Loading…
Loading…
Tender Value
₹4.6 Cr
EMD Value
₹2.3 L
Closing Date
18 Mar 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
MR Yognarayan sahu(DFLT)
CE(Bilaspur)
Construction of Govt. Girls College Building at Pendra Road. i/c W.S.S.F. Electrification Work.
186116
NIT No. 1001/TC/2025-26
RESTRICTED TENDER
WORKS
11 days
CE(Bilaspur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Bilaspur)
PWD Circle, Bilaspur
Division Pendra
120
11
No
0
186116
18 Mar, 2026 5:00:00 PM IST
23 Mar, 2026 10:00:00 AM IST
25 Feb, 2026 5:00:00 PM IST
NIT No. 1001/TC/2025-26
Construction of Govt. Girls College Building at Pendra Road. i/c W.S.S.F. Electrification Work.
231920.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
46384000.00
2
20 Mar, 2026 5:00:00 PM IST
46384000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 16h 19m
6 documents required · 5 mandatory · 1 optional
₹0
₹2.3 L
25 Feb 2026
25 Feb 2026
23 Mar 2026
25 Feb 2026
18 Mar 2026
25 Feb 2026
20 Mar 2026
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.1.1 :- In all types of soils.
1.6 :- Extra for every additional lift of 1.5 m or part thereof 1.6.1 :- All types of soils
1.26 :- Carriage by mechanical transport upto 5 km lead: 1.26.1 :- Earth
3.1 :- Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.3 :- 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
3.1.2 - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
2.1 :- Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.1.1 :- Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
2.1.3 :- Window sills, anchor blocks, string course, bends, copings, bed plates and like.
2.1.5 :- Columns, Pillars, Piers and likes- rectangular or square in shape
2.1.8 :- Beams, lintels, cantilevers & walls
2.1.13 :- Weather shade, chhajja, Cornices and mouldings
2.1.7 :- Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
2.1.15 :- Stair cases of all types excluding spiral and folded plate type, including risers and landings
3.2 :- Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.2.1 :- 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
3.12 :- Providing and placing in position einforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: 3.12.1 :- Thermo-Mechanically treated bars FE 415
1.25 :- Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) 1.25.1 :- Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm
1.25.2 :- Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
1.25.3 :- Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
7.5.4 :- Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5 :- Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 :- Cement Mortar 1:6 (1 cement : 6 coarse sand)
7.11 :- Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: 7.11.2 :- Cement Mortar 1:4 (1 cement : 4 coarse sand)
7.12 :- Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:
11.2 :- Providing and making 12mm thick cement plaster of mix: 11.2.4 :- In Cement Mortar 1:6 (1 cement : 6 fine sand)
11.3 :- Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: 11.3.4 :- In Cement Mortar 1:6 (1 cement : 6 fine sand)
11.1 :- Providing and making 6mm thick cement plaster of mix: 11.1.2 :- In Cement mortar 1:4 (1 cement : 4 fine sand)
12.79 :- Providing and laying DOUBLE / MULTI CHARGE (minimum 2.0 mm thick layer) VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS : 15622 -2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.: 12.79.1 :- Size 600x600mm thickness 9 to 10 mm
12.74 :- Providing and fixing rectified glazed ceramic Floor tiles of 1 st quality conforming to IS : 15622-2017 of approved make in all colours, shades over 20 mm thick bed of Cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with gray cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with matching pigment complete. 12.74.1 :- Size 300x300mm thickness 7 to 8 mm
12.75 :- Providing and fixing rectified glazed ceramic wall / dado tiles of 1st quality conforming to IS : 15622-2017 of approved make in all colours, shades on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete 12.75.1 :- Size above 300x450mm
12.45 :- 15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) 12.45.2 :- Granite stone black
12.46 :- 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). 12.46.2 :- Granite stone black
12.37 :- Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 12.37.2 :- 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Medium shade using approximately. 50% white cement and 50% ordinary cement.
3.1 :- Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.4 :- 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
9.18 :- Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate primer. 9.18.4 :- Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet.
8.3 :- Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm.
8.12 :- Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 8.12.2 :- 35 mm. thick (single leaf)
8.148 :- Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge 8.148.2 Extruded section Profile size 42x50 mm.
8.149 :- Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. 8.149.2 :- 30 mm thick door shutters with styles and rails of size 60x30 mm
9.47 :- Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: 9.47.1 :- For fixed portion
9.47.2 :- For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/neoprene gasket required (Fittings shall be paid for separately).
9.51 :- Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 9.51.2 :- With float glass panes of 5 mm thickness
8.137 :- Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 8.137.1 :- 300mm
8.138 :- Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 8.138.1 :- 300mm
8.139 :- Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 8.139.2 :- 200 x10mm
8.103 :- Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws: 8.103.1 :- 125 mm
8.143 :- Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. 8.143.2 :- Double
12.3 :- Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.2 :- 50 mm thick
12.25 :- Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like. 12.25.2 :- 40 mm wide
7.12 :- Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: (First Floor)
18.1 :- Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.1.3 :- White Orissa pattern W.C. pan of size 580x440 mm
18.4 :- Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.4.3 :- White wall hung type
18.13 :- Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: 18.13.1 :- Flat back half stall urinal of size 460x380x250mm
18.15 :- Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe, standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required :
18.17 :- Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.5 :- White Oval or round size 550x400mm.
18.19 :- Providing and fixing vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 18.19.1 :- White
18.20 :-Providing and fixing stainless steel AISI-304(18/8) wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.20.1 :- Size 450x380 mm
18.23 :- Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of brackets, cutting and making good the wall wherever required : 18.23.2 :- Size 600x450x200mm
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1 :- 75 mm dia pipe.
18.76.2 :- 110 mm dia pipe.
18.76.3 :- 150 mm dia pipe.
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 :- Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.1 :- 75 mm
18.77.1 :- Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.2 :- 110 mm
Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.3 :- 150 mm
18.77.2 :- Double "Y" with or without door 18.77.2.2 :- 110 mm
18.77.3 :- Vent covel 18.77.3.1 :- 75 mm
Vent covel 18.77.3.2 :-110 mm
18.77.4 :- Access door cap 18.77.44.1 :- 75 mm
Access door cap 18.77.4.2 :- 110 mm
18.77.5 :- "P" trap 110mmx110mm long
18.77.6 :- Nahani trap 110x75mm
18.78 :- Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.1 :- 75 mm
19.4.6 :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL 19.4.6 :- 50 mm nominal outer dia pipes
19.4.5 :-40 mm nominal outer dia .Pipes.
19.4.4 :- 32 mm nominal outer dia .Pipes.
19.5 :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 19.5.4 :- 32 mm nominal outer dia .Pipes.
19.5.3 :- 25 mm nominal outer dia .Pipes.
19.5.1 :- 15 mm nominal outer dia .Pipes.
19.6 :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK 19.6.5 :- 40 mm nominal outer dia pipes
19.6.4 :- 32 mm nominal outer dia pipes
19.10 :- Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured) 19.10.1 :- 25 mm nominal bore
19.10.2 :- 32 mm nominal bore
19.10.3 :-40 mm nominal bore
19.10.4 :- 50 mm nominal bore
19.14 :- Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.1 :- Bib cock (400 grams)
19.14.2 :- Long nose bib cock (500 grams)
19.14.5 :- Two way bib cock (800 grams)
19.14.6 :- Stop cock (concealed) (600 grams)
19.14.11 :- Hand shower set with flexible extension pipe
19.14.15 :- Shower rose (revolving type) (150mm)
19.14.17 :- Towel ring (150 mm dia)
19.15 :- Providing and fixing stainless steel drain jali of approved make/quality.
19.16 :- Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 19.16.1 :-
19.16.2 :- 32 mm nominal bore.
19.16.3 :- 40 mm nominal bore
19.16.4 :- 50 mm nominal bore
19.18 :- Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 19.18.1 :- 25 mm nominal bore
19.42 :- Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
19.49 :- Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
20.2 :- Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 20.2.1 :- 100 mm diameter S.W. pipe
20.2.2 :- 150 mm diameter S.W. pipe
20.31 :- Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
point
21.1 :- Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart /bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. 21.1.1 :- All types of soil 21.1.1.3 :- 150 mm dia.
21.1.2 :- Rocky strata including Boulders. 21.1.2.3 :- 150 mm dia.
21.2 :- Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. 21.2.2 :- Rocky strata including Boulders. 21.2.2.3 :- 150 mm dia.
21.5 :- Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 21.5.3 :- 150 mm nominal dia
21.11 :- Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 21.11.3 :- 150 mm dia
21.12 :- Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 21.12.3 :- 150 mm clamp.
21.14 :- Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately). 21.14.1 :- 21.14.1 Stone boulders of size range 5 cm to 20 cm, in recharge pit
21.14.2 Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
21.14.3 Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 20.5.1 :- 20.5.1 100 mm dia. R.C.C. pipe
20.5.2 150 mm dia. R.C.C. pipe
20.7 :- Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.1 :- 20.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
22.25 :- Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: 22.25.1 :- Hedges like Alife, Dorenta, Tikoma etc
22.25.2 :- Furn like Arica, China etc (3 year old)
22.25.3 :- Hibiscus (Flower)/ Rose
22.25.4 :- Carpet grass (well developed)
metre
1.7 -: Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 -: Short Point
Medium Point
Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
1.11:-Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
1.12:-Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.12.3 :- Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
1.13:- Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1:- 3 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
9 X 2.5 sq. mm in 32mm conduit
12 X 2.5 sq. mm in 32mm conduit
3 X 6 sq. mm in 25mm conduit
3 X 16 sq. mm in 32mm conduit
6 X 4 sq. mm in 32mm conduit
6 X 6 sq. mm in 32mm conduit
6 X 10 sq. mm in 40mm conduit
1.15:- Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.1:- 20 mm
5.4 :- Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.9 :- Fan regulator (two module size) electronic stepped type moving all rounds
Plug Top (Deluxe type) 3 pin 16 Amps (For power plug).
Ceiling rose 3 pin 5 amp
Batten/ angle holder
Blanking plate
5.7:- Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 :- Deluxe
6.1 :- Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 :- 1200 mm sweep
6.6:- Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 :- 300 mm sweep
6.6.3 :- 450 mm sweep
6.8 :- Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.8.2 :- 300 mm sweep
6.11 :- Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.4 :- 120 cm long
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)
6.15 :- Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.6 :- 18/20 Watt
6.17 :- Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.6 :- 15 Watt
6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}
Supplying, installation, testing and commissioning of following LED tube light fitting {Inverter Type: with builtin battery backup} including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification. IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.21.1 20 watt
6.28 :- Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.8 :- 90 watt
7.11 : -Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.4 :- 100 amps
7.16 Providing and making interconnection in cubical panel between BBC and switchgears with following size aluminium strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral).7.16.1 20x5mm (100 amps)
30x5mm (200 amps)
50x5mm (300 amps)
50x6mm (400 amps)
7.17 Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). 7.17.1 10 sqmm (32 amp)
16 sqmm (63 amp)
35 sqmm (125 amps)
7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.2 Above 300 mm and upto 450 mm deep
7.20.Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.1 100 amp (20x5mm)
200 amp (30x5mm)
300 amp (50x5mm)
400 amp (50x6mm)
9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu.9.1.3 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA
4 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 35KA
4 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 35KA
4 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA
4 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA
9.8 :- Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 9.8.6 :- 6way (4 + 12), Double door
8 way (4 + 24), Double door
9.11 :- Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 :- 6 amps to 32 ampss
9.20 :- Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.1 :- 40 amps
10.9 Providing and fixing metal clad, TP&N 4 pole automatic change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification.10.9.4 400 amps
10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification.10.15.5 400/5 amps
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.
12.19 :- Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.1 :- With 3 metre long GI Pipes and 50 kg back filling compound.
Excavation for foundation in soft soil/hard soil including dressing of sides and ramming of bottoms, lifting and getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres
Metre
Metre
14.3 :- Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.3.3 :- 100 mm internal dia
15.1 :- Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.1.16 :- 3.5 x 120 sq. mm.
15.14 Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, copper conductor control /power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification and IS: 694 (2010). 15.14.5 4 x 16 sq. mm
15.29 :- Supplying, fixing and cramping suitable size and all type Copper ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. 15.29.3 :- 16 sq. mm
19.3 Supply of swaged steel tubular pole as per IS 2713 with base plate of size 300x300x6mm welded at bottom, necessary hole for cable entry and earthing stud welded at specified height including painting with one coat of red oxide zinc chromate primer. 19.3.11 Designation 410 SP-32 height 9.00 metre
19.9 Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. 19.9.2 Single Over Hang 1.00 metre Long
Double Over Hang 1.00 metre Long
9.10 Erection of STEEL TUBULAR or "H" BEAM/ ISMB pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation and cement concrete collar of size 0.4 metre dia and 0.50 metre height from ground level including excavation and refilling etc. as per specification of length: 19.10.4 7 metre to 10 metre
Supplying and fixing PVC water tight terminal box of approved make and brand with detachable gland plate in bottom, hinged front openable cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 25x3mm GI flat with 2 No GI nuts bolts complete as per specification. 300x200x125 mm for 3 phase
23.3 Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 23.3.3 2.0 HP, single phase
23.7 Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 23.7.6 32 mm dia.
23.8 :- Supplying and fixing of following sizes GM non return valve ISI mark in the suction/ delivery line etc. as per specification. 23.8.6 :- 32 mm dia.
Metre
23.14 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant.23.14.3 3x4.0 sqmm
23.15 :- Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification. 23.15.3 :- 3x4.0 sqmm
24.20 Supplying of approved make Hiwall split Inverter type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 5 metre of copper piping with insulation etc complete as per specification: 24.20.8 1.5 Ton split type Inverter AC {5 Star}
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
5375177242553121563_186116_Form A.doc
NIT • 0.17 MB
2011703544082642840_186116_LIST OF APPROVED MATERIAL AND ANNEXURE-E.docx
NIT • 0.03 MB
8905499113162932464_186116_NIT.doc
NIT • 0.28 MB
3161794749379588414_186116_Notice.doc
NIT • 0.08 MB
4357582687837143773_186116_BOQ.xls
BOQ • 0.17 MB
Download all tender documents and submit your bid