Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC 26 NEW AVAS VIKAS COLONY DELHI ROAD SAHARANPUR UP | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹20.0 L+₹33,295 (1.69%)Rejected-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L2 | Rejected-Finance Being 2nd lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
19 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Clement Town
GE Clement Town MES Dehradun
ADDN/ ALTN TO BLDG NO. CAMP 23/2, BK-12 AND BK-17 AT CLEMENT TOWN
2021_MES_477147_1
GE/CLT/ Of 2021-22
Open Tender
Civil Works
Item Rate
270 days
GE Clement Town
Class E Cat a(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹48,000
Yes
14 Dec 2021
23 Sept 2021
21 Oct 2021
23 Sept 2021
19 Oct 2021
8 Oct 2021
60 days
Amount
Dismantling asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa and 150AZ as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa and 150AZ as in roof covering/cladding to wall, ridge etc fixed with self tapping screws complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for Non Skid coloured ceramic tiles 10mm thick grade-4 (square/ rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm (600x600mm) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar (1:6) and over and including 25mm thick PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate complete all as specified and directed. (Note :- Shade, colour design and pattern shall be got approved by GE)
M&L for Non Skid coloured ceramic tiles 10mm thick grade-4 (square/ rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm (600x600mm) as in vertical surface such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM (1:4) to recieve tiles complete all as specified and directed. (Note :- Shade, colour design and pattern shall be got approved by GE)
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for GI snap grid framework including 12mm thick micro tegular edged with GRG (Glass fibre reinforced Gypsum) false ceiling tiles of size (595mm x 595mm) (with suitable grid size) including necessary notching and preparing holes and hangers 2mm dia GI adjusting level fixed to structural members. Galvanised steel section of exposes T section grid with exposed flange faces duly powder coated white/ivory colour. The suspension system consisting of perimeter wall angle of size 20x20x0.45mm of GS sheet to secured on wall/partition face with the help of rawl plug screws @450mm c/c. Universal T shaped main runner with single rotatary stiching of size 35x24mm made from 0.33mm thick GS sheet of length 3.60m to be spaced @1200mm c/c. Cross T shaped runner of size 25x24mm with double thick GS sheet 0.25mm thick spaced @ 600mm c/c. To form 600x600mm size module, intermediate T shaped cross runner of size 25x24mm made from 0.25mm thick GS sheet of length 600mm is placed inside the module of size 1200x600mm including suspension of the ceiling frame from structural members with 2mm thick GI wire and level adjusters all cut out etc to the required line and shape as per manufacturer recommendations complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 15mm thick plaster in CM (1:6) on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of internal surfaces of wall and applying two coats of acrylic distemper including a coat of primer of approved tint over a coat of wall care putty complete all as specified and directed.
M&L for applying two coats of Acrylic distemper (using roller) of approved tint over a coat of wall care putty on internal walls after complete removal of existing treatment from wall surface by mechanical sander (rpm 1500-2700) complete all as specified and directed.
M&L for 15mm thick plaster in CM (1:4) on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of Acrylic exterior emulsion paint using roller over a coat of primer after preparation of newly plastered/concrete surfaces on external wall surface complete all as specified and directed.
M&L for applying two coats of acrylic exterior emulsion paint after complete removal of existing treatment by mechanical sander (rpm 1500-2700) including preparation of old plastered/concrete surfaces on external wall complete all as specified and directed.
Taking down chowkhats or frames area n. exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but n. exc 2 sqm each complete all as specified and directed.
S&F 30mm thick flush shutter solid core construction with block board core and ply wood face panels, commercial type both sides and pasting 0.9mm thick decorative laminated sheet on both sides of door shutter complete all as specified and directed.
S&F second class timber framed wrought hard-wood as in frame work complete all as specified and directed.
S&F 30mm thick 2nd class hard wood factory made glazed and skelton shutter, open rebated and prepaned to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as per SSR Part-I complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint to new undecorated wooden surfaces over a coat of pink primer including preparation, over 10cm width or girth complete all as specified and directed.
S&F window/ventilator prepainted section of frame 72x55mm fixed to wall or concrete surface with shutters made of galvanised steel powder coated and section of shutter 47x20mm, mulion section 72x50mm (Base steel as per IS 513 "D" quality galvanized as per IS 277 with zinc of 120 gms/Sqm) glazed and wire gauge shutter prepared to receive wiremesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made made of 10mm square bars powder coated fixed to window frame with screws at 150mm c/c both ways, 4 mm thick sheet glass, 0.36mm stainless steel wire cloth i.e. 1.4mm aperture and necessary fittings and all builders hardware such as handles, tower bolts & stays etc complete all as specified and directed.
S&F 250mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F 100mm size mild steel butt hinges medium weight, cold rolled complete all as specified and directed.
S&F 200mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and directed.
S&F mild steel pressed handles of size 125mm long stove enamelled black complete all as specified and directed.
S&F mild steel 160mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (Using 40mm graded crushed stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and smooth complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed.
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed.
Dismantling and taking down carefully U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified & directed.
Dismantling and taking down carefully sub-main wiring/service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified and directed.
Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified and directed.
Material and labour for point wiring with 1.5 sq mm PVC insulated, unsheathed, stranded copper conductor (FRLS) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface,provision of CI/Pressed steel terminal switch box with plastic laminated sheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLS ) as earth wire connected with main common earth dolly complete all as specified and directed for the following :-
One light/fan/bell/exhaust fan point controlled by other switches 06 Amp.
One 3pin 5 Amps socket out let on same board controlled by other switches complete all specified and directed.
One 3pin 5 Amps socket out let on independent board controlled by other switches complete all specified and directed .
All as per item No 35 above but with 2.5 Sqmm PVC insulated FRLS cable for 15 Amps power point complete all as specified & directed.
Supply and fixing switch piano flush type single pole, one-way 5 Amps, 240 Volts AC complete all as specified & directed.
Supply and fixing switch piano flush single pole, one-way 16 Amp, 240 Volts AC complete all as specified & directed.
Supply and fixing socket out let 5 Amps flush type complete all as specified & directed.
Supply and fixing in repair socket out let 5/6 pin , 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC complete all as specified & directed.
Supply and fixing in repair stepped type electronic fan regulator flush socket type 120W complete all as specified & directed.
Supply and fixing ceiling rose 3 terminals, PVC / Polycarbonate, isolated body complete all as specified & directed.
Supply and fixing batton/angle holder insulated bodywith back plate including 09 Watt LED Bulb complete all as specified & directed.
Taking out ceiling fan from existing building again refixing the same ceiling fan connecting up including provision of cable flexible 3 core of suitable size wire from ceiling rose to connect fan complete all as specified & directed.
S& F wall mounted LED batten Box type fitting Blu colour end caps pre-wired LED fitting all as per cat part No DMLN 1 LGT 8-16 with & including LED T8 tubular lamp of make Crompton or equivalent make in Philips / Havells as approved by GE complete all as specified & directed.
S & F in repair LED building security light with bracket and fixing arrangements 25 watt LED with bracket complete all as specified and directed. Cat Part No LSTS-25 CDL-M of Crompton or equivalent make in Havells/ philips as approved by GE complete all as specified and as directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated busbar complete all as specified & directed.
Supply and fixing MCB SP 6 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified & directed.
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity complete all as specified & directed.
Supply and fixing sheet metal enclosure double door type for MCB's DB TPN (triple pole and neutral) 240V AC 4 Way with 200 Amps rated busbar complete all as specified and as directed.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLS ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLS ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified & directed.
Supply and fixing MCB TPN 63 Amp 240 V AC 10 KA repturing capacity complete all as specified & directed.
M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI wire 4mm dia nut bolts etc to earth plate one end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC (1:2:4) type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC (1:2:4) type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed. 2. Unless otherwise specified the rates for PCC/RCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule "A" notes for details.
KAPOOR ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .