Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹32.9 L+₹20,782.40 (0.64%)Rejected-Finance 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹34.3 L+₹1.6 L (4.87%)Rejected-Finance MANGERIYA MANGERIYA BHOPALGARGH JODHPUR 342901 | JODHPUR | JODHPUR | RAJASTHAN | 342901 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹36.3 L+₹3.5 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹37.2 L+₹4.5 L (13.8%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹40.0 L
EMD Value
₹79,920
Closing Date
4 Sept 2023, 6:00 pmClosed
Garrsion Engineer Banar
Garrsion Engineer Banar, Jodhpur-342027
REPAIR/MAINT OF LT CABLES, PANELS, FEEDER PILLAR BOXES, POLES AND CONNECTED ITEMS AT ARMY AREA BANAR
2023_MES_612600_1
8823/25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Banar
₹79,920
Yes
19 Sept 2023
7 Aug 2023
6 Sept 2023
7 Aug 2023
4 Sept 2023
21 Aug 2023
Amount
Supply, laying, testing & commissioing of 10 Sqmm 2 core size XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I marked, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including jointing & testing and taking down old U/S cable complete all as specified and as directed Note :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule.
All as per Item Ser No 1.00 above but size 16 sqmm 4 core
All as per Item Ser No 1.00 above but size 25 sqmm 4 core
All as per Item Ser No 1.00 above but size 35 sqmm 3.5 core
All as per Item Ser No 1.00 above but size 50 sqmm 3.5 core
All as per Item Ser No 1.00 above but size 120 sqmm 3.5 core
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole as a foundation or in any situation all as specified and directed.
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole by demolition of existing /broken coping with taking out the LT cables and GI pipe Etc and refixing in new coping or in any situation all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified and directed.
All as per item No 9.00 here in before but exc 1.5 mtr or part there of in depth beyond the first 1.5 mtr depth complete all as specified and directed by Engineer-in-Charge..
Material and labour for Sand cushioning/ Sand covering using Tibba sand for underground cable protection complete all as specified and directed by Engineer-in-Charge. Note :- For the purpose of payment, only punned thickness witch comes out 18 cm will be measured.
Supply and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmx150mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and all as specified and directed.
Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement GI Pipe light grade 80 mm dia with necessary accessories/ fittings bracing with pol/wall by FI clamps made with 32x6mm for cable protections/pole for crossing of culverts/nallah and all as specified and directed sizes:-
All as per Item Ser No 15.00 above but of size 50 mm dia
All as per Item Ser No 15.00 above but of size 40 mm dia
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings all as directed.
Arranging fault locating machine to locate the fault in underground elect power cables of any length and any type of 1100 Volts grade LT cable and pin point the fault and testing of the cable after locating fault and cutting the cable at fault to check healthiness of cable before and after fixing the joint including excavation and earth work in any type of soil complete. Note : Cable joints and cable shall be measured and paid separately under respective item of Schedule 'A'.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 16- 35 Sqmm x 3.5 core/4 core and including taking out cable from faulty portion in any situation/position complete all as specified.
All as per Item Ser No 20.00 above but of size 50-70 Sqmm x 3.5 core
All as per Item Ser No 20.00 above but of size 95-120 Sqmm x 3.5 core
All as per Item Ser No 20.00 above but of size 150-185 Sqmm x 3.5 core
All as per Item Ser No 20.00 above but of size 240-300 Sqmm x 3.5 core
Supply, fixing and testing end joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 10-35 Sqmm x 3.5 core and including taking out cable from faulty portion in any situation/position complete all as specified and directed.
All as per Item Ser No 25.00 above but of size 50-70 Sqmm x 3.5 core
All as per Item Ser No 25.00 above but of size 95-120 Sqmm x 3.5 core
All as per Item Ser No 25.00 above but of size 150-185 Sqmm x 3.5 core
All as per Item Ser No 25.00 above but of size 240-300 Sqmm x 3.5 core
Material and labour for disconnecting power supply from LT ACB of cap. 800/1000/1500 Amps for repair works , taking out trolly unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part , cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly all as directed, inserting trolley inside and testing and putting on load complete all as specified and directed .
Supply, installing, testing and commissioning in replacement of factory made Bus bar chamber outdoor type, double door with canopy made out of 3.15 mm CRC sheet siemens gray seven tank process coated, front opening type, size of box not less than 750 mm x 750mm x 400mm with 600 Amps aluminium bus bar including 03 Nos indicating lamp and all the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm duly grouted in PCC 1:3:6 complete all as specified.
Supply, installing, testing and commissioning in replacement of factory made Bus bar chamber outdoor type, double door with canopy made out of 3.15 mm CRC sheet siemens gray seven tank process coated, front opening type, size of box not less than 750 mm x 750mm x 400mm with 4 Nos 200 Amps aluminium bus bar and with 125 Amp 4 pole 16 KA MCCB-01 Nos,100 Amp 4 pole 16 KA MCCB-01 Nos, TPN 63 Amp - 01 Nos, SPN 40 Amp - 02 Nos, SPN including 03 Nos indicating lamp and all the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6 complete all as specified.
Supply and fixing in renewal of change over switch on load 4 pole, 415 Volts 50 Hz 100 Amps open execution type mounted on existing any type/description of LT Panel/feeder pillar with minor modifications of existing LT Panel/Feeder Pillar box to fix and connecting terminals and making fresh connections of cables are deemed in quoted rate of this item and complete.
All as per Item Ser No 33.00 above but of 160 Amps Capacity
All as per Item Ser No 33.00 above but of 630 Amps Capacity
Supply and fixing in replacement off load change over switch 4 pole, 415 Volts 50 Hz 63 Amps side handle fixed on wall/angle iron and connecting terminals and making fresh connections of cables are deemed in quoted rate of this item and complete.
All as per Item Ser No 36.00 above but 100 Amps Capacity
Supply & fixing Aluminium terminal (lugs) suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 16- 35 Sqmm x 3.5 core/4 core and including taking out cable from faulty portion in any situation/position complete all as specified and directed
All as per Item Ser No 38.00 above but of size 50-70 Sqmm x 3.5 core
All as per Item Ser No 38.00 above but of size 95-120 Sqmm x 3.5 core
All as per Item Ser No 38.00 above but of size 150-185 Sqmm x 3.5 core
All as per Item Ser No 38.00 above but of size 240-300 Sqmm x 3.5 core
Repair & maintenance of LT Panel board in door/outdoor type comprising of MCCBs as incoming and outgoing with digital mettering and control wiring by disconnecting all incoming and out going connection, opening of LT cable incl reconnect the cable by excavating the loop and making connection tight by replacing the suitable size of heavy duty lugs with new nut bolts and washers and gland complete. Cleaning of all compartment from in side and out side including using anti rust spray and checking and repair of all controls, switches, meters. etc (if found diffective) and painting complete panel board with two coat of synthetic enamel paint over a coat of red-oxide paint, after necessary scrapping and denting. Refixing of panel board on new angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6 B2 type complete. Note: 1. The MCCBs,MCBs. gland, Voltmeter meter, amp meter will be measured and paid saperately in respective Sch A item. 2. The cost of 50x50x6 mm angle iron frame & PCC work is deemed to be included in quoted rates.
S&F MCCB,4 pole 63 Amp 25 KA , breaking capacity suitable for 415 volts, 50HZ 3 Phase,confirming to IEC 60947-2 (2003) with Thermal and magnetic release with adjustable setting, over load and short circuit setting on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
All as per Item Ser No 44.00 above but of capacity 100 Amps,4pole 415 volts 25KA
All as per Item Ser No 44.00 above but of capacity 125 Amps,4pole 415 volts 25KA
S&F MCCB,4 pole 160 Amp 25 KA , breaking capacity suitable for 415 volts, 50HZ 3 Phase, confirming to IEC 60947-2 (2003) with Microprocessor based release with adjustable setting, over load and short circuit setting on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified
All as per Item Ser No 47.00 above but of capacity 200 Amps,4pole 415 volts 36KA
All as per Item Ser No 47.00 above but of capacity 250 Amps,4pole 415 volts 36KA
All as per Item Ser No 47.00 above but of capacity 315 Amps,4pole 415 volts 36KA
All as per Item Ser No 47.00 above but of capacity 400 Amps,4pole 415 volts 36KA
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 16-35 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 50-95 sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel for 120-185 sqmm cablecomplete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel for 240-300 sqmm cable complete all as specified and directed.
Supply and Fixing in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified and directed.
Supply and Fixing in replacement of Digital Amp Meter 0-400 Amp with CT of same rating including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified and directed.
Supply and Fixing in replacement of Mild steel sliding door bolts plate type, stove enamelled black, with bright bolt not less than 12mm dia, 200mm long bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed on front side door of LT panel board and all as specified and directrd.
Material and labour for repairing/replacing the broken hinges of LT panel shutters with stainless steel hinges of 200mm long by welding/bracing with nut bolts of existing LT panels shutters of any descreption and all as specified and directed.
M&L for writing numbering of LT Panel outdoor/indoor type in appropriate size of letters using synthetic enamel paint all as specified and directed by engineer in charge.
Material and labour for edging the machine cut /true dressed jodhpur stone patti of size 30 cm in width, 60 cm long and 50 mm thick, to make edge aroung the LT Panels and all as specified and directed.
Supply and laying the graded coarse aggregate 40mm size for loose filling around the LT Panels or 2/4/6 poles structure including surface dressing and cleaning the vegetation before spreading the gravel and complte all as specified..
Material and labor for fixing in replacement of 3.15 mm thick CRCA sheet on existing LT panel color and made shape of inner shells and outer shells of panels and making curve/angle to maintain slope of top sheet of panel to make the indoor type to outdoor type with the support of FI 25x3mm thick support, fixing with bullet screws where ever required including two coats of synthetic enamel painting to match with the existing complete all as specified.
M&L for fixing in replacement of heat shrinkable insulated aluminum bus bar with color coding of current rating upto 600 Amp fixing on existing LT panels by making hole,bent to shape or drilling/grinding the busbar to fix on porcelain/PVC insulators with nut bolts and all as specified and directed.
M&L in replacement of earthing with Galvanised Steel earthplate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). Note: Testing of earthing shall be carried out after completion of earthing.Payment for earthing shall be admissible after satisfactory test result.
M&L in replacement of GI strip of size 32x6 mm including mounting on PVC/Porcelain insulators on wall and burried in ground depth not less than 60 cm in ground complete all as specified and directed by Engineer-in-Charge.
Labor for cutting and removing grass, vegetation, bushes/shrubs etc from surrounding of 02 Pole/ 4 Pole structure and LT/ HT Panel E/M installations and removing all rubbish and dressing the gravel/soil and spraying the one time herbicide approved brand (Roundup/Noweed) to prevent the further vegetation and all as specified and directed.
Restretching aluminium conductors including GI wire on existing over head lines without removing, including unbinding from insulator and rebinding to insulator using aluminium binding wire, connections of incoming and outgoing cables, binding with spacers where required and trimming the tree branches with clearance of 3 mtr around of the LT OH line, complete all as specified Note :- (i) Length of span shall be 40 to 50m (Any numbers of wires). (ii) Due care shall be given while resagging of overhead conductor that there shall be no damage to pin/post/disc insulator and pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department (iv) T&P will be provided by contractor without any extra cost.
Dismantling and taking down old ACSR conductor from HT Line complete all as specified and directed by Engr-in-Charge.
M&L ACSR conductor including binding of wire and providing jumpers at the end as per site requirement complete all as specified and directed by Engr-in-Charge.
Re-fixing and restretching of old serviceable (ACSR) conductor obtained from items Ser No 69.00 here in before including binding complete all as specified and directed.
S&F Pin type, pocelain, vitreous, white brow or green insulator including one galvanised mild steel spindle, two galvaanised iron washers and one galvanised iron nut, 100mm height, 65 mm dia for 1100 volts grade with fixing on existing 2 pole/4pole/single pole including taking down of old unsv insulator and all as specified and directed.
Supply only Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps (31 x 5mm), washers, insulators bolts 14mm, washers and nuts, working pressure 1100 volts, height 100 mm, 115mm dia, complete all as specified
S&F PVC seperators/spacers clamp mounted on ACSR conductor suitable for 4 run complete all as specified.
S&F PVC seperators/spacers clamp mounted on ACSR conductor suitable for 2 run complete all as specified.
Supply and fixing in replacement of cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holesfor bolt. In any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint and all as specified and directed.
M&L for painting black and white strips 05 Nos (each strips of 30 cm height) with synthetic enamel paint of black and white colour round the PCC/steel tubular pole alternatevely from the bottom of the pole and also including numbering of pole on both sides with black paint in Yellow background complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement of loop-in/loop-out box of outer size 205x255x112mm made out of FRP body (hot mulded type) with IP-63 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, up to 100 Amp rated 3 pole connector suitable to insert the cable size 25 Sqmm-01 No,with neutral link and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cales and all as specified and directed.
Supply and fixing in replacement of loop-in/loop-out box of outer minimum size 300x200x120mm mdae out of FRP body (hot mulded type) with IP-66 protection and locking with screws comprising of aluminum bus bar rating 100 Amp, 4 strips for 3 phase and neutral along with 6 Amp rating MCB SP-01 No and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and outgoing cables and embossing/painting of danger notice board of size not less than 10cmx7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of box body comple all as specified.
Trimming and cutting of tree branches coming across LT over head line, clearing alround 3m the LT line and disposal of branches/bushes to a distance upto 50m and cleaning the site complete all as directed. Note :- (i) Length of span shall be 40 to 45m. (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department and T&P will be provoded by conractor.
Taking out faulty underground LT 1100 volts grade heavy duty, armoured with steel strip of wire, with stranded aluminium conductor of sizes up to 25 Sqm any core by excavation and removing Jodhpur Stone of any size and relaying same laocation or any other location afeter rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new PCC cable covers as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation, PCC Cover, Sand and earth work will be measured and paid for seperately under respective items of schedule.
All as per Item Ser No 81.00 above but of size 35 Sqmm to 95 Sqmm
All as per Item Ser No 81.00 above but of size 150 Sqmm to 240 Sqmm
Supply and errecting in replacement of Prestressed concrete pole, 9.0 meter long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and setting aside within 50 mtr distance and opening the street light bracket/crossarms with connected items and street light fitting from old pole and refixing the same on new pole for street light fitting and all as required at site or directed by Engr-in-charge.
S&F in replacement of GI stay assembly set comprising of 14mm dia 400mm iron stay bow and16mm dia, 2150mm long stay rod stay plate 230x230x6mm thick, GI stay wire 7/8 SWG of required length complete with all accessories as shown in electric plate No 1 of SSR Part 1 2009 complete with excavation earth work including PCC 1:3:6 of required quantity with loop insulator, clamps nut bolts etc complete all as required and directed.
Supply and installation, testing and commissioning in replacement LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 600A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor will be approved by Accepting Officer before placing order. MCCB 4P 400 Amp 36 KA Microprocessor based release with adjustable setting (incoming) - 01 Nos MCCB 4P 200 Amp 36 KA Microprocessor based release with adjustable setting type(outging)- 2 Nos MCCB 4P 100 Amp 36 KA thermal and magnetic release with adjustable setting (outging) - 01 Nos MCB TPN 415 Volt 10 KA 'B' 63 Amp (outging) - 01 Nos Digital type volt meter up to 500 V Digital type Ammeter 500 Amp LED type Indicating Lamp (03 Nos)
Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 600A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor will be approved by Accepting Officer before placing order. MCCB 4P 400 Amp 36 KA Microprocessor based release with adjustable setting (incoming) - 01 Nos MCCB 4P 250 Amp 36 KA Microprocessor based release with adjustable setting (outgoing) - 01 Nos MCCB 4P 125 Amp 36 KA Microprocessor based release with adjustable setting (outgoing) - 01 Nos MCCB 4P 100 Amp 36 KA thermal and magnatic release with adjustable setting (outgoing) - 01 Nos MCB TPN 415 Volt 10 KA 'B' 63 Amp (outgoing) - 02 Nos Digital type volt meter up to 500 V Digital type Ammeter 500 Amp LED type Indicating Lamp (03 Nos)
Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor will be approved by Accepting Officer before placing order. MCCB 4P 250 Amp 36 KA Microprocessor based release with adjustable setting (incoming) - 01 Nos MCCB 4P 200 Amp 36 KA Microprocessor based release with adjustable setting (outgoing) - 01 Nos MCCB 4P 63 Amp 36 KA thermal and magnatic release with adjustable setting (outgoing) - 02 Nos MCB 240V, 10KA 'C' curve 32 Amp (outgoing) Digital type volt meter up to 500 V Digital type Ammeter 500 Amp LED type Indicating Lamp (03 Nos)
Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 300 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor will be approved by Accepting Officer before placing order. MCCB 4P 200 Amp 36 KAMicroprocessor based release with adjustable setting (incoming) - 01 Nos MCCB 4P 160 Amp 36 KA Microprocessor based release with adjustable setting (outgoing) - 01 Nos MCCB 4P 63 Amp 36 KA thermal and magnatic release with adjustable setting (outgoing) - 02 Nos MCB TPN 415 Volt 10 KA 'B' 63 Amp (outgoing) - 01 Nos MCB SPN 240V, 10KA 'C' curve 32 Amp (outgoing) - 01 Nos Digital type volt meter up to 500 V Digital type Ammeter 500 Amp LED type Indicating Lamp (03 Nos)
Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 200 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor will be approved by Accepting Officer before placing order. MCCB 4P 100 Amp 36 KA thermal and magnatic release with adjustable setting (incoming) - 01 Nos MCCB 4P 63 Amp 36 KA thermal and magnatic release with adjustable setting (outgoing) - 01 Nos MCB TPN 415 Volt 10 KA 'B' 63 Amp (outgoing) - 02 Nos MCB SPN 240V, 10KA 'C' curve 32 Amp (outgoing) - 02 Nos Digital type volt meter up to 500 V Digital type Ammeter 500 Amp LED type Indicating Lamp (03 Nos)
new india engineers
M/s JOG SINGH MATERIALS
LOKESH ELECTRICAL WORKS CONTRACTOR
Anil Builders
INDO CONSTRUCTION
M/s Vishaka Enterprises
GITANSH ENGINEERS AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .