Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.5 LAccepted-AOC 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | 2₹28.6 L+₹40,575 (1.44%)Rejected-Finance DOOR NO 58 18 29 NARASIMHA NAGAR BUTCHIRAJU PALEM NEAR RAMAKRISHNA PUBLIC SCHOOL GOPALAPATNAM RURAL VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹29.0 L+₹80,681 (2.86%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹30.5 L+₹2.4 L (8.44%)Rejected-Finance MIG 330 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | 4 | Rejected-Finance Not being the lowest bidder | |
| 5 | 5₹32.4 L+₹4.2 L (15.0%)Rejected-Finance DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 5 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Sept 2024, 6:00 pmClosed
Garrison Engineer Utility-II Vizag
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
REPAIR REPLACEMENT OF WATER DISTRIBUTION LINE INCLUDING SLUICE VALVE NRV ARV AND ATTENDING EMERGENCY BREAKDOWN TO WATER DISTRIBUTION NETWORK FROM MINDI TO INS EKSILA AND INS EKSILA TO INHS KALYANI AND NSB AND STPs AT DOLPHIN HILL UNDER GE UTILITY-II
2024_MES_663834_1
8990/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VISAKHAPATNAM
As per NIT
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Utility-II
₹80,000
Yes
25 Nov 2024
4 Jul 2024
6 Sept 2024
4 Jul 2024
5 Sept 2024
20 Jul 2024
4 Jul 2024 - 11 Jul 2024
Amount
M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedimentation/clear water sumps of capacity Semi- UG sump reservoir 3.0 Lakh gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: rays Cleantech/ Inus watertech/ Satya enterprise. Location: PH NO-4 seven stages are as under plants:- (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c). Third storage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified branded halogen compound. (e). Fifth stage is cleaning the floor of water tank by industrial vacuum cleaner. (f) . Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69, complete all as specified. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY AS APPROVED BY GE.
All as per Sl. item No. 1.0 above but for 2.50 lakh gallons capacity
All as per Sl. item No. 1.0above but for 1.00 lakh gallons capacity
All as per Sl. item No. 1.0 above but for 30000 gallons capacity
All as per Sl. item No. 1.0 above but for 10000 gallons capacity
All as per Sl. item No. 1.0 above but for 5,000 gallons capacity .
All as per Sl. item No. 1.0 above but for 25,000 gallons capacity.
All as per Sl. item No. 1.0 above but OH water tank of 2.00 lakh Ltr capacity
All as per Sl. item No. 1.0 above but HDPE water tank of 10,000 Ltr capacity
NOTEs for item no. 1 to 9 :- (i) Agency shall submit government laboratory test certificate of TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXII-60/NB-69 and also provide certificate confirming the complete sterilization of water tanks mentioning the name of station and date of cleaning. (ii) It should be mandatory that all the cleaning & sterilization staffs shall be covered under accidental insurance coverage. (iii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scals and the same shall be reconnected after cleaning the OHT and the quoted rate shall deemed to include for the revision . (iv) sterilization team shall comprised of at least 30% members who are minimum 03 months certificate holder in water tanks sterilization. (v) The contractor shall be responsible for rectification of complaints occurred during cleaning the tank. Complete leakage related / breaking of valves etc during work shall deemed to be inclusive in quoted rate.
Material and labour for cleaning of RCC equilisation tank of approx size 5.5 m x 8.0 m x 5.5 m of STP at D sector by bailing out the accumulated raw water at the bottom and removing the complete silt/sludge/dirt from the tank and depositing away exc 1.5 KM and n.exc 5.0 KM from site as directed, scrapping the tank inner walls and bottom with wire brush and cleaning the tank by applying anti- bacterial spray. complete all as directed. Note: (a) The rate quoted deemed to be inclusive of T&P and transportation required for disposal of sludge/dirt away from the site. (b) The cleaning of tank shall be performed every month as per manufacturers recommendations.for following location.
All as per Srl item No 12 above but for RCC equilisation tank of approx size 5.5 m x 6.0 m x 5.74 m at 'L' Sector STP.
All as per Srl item No 12 above but for RCC equilisation tank of approx size 5.5 m x 6.0 m x 5.74 m at 'M' Sector STP
All as per Srl item No.12 above but STP at 'E' sector of approx size 12.7 metre dia and 2.0 metre height.
All as per Srl item No.12 above but for treated water tank of RCC construction and of approx size 8x6x3.5 m
All as per Srl item No.12 above but RCC treated water tank of approx size 5x6x3.5 metre at 'L' Sector STP
All as per Srl item No.12 above but RCC treated water tank of approx size 5x6x3.5 metre at 'M' Sector STP
All as per Srl item No.12 above but RCC treated water tank of approx size 12.7 metre dia and 2.0 metre height at 'E' Sector STP
All as per Srl item No 12 above but RCC treated water over head tank of 50000 Lit Capacity at E Sector Dolphin Hill.
All as per Srl item No 12 above but RCC treated water over head tank of 18000 Lit Capacity at E Sector Dolphin Hill.
All as per Srl item No 12 above but RCC treated water Sump of 10000 gallon Capacity at D Sector Dolphin Hill.
M & L for cleaning of sludge drying bed filter media complete of size 1/8 to 1/16, 1/16 to 1/32 inch sizes complete in layers of sludge drying beds of size 4 x 2.50 x 1.4 m, scraping the internal surfaces of sludge drying beds with wire brush,and cleaning with bleaching powder slurry, cleaning with fresh water including applying one coat of white wash on external surface of sludge drying bed and re-filling up with new filter media in layers all as per manufacturers recommendations or with existing filter media after cleaning including testing and commissioning etc., complete all as specified and as directed. Note: New filter media shall be measured and paid separately under relevant item of BOQ.
Supply only aggregate filter media for STP sludge drying bed (as per existing) complete of size 1/8 to 1/16, 1/16 to 1/32 inch size complete in layers as per existing, complete all as specified and as directed.
Supplying only alam (white colour granual) for cleaning of treated water, complete all as specified and as directed.
M & L for Air diffusers of SSI 's AFT -N3750 (91 X750)mm -E fine bubble EPDM membrane tube diffuser c/w saddles for reactor -1, complete all as specified and as directed.
M & L for Air diffusers of SSI 's AFT -N3750 (91 X750)mm -E fine bubble EPDM membrane tube diffuser c/w saddles for reactor -2, complete all as specified and as directed.
Supply and installation of UPVC piping along with fitting for diffuser with NRV and valves for reactor-1, complete all as specified and as directed.
Supply and installation of UPVC piping along with fitting for diffuser with NRV and valves for reactor 2, complete all as specified and as directed.
Replacement of FMR media for reactor -1, complete all as specified and as directed.
Replacement of FMR media for reactor -2 , complete all as specified and as directed.
Replacement of Tube settler frame and media, complete all as specified and as directed.
M & L for sludge removal, Acid cleaning and Epoxy painting of tube settler tank, complete all as specified and as directed.
M &L sludge removal and acid cleaning of Raw sewage tank, complete all as specified and as directed.
M &L sludge removal and acid cleaning of sludge sump, complete all as specified and as directed.
M &L sludge removal and acid cleaning of Filter Feed Tank, complete all as specified and as directed.
M &L sludge removal and acid cleaning of reactor -1, complete all as specified and as directed.
M &L sludge removal and acid cleaning of reactor -2, complete all as specified and as directed.
M & L for repair, acid cleaning , internal external Epoxy painting of Active carbon Filter, complete all as specified and as directed.
Supply & lay in repair MS ERW pipe heavy grade of following sizes for inserting in position, making leak proof joints including necessary bends and testing and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm Dia
M&L for disconnecting and removing the existing defective Mono block / centrifugal pump/Submercible set motor of any make of following capacity from the installed position by putting dummy plate to suction and delivery removing the burnt out winding and re-winding the same with super enamelled copper wire of same gauge and same No of turns of existing make insulating winding with existing class of insulation varnishing baking up including replacement of base foundation nuts, bolts and re-installation of pump, testing to satisfactory performance complete all as specified and directed. Note:- Bearings, CI gland plates, Terminal block, shaft shall be measured and paid separately under relavent items of BOQ
Up to 5 HP
Supply only ball bearings suitable for centrifugal and mono block pumps motors as existed at site, complete all as specified and directed:-
Up to 5 HP
Supply only CI gland plate high tension studs for Centrifugal / mono block pumps for the following capacity, complete all as specified and directed:-
Up to 5 HP
Supply only CI impeller suitable for centrifugal / mono block pumps for the following capacity, complete all as specified and directed:-
Up to 5 HP
Supply and fix 3 pole power contactor of existing model for AC 415 Volts, 50 Hz, 3 Phase suitable for electric motor of following capacity including removing existing unserviceable one from star delta starter complete all as specified and directed.
Up to 5 HP
Supply and replace Pump Shafts as per existing Model with necessary metal filling and machine suitable for the following capacity of pump sets:-
Up to 5 HP
Supply and replace Casing ring for Centrifugal / Monoblock pumps for the following capacity :-
Up to 5 HP
Preparation to old external surfaces of Pipes/Panels indoor/outdoor type for painting by scrapping down old rusted paint by steel brush broomming rubbing and applying one coat of synthetic enamel paint, complete all as specified and directed.
Supply and lay in replacement in floors/ on roof /on wall / trenches GI water tubing of following sizes galvanised medium grade with all fittings, complete all as specified and directed:-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply and fix gun metal gate valve of following sizes with iron wheel head screwed both ends for iron pipe including dismantling old one, complete all as specified and directed:-
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
M&L replacement of unserviceable sluice valve, spindle, and check nut by un screwing nut and bolts, gasket stuffing box and taking upper portion of sluice valve taking out u/s spindle check nut, cutting turning, polishing and preparing new SS spindle and check nut from the solid single SS piece of same length , dia of u/s spindle and check nut fixing the new spindle and check nut re assembling sluice valve replacement of u/s gasket nut and bolts and testing for the following bore sizes of sluice valve, complete all as specified and directed:-
Taking out sluice valve stuffing box and re-packing stuffing box of sluice valve including taking apart & assembling & refixing it into its original position & replacement of rubber gasket and nut & bolts for the following sizes, complete all as specified and directed:- Note:- Rubber gasket, nuts, bolts and washers shall be measured and paid separately.
80 mm dia
100 mm dia
150 mm dia
200 mm bore
Supply only rubber gasket 3 mm thick, complete all as specified and directed.
Supply only black bolt with hexagon head and nuts round neck with washer 3 mm thick, complete all as specified and directed.
Supply and fix in repair CI sluice valves of following Sizes , PN 1.6, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints, replacement of perished nuts, bolts washers and rubber gasket etc. complete all as specified and directed:-
250 mm dia
150 mm dia
100 mm dia
80 mm dia
Supply and fix in repair MOC WCB, Sluice valves , PN 1.6, Class 200 conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints, replacement of perished nuts, bolts washers and rubber gasket etc. complete all as specified and directed.
M&L for jointing flanged pipe and fittings including provn of rubber or fibre board gaskets and washers required for jointing including taking out fibre gaskets and nuts & bolts for the following sizes, complete all as specified and directed:-
80 mm Dia
100 mm dia
150mm bore
200mm bore
250mm bore
M&L cutting the road hard standing for laying of pipeline including filling& making good surface with PCC 1:3:6 C-1 Type using 20 mm graded stone aggregate & removing the to distance n.exe 50mtr, complete all as specified and directed.
M&L for stone masonry for walling of random rubble, uncaused, well bonded, built in cement mortar 1:4 for construction of thrust block for the support of water supply pipe line including demolition of existing masonry work complete all as specified and directed.
Material and labour for taking down defective foot valves from UG Sump, scraping the corroded foot valves and painting with one coat of red oxide along with black enamel paint, replacing rubber gaskets, bottom rubber with spring complete with replacement of necessary bolts, nuts, washers for following sizes complete all as specified and directed:-
150 / 200 mm dia
80 / 100 mm dia
Supply and fix in repair CI non return valve of 200mm dia size with by pass arrangement and necessary rubber gasket, nuts, bolts, and washers etc., complete all as specified and directed.
Supply and fixing in repair cast iron air release valve with two air outlets, 80 mm dia bore with isolating sluice valve and fixing up in water supply mains including necessary addition / alternation to DI pipe 150/200/250 mm dia bore with all necesary fittings complete all as specified and as directed.
M&L for construction of brick massionary and valve chamber for the following internal dimension with angle iron frame and MS sheet cover 3mm thick duly painted 2 coats of red oxide zinc chromate primer including lifting handle, locking arrangement, excavation earth work and plastering, complete all as specified and directed :-
900 mm x 900 mm x 900 mm (For 100mm & 150 mm Valve)
1200 mm x 1200 mm x 1200 mm (For 200 mm Valve)
M&L for attending break down of pipe line for the following sizes of pipes bursting/cracks with the use of Earthmoving machinery/labour and taking out old CI/DI/MS defective/misaligned water pipe line carefully after disconnection of joints to a length up to 8 mtr and create bund with excavated earth and dewatering/bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs including replacing CI specials, returning filling and removal of surplus soil/excavated material with the help of excavator/proclainer, complete all as specified and directed :- Notes:- (a) M/L for lead joints, Supply only pipes and Earth work shall be measured and paid separately. (b) The rate is deemed to include cost for tool and plant and transportation required for attending the repair work. (c) Disconnecting/dismantling/cutting the existing pipe line is included in the qouted rate (d) The breakdown shall be attended within 2 hrs of intimation round the clock and time of restoration shall be maximum of 8 hours. The additional manpower required to complete the job in quoted rate is deemed to be included.
250/200 mm dia bore
150/100 mm dia CI pipe.
Supply only DI K9 water supply pipe lines spigot and socket having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329 complete of following Sizes, complete all as specified and directed :-
250 mm dia
200 mm dia
150 mm dia
100 mm dia
Supply only DI Specials (any type radius and angle) tapers any type straight increasing decreasing or double socket and ''Y junction double branch , cross (all sockets or socket and spigot)caps and plugs upto 300 mm bore, complete all as specified and directed.
Burning out lead joint in position including removing old lead to store for the following sizes:-
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Burning out lead joint in position including removing old lead to store for the following sizes:-
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Material and labour for run lead joint for spigot and socket pipes (CI/DI) and fittings of following sizes, complete all as specified and directed:-
100 MM bore
150 mm bore.
200 mm bore.
250 mm bore.
Supply and replace submersible pump controller 3 Ph, 415 V for pump capacity upto 5 HP, complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for laying of cables / pipes etc and getting out in hard/dense soil, complete all as specified and as directed.
Returning, filling in including spreading levelling watering and well ramming in layers not exc 25 cm in any type of soil, complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and fixing in repair 60 HP soft starter with inbuilt contactor and relay, complete all as specified and as directed.
Supply and fixing in repair 270 HP soft starter with inbuilt contactor and relay, complete all as specified and as directed.
Supply, laying, testing and commissioning in repair of LT XLPE insulated,armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 x10 sqmm (laid in terenches,ducts,pole,wall etc.), complete all as specified and as directed.
All as per above Srl item No.76 here in before but of cable size 4 x 16 sqmm.
Supply & fix in repair FRP pole box 170 x 170 x 105mm consisting of 1 No 50 A 4 pole connector and 1 No 16 A MCB, taking down the old/unserviceable junction boxe, complete all as specified and as directed. Make : Hansel / SINTEX Cat No. GS-JB-1414
Supply and fix in repair timer heavy duty of 110- 230 V 50Hz with built in battery,16A capacity with backup of 100hrs weekly programmable all as specified and directed. Make : Indo Asian Cat no : TA926129 or equivalent in L&T/ Legrand / Havells
Supply and fix in repair contactor , 3 pole, 415V, 40A cap , ML2 , 2 NO+NC utilised for heavy duty, complete all as specified and as directed.
Supply & replace deterioted twin core PVC aluminum PVC sheathed and insulated twin core 4 sq mm stranded aluminum conductor wire from light fitting to loop-in loop out box along with 15mm PVC conduit fixed with saddles along the pole and taking down the perished burnt wiring, complete all as specified and as directed.
Supply and fixing against repairs LED Bollard with round top 9 W ,220V 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation cable condits for loop in and out , cable connectors complete all as specified and directed Make cat no. LBLA1-10-CDL of Crompton graves or equivalent in Bajaj / Havells
Supply and fixing of outdoor type luminaire post top luminrare (prince opera midi) of 240 v,50hz of capacity 40watt LED luminare ip 65 suitable for mounting on 60mm OD pipe on necessasry PCC works all as specified and directed Make:Cat NoLPTO-40-CDL/M of CG or equivalent in Bajaj / Havells
Labour for attending GI pipe line complaints (break downs) in trenches/ floors/ path/Wall for pipe of size 20 mm to 100 mm dia inclusive of all GI fittings like bends, sockets, unions, reducers and elbows etc., and cutting and threading of pipes as per site requirement complete all as specified and directed. Note: Earth work, Supply only GI Pipes shall be measured and paid separately.
Supply only GI tubing medium grade of Size 20 mm dia, complete all as specified and as directed.
Supply only GI tubing medium grade of Size 25 mm bore, complete all as specified and as directed.
Supply only GI tubing medium grade of Size 40 mm bore, complete all as specified and as directed.
Supply only GI tubing medium grade of Size 50 mm bore, complete all as specified and as directed.
Supply only GI tubing medium grade of Size 80 mm bore, complete all as specified and as directed.
Supply only GI tubing medium grade of Size 100 mm bore, complete all as specified and as directed.
Supply, fix in repair butterfly valves of followings sizes including cutting, welding if any complete and painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
SCHEDULE OF CREDIT Note :- Amount of Rs. 67,285.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
ROHITH INFRA (BID ID -3087428)
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3074527)
M/s.DSRK CONSTRUCTIONS (BID ID -3074548)
Prasad and Suresh Constructions (BID ID -3086416)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .