Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2 Cr
EMD Value
₹10 L
Closing Date
16 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Medial Superintendent,
PROVIDING SURGICAL ITEMS P.D.U. Hospital, Rajkot. (Part- 3 of 16 )
267440
2026-2028
Open
Miscellaneous Works
Supply
Rajkot
4 documents required · 2 mandatory · 2 optional
₹15,000
Medical Superintendent, P.D.U. Hospital, Rajkot ( Tender fee common for Part - 1 to 16 )
₹10 L
23 Jan 2026
23 Jan 2026
23 Jan 2026
16 Feb 2026
23 Jan 2026
for single patient AND TWO patients compatible with oxygen pipeline outlets, sola civil hospital.
Ambu Valve,Ambu Hesse Valve,Ambu Paedi Valve,Ruben Valve,Laerdal Valve
Resuscitator volume respectively - 280ml, Pressure limiting valve respectively- 40 cmH2O, Dead space (patient valve) minimum eg 7 ml, Inspiratory resistance minimum- <5 cmH2O (at 50 L/min) Expiratory resistance minimum- <5 cmH2O (at 50 L/min) Bag reservoir volume more than 1.5 liter transparent carrying case
)Resuscitator volume respectively - 600ml, l 2)Pressure limiting valve respectively- 40 cmH2O ,Dead space (patient valve) minimum eg 7 ml, Inspiratory resistance minimum- <5 cmH2O (at 50 L/min) Expiratory resistance minimum- <5 cmH2O (at 50 L/min) Bag reservoir volume more than 1.5 liter Patient connector ISO Ø22/15 mm transparent carrying case
Resuscitator volume respectively - 1630ml Pressure limiting valve respectively- - 60 cmH2O Dead space (patient valve) minimum eg 7 ml Inspiratory resistance minimum- <5 cmH2O (at 50 L/min) Expiratory resistance minimum- <5 cmH2O (at 50 L/min) Bag reservoir volume more than 1.5 liter Patient connector transparent carrying case
Single lumen polyurethane radioopaque CVP catheter with soft tips, Diameter: 4F (18G), 5F (16G), 6F (14G) Length: 15 cm, 20 cm, 30 cm Seldinger guidewire with J-tip Seldinger wire an i.v. catheter, a valve needle to provide a second port in a Y-fixture, Presterile pack, 2)Single lumen polyurethane radioopaque CVP catheter with soft tips, Diameter: 3F (22G), 4F (18G) Diameter: 3F (22G), 4F (18G), 5F (16G), 6F (14G) Diameter: 3F (22G), 4F (18G)
double lumen polyurethane radioopaque CVP catheter with soft tips, Diameter: 4F: 22G/22G, 5F: 18G/20G,Diameter: 7F: 16G/18G/18G, 12F: 16G/12G/12G, Diameter: 5,5F: 20G/22G/22GLength: 15 cm, 20 cm, 25 cm, 30 cm Length: 8 cm, 13 cm, 20 cm,Length: 8 cm, 13 cm, 20 cm Seldinger guidewire with J-tip,a Seldinger needle, an i.v. catheter,a valve needle to provide a second port in a Y-fixture, Presterile pack,
Should be anatomically curved mask, for optimal placement and stability Single molded tube and Cuff · Tactile Indication should be on Pilot Balloon MRI safe and Phthalate free material (Document to submit for Phthalate free material) Cuff Designed to resist back folding – Reinforced TIP Available with sizes 1,1.5,2,2.5,3,4,5 CE US FDA & ISO certified.
Flexible SGA should be Flexible to be positioned away from the surgical site. Thin and soft cuff to establish a seal over airway anatomy. Single molded tube and Cuff Tactile Indication should be on Pilot Balloon MRI safe and Phthalate free material (Document to submit for Phthalate free material) Available with sizes ,2,2.5,3,4,5 CE & ISO certified.
Sterile, Soft, elongated silicone inflatable cuff and back plate, second seal for gastric access to maintain patency of drain tube. Has bite block, Reusable up to forty times. Withstands an oesophageal pressure up to a median of 58 cm H2O. Available with gastric access even in neonatal size starting from 1, 1.5, 2, 2.5, 3, 4, 5. Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure.
Sterile, Soft, elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab. Has bite block. Available with gastric access even in neonatal size starting from 1, 1.5, 2, 2.5, 3, 4, 5. Delivers oropharyngeal leak pressure up to 37 cm H2O and Air Form elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure.
Description
Description
SS 4 castors/wheels two lockable I.V hook , two integrated clamps,Basket,Tray for hfnc,US FDA and CE approved
1.5 m aspiratory limb with spiral heating coil for uniform tubing, expiratory limb,diffusing membrane W/O water trap ,.Auto-fill chamber with dual float mechanism, 0.5 m extension, chamber pressure 8kPA, Integrated MDI port Bacterial viral end expiratory filter., US FDA and CE approved
• Width:-168mm,Height :-135mm,Depth:-88mm, Weight:-355g, Humidifier compatibility, Classification:-AU IIA,NZ lla, EU lla.
• Width:-135mm,• Height:-205mm,• Depth:-15mm,• Weight:-38.25g, Humidifier compatibility,CLASSIFICATION:-AU I; NZ; EU I
FOR HUMIDIFIER
• dual heated circuit,Chamber• Expiratory limb, Inspiratory limb, Adapters, Generator,Pressure manifold, inspiratory length tube1.75,expiratory tubing -1.6m .,compatible with the Servo Controlled Heated Device,Expiratory tubing diffusing membrane,Inspiratory limb with thermal adaptor,resistance of flow of 0.08 ± 0.03 cmH20 • compliance of 0.61± 0.06 mL/cmH20
- Chamber,- Expiratory limb,- Dryline,Adapters, inspiratory tube length 1.75,expiratory tubing length 1.6m,resistance of flow of 0.08 ± 0.03 cmH20 ,compliance of 0.61± 0.06 mL/cmH20,compatible with Servo Controlled Heated Device ,Expiratory tubing with diffusing membrane, Inspiratory limb thermal adaptor.
Chamber,Inspiratory limb,Dryline,Pressure line,Adapters -
- Chamber, Inspiratory limb,Expiratory limb,Dryline, Filter,Adapters -
- -Chamber, Inspiratory limb , Adapter ,Pressure manifold
* for MR-series humidifiers,Auto refills,Dual-float mechanism,Consistent compressible volume allows for consistent delivery of the prescribed waveform
Description
Description
Description
The Shunt catheters should impregnated by patented Advanced Impregnation Process (AIP) throughout the silicone matrix., It’s should have a combination of powerful antibiotics – 0.15percentage Clindamycin and .054percentage Rifampicin., The anti-microbial should help in preventing bacterial colonization on inner lumen and exterior catheter wall.
The Shunt catheters should impregnated by patented Advanced Impregnation Process (AIP) throughout the silicone matrix., It’s should have a combination of powerful antibiotics – 0.15percentage Clindamycin and .054percentage Rifampicin., The anti-microbial should help in preventing bacterial colonization on inner lumen and exterior catheter wall.
The Shunt catheters should impregnated by patented Advanced Impregnation Process (AIP) throughout the silicone matrix., It’s should have a combination of powerful antibiotics – 0.15percentage Clindamycin and .054percentage Rifampicin., The anti-microbial should help in preventing bacterial colonization on inner lumen and exterior catheter wall.
Impregnated with Rifampicin and Clindamycin to avoid infection for 28 days
Impregnated with Rifampicin and Clindamycin to avoid infection for 28 days
Impregnated with Rifampicin and Clindamycin to avoid infection for 28 days
Description
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SURGICAL ITEMS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .