| 1 | Admitted-Finance KATORATAL STREET KASHIPUR U S NAGAR | DEHRADUN | UTTARAKHAND | 248001 | Admitted-Finance |
| 2 | Admitted-Finance 00 KANOONGOPURA NORTH MAHILA DISTRICT HOSPITAL BAHRAICH BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | Admitted-Finance |
| 3 | Admitted-Finance NARAYAN NAGAR BAZPUR ROAD KASHIPUR U S NAGAR | KASHIPUR | UDHAM SINGH NAGAR | UTTARAKHAND | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical CC 1 BOOTH NO 8 JANTA BHAWAN ROAD SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | Not Admitted-Fee/PreQual/Technical Others-Not submitted hard copy of tender. |
Tender Value
Refer Docs
Closing Date
14 Dec 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Distribution Circle, Rudrapur ( U.S. Nagar )
Construction of independent underground line from 33/11KV S/s, Sec-3 to M/s. AMPP Auto Ltd., SIDCUL, under EDD,Rudrapur.
2021_UPCL3_39034_1
EDC(USN) 31/2021-22
Open Tender
Electrical Works
Item Rate
30 days
Rudrpur
Pl refer tender document.
3 documents required · 3 mandatory
₹2,360
SE,EDC,Rudrapur
Exempted
24 Dec 2021
29 Nov 2021
15 Dec 2021
29 Nov 2021
14 Dec 2021
29 Nov 2021
180 days
Amount
De-Centrilized material ( Supply).
Supply of G.I. Pipe 6"dia, 8feet long( Pipe and collars must be new and perfectly sound, free of cracks and standatrd nominal diameter and length. Contractor shall submit of manufactuers test certificate when even demanded by Engineer-In-Charge or his authorized representative. The pipes shall be protected during handling against impact,shocks and free fall to avoid cracks and damages.
Supply of HDPE Pipe 4/6"dia suitable for 3x120sq.mm. cable .
Supply of Earth wire clmap for S.P.-55 made of M.S. flat of size 65X8 mm. with 65x16mm size Bolt, Nut & washers duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs, complete in all respect as per sample
Supply of Cable holding clmap for S.P.-55 made of M.S. flat of size 65X8 mm. with 65x16mm size Bolt, Nut & washers duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs, complete in all respect as per sample
Supply of Double Pole clmap for S.P.-55 made of M.S. flat of size 65X8 mm. with 65x16mm size Bolt, Nut & washers duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs, complete in all respect as per sample
G.I. Nuts and Bolts suitable size.
Labour Charges.
Cartage from Haldwani/Rudrapur store centre of UPCL to dump store approximatre, distance 05KM to 40 KM including loading and unloading into truckand unloading at JE store dump and carriage from dump store to pit site. STP SP-55
Cartage of different line material from Haldwani/Rudrapur store centre of UPCL to dump store approximatre, distance 05KM to 40 KM KM including loading and unloading into truckand unloading at JE store dump and carriage from dump store to pit site
Erection of double pole,STP,SP-55 support( Supplied by department) on 300x300x75 mm. stone pad including excavation of pit 0.6x0.6x2.0Mtr & grouting of pole in C.C. ratio 1:4:8 in size 0.45x0.45x1.8 mtr. and making kicking block of size ( Height 0.45x0.45 Mtr. round) above ground level on the pole in s:3:6 CC, including cost of drilling holes and cutting as required and cost of all material( Sand,Cement and stone grit) required for the work construction work as per direction of Engineer-In-Charge.
Fixing of M.S earthling rod 20x2500 mm for earthing of supports as per RESPO drawing . No RES-12 including driving earth rod 2.5 mtr deep below ground Earthing of Pole by way of diging of pit size ( 50x750x990)mm. deep of earth. Elecltode in to 1000mm. below found level fixing and connection of GI wire 7/16 swg both electrode end. as per direction of Engineer-In-Charge.
Laying of Cable 33KV XLPE Cable 3x120 sq.mm. in normal soil by digging of trench 1050 mm. deep, 750mm wide. The cable must be separated by a partrtion to single brick. The work includes supplying of find sand & bricks, refilling and ramming of the left out soil, closing the trench and levelling. As per direction of Engineer-In-Charge.
Laying of33KV XLPE Cable 3x120 sq.mm cable laying by trehchless method with HDPE Pipe of suitable size having thickness 6mm by HDD,,machine Medhod. as per direction of Engineer-In-Charge.
Eraction & Commissioning of 33KV. VCB in all respect making connection complete including testing and commissioning. as per direction of Engineer-In-Charge.
Filling and fixing of 33KV. Termination kit 3x120 sq.mm. Indoor.
Filling and fixing of 33KV. Termination kit 3x120 sq.mm. Outdoor.
Construction of metering room size 12x12sq.feet at substation end inc luding cost of building material and it also include the cost of the gate.10 feet hight. as per direction of Engineer-In-Charge.
Extension of control room 10x10sq.fit with Civil work.at substation end inc luding cost of building material as per direction of Engineer-In-Charge.
Installation of 33KV. Metering cubical in meter room with grouting and making all connection.as per direction of Engineer-In-Charge.
UTTARANCHAL ENTERPRISES
Shakti Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .