Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC 33 A DURGA NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹23.8 L+₹2.1 L (9.51%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹24.7 L+₹3.0 L (13.7%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹24.8 L+₹3.0 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹26.0 L+₹4.2 L (19.5%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
21 Jan 2023, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-61/2022-23 SPECIAL REPAIR TO BUILDING NO P-357 AND P-359 TECHNICAL SHEDS IN BANA SINGH LINE AND PROVISION OF DEFICIENT 96 NOS CEILING FAN, 96 NOS EXHAUST FAN FOR JCOS/OR MD ACCN AT CW LINE
2022_MES_570864_1
GE(N)Amb-61/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) AMBALA CANTT
As per tender documents
9 documents required · 9 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹77,000
Yes
2 Mar 2023
23 Dec 2022
23 Jan 2023
23 Dec 2022
21 Jan 2023
7 Jan 2023
23 Dec 2022 - 7 Jan 2023
Amount
Schedule 'A' Part-I (B/R itmes) Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and as directed by the Engineer-in-Charge.
M & L forming jambs, etc. to openings, including cutting, toothing and properly bonding into old work in cement mortar in 1:6, also facing, jointing and pointing to match existing complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
Demolition of reinforced cement concrete in (other then ground floor) roofs , beams staircase , landing , chajja and similar suspended works reinforcement cut as required to facilitate demolition complete all as specified and as directed by the Engr-in-charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks using old servicable bricks including cleaning of old bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC M-25 (design mix) using 20mm graded crushed stone aggregates as in beams, cantilevers, bressummers, lintles over 1.5mtr span complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 5mm dia and over up to and including 10mm dia in stirrups, spacers etc, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on any faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed by the Engineer-in-Charge.
Material and labour rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying two coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete wall and applying two coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
Taking down rolling shutters having area exceeding 15 Sqm each of any size/type incl taking down complete accessories like shaft, top cover, guide channel etc complete all as specified and as directed by the Engineer-in-Charge.
Taking down mild steel door shutters having area exceeding 8 Sqm each of any size/type incl taking down complete accessories complete all as specified and as directed by the Engineer-in-Charge.
Taking down old tar felt including plaster from roof including cleaning of old concrete roof by roughening, picking, sweeping, clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and as directed by the Engineer-in-Charge
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shell be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M & L applying a coat of solar reflective aluminium paint @ 0.11 kg per sqm on APP membrane surfaces complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' Part-II (E/M itmes) Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only and making good the disturbed surfaces with existing specifications including finishing to match with existing b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling fans, AC, single phase, 230 V, 50 Hz, copper wounded of 1200 mm sweep having service value more than or equal to 6 with BLDC technology , max power input up to 35 watt, copper wire induction motor with 5 star BEE ratings, (suitable for operating on existing fan ragulator) complete along with canopy cover, down rod, 'U' clamp, 3 core PVC flexible cable 1sqmm for making connection of fan and hanging the fan in clamp, connecting with electrical connection all as specified and as directed by Engr-in-charge. Note ; - MES No shall be written by the contractor with permanent marker over ceiling fan of specified size and colour and quoted rate shall be deemed to be included of this element.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
S&F electronic Fan regulator modular 100 watt, one module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of heavy duty exhaust fan 300mm sweep with corrosion resistant metallic body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, metallic base frame with rubber mountings for silent operation, maximum watt input not more than 55 watt, 1420 RPM, metal blades and shutter type louvers self-openable/ closeble for protecting the entrance of birds as per IS :2132-1967 and testing complete all as specified and as directed by Engineer-in-Charge.
Material and labour cutting of existing walls in circular/square shape for making opening suitable for fixing 300 mm sweep exhaust fan and 15 mm thick cement plaster on any faces of brick wall in cement mortar 1:4, finished even and fair without using extra cement and applying two coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M/s B.S.Jain
KULWANT SINGH
V K Constructive Builders
Swami Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .