Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹17.1 L+₹50,274 (3.03%)Rejected-AOC | L2 | Rejected-AOC High Rate | |
| 3 | L3₹17.3 L+₹73,366 (4.42%)Rejected-AOC 99 C PIPE ROAD CHINIAMORE PO BARRACKPORE PS TITAGARH DIST 24 PARGANAS N KOLKATA 700120 WB | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L3 | Rejected-AOC High Rate | |
| 4 | L4₹17.5 L+₹96,291 (5.81%)Rejected-AOC | L4 | Rejected-AOC High Rate | |
| 5 | L5₹17.9 L+₹1.3 L (7.71%)Rejected-AOC | L5 | Rejected-AOC High Rate |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
18 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIRS TO ROOF TRETMENT . ROOF GUTTER .ROOF CHAJJA , RALLING ,RWP , CEILING ETC IN MD ACCN (OMQ AND SMQ) AT AT 6 WING AF UNDER GE (AF) BARRACKPORE
2020_MES_407620_2
8271/BKP/AF OR 2020-21
Open Tender
Civil Works - Highways
Item Rate
180 days
6 WING AF BARRACKPORE
Please refer tender documents
5 documents required · 5 mandatory
₹500
GE AF Barrackpore
₹30,000
Yes
4 May 2021
13 Feb 2021
20 Feb 2021
13 Feb 2021
18 Feb 2021
13 Feb 2021
60 days
Amount
Taking down cement plaster of any description from stone or brick walls etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials where directed complete all as specified and directed
Demolition of cement concrete (Unreinforced) in ground floor and paving n exc 15cm thick (below or above ground level) and removing rubbish off the premises complete all as specified.
Demolition of cement concrete (Re-inforced) of any description and in any position not otherwise specifically provided for.
Demolition of brick work build in CM including all quoins, arches, pillars etc complete all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store,15 mm dia bore.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store,20 mm dia bore.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc.6 mtr radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in CM 1:4 as on top chajja caopy and similar sructures mixed with WPC 1% weight of cement finish and finishing (NOTE: WPC will measured and paid separetly)
M&L for rendering 5mm thick backing coat over damaged irregular surfaces of irregular fascia, chajjas and in similar work and also for narrow width etc and rendering dubbing coat 10mm thick cement plaster in CM (1:4) to make good the broken surfaces over a coat of cement (NOTE: WPC will measured and paid separetly)
Supply only Integral water proofing compound
M&L for rendering 5mm thick cement plaster in CM 1:4 as in ceiling and finishing the surface even and smooth with out using extra cement.
M&L for rendering backing coat over damaged irregular surfaces of irregular fascia, chajjas and in similar work and also for narrow width etc and rendering dubbing coat 10mm thick cement plaster in CM (1:4) to make good the broken surfaces over a coat of cement slurry @ 3.00 Kg/Sqm making surface even followed by 5mm thick rendering in CM (1:3) finished even and smooth including chicken wiremeh (where is reqd) including making of drip course as required including roughening surface of RCC/PCC by picking sweeping clean and washing down with water etc complete all as specified and directed.
M&L for Use and waste of form work to bottom of slab thickness exc 200mm.
M&L for three coats of white wash on ceiling surfaces incl preparation of new plastered surfaces.
M&L for dripmould 40mm x 15 mm of size in cm 1:3 finished even & smooth with out using extra cement and using with WPC at 35 by weight of cement or as per manufactures instruction.
M&L for pre-cast RCC slab set in cement mortar (1:4), type A1, (1: 1.5:3)), using 20 mm graded stone aggregate after demolition of reinforced concrete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Cutting out cracks of 'V' sectional grooves on roof top and walls to depth 10mm and width 30mm, filled with DR FIXIT crack filler after appling MPB bonding agent as per manufacture instructions complete all as specified and directed.
M&L for PCC 1:2:4 type B-1(using 20mm graded aggregrate) as in padding, benching, coping, roof kerbs, mud stop etc and similar items including weathering slightly rounded or chamfered angles and throating on top of roof, chajjas, rails, cills etc complete all as directed by Engr-in-charge.
S&F for 110mm bore PVC(SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls incl taking down existing old pipes.
All as per item No 21 here in before but 75mm bore.
S&F PVC (SWR) bends/shoes/access door etc any radius for 110mm bore.
All as per item No 23 here in before but 75mm bore.
Disconnecting of existing tanks, setting aside or lowering if required for repairs, cleaning etc and hoisting if required reconnecting and refixing in position of any size complete all as specified and directed.
S&F 20mm bore steel tubing medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors and including tanking up or down of existing pipe complete all as specified and directed.
S&F 15mm bore steel tubing medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors and including tanking up or down of existing pipe complete all as specified and directed.
S&F 500 ltrs capacity rotational moulded PVC water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position including dismantiling of tank all as specified. SSR Part I.
S&F 1000 ltrs capacity rotational moulded PVC water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position including dismantiling of tank all as specified. SSR Part I : .
S&F 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod and high dencity plastic ball screwed for iron pipe and fixed Make :PARYAG
M&L for providing a name plate of size 900mm x 600mm with 20mm thick plaster in CM 1:4 on external walls of bldg and engraving with Name of Contractor, CA No, Date of Completion and Expiry date of Guarantee period complete all as specified and directed by Engr-in-Charge.
M&L for Providing PCC 1:1.5:3 type A-0 (using 12.5 mm Stone aggregate ) with using WPC @ 2% of weight of cement for leveling course in roof and ceiling finishes cement and smooth .
Taking down existing roof treatment of any description and removing debris or roughening surface of old roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engr-in-Charge.
Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed APP based polymeric membrane and making good ,cutting n, exc. 10cm girth.
M&L for 15mm thick screed bed in CM 1:4 on RCC roof slab of cement as per manufacturer instruction and finishing the surface even and smooth without using extra cement complete all as specified and as directed
Supply and laying of APP based polymeric membrane minimum 3mm thick reinforced with polyster non woven fabric 160 grams per sqm over a bitumin primer @0.25 Ltr / sqm conforming to 3384-1986 and prepared surfaces with transversed lap, longitudional lap and end lap fully torching the joints and providing protecting layer all as per manufacture's instruction.All the materials shall be of same make and application shall be done by authorised applicatros according to manufacture's instructions complete over and applying one coat of aluminium paint over the APP modifide membrane @ 0.11Kg/Sqm complete all as specified and as directed by Engr-in-Charge.the Over laps shall be minimam 100 mm on the transverse direction and 75 mm on logitudinal direction.
Oenix and associates
Renuka Fero Products
BHAUMIK CONSTRUCTION
JAGATRAM CONSTRUCTION
ROY CONSTRUCTION
BUSINESS SYNDICATE
Electro Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .