| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC HARSHA KUTHI SIDDHESWARITALA ROAD MONIRAMPORE BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹49.4 L+₹1.4 L (2.92%)Rejected-Finance 99 C PIPE ROAD CHINIAMORE PO BARRACKPORE PS TITAGARH DIST 24 PARGANAS N KOLKATA 700120 WB | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L2 | Rejected-Finance Rejected being higher than L1 | |
| 3 | L3₹49.4 L+₹1.4 L (3.01%)Rejected-Finance ABANI APARTMENT 1ST FLOOR 6 2 TALBAGAN ROAD WEST PO NONACHANDANPUKUR BARRACKPORE KOLKATA 700 122 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700122 | L3 | Rejected-Finance Rejected being higher than L1 | |
| 4 | L4₹49.5 L+₹1.5 L (3.10%)Rejected-Finance | L4 | Rejected-Finance Rejected being higher than L1 | |
| 5 | L5₹49.5 L+₹1.5 L (3.14%)Rejected-Finance GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-Finance Rejected being higher than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 May 2025, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
SPECIAL REPAIR TO BER E/M EQUIPMENTS AT AF STATION BARRACKPORE (PHASE-II) UNDER GE (AF) BARRACKPORE
2025_MES_706950_1
8590/BKP/AF OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Barrackpore
Class-D,
Category-b(ii)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹90,000
Yes
3 Jul 2025
6 May 2025
29 May 2025
6 May 2025
27 May 2025
20 May 2025
Amount
Taking down BER cooling appliances (AC's ) from site and deposited to MES store yard complete all as specified and directed.
Taking down BER items (exhaust fan & geyser) from site and deposited to MES store yard complete all as specified and directed.
Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 2 Ton with indoor and outdoor unit comprising of the following:- (a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs. (b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs. (c) Key features: - (i) Multi adjustable mode. (ii) High ambient cooling. (iii) Super dry. (iv) Turbo cooling. (v) Anti microbial air filteration. (vi) Eco-friendly refrigerant R-32/ R-410A. (vii) 100% copper. (viii) Sleep mode. (ix) Wide voltage range operation. (x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum). (xi) Cordless remote - 01 No.
Notes: - (i). Extra copper pipe and multistranded copper conductor wire required for Air Conditioner to be installed on parapet wall of building roof top shall deemed to be included in quoted rate. (ii). Rate for scaffolding/ladder/tools and plants required to install Air Conditioner i.e. for making holes to wall, drilling, making good disturbed surfaces and matching with the existing colour shall deemed to be included in quoted rate. (iii) Outdoor unit should be kept above the level of Indoor unit. For installaiton of ground floor ACs oudoor should be on wall surfaces and for first floor ACs should be on parapet wall of roof top of the building with out extra cost to the Govt all as directed by Engr-in-chrg. (iv) The MES No should be painted on indoor and outdoor unit with navy blue colour letters of size not less than 15 mm height. Drain pipe should be clamped up to plinth protection. No extra claim should be allowed for drain pipe from indoor unit to plinth protection of outside the building. (v) The quoted rates are also inclusive of making holes in brick/stone wall for installation of Air Conditioner and making good to the exisitng surface with putty and paint in as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 1.5 Ton with indoor and outdoor unit comprising of the following:- (a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs. (b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs. (c) Key features: - (i) Multi adjustable mode. (ii) High ambient cooling. (iii) Super dry. (iv) Turbo cooling. (v) Anti microbial air filteration. (vi) Eco-friendly refrigerant R-32/ R-410A. (vii) 100% copper. (viii) Sleep mode. (ix) Wide voltage range operation. (x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum). (xi) Cordless remote - 01 No.
Notes: - (i). Extra copper pipe and multistranded copper conductor wire required for Air Conditioner to be installed on parapet wall of building roof top shall deemed to be included in quoted rate. (ii). Rate for scaffolding/ladder/tools and plants required to install Air Conditioner i.e. for making holes to wall, drilling, making good disturbed surfaces and matching with the existing colour shall deemed to be included in quoted rate. (iii) Outdoor unit should be kept above the level of Indoor unit. For installaiton of ground floor ACs oudoor should be on wall surfaces and for first floor ACs should be on parapet wall of roof top of the building with out extra cost to the Govt all as directed by Engr-in-chrg. (iv) The MES No should be painted on indoor and outdoor unit with navy blue colour letters of size not less than 15 mm height. Drain pipe should be clamped up to plinth protection. No extra claim should be allowed for drain pipe from indoor unit to plinth protection of outside the building. (v) The quoted rates are also inclusive of making holes in brick/stone wall for installation of Air Conditioner and making good to the exisitng surface with putty and paint in as specified and directed by Engr-in-charge.
Supply installation testing and commissioning of Electric storage water heater (rust and shock proof body) with attractive looks and corrision resistance inner tank having capacity 25 litre, 5 star rated with multi function safety valve , heating element, indicating lamps etc all as per following specifications :- (a) Power / Input : 8.7 Amp, 230 V, 50 Hz (b) Rated Power input in KW : 2 KW (c) Maximum rated Pressure : 8 Bar (0.8 Mpa) (d) Storage Capacity : 25 litre (e) Installation type : Wall mounted Vertical (f) Mean Hot Water Outlet - 75 degree celcius (g) Mixing factor - 30 % maximum (h) Water Proof degree - IP x 4 (j) Class of appliance - Class I (k) Heating element : Incoloy glass coated heating element, superior heating performance with excellent resistance to both oxidation and carbonization at high temperature setting . Resists corrosion against extreme and hard water conditions with minimum energy loss. Contd...
(l) Inner container : It shall be Feroglass coating, made of ultra thick super cold rolled steel plates with superior corrosion resistance and ' anti-rust property'. (m) Anode rod - The tank has an anode rod with a stainless steel core. (n) Insulation : CFC free thicker PUF insulation. (o) Star Rating : 5 Star from BEE complete all as specified and directed. Make : Jaquar& Company Pvt Ltd / USHA/ AO-Smith.
Supply and fix voltage stablizer for automatic operation ,single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy 2.5% and of capacity 5 KVA complete all as specified and directed. Make : Volina/ V-Guard / Microtek
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep, 1400 RPM with, blades, frame, louvers and making good distributed surface complete all as specified and directed. Note:- The louvers for the exhaust fan shall be made of aluminium sheet suitable and properly fixed to the opening.
All as per item No 7.00 here in before but 380mm sweep, 1400 RPM and -ditto-.
All as per item No 7.00 here in before but 450mm sweep, 1400 RPM and -ditto-.
Material and labour for concealed submain wiring comprising single core , 2 Runs of 2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed. Note :- (a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates. 2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates.
Material and labour for concealed submain wiring comprising single core , 2 Runs of 4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed. Note :- (a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates. 2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates.
Supply and fix in repair split AC mounting bracket stand for outdoor unit suitable for 1.5 Ton / 2.0 Ton AC including necessary mounting bolt complete all as specified and directed.
Supply and fix in repair copper pipe 5/8" dia for connection indoor and out door unit ISI marked complete all as specified and directed.
Supply and fix in repair copper pipe 1/2" dia for connection indoor and out door unit ISI marked complete all as specified and directed.
Supply and fix in repair copper pipe 3/8" dia for connection indoor and out door unit ISI marked complete all as specified and directed.
Supply and fix in repair copper pipe 1/4" dia for connection indoor and out door unit ISI marked complete all as specified and directed.
Supply and fix drain water pipe 15mm dia PVC flexible type for Split/Window type AC of any capacity including taking out unserviceable drain pipe complete all as specified and directed.
Supply and fix in repair industrial plug and socket type DB (functional unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified and directed.
Supply and installation, testing and commissioning of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase + 1 Neutral, 4 wire with off load tappings on HT side to vary secondary voltage within limit, designed & constructed with particular reference to tropical conditions, conforming to Ammended IS : 1180(Part-I) : 2014 Level-2 (Amendment-4) of capacity 400 KVA, built up with class 'A' insulation, cooling type ONAN oil cooled top up/first filling of oil and testing as per standard practice complete all as specified and directed. Specification of Transformer:- (a) Cooling type - ONAN oil cooled as per IS 335, BS 148, D 1473, IEC Pub 296 (b) Winding - Double Copper wound as per ASTM B-49 (c) Air clearance - Min air clearance for HV-HV and LV-LV as per IS 2026 or latest (d) Vector group - DYN-11 & Connection - Delta/Star (e) Impedance - 4.5% (f) Temperature rise in Oil- 40 degree Celcious & Temperature rise in winding- 40 degree Celcious. (g) Transformer tank shall be constructed robust rectangular shape with wall thickness not less than MS plate supported with adequate Angle iron at all corners, joints etc with healthy fabrication method, painted inside with weather proof oil resistance paint, external body painted with weather proof paint after applying healthy zinc chromite primer. (h) Radiators - Press fin type (j) Tapping on HV (%)- +5 to -10 % in step of 2.5% Contd...
TERMINAL ARRANGEMENT: - (a) HV Side : Trifurcating cable box suitable to connect XLPE cable (b) LV Side : Quadfurcating cable box with copper bus bar terminal suitable to connect PVC cable and one additional Neutral Bushing terminal will be brought out separately for earthing purpose. FITTINGS: (a) Externally hand operated Off-circuit Tap switch with position indicator and locking device. (b) Coservator with oil gauge, filling hole with plug & drain hole with plug. (c) Undercarriage with four plain rollers-1 Set (d) Oil filling hole cum air release valve-01 No (e) Drain valve cum sampling valve -01 No (f) Filter valve with plug-01No (g) Rating Plate & Diagram Plate -01 No (h) Lifting lugs for transformer-02 Nos (j) Lifting lugs for Lids- 02 Nos (k) Earthing terminal-02 Nos (l) Thermometer Pocket -01 No (m) Silicagel Breather-01No (n) Inspection cover -01 No (o) Explosion Vent-01 No (p) 6" Dial type Thermometer with alarm, trip contacts and maximum temperature indicator-01 No
All as per ser Item No - 20.00 here in before but of capacity 150KVA -ditto-
NOTE FOR ITEM NO 19.00 TO 21.00:- (a) All the arrangements for loading unloading and placement on platform and disconnecting old unserviceable transformer & stablizer shall be deposited/shifted to MES Store yard by the contractor without any extra cost. (b) Contractor shall submit test certificate from the manufacturer and CP vouchers before processing the RAR. (c) Contractor shall get the make, specification and drawing approved prior to placing order. (d) Contractor shall arrange factory inspection of transformer before despatching it from factory. (e) All defects shall be rectified at site till the satisfaction of Engineer in Charge. (f) Testing of transformer at various load factors shall be done at site with the help of OEM technician till achieving satisfactory result at site in front of Engineer-in-Charge. (g) All the HT/LT UG cables shall be properly connected it at their respective terminals without any any contact before testing. (h) Contractor should submitt warranty certificate of Transformer & Stablizer from OEM.
Renuka Fero Products (BID ID -3306367)
Globe Electricals (BID ID -3306264)
PIONEER TRADING (BID ID -3306208)
JADAV CONSTRUCTION (BID ID -3306446)
PIONEER (BID ID -3306181)
ROY CONSTRUCTION (BID ID -3306162)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .