Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹9.8 L+₹36,965 (3.91%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹10.0 L+₹53,960 (5.71%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹10.3 L+₹81,856 (8.66%)Rejected-AOC 800 RAM NAGAR ROORKEE DISTT HARIDWAR UK PIN 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
13 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ REPLACEMENT OF CERTAIN B/R AND E/M ITEMS FOR BLDG. OF TECHNICAL AREA A,B AT IRDE UNDER GE (I) RND DEHRADUN
2023_MES_597007_1
GE(I)RND/9234/E8/23-24
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Class E Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹24,000
Yes
1 Jul 2023
20 May 2023
15 Jun 2023
20 May 2023
13 Jun 2023
30 May 2023
20 May 2023 - 30 May 2023
Amount
M&L PVC Sheet wall panneling of solid thickness 5 mm consisting of pannels of desired size stuck on inner frame work of 50 mm wide strips of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 Kg/cbm density manufactured by ISO-9000 certified companyusing 65 mm long M.S screw shall not more than 200mm. A Groove of 2mm may be left at the joint of two panels for asthetic looks.The exact size of the panels and coorspondingly of the grid may vary depending on the size of the wall. Optionallya U Channel at top, bottom and side edges and strips of 5mm thick PVC sheet of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cementcomplete all as specified and directed Make: Rajsheree Note: The above work excute necessary fittings and scafolding for heighted site.)
M&L vitrified coloured tiles 10 mm thick light shade (square/rectangular) area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm,, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick cement screed bed in cement mortar 1:6 for laying floor finishes with and including Dismantling floor, hearth or wall tiling cement mortarbedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed.
M&L vitrified coloured tiles 10 mm thick dark shade (square/rectangular) area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 10 mm thick rendering in cement mortar (1:4), rough finish to receive the tiles with and including Dismantling floor, hearth or wall tiling cement mortarbedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed.
M&L for non-skid coloured ceramic tiles first quality (of approved class, colour and design/shade) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 10 mm thick rendering in cement mortar (1:4), rough finish to receive the tiles with and including Dismantling floor, hearth or wall tiling cement mortarbedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed complete all as specified & directed
M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of size 300x450x7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles with and including Dismantling floor, hearth or wall tiling cement mortarbedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed.
M & L 75 mm thick for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in subbase for laying floor finishes with and including Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15cm thickness (above or below ground floors) complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed.
S&F in repair white vitreous China wash down water closet pan (pedestal) pattern, and trap (excluding) fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. with and including plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair vitreous china wash hand basin (flat back) of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, MS brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
S&F in repair soap dish brass, chromium plated, fancy type fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
S&F in repair bib taps brass fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair fancy type angular stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F in repair Stop valves 15 mm bore fancy type, CP with long shank & cup (conncelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions
M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane including hacking out old glass from metal / wooden frame etc complete all as specified and directed. Note:- work will be carried out for 2nd to 6th floor.
S&F 4mm thick figureed glass , pin headed type and glazing with oil putty in squares of any description not exceeding .5 sqm in each pane including hacking out glass form metal / wooden frame etc complete all as specified and directed. Note:- Work will be carried out upto 4th floor.
Taking down shutters of aluminium of any description exc. 1 sqm and not exc. 2 sqm each, resecuring and easing, adjusting and refixing in the same opening complete all as specified and directed.
Taking down shutters of aluminium of any description exc. 2 sqm each, resecuring and easing, adjusting and refixing in the same opening complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from frame) exc. 1.50 sqm each not exc 4 sqm each complete all as specified and directed.
S&F Powder Coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary jointing cleats/ glazing clips, rubber neoprene packing, handles 2 Nos in each door , locking arrangment, aluminium snap beading screw etc with and including taking down existing shutter complete all as specified and directed. ( minimum thickness of powder cated should be 50 micron)
S&F Powder Coated aluminium window and ventilator shutters side hung type without sash bars, , aluminium section weighing 0.55kg/m including necessary jointing cleats/ glazing clips, rubber neoprene packing, anodised aluminium snap beading , screws, anodised aluminium fittings such as peg stay 150mm long (1 No) hinges type B-21 100mm long ((2 Nos) suitable handle (1 No) with and including taking down existing shutter complete all as specified and directed.
S&F in repair powder Coated aluminium frame for doors, windows or partition including aluminium beading, hinges of required size,jointing cleats, screws, dash,fastners,plug for fixing with wall, columns etc complete all as specified and directed.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Taking down existing double action floor spring hydraulically regulated and Refixing only after necessary repairs, oiling & greasing etc in proper position with and including proper screw complete all as specified and directed.
S&F in repair aluminium (die cast) body door closer hydraulically regulated, designation No.3 universal type, suitable for doors shutters up to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete allas specified and directed.
Taking down existing door closer hydraulicially regulated and refixing after necessary repairs,oiling & greasing etc in proper position with and including proper screw complete allas specified and directed.
Taking down chowkhats with shutters (without taking off shutters from frame) not exc. 1.50 sqm each complete all as specified and directed.
S&F powder coated aluminium sliding window two track with two glass shutters aluminium powder coated section aluminium cleat, PVC track, bearing, handle locking arangement, rubber beading etc complte fittings as approved. Note Size of aluminium section shall be under :- (i) Two track top and vertical - Jindal main-2010 section No 20829 or equivalent (ii) Two track bottom- Jindal main-2010 section No 20830 or equivalent (iii) Shutter vertical section- Jindal main- 2010 Section 20606 or equivalent (iv) Shutter top and bottom - Jindal Main-2010 Section 20604 or equivalent (v) Shutter vertical middle (interlock) -Jindal Main-2010 section 20605 or equivalent
M&L taking out drapery rod and supply and fixing polyester coloured venetian blind mounted qn doors windows with aluminium hanging channel with sliding wheel rope including all necessary fittings andfixture complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F in repair 1.25mm thickness of laths steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, haps and staple and one shop coat of primer erected in position as indicated, complete : push pull or manual type complete all as specified and directed.
S&F for framed work such as grills, gratings, etc.. With ends of bars shouldered and riveted, or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con-forming to Fe. 290. Gde-E-165 Note (i) :- Work will be carried out upto 6 story in necessary scafolding and safety measures and labour insourance etc complete allas specified and directed.
Fixing only 4.8 mm thick or any thickness of sheet glass ordinary quality in panes exc 0.50 sqm each fixed with & including rubber gasket in aluminium frame work complete all as specified and directed.
S&F in repairs mortice lock, vertical type of size 100 mm with brass body 2 lever complete all as specified and directed.
S&F in repair chromium plated brass hand ablution health fauset with 1.50 meter long flexible tube fancy type with necessary brass nuts & rubber washers cover with chromium plated spring complete all as specified and directed.
S&F in repair 100mm dia cast Iron floor trap, with CP grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) complete all as specified and directed.
S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed
S&F in repairs PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified and directed.
S&F in repairs PVC waste pipe flexible type 32mm dia suitable for coupling 32mm,610mm long for WHB/Sink complete all as specified and directed.
S&F in repair tubular towel rail 20mm dia 600mm long of brass chromimum plated complete all as specified and directed.
S&F in repair for laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors including taking down of existing GI pipe complete all as specified and directed.
S&F in repair for laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors including taking down of existing GI pipe complete all as specified and directed.
M&L for Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipe etc and making good cutting not exc 10cm.complete all as specified and directed.
Disconnecting & taking down existing water tank of capacity exc 500 liter and not exc. 1000 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed.
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete /brick surface in cement mortar 1:6 finished fair and even as in wall complete all as specified and directed.
M&L for Rendering 10 mm thick on fair faces of concrete /brick surface in cement mortar 1:3 finished even and smooth without using extra cement as in ceiling and similar other work complete all as specified and directed.
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A.
M&L two coat of oil bound distemper of required tint on newly plastered surfaces of wall after prepration of surface and over a coat of 3 mm thick wall care puttty complete all as specified and directed.
M&L three coat of white wash on newly plastered surfaces of ceiling including prepration of surface complete all as specified and directed
M & L for preparation of newly plastered surface and applying two coat of weather proof over one coat damproof over a coat of water proof primer on walls complete all as specified and directed.
M&L for Complete removal of existing treatment of old surface of wall / ceilling and washing rubbing down and stoping of distempered and painted surface of wall and applying two coats of weather proof on one coat of damproof over a coat of water proof primer complete all as specified and directed.
S&F in repair PVC water tank covers screw head type including four Nos of PVC nut and bolt in existing PVC water tanks of Cap 500 ltrs to 1000 ltrs cap with fixing arrangement complite all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fitting etc and making good disturbed surfaces of existing walls, floors etc complete all as specified and directed..
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch. Make of cable:Polycab/L&T/Gloster, Make of conduit: Finolex/Polycab/Supreme
All as per Srl item No 57 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board complete all as specified and directed.
All as per Srl item No 57 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independen board complete all as specified and directed.
All as per item No 57 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete.
S&F Modular switch single pole one way 6 amp complete all as specified and directed. Make -Anchor Penta/Legrand/Havells
S&F Modular switch single pole one way 16 amp complete all as specified and directed. Make -Anchor Penta/Legrand/Havells
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete all as specified and directed. Make -Anchor Penta/Legrand/Havells
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete all as specified and directed. Make -Anchor Penta/Legrand/Havells
S&F ceiling rose 3 plates polycarbonate, isolated body complete all as specified and directed. Make - Legrand/Anchor/Havells
S&F modular fan step regulator 120 W 2 module complete complete all as specified and directed. Make -Anchor Penta/Legrand/Havells.
S&F in replacement of UNSV Compact commercial batten with universal batten fitting suitable for single T8 LED tube complete all as specified and directed. Make:Crompton or euivalent in Philips/ Havells
S&F in replacement of UNSV fluorescent tube light with LED tube light 16 Watt T8 double sided connection with built-in driver, THD not more than 10% all as per Crompton or equivalent in philips/Havells as approved.
S&F in replacement of UNSV LED mirror light fitting, 10 watts, 1000 lumens 6500K comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, IP 20 protection and all accessories pre- wired including connecting to mains complete all as directed. Make- Crompton/ Philips/ Havells
Supplying, fixing & testing in replacement UNSV recess mounting in built , 24Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- Shakti or equivalent in CG/Phillips/Havells as approved.
S&F in replacement of UNSV SPN plug and socket enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20/32 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet complete all as specified and directed. Make: Indoasian or equivalent in Legrand/Havells/L&T
S&F in replacement UNSV TPN plug and socket enclosure with triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp, 415 Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet complete all as specified and directed. Make of SPN DB - Legrand/L&T/C&S/Indoasian
M&L in replacement of UNSV sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable FRLS of size 2x6 sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x6 Sqmm as earth continuity conductor complete all as specified and directed. Make of cable: Havells/Polycab/L&T,Make of conduit: Finolex/Polycab/Supreme
M&L in replacement of UNSV sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable FRLS of size 2x10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x10 Sqmm as earth continuity conductor complete all as specified and directed. Make of cable: Havells/Polycab/L&T, Make of conduit: Finolex/Polycab/Supreme
M&L in replacement of UNSV sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable FRLS of size 4x10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x10 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed.Make of cable: Havells/Polycab/L&T, Make of conduit: Finolex/Polycab/ Supreme
S&F in replacement of unsv MCB distribution board SPN, 240 volts, 4 ways , powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand/ Havells/ C&S /Indoasian.
S&F in replacement of UNSV VTPN DB with vertical type load line distribution board ,double door, 4 way, AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 160 Amp MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed. Make of VTPN DB:-Shalabh or equivalent in Havells/C&S/Indoasian.
S&F in replacement of unsv MCB distribution board SPN, 240 volts, 12 ways , powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Shalabh/Legrand/ Havells/ C&S/Indoasian
Supply and fix in replacement of unsv MCCB with MCCB 4 pole,200 Amps 415 volts, 50 Hz, lcs=100% lcu, option for inbuilt or add on module for earth leakage protection, thermal and magnetic adjustable having breaking capacity 16 KA , with thermal magnetic protection unit and testing complete all as specified and directed. Make: Indoasian/L&T/ C&S /Havells
All as per item No 79 above but, MCCB 4 pole ,160 Amps Complete all as specified and directed. Make- Indoasian/L&T/ C&S /Havells
All as per item No 79 above but MCCB 4 pole,125 Amps Complete all as specified and directed. Make- Indoasian/L&T/ C&S /Havells
S&F in replacement of unsv MCB SPN with MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 40 Amps complete all as specified and directed Make - Shalabh/IndoasianL&T/C&S as approved.
S&F in replacement of unsv MCB SP with MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified. Make - Shalabh/IndoasianL&T/C&S as approved.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified and directed.
S&F in replacement of UNSV rigid non metallic 25 mm dia PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces complete all as specified & directed
S&F in replacement of switch socket combination 2 in 1, 3 pin, 5 and 15 Amp universal flush type 6/16 Amps with box (2 hole complete with suitable connection with 2x2.5sqmm and 1x1.5sqmm single core cable length upto 01 mtr complete all as specified and directed. Make: Anchor Penta/Havells/Legrand as approved.
M/S P K ARORA
Bedi Refrigeration Works
sidh builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .