Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹11.3 L+₹44,055 (4.05%)Rejected-Finance H NO 19 6 243 1 NGO S COLONY SHIVNAGAR NORTH BIDAR 585 401 | BIDAR | BIDAR | KARNATAKA | 585401 | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AIR FORCE, SECUNDERABAD
CWE AIR FORCE SECUNDERABAD, BOWENPALLY POST, SECUNDERABAD - 500011
MAINTENANCE AND REPAIRS TO HT OVER HEAD LINES AND HT UG CABLES ALONGWITH CONNECTED WORKS UNDER GE (AF) BIDAR.
2020_MES_374779_1
85532/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) BIDAR
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE (AF) BIDAR
₹50,000
Yes
12 Dec 2020
5 Sept 2020
10 Oct 2020
5 Sept 2020
8 Oct 2020
25 Sept 2020
5 Sept 2020 - 15 Sept 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 m in depth but not exceeding 3 mtr in hard soil.
Supply and laying unreinforced pre cast concrete cable cover class HV type 1 flat size 300 x 180 x 40 mm for cable protection
Supply and spreading fine river sand in trenches for cushioning of under ground cable including gently punning all as directed by Engr-in-Charge at site Note:- punned thickness 18 cm shall be measured and paid .
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cms all as specified and directed.
Removing excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point
Relaying old serviceable unreinforced pre cast concrete cable cover obtained against item no 8 all as directed
Taking down of HT XLPE/ PVC UG cable 11000 V grade ,3 core of any size/dia up to 240 Sqmm from the trenches complete all as directed by Engineer - in charge
Relaying of old serviceable HT XLPE/ PVC UG cable 11000 V grade ,3 core of any size/dia up to 240 Sqmm from the trenches complete all as directed by Engineer - in charge of the
M & L for XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,3 core, 11000 volts, grade of the size 240 Sqmm .
All as per item no 10 here in before but of size 185 Sqmm
All as per item no 10 here in before but of size 120 Sqmm
All as per item no 10 here in before but of size 95 Sqmm
M & L for Indoor type end termination jointing kit heat shrinakable for 11KV grade UG cable 3 core Aliminium conductor of size 240 Sqmm to 300 sqmm complete along with jointing material all as specified and as directed
All as per item no 14 here in before but of size 120 to 185 Sqmm
All as per item no 14 here in before but of size 95 Sqmm
M & L for Outdoor type , end termination jointing kit,heat shrinakable for 11KV grade UG cable 3 core Aliminium conductor of size 240 Sqmm to 300 sqmm complete along with jointing material all as specified and as directed
All as per item no 17 here in before but of size 120 to185 Sqmm
All as per item no 17 here in before but of size 50 sqmm to 95 Sqmm
M & L for Outdoor type Straight through ,jointing kit,heat shrinakable for 11KV grade UG cable with 3 core Aliminium conductor of size 240 Sqmm to 400sqmm complete along with jointing material all as specified and as directed of
All as per item no 20 here in before but of size120 to 185 Sqmm
All as per item no 20 here in before but of size 50sqmm to 95 Sqmm
Disconnection & Removing the unserviceable Aluminium Over head conductor of sizes from the HT 1/2/3/4 Poles carefully along with all the jumpers and Aluminium binding wire complete all as directed
M&L for ACSR conductor of any description & sizes including cut to length, strining & binding as per site requirement complete all as specified and directed
Disconnection and removing broken/unserviceable PCC poles 11m height & supply and fix prestressed concrete pole 11 M long,class 9, 152 mm x 152 mm at top and 152mmx260mm at bottom and positioning in true vertical position complete all as specified and directed. Note : Excavation, earth work and PCC will be measured and paid separately
PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation all as specified and as directed
PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping including necessary formwork exposed surface of concrete shall be finished even and smooth without using extra cement complete all as specified and as directed
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation all as specified and as directed
Disconnection and removing the unserviceable/corroded steel obtained from cross arms,bracings etc. and Supply and erect cross arms ,bracings,supports,clamps and back plates fabricated from steel section including nuts,bolts and washers inclusive of one coat primer and two coats of painting complete all as specified and as directed.
Disconnection and removing the unserviceable GOD of capacity 400 A,11 KV, horizontal / vertical type from the Two/four pole/ six pole structure with operating mechanisum complete carefully and Supply and fix Gang Operated air-break switch 400 A , 11 KV , triple pole, mounted on post insulator along with and including 25 mm light grade GI tubing operating from operating mechanism from ground level complete all as specified and as directed.
All as per item no 30 here in above but of capacity 200 Amps
Disconnection and removing the unserviceable 11 KV Disc type insulator from HT poles and S&F Disc type insulator, porcelain, vitreous 145mm hight and 255 mm dia ball and socket type, white,brown or green single disc assembly of 11000 volts. ISI Marked along with fixing material such as GI bolt,nut and washers etc.
Disconnection and removing the unserviceable 11 KV Pin insulator from HT poles and S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts ISI Marked along with fixing material such as GI bolt,nut and washers etc.. grade complete all as specified and as directed.
Disconnection and removing the unserviceable 11 KV Lightening arrester carefully from the 2/4/6 Pole structure and Supply & fix lightining arrester suitable for 11000 Volts of discharge capacity 65 kilo Amp, 3 Phase including connecting of the same to the supply with necessary fixing materials such as nut bolt, washers etc. all as directed at site by the Engineer in Charge.
Disconnection and removing the unserviceable 11 KV Expulsion fuse single pole carefully from the 2/4/6 Pole structure and Supply & fixing Expulsion fuse single pole along with post insulators suitable for 11000 Volts, 50 A capacity including connecting of the same to the supply with necessary fixing materials such as Aluminium jumpers , Aluminium binding wire etc. all as directed at site by the Engineer in Charge.
Disconnection & Removing the unserviceable Aluminium conductor/jumper wires from the HT 4 Pole structure and M & L for New Aluminium overhead conductor jumpers sorrounded by PVC insulation sleeves with R,Y& B color code complete all as directed. Note : (1) All the jumper wires should be replaced with New jumper wires (2) Type of conductor used for jumper should be RABBIT. (3) Cost deemed to be include for all the misc work such as Nut,bolts, washers, welding etc. for satisfactory completion of job . (4) Min clearance should be maintained among the conductors as per the Electricity Regulations. (5) Zero percent Sag should be maintained for each jumper wire to avoid short circuit.
All as per item No.36 above but for 3 Pole structures
All as per item No.36 above but for 2 Pole structures
M & L for painting to HT Steel tubular poles 11 mtr height by scapping the existing painting and repainting after due preparation of surface and applying a coat of primer i.e. red oxide complete with another coat of Aluminium paint complete all as directed .
M&L for providing earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x6 mm thick buried directly in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal & common salt Crystal and connected to galvanised earth strip 25 x4 mm by means of bolts, nuts, check nuts & washers of GI and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I - 2009 including 40mm dia light grade GI pipe upto 7.5mtr long as earth conductor protection , excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test point box , 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( Note1 :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ). Note 2: Qoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.
Disconnection and removing the unserviceable earth conductor and S&F earth continuity conductor 20x3 mm copper strip buried in ground / fixed on wall / drawn in 40mm dia light grade GI pipe
Dismantling and removing the u/s earthing from the 4 Pole/3Pole/2 Pole structure all as specified and as directed
ramesh construction co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .