Executive Engineer
D W and S Mechanical Division Gumla
Supply Installation Testing and Commissioning of centrifugal pump set having dishcharge 65 m3hr and head 90 meter and other electro mechanical allied works at Clear Water Pumping Plant for kuru Rural Water Supply Scheme
2026_DWSD_119810_1
E-QUOTATION - 13/2026-27 1st Call
Open Tender
Pumps/Motors
Empanelment
90 days
GUMLA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
12 Oct 2026
12 Oct 2026
21 Oct 2026
12 Oct 2026
17 Oct 2026
12 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation and commissioning of HSC Centrifugal pump set (make: Kirloskar / WPIL/ Mather & Platt) as per IS:5120, capable for discharging 65M3/Hrs against a head of 90 M, consisting of stainless steel impellers, stainless steel pump shaft, etc. with all accessories coupled with energy efficient (IE3) TEFC squirrel cage induction motor having 15% more BHP than that of pump, operating on 1400-1500 rpm, 415V, 3 PH, 50 HZ [make: Kirloskar /ABB/CGL/Marathon] all complete with pressure gauge, required size of sluice valve and non- return valve standard fitting, strainers, reducer, foot valve,common header, nuts & bolts, packings, fitting & fixing, labour & technician etc. including transportation, loading & unloading charge etc. all complete job as per site requirement and direction of E/I. | 2 | Job | - | - |
| 2 | Cost towards supplying, Installation, testing & commissioning of free standing type floor mounted cubical LT motor control panel fabricated with MS sheet of suitable gauge and size duly painted with two coats of red oxide primer comprising of 200 Amp, 440V copper busbar arrangement 4 pole consisting of following accessories:
(i) 200 Amp MCCB – 1 No. (Incoming feeder)
(ii) 160 Amp MCCB – 02Nos (outgoing feeder).
(iii) 160 Amp MCCB – 01No. (As spare)
(iv) 32 Amp MCB -1 No. for lighting load and other utility load.
(v)Fully Automatic Star Delta (FASD) Starter (L&K/Havell’s/Siemen’s/Schneider/BCH make) suitable for Above pump set or more etc.- 2 Nos.
(vi) 3-phase Digital display Voltmeter & Amp Meter -2 Sets, Phase indicating light R-Y-B -3 Nos.
(vii) Copper Bus Bar- 04 Pole 200 Amp, 415V Copper strip bus bar enclosed in MS sheet along with overload relay, Dry Run Protection, Motor protection device (MPD), Proper power & control wiring inside by suitable size of copper conductor and wires etc. all complete set including transportation and fitting & mounting charges at P/Plant. | 1 | Job | - | - |
| 3 | Supply,installation,testing and commissioning of twin lobe air blower capable of delivering 600 LMP per square meter (approx. 15HP) (make: Kirloskar / WPIL/ Mather & Platt or other isi reputed) of free air of filter area at 0.4 kg/sqcm at the under drains,air blower shall be adopted for WTP having capacity more than 3 MLD only. coupled with suitable energy efficient (IE3) TEFC squirrel cage induction motor operating on 1400-1500 rpm, 415V, 3 PH, 50 HZ [make: Kirloskar /ABB/CGL/Marathon] all complete | 2 | Job | - | - |
| 4 | Cost towards supply and fitting 15 H.P air break star delta starter type MK-1 (for air blower) Make- L&T /Havell’s/ Siemens etc. (JSOR 149 M 1065 ) | 2 | Each | - | - |
| 5 | Dismantling of old Foundation and removing the residuals out of the pumping plant and making of new PCC foundation 4.5’x3’x2.5’ size and MS joint 4’’x6” -02 Nos with supplying all mortar materials and foundation bolts 06 Nos with all labour tools and tackles loading unloading with alignment leveling and jointing as per P.W.D specification (1:2:4) | 4 | Job | - | - |
| 6 | Cost of supply & laying, commissioning of 3 core 25 mm² copper conductor cable 1.1 KV grade PVC insulated and PVC sheathed unarmored cable from panel to starter to motor (for air blower) with lugs socketing. Make- Polycab / Havell’s /KEI, ISI marked. | 40 | Mtrs | - | - |
| 7 | Supplying, installation, testing and commissioning of 0.5HP suitable 3 phase, 1400 RPM, 50 Hz TEFC sq. cage induction motor Make-Kirloskar/CGL/ ABB/Jyoti/Havells mounted on inline Helical Gear Head (IBC 128: 47.6: 200-19) system suitable for mixing alum/lime in chemical mixture tank with all necessary arrangements. Complete set. | 2 | Set | - | - |
| 8 | Supplying, installation, testing and commissioning of 1 HP suitable 3 phase, 1400 RPM, 50 Hz TEFC sq. cage induction motor Make-Kirloskar/CGL/ ABB/Jyoti/Havells mounted on M.S. channel fabricated base plate coupled with Gear-pinion system (Gear ratio 50:1, RPM 1500,1.47KW) used in flocculator With all necessary arrangements. Complete set. | 1 | Set | - | - |
| 9 | Cost towards s/f of DOL starter suitable for operating of 01 HP single phase, 1415 RPM, 50 Hz, 1.5 kW, Duty S1, Effn-80%, Sq. cage induction motor having relay range 13.2-20 Amp., working on 215 Volt,50 Hz. with relay contact, On-off Push buttons. Make-Havells/C&S/L&T make. (01 H.P. DOL starter) | 2 | Sets | - | - |
| 10 | Cost towards s/f of DOL starter suitable for operating of 02 HP single phase, 1415 RPM, 50 Hz, 1.5 kW, Duty S1, Effn-80%, Sq. cage induction motor having relay range 13.2-20 Amp., working on 215 Volt,50 Hz. with relay contact, On-off Push buttons. Make-Havells/C&S/L&T make. (2 H.P. DOL starter) | 1 | Set | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
T.pdf
Tender Documents • 0.25 MB
BOQ_162113.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .