metal enclosures for SPN DB's with double door for incorporating MCBs,IP-43 , 12 way with 200 amps rated busbar, 240 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed .
S&F in repairs of MCB SPN 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing all as specified and as directed
S&F in repairs of MCB SP, 40 Amps, B Curve 240 volts, 50 Hz, including making necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and directed .
S&F in repairs of MCB SP, 6 to 32 Amps, B Curve 240 volts, 50 Hz, including making necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and directed .
S&F in repairs of MCB SPN 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and directed.
S&F in repairs of MCB TPN 63 Amps,415 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and directed .
M&L for earthing with glavanised steel eart plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old one earthing complete all as specified and directed. (Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
S&F in repairs of sheet metal enclosures with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 Volts complete all as specified and directed.
M&Lin repairs for LED Bldg Security light Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable brackets complete all as specified and directed.
S&F of exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper winding of sweep 225/250 mm complete including taking down old unserviceable and deposited to MES store yard complete all as specified and directed.
S&F of exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper winding of sweep 300 mm complete including taking down old unserviceable and deposited to MES store yard complete all as specified and directed.
S&F of exhaust fan , steel body, four blade, AC, single phase, 230 Volts, of size 450 MM sweep with blades and frame louvers complete including taking down old unserviceable and deposited to MES store yard complete all as specified and directed.
M&L for disconnecting electric supply, taking down fan, ceiling cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan any size from existing position and bringing to AGE E/M store yard for cleaning all dusts, oiling, greasing complete all as specified and directed .
M&L in repairs for 40 mm bore GI pipe (Light grade) fixed with wall with maximum span of 4.0 meters suitable for hanging of ceiling fan of any sweep including necessary cutting hole in brick/stone wall and making good the same with PCC 1:2:4 type C1 as required at complete all as specified and directed. (Note- Rate quoted deemed to be included for GI pipe 40 mm bore fixed on wall for hanging ceiling fan includes making holes with PCC filling by the Contractor)
S&F in repairs of stainless steel 450mm long and 15 mm bore flexi connection pipe for both hot and cold water with stainless steel braided suitable for storage water geyser complete all as specified and directed. (Make: Havells /Bajaj/Crompton Greaves/Racold or equivalent make as per Appx 'A' as mentioned in PS here-in-after)
Taking down and serviceing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush gun metal ball bearing capacitor split and reassembling the fan complete including testing after assembling and connecting to electric system complete all as specified and as directed by Engr-in-Charge.
Ditto- all as per item No 22.00 here in before but for exhaust fan of 300 to 450 mm sweep complete all as specified and directed. (Note for Item No. 22.00 & 23.00 :- Rates of bearing, capacitor, blades & painting will be paid seperatelyunder relevant items)
Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase complete at site for rewinding and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etc including testing after assembling and connecting to electric system complete all as specified and directed. (Note for Item No. 24.00 to 26.00: Rates of winding and replacement of any unserviceable parts mentioned above required to make the fan in serviceable condition are include in the quoted rate. )
Ditto-all as per item No 24.00 above but for exhaust fan 300mm sweep complete all as specified and directed.
Ditto-all as per item No 24.00 above but for exhaust fan 450/600 mm sweep complete all as specified and directed.
S&F in repairs of capacitor 2.5 mfd + 5%, 220/230 volts AC, 50 c/s complete all as specified and directed.
S&F in repairs of capacitor 4 mfd + 5%, 400/440 volts AC, 50 c/s complete all as specified and directed.
S&F of electric cable PVC insulated with copper conductor (flexible cable) round sheathed 1100 volts confirming to IS-694 of size-0.50 Sqmm twin core for connecting fan to electric system, complete all as specified and directed.
Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and directed.
Taking down and Spray painting to AC ceiling fan 1200/1400mm sweep any make complete to motor assy, down rods, blades with ISI marked with white/brown synthetic enamel paint (1st grade quality) after preparation of surface including filling cavities with filler, writing of MES No complete and refixing the same in existing location after painting complete all as specified and directed .
Ditto- all as per item No 31.00 here-in-before but for exhaust fan 300mm complete all as specified and directed .
Ditto- all as per item No 31.00 here-in-before but for exhaust fan 450/600mm complete all as specified and directed .
S&F in repairs of Canopies for AC ceiling fan of size 1200/1400mm sweep for any make of fan complete all as specified and directed .
S&F in repairs of down rods for ceiling fan 1200/1400mm sweep of size 600mm long duly painted with white synthetic enamel paint complete all as specified and directed
S&F in repairs of down rods for ceiling fan 1200/1400mm sweep of size 450mm long duly painted with white synthetic enamel paint complete all as specified and directed.
S&F in repairs of hanging clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as specified and directed
S&F in repairs of step type elctronic fan regulator in replacement Modular type (1 module), single phase 220 V, complete all as specified and directed
S&F in repairs of stepped type (0-4 step) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, testing complete all as specified and directed.
S&F as in repairs of exhaust fan louver of size 300/350 mm sweep made out of MS sheet heavy duty of 22 gauge complete includng making good the disturbed surface of wall both inner and outer side and match with the existing complete all as specified and directed. {NOTE- (i) Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinary. (ii) Height of Bldg upto 2nd storied}
S&F in repairs of exhaust fan louver of size 300/350 mm sweep made out of MS sheet heavy duty of 22 gauge complete includng making good the disturbed surface of wall both inner and outer side and match with the existing complete all as specified and directed. {NOTE- (i)Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinary. (ii) Height of Bldg from 3rd storied to 4th storied}
S&F in repairs of exhaust fan louver of size 450 mm sweep made out of MS sheet heavy duty of 22 gauge complete includng making good the disturbed surface of wall both inner and outer side and match with the existing complete all as specified and directed. {NOTE-(i) Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinary. (ii) Height of Bldg upto 2nd storied }
M&L in repairs for fan blade (set of 03) suitable for 1200 mm sweep complete all as specified and directed .
S&F in repairs of Ball bearing suitable size of ceiling fan any type and size complete all as specified and directed .
S&F in repairs of Ball bearing suitable size of Exhaust fan any type and size complete all as specified and directed .
Taking down carefully storage type water heater of 25/35 litres capacity (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes, stop valve, non return valves etc leakage arresting of inner copper/steel tank by weilding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washetrs etc refixing the same in position by replacing mounting bolts and nuts reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning complete all as specified and directed . (Note : Non return valve ,stop valve, bib tap/ PVC connection /Copper connections cable , glass wool , element, thermostat , storage tank, geyser assembly , indicator etc shall be measured separately.)
S&F of heating element 1.5/2.0 Kilo Watt Capacity of storage type water heaters of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements complete all as specified and directed .
S&F of thermostat suitable for 25/35/50 litre capacity storage type water heater including removal of old unserviceable ones complete all as specified and directed .
S&F of non return valve (gun metal) of size 15mm including taking down old unserviceable one complete all as specified and directed .
S&F in repairs of Geyser SS assembly for housing Heating element, 6/8/9 Holes type for 50/35/25 ltr for storage type Geyser complete all as specified and directed.
S&F in repairs of Geyser Copper tank for 35/25 ltr for storage type Geyser with MS collar, complete all as specified and directed.
S&F in repairs of glass wool for 50/35/25 ltr storage type Geyser complete all as specified and directed.
M&L in repairs for polycarbonate Plug top 15 Amps, 3 pin 240 Volts complete all as specified and directed.
S&F in repairs of Metal clud DP Plug Assembly AC, 220 V, 50Hz, suitable for MCB of capacity 20A, with 2 Pin and one earth pin complete all as specified and directed.
M&L for indicator lamp suitable for 25/35/50 Ltrs geysers as per existing sample in green and red colour including taking down old unserviceable one complete all as specified and directed .
S&F of 15 mm GI tubing medium grade with all fitting and fixed complete to walls and ceiling or laid in floors of size including all accessories such as tee,bend,elbow,and union etc taking down the existingunserviceable pipes and connections including making good to disturbed surface of wall and match with existing one complete all as specified and directed .
S&F of 20 mm GI tubing medium grade with all fitting and fixed complete to walls and ceiling or laid in floors of size including all accessories such as tee,bend,elbow,and union etc taking down existing unserviceable pipes and connections including making good to disturbed surface of wall and match with the existing one complete all as specified and directed .
S&F of 25 mm GI tubing medium grade with all fitting and fixed complete to walls and ceiling or laid in floors of size including all accessories such as tee,bend,elbow,and union etc taking down existing unserviceable pipes and connections including making good to disturbed surface of wall and match with the existing one complete all as specified and directed .
S&F in repairs of stop valve cock male /Female end classic handle type, chromium plated ISI marked screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipes of dia 15 mm complete all as specified and directed.
S&F in repairs of switch flush type single pole one way 15 amps, complete all as specified and directed.
S&F in repairs of Socket out let 2 in one , 3 pin 5 and 15 Amps flush type complete all as specified and directed.
M&L for single phase exhaust fan motor of 450 mm sweep having 1450 RPM speed, 320 watts copper wound, AC, 230 Volts, 50 Hz, ISI marked complete with all standard accessories including taking down old unserviceable motor complete all as specified and directed.
M&L for single phase exhaust fan motor of 300 mm sweep having 1400 RPM speed, 135 watts copper wound, AC, 230 Volts, 50 HZ, ISI marked complete with all standard accessories including taking down old unserviceable motor complete all as specified and directed.
M&L for exhaust fan blade ( four blades) having 3mm thick suitable for 300 MM exhaust fan or as per site requirement complete including takaing out/unscrewing old borken unserviceable blade complete all as specified and directed.
M&L for exhaust fan blade ( four blades) having 3mm thick suitable for 450 MM exhaust fan or as per site requirement complete including takaing out/unscrewing old borken unserviceable blade all as specified and directed.
Taking out old unserviceable broken solar water heater flate plate collector of 100 Litre per day capacity from existing system installed at roof top ( Approx 25 Mtr from normal ground level) by unscrewing complete nuts, bolts and screws and removal of other fitments/accessories like inlet and outlet water supply pipe lines, valves etc complete all as specified and directed. (NOTE- Job will be carried out on roof top and existing system installed at a height of 25 meter above the normal ground level, necessary requirement of T&P for execution of the work is deemed to be included in unit rate quoted).
Supply, fixing, commissioning and testing of stainless steel flate plate collector for solar water heater of capacity 100 litres,(Total system capacity 200/300 ltrs) 250 Kpa, roof mounted complete with all connected accessories and connection of water supply pipe line for input and output supply and suitable for existing system complete all as specified and directed. Make of existing Solar water heater - EMMVEE SOLAR SYSTEM PVT LTD (NOTE- Job will be carried out on roof top and existing system installed at a height of 25 meter above the normal ground level, necessary requirement of T&P for execution of the work is deemed to be included in unit rate quoted).
Taking down/dismantling carefully exising solar water heater tank of capacity 300 Litres by unscrewing all fitments and water supply pipe lines and removal of the tank from the system complete including any minor work required at site complete all as specified and directed. (NOTE- Job will be carried out on roof top and existing system installed at a height of 25 meter above the normal ground level, necessary requirement of T&P for execution of the work is deemed to be included in unit rate quoted).
Supply, fixing, commissioning and testing of stainless steel solar water heater Tank of capacity 300 litres,(Total system capacity 300 ltrs), roof mounted complete with water supply connection and fixing of all connected accessories complete all as specified and directed. (Make of existing Solar water heater - EMMVEE SOLAR SYSTEM PVT LTD ) (NOTE- Job will be carried out on roof top and existing system installed at a height of 25 meter above the normal ground level, necessary requirement of T&P for execution of the work is deemed to be included in unit rate quoted).
Taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 2.5 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable wiring complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable wiring complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable wiring complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable wiring complete all as specified and directed .
M&L for sub main wiring complete with 4 runs of 16 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including two runs of 16 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable wiring complete all as specified and directed .
M&L for sub main wiring complete with 4 runs of 25 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including four runs of 25 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable wiring complete all as specified and directed .
M&L for sub main wiring complete with 4 runs of 35 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including four runs of 35 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable wiring complete all as specified and directed . (Note for item No.71.00 to 77.00 : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.
Supply, installing, testing and commissioning factory made and tested Wall Mounting LT indoor , Flat top roof, cubical box, hinged comprtments with locking arrangement, front side openable & operatable type, (SIZE-800MMX800MMX400MM), suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars of 100 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class (IP-43) and made of 2.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade. The scope of work also comprising of the following including taking down completely old unserviceable switch main fuse unit with MCCB of 63 amps rating any type by disconnection all electrical connections, :- BUS BAR CHAMBER:- (a) 100 Amp TPN, Alu. conductor, Supported on insulated plate form interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) RYB Phase indicating light LED type- 01 Set. INCOMING:- (i) Change over switch 63 Amps, 4 pole - 01 No (ii) MCCB 4 pole ,415 V, of rating 63 Amp 36 KA- 1 No., OUTGOING:- (i) MCB SPN 40 Amps, 10 KA- 03 No. (iii) MCB SP 20 amps, 10 KA - 03 Nos , NOTE : (i) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible. (ii) The contractor shall submit drawings (general & circuit lay out drawings). Drawing shall be approved by GE after factory inspection by GE or Rep of GE before procurement.
INDUSTRIAL CONSTRUCTION
ALOKE ENGINEERING AND COMPANY
M/S PAUL CONSTRUCTION
M/S KARTICK CHANDRA CHAKRABORTY
M/S H.P Singha
M/s S K SHARMA
CHATTERJEE ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .