Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.0 L+₹96,215.43 (5.34%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹19.2 L+₹1.2 L (6.75%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹20.0 L+₹2.0 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹22.0 L+₹4.0 L (22.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹18.3 L
EMD Value
₹37,600
Closing Date
8 Aug 2020, 6:00 pmClosed
CWE Rajouri
Headquarters, Commander Works Engineers, PIN-900129, C/o 56 APO
PROVN OF OFFICE CUM STORAGE ACCN AND SPECIAL REPAIRS TO BLDGS NO T 29 NH OFFICE COMPLEX IN DOU AND SPECIAL REPAIRS TO BLDG NO T16 OFFICE BUILDING IN EME AT RAJOURI UNDER GE 862 EWS
2020_MES_346579_2
CWE RAJ 07 2020 21
Open Tender
Civil Works
Lump-sum
180 days
GE 862 EWS
As per NIT uploaded of CA No CWE/RAJ-07/2020-21
7 documents required · 7 mandatory
₹500
GE 862 EWS
₹37,600
Yes
28 Sept 2020
14 Jul 2020
11 Aug 2020
14 Jul 2020
8 Aug 2020
25 Jul 2020
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar mortor incl all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Stone walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and as directed.
All as per srl item No 2.00 here-in-before but except stones using old stones.
Extra over stone walling, random rubble brought upto courses, for hammer dressing to face stones and dressing of face beds and joints, with maximum depressions on face from straight edge held against the dressed surface not exc. 40 mm on lime or sand stone complete all as specified.and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and as directed.
Non-skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors, skirting etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specfied and directed.
All as per srl item No 6.00 here-in-before but on vertical surfaces such as skirting etc complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 but n exc n.exc 4 Sqm each complete all as specified and as directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each (without taking off shutters from the frames ) complete all as specified and as directed.
Taking down cement plaster on brick work or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
15 mm thick cement plaster in 1:6 on surfaces other than fair faces of brick work or stone masonry surface finished even and smooth without using extra cement complete all as specified and as directed.
15mm thick cement plaster on stone masonry surfaces or surface other than fair face of brickwork in cement mortar 1:4 complete all as specified and as directed.
20 mm thick cement plaster in 1:6 on surfaces other than fair faces of brick work or stone masonry surface finished even and smooth with out using extra cement complete all as specified and as directed.
Rendering 20 mm thick on stone masonry surfaces or surface other than fair face of brickwork in cement mortar 1:4 complete all as specified and as directed.
Applying two coat of oil bound distemper over a layer of wall putty including preparation of newly plastered surface etc complete all as specified and as directed.
Complete removal of existing treatement and applying two coat of oil bound distemper over a layer of 3 mm thick wall putty on old plastered surface etc all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings exceeding 15 cm thickness above ground level complete all as specified and as directed.
75 mm thick PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in plinth protection complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any gauge thickness, including Nainital or similar pattern roof coverings,complete all as specified and as directed.
Galvanised, corrugated mild steel sheeting as in roofs with two corrugation side lap, 0.63mm thick with 275 gm/sqm of zinc coating fixed with galvanised L-hook of cranked bolts, 8mm dia with bitumen and GI limpet washers filled with white lead complete all as specified and as directed.
Galvanised, corrugated mild steel sheeting with two corrugation side lap, 0.80mm thick with 275 gm/sqm of zinc coating as in ridges, hips, valley gutters, drip and straight flashings fixed with galvanised L-hook of cranked bolts, 8mm dia with bitumen and GI limpet washers filled with white lead complete all as specified and as directed.
Dismantling timber scantling 40 sqcm and over in section in any position as in unframed work complete all as specified and as directed.
Mild steel structural steel work conforming to Fe-410-S as in main and cross beams, hip and jack rafter; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and painted with a shop coat of zinc chromate primer before hoisting and fixing in position complete all as specified and as directed. Note: All structural steel work shall be painted with one shop coat of zinc chromate primer including preparation of surfaces
Mild steel structural steel work conforming to Fe-410-S as in roof trusses (framed), trussed purlins of beam, tee, angle, channel or flat section including distance pieces cleats etc and cutting to dead ends, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gussets plates etc also for wedging truing up and fixing complete Note: All structural steel work shall be painted with one shop coat of zinc chromate primer including preparation of surfaces
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling filling and mass complete all as specified & directed.
Damp proof course 40 mm thick. in PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) to horizontal or vertical surface complete all as specified & directed. .
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed. .
Reinforced cement concrete 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified & directed. .
Formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified.
MS TMT bars 10 mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. .
MS TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia complete all as specified & directed.
Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete all as specified.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
All as per srl item No 33.00 here-in-before but without glazing bars.
MS framed work such as grills grating etc with ends of bars shouldered and /or riveted or forged into spikes framed guard bars, barred iron doors ladders framed balusters walk way railings framework of water tank and similar work conforming to Fe 290 Gde E-165 complete all as specified.
Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and directed.
35mm thick 2nd class hard wood plain framed panelled shutter (any No.of panels ),with panels of timber flat on both sides (feather edged )or of veneered particles board medium density ,wood particle board with commercial face veneers ,supplied and fixed to chowkat
Plain cement concrete 1:3:6 type C-0 as in back filling of pressed steel door frames complete all as specified and as directed.
250 mm size mild steel sliding door bolts plate type, stove enamelled black with bright bolt not less than 12 mm dia with and incl a minimum of 6 bolts (four on bolt plate and two on staple plate complete all as specified and as directed.
Extruded aluminium alloy handles size 150 mm fabricated type anodised complete all as specified and as directed.
Aluminium anodized barrel tower bolts 150 mm long of extruded section complete all as specified and as directed.
3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane complete all as specified and as directed.
Preparation of new of previously untreated steel or iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Applying two coats of synthetic enamel paint over a coat of pink primer on new or previously untreated wood and wood based surface including preparation complete.
Plain cement concrete 1:2:4 type B-1 (20mm graded crushed stone Agg) as in coping, bed blocks etc complete all as specified and as directed.
Reinforced cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in slab, RCC chhajja shelves etc.all as specified and directed.
Form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness including cover fillet complete all as specified and directed.
4 mm thick ceiling board fixed with screws as per manufacturers instructions (Make: everest or equivallent as approved by GE), all sections shall be coated white. The frame shall comprise of main runer made from 0.33 mm thick galvanized steel sheet and size of 24X32X300mm and spread at 1200mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. hangers of GI wire 4mm dia to be fixed with approved rawl plugs, level adjusters and screws etc. The last hanger at the each end of main runner shall not be greater than 450mm from adjuscent wall, flush fitting of 1200mm long cross tee with double stitching to be interlocked between main runners at 600mm centre to form 1200X600mm modular cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, perimeter wall angle shall be of 19mmX19mmX.45mm thick galvanised steel powder coated white complete as specified and as directed.
Applying two coats of cement based paint on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified.
Preparation of old plastered / unplastered walls surfaces and applying one coat of cement base paint complete all as specified and directed by Engr-in-Charge
Anodized aluminium frame for doors, windowsd, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and directed.
Anodized aluminium window and ventilator shutters, side hung type without sash bar, aluminium sections weighing 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 nos) hinges type B-21 100 mm long (2 Nos) suitable handle (1 nos) complete all as specified and directed.
Supply and fixing sheet glass ordinary quality 4.0 mm thick type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and as directed.
Solar control film 25 micron thick reflective type sticked to glass panes as per instructions to the manufracturer complete all as specified and as directed.
Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength not less than 550 Mpa as in roof covering to wall fixed with self tapping screws as specified.
All as per srl item No 56.00 here-in-before but plain galvalume sheet as in ridge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep for foundation etc and getting out in any type of soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Removing excavated material (soil) to distance not exceeding 50m and depositing at a level not exceeding 1.5 m from the starting point complete all as specified and directed.
RCC M-25 (design mix) using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs under reamed piles and mass concrete complete all as specified and as directed.
RCC M-25 (design mix) using 20 mm graded crushed stone aggregates as in columns, pillars, piers posts and struts complete all as specified.
RCC M-25 (design mix) using 20 mm graded crushed stone aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
Use and waste of flat formwork to rough finished surface of concrete sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffits (if any) of foundation and plinth beam, and similar work, vertical or to batter complete all as specified and directed.
Use and waste of rough finished surface of concrete to sides and sofits of floor or roof beams, beam haunching, girders, bressummers, lintel, cantilever, shelves, including shpports,overhangs, etc, also splayes between floors and beams etc complete all as specified and as directed.
Use and waste Form work rough finished square rectangular or polygonal to sides of pillars, posts, struts, piers columns etc complete all as specified.
Brick work with AAC Block of size 625x200x230 straight or curve on plan, exceeding 6m mean radius built in CM 1:6 complete all as specified.
Steel ventilators with top hung shutter including hinges,steel peg stay, and painting with one shop coat of zinc chromate primer complete all as specified and as directed.
Two coats of synthetic enamel paint over a coat of 3 mm thick cement based wall care putty on newly plastered surface of wall complete all as specified and as directed.
Two coats of synthetic enamel paint over a coat of red oxide primer to new steel surface including preparartion of surface complete all as specified and directed
50 mm thick PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in plinth protection complete all as specified and directed.
Moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified.
Plain cement cencrete type D-2 1:4:8 (40 mm graded aggregate) 75mm thick as in sub base to recieve floor finishes complete all as specified and directed.
25 mm thick cement cencrete type B-0 1:2:4 (12.5mm graded crushed stone aggregate) as in floor finishing, finished surface even and smooth without using extra cement
Plain cement concrete 40 mm thick Plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate to recieve floor finishes complete all as specified.
Mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexazonal or square nut exc 30 cm long and dia of neck not exceeding 12 mm complete all as specified.
35 mm thick 2nd class hard wood plain framed panelled shutter (two panels) of factory made with lock rail and panel of 12 mm thick veneered particle board with commercial vace veneering on both faces including wooden beads on both sides, one coat of pink primer. The size of rail and stile as per IS-1003 part-I kiln seasoned and chemically pressure treated complete all as specified and directed.
Butt hinges ISI marked of mild steel cold rolled medium weight of size 100mm as specified
E/M portion
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside serviceable items for reuse with in the same bldg and removing U/S items from site.
Point wiring with Single core PVC (FRLS) insulated, unsheathed, stranderd copper conductor of size 1.5 sqmm including earth lead of 1.5 sqmm with same specification drawing in & including PVC non metalic rigid casing & caping/conduit with MS/CI sunken box of wall thickness not less than 1.6 mm including plastic laminated sheet of 3 mm thick for mounting switch, socket and regulators for one light point/fan point controlled by one switch & making good the disturbed surfaces to match with the existing specification complete all as specified & as directed.
All as per item No. 81.00 here in before but for socket outlet 5 Amps on independent board complete all as specified & as directed.
All as per item No. 81.00 here in before but for socket out 5 Amps on same board complete all as specified & as directed.
All as per item No. 81.00 here in before but wiring with 2.5 sqmm & earth lead of 1.5 sqmm with same specification for socket out 5/15 or 6/16 Amps complete all as specified & as directed.
Switch piano flush type single pole one way 5 amps 240 volts all as specified & as directed.
Socket 5 amps 5 pin, 2 in 1, flush type, 230 volts all as specified & as directed.
Switch piano flush type single pole one way 16 amps 240 volts all as specified & as directed.
Socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts all as specified & as directed.
Ceiling rose 3 phase/PVC/polycarbonate isolated body surface bakelite 2 to 3 terminals all as specified & as directed.
Angle Lamp holder insulated body with back plate for batten fittings and including one 9 Watt LED Bulb non dimmable B-22 cool daylight all as specified and direccted.
LED Tube light fitting, 1x 18 watts, 4 feet. Decorative ultra slim linear LED lighting fixture with co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed. Cat part No LUMILINEBS18WLED865PCWH of Havells or equivalent of make C&S, Wipro,Philips
Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, including earth work in any type of soil remaing surplus excavated material all as required at site and specified in Electrical plate No 5 of SSR part I 2009 or directed by Engineer-in-charge.
Sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) Make:- Legrand Cat Pt No 607711 or equivalent in Havells/L&T/C&S
Sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) Make:- Legrand Cat Pt No 607711 or equivalent in Havells/L&T/C&S
MCB single pole, 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
MCB single pole & neutral 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
Supply and fix in repairs high efficiency 2'X2' recess LED flat panel light 36 W LED 6000 K edge lite luminarie suitable for armstrong grid ceiling complete for low ceiling applications complete all acessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size cat part VENUSNEOHE2X2R36WLED84OPI of Make Havells or equivalent in CG/Bajaj
LED Tube light fitting, complete with T-5 LED 20 watts, 4 feet. decorative PVC extruded body with all acessories, prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed. Cat part No LTTB4F20WLEDP/W, (NAKSHATRA P SERIES) of C&S or equivalent of make Havells/Wipro/Philips
Surface mounted LED bulk head fitting (e-trata) plastic housing with clear prismatic diffuser and lamp holders etc complete with all acessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size cat part No. CG80IB6WLED of C&S or equivalent of make Havells/Wipro/Philips
Electronic fan regulator , step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed.
Metallic body body exhaust fan heavy duty 250 mm sweep single phase working on 230 volts AC supply 50 Hz 1400 RPM including fixing arrangement with cutting hole on walls including connecting electrically using PVC insulated overall sheathed flexible copper conductor cable 0.75sqmm all as required and directed.
Service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular all as required or directed.
House Service bracket (hook type) complete with 3.0 mm long G.I pipe 40 mm dia (medium grade), two numbers 90° bends, M.S hook and stay including taking down the existing unserviceable bracket. NOTE :- The unit rate shall be deemed to include for :-(a) Cutting holes in walls etc. of any description, grouting rag bolts and making good with cement mortor 1:3 including making good finishing to match the existing work and removing rubbish off the premises as directed (in case of bracket being fixed to masonry wall).
XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables for service connections (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core, all as specified & directed.
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth and manhole not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified.
Returning, filling including spreading leveling watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as directed.
Removing excavating material (soil) n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified
Sand cushioning for the purpose of laying of cables complete all as specified and directed.
Brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class ‘B’ laid in trenches flat complete all as specified and directed.
M/s Kay Aar Enterprises
M/s Parvesh Gupta
M/s Mool Raj Romesh Chander
M/S RAHUL GUPTA
M/S MINTA & CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .