Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.5 L+₹83,728 (12.6%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹7.2 L
EMD Value
₹17,926
Closing Date
13 Feb 2024, 6:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer,PWD Electrical Subdivision,Chembukavu,Thrissur-20
DEPOSIT-Urgent replacement of damaged 8.5 TR AC units with two 5.5 TR ductable AC units in Peadiatric ICU at Govt Medical college hospital Thrissur-General Electrical work
2024_PWD_656273_1
ESDT(ET)167/AEE/23-24
Open Tender
Electrical Works
Item Rate
90 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,585
₹17,926
24 May 2024
8 Feb 2024
16 Feb 2024
8 Feb 2024
13 Feb 2024
8 Feb 2024
Amount
electrification
OD47590/2023-2024:SITC of 5.5 TR air-cooled Ductable split Air conditioners consisting of Hermetically Sealed High efficiency Scroll Compressor, Copper refrigerant coil, fan motor assembled in powder coated metal enclosure with HP/LP safety switch microprocessor-based control unit protection relays contactors etc, suitable for operation on R 410A gas complete Air-cooled compressor with accessories, anti vibration pad etc with one year warranty for machine and one year 4Nos free service. Make Carrier/Blue star/ Dikin/Equivalent
OD47246/2023-2024:Supply, Installation, Testing and Commissioning of Hard drawn Refrigerant Copper Piping , insulated with 9mm thick nitrile rubber tubings approved make, the price quoted shall be inclusive of proper supports. Size:15.9 mm
OD47247/2023-2024:Supply, Installation, Testing and Commissioning of Harddrawn Refrigerant Copper Piping insulated with 13 mm thick nitrile rubber tubings approved make, the price quoted shall be inclusive of proper supports. size: 22.23 mm
OD161554/2023-2024: Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting (in accordance with SMACNA standards)complete with neoprene rubber gaskets, elbows, splitter dampers, bends, transformations, vanes, , inspection doors , plenums hangers, supports, angle iron flanges , Hi Tech/ Hilti GI supports, GI full thread rods , anchor bolts ,GI nuts and bolts etc as per approved drawings and specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 22 SWG( 0.3973mmthick)
OD47300/2023-2024:"Supply, installation and testing of thermal insulation of ducts using closed cell Nitrile Rubber insulation with recommended adhesives and sealed with black adhasive tape and density of material shall be 40-60 kg/cubm. (Make : Armaflex/K-Flex/ALP)" 13mm Thick Nitrile Rubber
OD47303/2023-2024:Supply, installation and testing of acoustic lining with 10 mm thick open cell nitrile foam on the inner side of ducting including providing, fixing and finishing the same as per specifications for ducts as required density of material shall be 140-180 kg/cubm (Make : Armaflex/K-Flex/ALP)
OD47269/2023-2024:Supply and fixing of the fire retardant type canvas for inter connecting cooling unit with duct/pleanum and fixed infront area of the unit to avoid excess vibration with required accessories.
OD47254/2023-2024:Supply and filling Refrigerant R 410 A gas
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD47262/2023-2024:Supply, installation, testing and commissioning of insulated condensate drain piping out of PVC- 6g/cm2 pipes complete with hangers/supports/clamps/Clips and all ,fittings etc. and insulated with 13mm thick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-25mm dia
OD47359/2023-2024:SITC of manual damper
16.16.a:Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
OD50270/2023-2024:Supply and installation of FP enclosure for independent mounting of MCB/ RCCB/ RCBO/ isolator
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD50479/2023-2024:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 4 sqmm-16 sqmm with 12 mm wide x 1 mm thick clip
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
OD47258/2023-2024:Dismantling charges of Exsisting ductable units
cristalcool
Bidder Name
PONNU HYLINE
cristalcool
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1013324.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .