Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹53.8 L+₹4.1 L (8.27%)Rejected-Finance HOSPITAL ROAD TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical OLD MISSAMARI PO GARUBANDHA PS MISSAMARI DISTT SONITPUR ASSAM 784506 | MISSAMARI | SONITPUR | ASSAM | 784506 | - | Rejected-Technical Not recommended due to not in category. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not recommended due to remove from command approved list |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
21 Oct 2022, 6:00 pmClosed
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
SPECIAL REPAIR /REPLACEMENT OF CORRODED PIPE LINE AND WATER TREATMENT PLANT AT AGE CHARDUAR UNDER GE (NORTH) TEZPUR
2022_MES_553059_1
GE(N)/TEZ/2022-23/8652
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (NORTH) TEZPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹97,000
2 Jan 2023
20 Sept 2022
28 Oct 2022
20 Sept 2022
21 Oct 2022
4 Oct 2022
Amount
Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating over areas exceeding 1.5 m but not exceeding 3 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Taking up/down and removing the corroded GI/PPR pipeline from trenches of size 63/32/25mm dia complete all as directed.
Taking up CI/DI water mains 110/100 mm dia (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed
Fixing only 100/110 mm bore of steel tubing/PPR obtained from item Sl No 6 here-in-before including provision of heavy duty ISI marked new GI fittings (Such as socket/ elbow/ Tee/ union/ reducer/ nipple/ flange etc) to wall/flooring /ceiling etc or laid in trenches all as specified.
Taking down existing sluice valve 100/80 mm any type and any size and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.
Supply, laying, jointing and testing of Ductile iron (DI) pipes 100 mm bore with spigot and socket ends, centrifugally cast, class K-7 as per IS:8329-2000 and other relevant standards including material and labour for push on EPDM/SBR Rubber gasket joint in any length laid in trenches complete all as specified and as directed. (Note :- DI fittings and earth work will be measured and paid under relavant item of this schedule)
Material and labour for DI fittings such as Bends, Tapers, Tees, Branch (Single or double branch), connecting pieces etc., any type and angle/ radius etc., confirming to IS 9523-2000 for DI Pipe upto 200 mm bore complete all as specified and as directed
M & L for 3- layer PP-R (Polypropylene random copolymer) pipes 110 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
M & L for 3- layer PP-R (Polypropylene random copolymer) pipes 63 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
M & L for 3- layer PP-R (Polypropylene random copolymer) pipes 32 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
M & L for 3- layer PP-R (Polypropylene random copolymer) pipes 25 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S & F in repair PP-R Gate valves (brass insert), 63 mm nominal size complete all as specified and as directed.
S & F in repairs PP-R Gate valves (brass insert), 32 mm nominal size complete all as specified and as directed.
S & F in repairs PP-R Gate valves (brass insert), 25 mm nominal size complete all as specified and as directed.
S & F in repair for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
M & L for construction of new valve chamber of size 900 mm X 900 mm X 900 mm including necessary earth work in any type of soil, 100 mm thick PCC foundation (1:3:6) type C-2 using 40 mm grade stone aggregate as in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40 mm X 40 mm X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide primer on all metal works & three coats of white wash on all plastered surfaces of valve chambers complete all as specified & directed by Engineer-in-Charge.
M & L for boring under road, pavement, hard standing, by trenchless technology using latest boring technique and necessary machine complete all as specified and as directed.
S& F for cutting of CI/DI pipe 100 mm dia carefullyfor new connection of distribution in position inserting fittings such as bend, tee, socket pieces, collar etc; complete all as specified and as directed.Note: necessary fitting for insertion of hole in DI pipe is incld in the above item no extra cost will be paid.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
Designing, supply, install, testing commissioning iron removal pressure feed type filtration plant 20,000 GPD at Phulbari garrison to withstand to pressure 5.5 Kg/Sqcm with catalytic and filtration media (as required size and grade/mesh to obtain potable water recommended parameters) including MS frontal pipe(duly welded),cocks, butterfly valves (inlet, outlet, back wash, rinse and bypass complete as per manufacture's instruction) provision of man hole, hand hole strainer including air vent system, coagulant feeder with accessories, PCC foundation as per OEM recommendation and connected to rising and delievery system including painting and writing complete with hypo dosing system having 2 nos. pump of 1 LPH electronic type and 50 ltr PVC tank,brief desction of plant given below. IRON REMOVAL FILTER, Flow rate- 7.6 cum/hr, Operating pressure- 3.5- 5.5 Kg/sq cm, Max allowable pressure drop- 0.5 Kg/sqcm, Backwash- 20 min, Rinsing- 10 min, Filtering media detail Media type & Qty- Catalytic media certified to remove iron upto 10 ppm, Catalytic Media- 400 mm, Coarse Sand- 500 mm, Supporting Gravels- 300 mm, Vessels Details, Type cylinder- Vertical, aprrox Dimentions in mm ( DiaXHeight)- 800 X 1800 mm, board boared for back wash- 50% Materials- MS thickness in mm (shell and dish end)- 6/8 mm
Designing, supply, install, testing commissioning iron removal pressure feed type filtration plant 25,000 GPD at 5004 ASC Sonaipam to withstand to pressure 5.5 Kg/cmsq with catalytic and filtration media (as required size and grade/mesh to obtain potable water recommended parameters) including MS frontal pipe(duly welded),cocks, butterfly valves (inlet, outlet, back wash, rinse and bypass complete as per manufacture's instruction) provision of man hole, hand hole strainer including air vent system, coagulant feeder with accessories, PCC foundation as per OEM recommendation and connected to rising and delievery system including painting and writing complete with hypo dosing system having 2 nos. pump of 1 LPH electronic type and 50 ltr PVC tank,brief desction of plant given below. IRON REMOVAL FILTER- Flow rate- 7.6 cum/hr, Operating pressure- 3.5- 5.5 Kg/sq cm, Max allowable pressure drop- 0.5 Kg/sqcm, Backwash- 20 min, Rinsing- 10 min, Filtering media detail Media type & Qty- Catalytic media certified to remove iron upto 10 ppm, Catalytic Media- 400 mm, Coarse Sand- 500 mm, Supporting Gravels- 300 mm, Vessels Details, Type cylinder- Vertical, aprrox Dimentions in mm ( DiaXHeight)- 800 X 1800 mm, Free board for back wash- 50%, Materials- MS thickness in mm (shell and dish end)- 6/8 mm.
M/S LAKSHMI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .