| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹8.5 L Quoted ₹8.6 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹14.8 L+₹6.2 L (71.6%)Rejected-AOC 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹14.8 L+₹6.2 L (71.6%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
28 Dec 2021, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/MAINT AND REPLACEMENT OF FIRE PUMPS, FIRE PIPE LINES, FIRE HYDRANT AND ALLIED WORKS FOR FIRE FIGHTING AND FIRE ALARM SYSTEM FOR TECH AND RESIDENTIAL AREA AT DEAL UNDER GE (I) R N D DEHRADUN
2021_MES_493102_1
GE(I)RND/9100/E8/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEHRADUN
Class E Category c (vi) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹16,000
Yes
6 Jan 2022
7 Dec 2021
30 Dec 2021
7 Dec 2021
28 Dec 2021
14 Dec 2021
7 Dec 2021 - 14 Dec 2021
Amount
Disconnecting,removing the water, electric connections and taking out carefully the old existing defective electric motor, 7.5 HP of booster pump / centrifugal pump of any description and in any position, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor 12.5 HP, operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering multistage booster pumps/ centrifugal pumps & testing at workshop and transportation to site & refixing on existing platform complete, all as specified and directed by Engr-in-charge.
All as per item No. 1 here in above but motor of capacity 25.0 HP complete, all as specified and directed by Engr-in-charge.
M&L for Disconnection electrical and water connection of the 12.5/21 HP centrifugal pump and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt etcand fixing the require new parts excluding Item No (a) to (d) complete supply and repair and complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
Supply only shaft suitable for centrifugal pumps
Supply only GM impeller suitable for centrifugal pumps
Supply only MS coupling suitable for centrifugal pumps
Supply only bearing suitable for centrifugal pumps
Disconnecting, removing the water, electric connections and taking out carefully defective booster/centrifugal pump of capacity 105 HP, DSM model of Make Kirloskar,, three phase, 415 V, AC supply and carrying out necessary repairs and replacement of bearing bush, gland plate, impeller, nuts and bolts etc, any trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete, all as specified and directed by Engr-in-Charge.
Dismantling and opening of spare parts for servicing of water cooled DG set of following capacity coupled with alternator, Maintenance and servicing mechanically and electrically, including cleaning, oiling /greasing, removing & replacement of defective / unserviceable parts with new parts,i.e diesel filter /oil filter /Air filter /fan belt /fuel pipe/ engine oil pipe /Engine Oil etc as required at site and manufacturer's instructions and checking of valves & nozzles etc, reassembling the parts of capacity 105 HP/ 75 KW DG set at position ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Srl No. 1.01 here in below)
Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge (iii) Fresh engine oil for DG sets shall be supplied by the contractor and cost of engine oil and filling is deemed to be included under the rates quoted by the contractor for above item.
Disconnecting and taking out carefully old unserviceable valve and Supply & fixing fire hydrant valve 63mm dia single headed including flanges, nut, bolt, washers etc complete all as specified & directed.
Disconnecting and taking out carefully old unserviceable branch pipe and Supply & fixing branch pipe gun metal 63mm instaneous inlet, made threaded outlet, 15mm bore nozzle short, complete all as specified & directed
Disconnecting and taking out carefully old unserviceable hose box and Supply & fix hose box made of 18 gauge MS sheet having a minimum size 800mmx600mmx250mm and a maximum size of 1200mmx600mmx250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fired out side and brilliant white inside yard complete all as specified & directed.
Disconnecting and taking out carefully old unserviceable hose reel drum and Supply & fixing Hose reel drum 30 mtr lenth complete all as specified & directed
Disconnecting and taking out carefully old unserviceable pressure gauge and Supply & fix water pressure gauge 4" dia range 0-14Kg per cm square, complete all as specified.
Disconnecting and taking out carefully old unserviceable sluice valve and supply & fixing sluice valve 100 mm dia with stainless steel spindle CI body class I ISI marked PN 1.6 both end flange and drilled and fixed by means of bolts, nuts and washers including providing rubber insertion of suitable thickness for 150mmmm dia size, complete all as directed.
Same as above item No 11 but 100mm dia
Disconnecting and taking out carefully old unserviceable MS pipe and Supply & laying in trenches MS pipe ERW including specials, nominal dia 80 mm dia size including welding, complete all as specified anddirected by Engineer in charge
Disconnecting and taking out carefully old unserviceable butterfly valve and supply & fixing butterfly valve 100 mm dia both end flange and drilled and fixed by means of bolts, nuts and washers including providing rubber insertion of suitable thickness for 100mm dia size, complete all as directed.
Same as above item No14 but 80mm dia
Same as above item No14 but 63mm dia
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Disconnecting and taking out carefully old unserviceable flange and supply and fixing/joint MS flange including welding with MS pipes, nut, bolts, washers of the following sizes
(a) 80 mm dia
Cutting to cast iron pipes of 80 mm bore before laying in position for insertion of new tees, branches, bend and new connection etc complete all as specified and as directed by Engineer-in-charge
Same as above item No 22 but 100mm dia
Supply & fixing cast iron fittings flange and socketed / all socketed / all flanged type such as bend upto 150mm bore (any type radious and angle) tapers any type (straight, bend, increasing, descreasing or double socket etc), Tee piece single branch, 'Y' junction, double branch cross (all sockets or socket and spigot) collors, caps and plugs as in repairs, excavation earth work and run lead joints tighten joints rubber gasket shall be measured and paid seperately.
53. M&L for construction of brick masonry valve pit of size 750 x 750x 750 mm inside including necessry excavation and earth work and disposal of surplus soil to 50 mtr brick work in cement mortar 1:4, MS angle iron frame, hold fasts, MS sheet cover 3 mm thick includind handle and locking aggangement all as specified and and shown on drawing.
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick masonry including finishing the surfaces even and smooth without using extra cement complete, all as specified and directed by Engr-in-charge.
M&L for providing cement concrete 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete, all as specified and directed by Engr-in-charge.
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 mtr mean radius, old size brick built in Cement Mortar (1:4), for manholes complete, all as specified and directed by Engr-in-charge
Demolition of brick or stone boulder masonary in cement motor or cement lime motor including all quions areches piller atc but excluding ashlar faring dressed stone work and precast concrete articles complete all as specified and directed by Engr-in-charge
Disconnecting and taking out carefully old unserviceable cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area 6 Sqmm 2 core size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out carefully old unserviceable conduit and supply, laying and jointing rigid non metallic PVC conduit of following sizes exclucive of boxes but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts saddles pipe hooks etc.
(a) 25 mm dia
(b) 20 mm dia
Disconnecting and taking out carefully old unserviceable manual call point and supply and fixing manual call point for hooters/siren etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out carefully old unserviceable locking arrangemet and supply and fixing locking arrangement along with lock at fire hose box etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing CO2 fire extinguisher of capacity 4.5 KG for Sub Stns and pump houses complete all as specified and directed by Engr-in-charge
Supply, fixing and testing in replacement of unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, of gun metal globe or gate valve with iron wheel head, both ends screwed for iron pipe, conforming to IS 778 complete, all as specified and directed for following bore of pipes :- (Make: Sant/Bir/ Leader/Upadhaya)
25mm bore
50mm bore
Taking up and Down from each floor and existing location Refilling of fire extinguisher of the following type size and capacity.Fixing existing / new location including pvc sleeve screw etc any requirement for fixing the extinguishers. After refilling the extinguishers testing report will be submited to the Engineer -in- charge. (Note --- Cost of To & Fro cartage from site to plant will be included in quoted rates)
(a) Fire extinguisher Co2 type 4.5 Kg Capacity
(b) Fire extinguisher Mechnical Foam (Stored Pressure) type 9 Ltr Capacity
(c) Fire extinguisher ABC (Stored Pressure) powder type 6 Kg capacity
Supplying & fixing Co2 type 4.5 kgs capacity Fire Extinguisher, assembled from brand new Explosives approved cylinders, complete with screw-down type valve, internal discharge tube, one metre high pressure rayon braided hose, discharge, horn, Bearing ISI Mark IS: 2878. Co2 Cylinder as per IS: 7285 CCE approved ‘ISI’ Valve as per IS: 3224. Co2 Gas as per IS: 15222. internal discharge tube IS: 738. Discharge duration, 10-18 secs. Filled weight of extinguisher, 17 kgs. Tested to 250 kgf/cm2. Make -- Minimax / Safex / Safegaurd
Supplying & fixing ABC type Stored Pressure 6 kgs capacity Fire Extinguisher, fabricated from MS sheets, fitted with brass forged squeeze grip valve assembly incorporated with pressure gauge, initial charge of 5 kgs. ABC Powder(MAP 50%) and pressurized with nitrogen gas. M.S. Body as per IS : 513 Forged Brass valve as per IS: 6912. Bearing ISI Mark IS: 13849. Make -- Minimax / Safex / Safegaurd
Supplying & fixing Mechnical Foam AFFF (Stored Pressure ) 9 Ltr capacity Fire Extinguisher, fabricated from MS sheets, fitted with brass forged squeeze grip valve assembly incorporated with pressure gauge and pressurized with nitrogen gas. M.S. Body Epoxy Polyester Powder Coating and AFFF as per IS 4989 ,Hydraulic test pressure 35 kg/cmm2 and Extinguisher as per IS: 15683 Make -- Minimax / Safex / Safegaurd
Supply, fixing, jointing and testing in replacement of Pressure switches IPS 100 or approved equivalent) including making connections with the control panel and the pressure vessel complete in all respects.The electrical continuity is maintained between contacts NC& COM under normal conditions. The contacts changeover to NO & COM on rise of pressure to preset value all as specified including taking out unserviceable pressure switch and depositing to MES store yard complete all as specified and as directed at site by the Engineer-in-Charge. Make -Indfoss / Danfoss
Disconnecting & taking out unserviceable Gun metal 3 way Fire brigade inlet to down commer line dismantling and opening carefully for servicing over hauling shifted to workshop,material and labour for replacement of unserviceable &worm out GM Parts and rubber packing BNW etc
Material and labour for in repairs / fabrication of base frame with MS Chanel MC-25/50/75/100/125 for foundation of centrifugal pump set incl two coat red oxide and black enamel paint all as specified and as directed by Engineer-in-Charge.
Taking out old rusty MS base frame incl dismentling the pump & moter, breaking PCC foundation complete all as per the site requirement and as directed by the Engr-in-Charge.
Material and labour for painting with one synthetic enamelled paint as per approved colour code of fire fighting Riser Pipe line in Fire nitch ground floor to terrace pipe lines inside the shaft.
Material and labour for painting with one synthetic enamelled paint as per approved colour code of fire fighting station induction motor coupled with fire pump on terrace pump house and multistory bldg.
Supply, fixing, jointing and testing in replacement of electrically operated Electronic Hooter enclosed in MS enclosures of suitable size painted with sythetic enamaled paint red coloured complete with suitable transformer including taking down the existing one complete and depositing to MES store yard all as specified and directed by Engr-in-Charge. Make --- Agni Devices / ASE / Daksh
Supplying and fixing testing and commissioning of Main fire indicating panel, with 8 number of Zones complete vise-versa, necessary controls, LED indicators, auxillary power supply, test, accept & reset, push buttons, local hooter and provision for passing on the signal to the panel, battery back-up for 24 hours normal and 30 min. alarm condition etc. as required. This is to be fixed in stilt floor. and facilities strictly as per IS 2484 and specification.
Supply, fixing, testing and commissioning of 2 x 1.5 sq.mm. solid core copper conductor PVC sheathed Armoured Cable .For Hooter ,MCP to Fire Alarm Panel
Supply & Fixing 4 mm plain glass along with Rubber Beating etc change in FHC.
Supply, fixing, testing Nozzle with shut off valve including 25 mm clipco clamp for Hose Reel of any size complete all as specified. Make --- Minimax / Safex / Safegaurd
Writing letters or figures on Existing FHC (Black, Romon, Italic or Indian) with paint not exc 30cm height complete all as specified and directed by EIC
Testing and minor repair including preventive and periodical maint with renewals of all existing Fire Alarm and fire fighting system once in a month (During 1st or Last week) for 100% serviceabilty of the complete including checking of terrac pump with control panel staters, Jockey pump, pressure switch, presure vessels fire hydrent valves, hose reals, Canvas hose ,Manual Call Point,Electronic Hooters ,Industrial Siren, gate valves, to make 100% serviceability of the complete including checking, cleaning of fire fighting and fire alarm system by removing dust or dirt, cleaning of heavy greasy deposit if any, and indicating eqpts,meters be checked by the opration of trigger device in each at all floors as described the system installed at officers of deal staff of E-4 & E-3, C-13, D-5, D-6 TOTAL--5 Blocks (G+05 story Bldg) of Deal Residental area as directed by Enginer -in-Charge.
(i) The rates quoted shall be inclusive T&P required for carrying repairs and stationery for maintaining records such as daily ,fortnightly,monthly,quarterly and yearly maintenence, complaints book etc all as described by the Engr in charge. (ii) Normally maintaenance shall be carried out in day time but in case of emergency /breakdown, it should be attenend at odd hrs/night times and additional manpower if required will be arranged by the contractor without any extra cost & rates. (iii) The contractor shall provide the service of trained personnel, ITI qualified mechanic and oprator with 3 yrs exeperience & helper shall 12th pass and supervisor shall be minimum diploma certificate holder with 3 yrs exeperience in the trade. (iv) All consumable & maint material such as oil, lubricants, grease, thimbles etc will be deemed to be included in the rate quoted against above schedule. (v) The contractor will use only genuine/original new parts as approved by original equipment manufacturer during repair and old unserviceable materials should be kept at site till verifiaction and proper register to be maintained complete all as specified and directed by Engr-in-charge. (vi) In case any rewinding of motor is required cost of disconnection transportation and reassembling cost shall be deemed to include the quoted rate. Other items such as copper winding wire bushes bearing etc shal be measured and paid seperately under relevent item of Sch A.
M/s R. K. Bhambri
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .