Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC first lowest | |
| 2 | L2₹9.0 L+₹92,687.40 (11.5%)Rejected-AOC 3 5557 A SIVARAM TOWER MATTANNUR 670702 KERALA | KANNUR | KERALA | 670702 | L2 | Rejected-AOC second lowest |
Tender Value
₹8.2 L
EMD Value
₹20,900
Closing Date
12 Mar 2018, 5:00 pmClosed
Assistant Engineer(south)
Assistant Engineer(south) LSGD Engineering wing Thalassery Municipality
ELECTRIFICATION WORK OF VARIOUS BUILDING IN THALASSERY MUNICIPALITY (SOUTH SECTION)
2018_LSGD_186116_2
E6-2068/18
Open Tender
Electrical Works
Item Rate
90 days
Thalassery Municipality
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,904
Yes
online
₹20,900
Yes
8 Jan 2021
26 Feb 2018
16 Mar 2018
26 Feb 2018
12 Mar 2018
26 Feb 2018
26 Feb 2018 - 12 Mar 2018
Amount
Appendix A Electrification of Anganavady centre Nos 73/W31,77/W27 (Paral, Mamballikkunnu & Anganavady Kendram in ward 29
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing Switch Board main and continuous earthing with No. 1.5 , required qtgreen coloured FR wire required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white ) up to and including 6 A modular type ROHS complaint SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control celing fan point & with socket size stepped electronic regulator
Combined plug point .
Independent plug point
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.directly on wall or celing with PVC cround block neatly painted to suit the fittin and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connection as required
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube
Supply, conveyance, installation, testing and commissioning of pre wired light fitting made from .5mm CRCA sheet complete with all accessories and lamps etc directly on wall using 2 nos C/U brackets made from 20x3mm MS flat painting the flat iron bracket and giving connection with required length of 16/.2mm 3core copper conducter flex wire confoming to relevant ISS or extending the original wiring and giving connection etc required
1x28WT5 fitting with lamp holder ,APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminum body, epoxy power coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall /cieling including giving connections with required length of 16/0.20mm PVC insulatored and PVC sheathed 3core round copper conducter flex wire confrming to relevant ISS or extending the original wiring and making good the surface as required.
S&F angle/straight brass lined bakelite batten holder and giving connections etc.as required.
S&P 14 WBC / ES retrofite CFL in the existing fittings as required.
SCITC of 1200mm sweep ( category B)-5 star rated ceiling fan and giving connection with 16/0.20mm PVC& PVC 3 core round copper conducter flux wire or with extended original wire etc.as required.
S&F MS rod type fan clamp as per IS 732 as required.
S&F the following type / sizes of boxes & front plates suitable for modular accessories in surface/recess (ROHS)
3 module metal box with front plates in recess .
6 module metal box with front plates in recess .
S&F the following modular switches and accessories in the existing front plates and giving necessary connection as required.(Group B)
6 A SP I way switch
16 A SP I way switch
6A universal socket
6/16A combined socket
S&F 20mm dia light gauge of PVC conduit confoming to IS 9537/1983part III with its special on surface etc as required
25mmdia light gauge with specials as service pipe
Supply &drawing 650/1100 V grade PVC insulator stranded single core copper conductor cables confoming to IS 694 part I 1990 in the existing surface or recess conduit as required including giving necessary connection of the following sizes .
1.50 sqmm 2 run
2.50 sqmm 2 run
4 sqmm 2 run
Supply &drawing bare earthing conductor of the 2mm copper conductor (14 SWG)along with wiring /cables and giving connection as required
2.65mm copper conductor (12SWG)
3.15mm copper conductor (10SWG)
Supply of superior quality copper earth socket for the 2mm/2.65mm of earh conductor including crimping etc as required.
do-2.65/3,15mm (12/10SWG)
Supply and providing 25x3 mm brass bolt & nut with washers on the existing MS box/earth bus etc.as required including drilling necessary holes as required
do-25x6mm brass bolt &nut
Supply and installation of sheet steel ,phosphatised and painted ,dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link,earth bus and DIN rail suitable for fixing MCB/isolator etc.fixed on wall using suitable anchor bolts or fixed in recess including cutting hole onthe wall making good the damages ,colour washing etc.as required.
8 way single phase double cover(IP 42/43)
12 way single phase double cover(IP 42/43)
Supply and installation of the following accessories suitable for 50Hz AC supply conforming to IS 8828-1995/IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
25A, 2 pole,30m A RCCB
40A 2 pole mini break isolator
6A to 32 A ,10KA,SP MCB (C Curve)
Supplying and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20mm GI watering pipe fixed to the earth plate with 20x3mm GI clamps ,GI funnel with weld mesh.filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick)brick work in cement mortar 1:4 12mm thick ( the finished inside dimension shall be 300x300x300mm)but excluding test joint ,with earth continuity conducter to the plate, and covering at the top ( in ordinary soil)
do- 300x300x6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
S&P test joint for the earthing system using 2x25x3mm GI srip including cutting and bending to shape ,drilling necessary holes and fixed to thewatering pipe etc.as required.
S&P earth lead from test joints to earth plate using 25x3mm GI strip
Supply and laying 10.SWG bare earthing conducters laid 0.60m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary bsoil)
Supply and instalation of 32A 230V 50Hz AC 23A duty,SPN switch discoted unit (front hand )in sheet steel encloure complete with handle assembly ,door interlock and pad locking the arrangement of the following ratings on existing angle iron frame work directly to wall using necessory bolts and nuts fixing the unit to wall making good the damages colour washing etc including giving necessory connection as required
Fabrication , supply and installation of dust and vermin proof,wall mounting thermoplastic meter box of following size suitable for fixing KSEB fuse units ,CT etc . Hinged door construction for the front side with compartment if necessary ,providing vision panel for the meter compartment ,knock out for cable entry and exit.
S&F32 A fuse holder for BS type blade fuses accessories in the existing meter board and giving connections etc.
20-32A ,bolted offset tag type fuse link of size A1
32A ,415V,2 way neutral link mounted on DMC/SMC base
S&F iron hook grouted on wall for binding GI wire
Supplying threading `laying and jointing of 16mm 'B'class GI pipe with all required accessories in ground in the existing trenches
Appendix B Electrification of Pakal Visrama Kendram at Karal Theru under Thalassery Muncipality
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing Switch Board main and continuous earthing with No. 1.5 , required qtgreen coloured FR wire required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white ) up to and including 6 A modular type ROHS complaint SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control celing fan point & with socket size stepped electronic regulator
Combined plug point .
Independent plug point
Supply, conveyance, installation, testing and commissioning of pre wired light fitting made from .5mm CRCA sheet complete with all accessories and lamps etc directly on wall using 2 nos C/U brackets made from 20x3mm MS flat painting the flat iron bracket and giving connection with required length of 16/.2mm 3core copper conducter flex wire confoming to relevant ISS or extending the original wiring and giving connection etc required
1x28WT5 fitting with lamp holder ,APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.directly on wall or celing with PVC cround block neatly painted to suit the fittin and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connection as required
SCITC street light fitting with 20W LED Streetlight with asymetric beam angle 130x50 degree with Liminiare efficiency more than 851 m/W rugged aluminium alloy housing with all accessories complete (OSRAM STRADA Plus 20W 6500K, Lumen/ watt>80) on existing pipe and giving connection with 24/0.20mm 3 core flex
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminum body, epoxy power coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall /cieling including giving connections with required length of 16/0.20mm PVC insulatored and PVC sheathed 3core round copper conducter flex wire confrming to relevant ISS or extending the original wiring and making good the surface as required.
S&F angle / straight brass lined bakelite batten holder and giving connection etc as required.
S&P 14W BC/ES retrofit CFL in the existing fittings as required
SCITC of 1200 mm sweep (Category B)- 5star rated ceiling fan and giving connection with 16/0.20mm PVC & PVC 3core round copper conductor flex wire or with extended original wiring etc as required.
S&F MS rod type fan clamp as per IS 732 as required
Supply, conveyance, installation, testing and commissioning of the folloewing sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts making good
200mm single phase ,light duty exhaust fan in plastic body with self opening louvers.
S&F the following types/sizes of boxes & front plates suitable for modular accessories in surafce/ recess (ROHS)
3 module metal box with front plate in recess
6 module metal box with front plate in recess
S&F the following modular switches and accessories in the existing front plates and giving necessary connections as required (Group B)
6A SP 1 way switch
6A SP 1 way switch
6A Universal socket
6/16A combined socket
20A DP switch with ind
S&F 20mm dia light gauge of PVC Conduit conforming to IS 9537 /1983 part III with its special on surface as required
25mm dia light gauge with specials as service pipe.
Supply and drawing 650/1100V grade PVC insulated standard single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.
1.50 sq mm 2 run
2.50 sq mm 2 run
4.00 sq mm 2 run
Supply and drawing bare earthing conductors of the 2.00mm copper conductor (14 SWG) along with wiring /Cables and giving connection as required.
2.65 mm copper conductor (12 SWG)
3.15 mm copper conductor (10 SWG)
Supply of superior quality copper earth socket for the 2.00mm /2.65 mm of earth conductor including crimping etc as required.
do- 2.65/3.15 mm (12/10 SWG)
Supply and providing 25x3 mm brass bolt &nut with washers on the existing MS box/ earth bus etc as required including drilling necessary holes as required.
do- 25x6 mm brass bolt &nut
Supply and installation of sheet steel ,phosphatised and painted ,dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link,earth bus and DIN rail suitable for fixing MCB/isolator etc.fixed on wall using suitable anchor bolts or fixed in recess including cutting hole onthe wall making good the damages ,colour washing etc.as required.
8 way single phase double cover(IP 42/43)
10 way single phase double cover(IP 42/43)
Supply and installation of the following accessories suitable for 50Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required.
25A, 2 pole ,30mA RCCB
40A ,2 pole mini break isolator
6A to 32 A, 10kA, SP MCB (C curve)
Supplying and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20mm GI watering pipe fixed to the earth plate with 20x3mm GI clamps ,GI funnel with weld mesh.filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick)brick work in cement mortar 1:4 12mm thick ( the finished inside dimension shall be 300x300x300mm)but excluding test joint ,with earth continuity conducter to the plate, and covering at the top ( in ordinary soil)
do- 300x300x6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
S&P test joint for the earthing system using 2x25x3mm GI srip including cutting and bending to shape ,drilling necessary holes and fixed to thewatering pipe etc.as required.
S&P earth lead from test joints to earth plate using 25x3mm GI strip
Supply and laying 10.SWG bare earthing conducters laid 0.60m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary bsoil)
Supply and instalation of 32A 230V 50Hz AC 23A duty,SPN switch discoted unit (front hand )in sheet steel encloure complete with handle assembly ,door interlock and pad locking the arrangement of the following ratings on existing angle iron frame work directly to wall using necessory bolts and nuts fixing the unit to wall making good the damages colour washing etc including giving necessory connection as required
Fabrication , supply and installation of dust and vermin proof,wall mounting thermoplastic meter box of following size suitable for fixing KSEB fuse units ,CT etc . Hinged door construction for the front side with compartment if necessary ,providing vision panel for the meter compartment ,knock out for cable entry and exit.
S&F32 A fuse holder for BS type blade fuses accessories in the existing meter board and giving connections etc.
20-32A ,bolted offset tag type fuse link of size A1
32A ,415V,2 way neutral link mounted on DMC/SMC base
S&F iron hook grouted on wall for binding GI wire
Appendix C Electrification of Kallil Thazhe Sub Centre of PHC Kodiyeri under Thalassery Muncipality
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing Switch Board main and continuous earthing with No. 1.5 , required qtgreen coloured FR wire required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white ) up to and including 6 A modular type ROHS complaint SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control celing fan point & with socket size stepped electronic regulator
Combined plug point .
Independent plug point
Call bell point with piano type 6A bell push at one end 6A, 3plate ceiling rose at other end
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.directly on wall or celing with PVC cround block neatly painted to suit the fittin and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connection as required
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube
Supply, conveyance, installation, testing and commissioning of pre wired light fitting made from .5mm CRCA sheet complete with all accessories and lamps etc directly on wall using 2 nos C/U brackets made from 20x3mm MS flat painting the flat iron bracket and giving connection with required length of 16/.2mm 3core copper conducter flex wire confoming to relevant ISS or extending the original wiring and giving connection etc required
1x28WT5 fitting with lamp holder ,APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminum body, epoxy power coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall /cieling including giving connections with required length of 16/0.20mm PVC insulatored and PVC sheathed 3core round copper conducter flex wire confrming to relevant ISS or extending the original wiring and making good the surface as required.
Do-20 W LED Street light fitting with aluminium casting, toughed glass cover assemtric beam angle of 130x50 degree with typical luminaire efficiency >80 Lumnen per watt , IP 66 protection on existing GI Pipe and giving connection (stradaplus Osran or equivalant)
Charges for cuttinh holes suitable for accomodating exhaust fans of sizes upto 305mm sweep including plastering,colour washing ec as required.
Supply, conveyance, installation, testing and commissioning of the folloewing sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts making good
200mm single phase ,light duty exhaust fan in plastic body with self opening louvers.
Supply and fixing the superior quality 250 V A.C ding dong bell on 150x100x50mm M.S box and giving connections with required length of 3core ,16/0.20mm, 650/1100 V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevent ISS or with the extended original wiring ,earthing the MS box and making good the surface as required
S&F angle / straight brass lined bakelite batten holder and giving connection etc as required.
S&P 14W BC/ES retrofit CFL in the existing fittings as required
SCITC of 1200 mm sweep (Category B)- 5star rated ceiling fan and giving connection with 16/0.20mm PVC & PVC 3core round copper conductor flex wire or with extended original wiring etc as required.
S&F MS rod type fan clamp as per IS 732 as required
S&F the following types/sizes of boxes & front plates suitable for modular accessories in surafce/ recess (ROHS)
3 module metal box with front plate in recess
6 module metal box with front plate in recess
S&F the following modular switches and accessories in the existing front plates and giving necessary connections as required (Group B)
6A SP 1 way switch
6A SP 1 way switch
6A Universal socket
6/16A combined socket
S&F 20mm dia light gauge of PVC Conduit conforming to IS 9537 /1983 part III with its special on surface as required
25mm dia light gauge with specials as service pipe.
Supply and drawing 650/1100V grade PVC insulated standard single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.
1.50 sq mm 2 run
1.50 sq mm 4 run
2.50 sq mm 2 run
2.50 sq mm 4 run
4.00 sq mm 2 run
Supply and drawing bare earthing conductors of the 2.00mm copper conductor (14 SWG) along with wiring /Cables and giving connection as required.
2.65 mm copper conductor (12 SWG)
3.15 mm copper conductor (10 SWG)
Supply of superior quality copper earth socket for the 2.00mm /2.65 mm of earth conductor including crimping etc as required.
do- 2.65/3.15 mm (12/10 SWG)
Supply and providing 25x3 mm brass bolt &nut with washers on the existing MS box/ earth bus etc as required including drilling necessary holes as required.
do- 25x6 mm brass bolt &nut
Supply and instalation of sheet metal ,phosphatised and painted ,dust and vermin proof enclosure of MCB DB including copper/brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc .fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages ,colour washing etc.as required
12 way single phase double cover (1P 42/43)
Supply and installation of the following accessories suitable for 50Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required.
25A, 2 pole ,30mA RCCB
40A ,2 pole mini break isolator
6A to 32 A, 10kA, SP MCB (C curve)
Supplying and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20mm GI watering pipe fixed to the earth plate with 20x3mm GI clamps ,GI funnel with weld mesh.filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick)brick work in cement mortar 1:4 12mm thick ( the finished inside dimension shall be 300x300x300mm)but excluding test joint ,with earth continuity conducter to the plate, and covering at the top ( in ordinary soil)
do- 300x300x6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
S&P test joint for the earthing system using 2x25x3mm GI srip including cutting and bending to shape ,drilling necessary holes and fixed to thewatering pipe etc.as required.
S&P earth lead from test joints to earth plate using 25x3mm GI strip
Supply and laying 10.SWG bare earthing conducters laid 0.60m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary bsoil)
Supplying, threading,laying and jointing of 16mm B class GI pipe with all required accessories in ground in the existing trench.
Supply and instalation of 32A 230V 50Hz AC 23A duty,SPN switch discoted unit (front hand )in sheet steel encloure complete with handle assembly ,door interlock and pad locking the arrangement of the following ratings on existing angle iron frame work directly to wall using necessory bolts and nuts fixing the unit to wall making good the damages colour washing etc including giving necessory connection as required
Fabrication , supply and installation of dust and vermin proof,wall mounting thermoplastic meter box of following size suitable for fixing KSEB fuse units ,CT etc . Hinged door construction for the front side with compartment if necessary ,providing vision panel for the meter compartment ,knock out for cable entry and exit.
S&F32 A fuse holder for BS type blade fuses accessories in the existing meter board and giving connections etc.
20-32A ,bolted offset tag type fuse link of size A1
32A ,415V,2 way neutral link mounted on DMC/SMC base
S&F iron hook grouted on wall for binding GI wire
Appendix D Electrification Anganavady centre Nos 74/W28,75/W26(Karal theru & Kodiyeri JBS) under Thalassery Muncipality
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing Switch Board main and continuous earthing with No. 1.5 , required qtgreen coloured FR wire required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white ) up to and including 6 A modular type ROHS complaint SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control celing fan point & with socket size stepped electronic regulator
Combined plug point .
Independent plug point
Supply, conveyance, installation, testing and commissioning of pre-wired light fitting made from 0.5mm thick CRCA sheet complete with all accessories and lamps etc. including supplying and fixing ball socket arrangements on PVC round block suspention down rod of 19mm dia MS conduit up to 2x30 cm length including painting and wiring the down rod with 16/.20mm 3coreround copper conductor
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube
Supply, conveyance, installation, testing and commissioning of pre wired light fitting made from .5mm CRCA sheet complete with all accessories and lamps etc directly on wall using 2 nos C/U brackets made from 20x3mm MS flat painting the flat iron bracket and giving connection with required length of 16/.2mm 3core copper conducter flex wire confoming to relevant ISS or extending the original wiring and giving connection etc required
1x28WT5 fitting with lamp holder ,APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminum body, epoxy power coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall /cieling including giving connections with required length of 16/0.20mm PVC insulatored and PVC sheathed 3core round copper conducter flex wire confrming to relevant ISS or extending the original wiring and making good the surface as required.
S&F angle/straight brass lined bakelite batten holder and giving connections etc.as required.
S&F 14 WBC / ES retrofite CFL in the existing fittings as required.
SCITC of 1200mm sweep ( category B)-5 star rated ceiling fan and giving connection with 16/0.20mm PVC& PVC 3 core round copper conducter flux wire or with extended original wire etc.as required.
S&F MS rod type fan clamp as per IS 732 as required.
S&F the following type / sizes of boxes & front plates suitable for modular accessories in surface/recess (ROHS)
3 module metal box with front plates in recess .
6 module metal box with front plates in recess .
S&F the following modular switches and accessories in the existing front plates and giving necessary connection as required.(Group B)
6 A SP I way switch
16 A SP I way switch
6A universal socket
6/16A combined socket
S&F 20mm dia light gauge of PVC conduit confoming to IS 9537/1983part III with its special on surface etc as required
25mmdia light gauge with specials as service pipe
Supply &drawing 650/1100 V grade PVC insulator stranded single core copper conductor cables confoming to IS 694 part I 1990 in the existing surface or recess conduit as required including giving necessary connection of the following sizes .
1.50 sqmm 2 run
2.50 sqmm 2 run
4 sqmm 2 run
Supply &drawing bare earthing conductor of the 2mm copper conductor (14 SWG)along with wiring /cables and giving connection as required
2.65mm copper conductor (12SWG)
3.15mm copper conductor (10SWG)
Supply of superior quality copper earth socket for the 2mm/2.65mm of earh conductor including crimping etc as required.
do-2.65/3,15mm (12/10SWG)
Supply and providing 25x3 mm brass bolt & nut with washers on the existing MS box/earth bus etc.as required including drilling necessary holes as required
do-25x6mm brass bolt &nut
Supply and installation of sheet steel ,phosphatised and painted ,dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link,earth bus and DIN rail suitable for fixing MCB/isolator etc.fixed on wall using suitable anchor bolts or fixed in recess including cutting hole onthe wall making good the damages ,colour washing etc.as required.
8 way single phase double cover(IP 42/43)
Supply and installation of the following accessories suitable for 50Hz AC supply conforming to IS 8828-1995/IEC 60898 of the following current ratings in the existing enclosure and giving connections as required.
25A, 2 pole,30m A RCCB
40A 2 pole mini break isolator
6A to 32 A ,10KA,SP MCB (C Curve)
Supplying and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20mm GI watering pipe fixed to the earth plate with 20x3mm GI clamps ,GI funnel with weld mesh.filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick)brick work in cement mortar 1:4 12mm thick ( the finished inside dimension shall be 300x300x300mm)but excluding test joint ,with earth continuity conducter to the plate, and covering at the top ( in ordinary soil)
do- 300x300x6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
S&P test joint for the earthing system using 2x25x3mm GI srip including cutting and bending to shape ,drilling necessary holes and fixed to thewatering pipe etc.as required.
S&P earth lead from test joints to earth plate using 25x3mm GI strip
Supply and laying 10.SWG bare earthing conducters laid 0.60m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary bsoil)
Supply and instalation of 32A 230V 50Hz AC 23A duty,SPN switch discoted unit (front hand )in sheet steel encloure complete with handle assembly ,door interlock and pad locking the arrangement of the following ratings on existing angle iron frame work directly to wall using necessory bolts and nuts fixing the unit to wall making good the damages colour washing etc including giving necessory connection as required
Fabrication , supply and installation of dust and vermin proof,wall mounting thermoplastic meter box of following size suitable for fixing KSEB fuse units ,CT etc . Hinged door construction for the front side with compartment if necessary ,providing vision panel for the meter compartment ,knock out for cable entry and exit.
S&F32 A fuse holder for BS type blade fuses accessories in the existing meter board and giving connections etc.
20-32A ,bolted offset tag type fuse link of size A1
32A ,415V,2 way neutral link mounted on DMC/SMC base
S&F iron hook grouted on wall for binding GI wire
Supplying threading `laying and jointing of 16mm 'B'class GI pipe with all required accessories in ground in the existing trenches
Appendix E Electrification Anganavady centre Nos 74/W28,75/W26(Karal theru & Kodiyeri JBS) under Thalassery Muncipality
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing Switch Board main and continuous earthing with No. 1.5 , required qtgreen coloured FR wire required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white ) up to and including 6 A modular type ROHS complaint SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control celing fan point & with socket size stepped electronic regulator
Combined plug point .
Independent plug point
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.directly on wall or celing with PVC cround block neatly painted to suit the fittin and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connection as required
1x28WT5 fitting with lamp holder ,APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.
Supply, conveyance, installation, testing and commissioning of pre wired light fitting made from .5mm CRCA sheet complete with all accessories and lamps etc directly on wall using 2 nos C/U brackets made from 20x3mm MS flat painting the flat iron bracket and giving connection with required length of 16/.2mm 3core copper conducter flex wire confoming to relevant ISS or extending the original wiring and giving connection etc required
1x28WT5 fitting with lamp holder ,APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminum body, epoxy power coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall /cieling including giving connections with required length of 16/0.20mm PVC insulatored and PVC sheathed 3core round copper conducter flex wire confrming to relevant ISS or extending the original wiring and making good the surface as required.
S&F angle / straight brass lined bakelite batten holder and giving connection etc as required.
S&P 14W BC/ES retrofit CFL in the existing fittings as required
SCITC of 1200 mm sweep (Category B)- 5star rated ceiling fan and giving connection with 16/0.20mm PVC & PVC 3core round copper conductor flex wire or with extended original wiring etc as required.
S&F MS rod type fan clamp as per IS 732 as required
S&F the following types/sizes of boxes & front plates suitable for modular accessories in surafce/ recess (ROHS)
3 module metal box with front plate in recess
6 module metal box with front plate in recess
S&F the following modular switches and accessories in the existing front plates and giving necessary connections as required (Group B)
6A SP 1 way switch
6A SP 1 way switch
6A Universal socket
6/16A combined socket
S&F 20mm dia light gauge of PVC Conduit conforming to IS 9537 /1983 part III with its special on surface as required
25mm dia light gauge with specials as service pipe.
Supply and drawing 650/1100V grade PVC insulated standard single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.
1.50 sq mm 2 run
2.50 sq mm 2 run
4.00 sq mm 2 run
Supply and drawing bare earthing conductors of the 2.00mm copper conductor (14 SWG) along with wiring /Cables and giving connection as required.
2.65 mm copper conductor (12 SWG)
3.15 mm copper conductor (10 SWG)
Supply of superior quality copper earth socket for the 2.00mm /2.65 mm of earth conductor including crimping etc as required.
do- 2.65/3.15 mm (12/10 SWG)
Supply and providing 25x3 mm brass bolt &nut with washers on the existing MS box/ earth bus etc as required including drilling necessary holes as required.
do- 25x6 mm brass bolt &nut
Supply and installation of sheet steel ,phosphatised and painted ,dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link,earth bus and DIN rail suitable for fixing MCB/isolator etc.fixed on wall using suitable anchor bolts or fixed in recess including cutting hole onthe wall making good the damages ,colour washing etc.as required.
8 way single phase double cover(IP 42/43)
Supply and installation of the following accessories suitable for 50Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required.
25A, 2 pole ,30mA RCCB
40A ,2 pole mini break isolator
6A to 32 A, 10kA, SP MCB (C curve)
Supplying and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20mm GI watering pipe fixed to the earth plate with 20x3mm GI clamps ,GI funnel with weld mesh.filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick)brick work in cement mortar 1:4 12mm thick ( the finished inside dimension shall be 300x300x300mm)but excluding test joint ,with earth continuity conducter to the plate, and covering at the top ( in ordinary soil)
do- 300x300x6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
S&P test joint for the earthing system using 2x25x3mm GI srip including cutting and bending to shape ,drilling necessary holes and fixed to thewatering pipe etc.as required.
S&P earth lead from test joints to earth plate using 25x3mm GI strip
Supply and laying 10.SWG bare earthing conducters laid 0.60m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary bsoil)
Supply and instalation of 32A 230V 50Hz AC 23A duty,SPN switch discoted unit (front hand )in sheet steel encloure complete with handle assembly ,door interlock and pad locking the arrangement of the following ratings on existing angle iron frame work directly to wall using necessory bolts and nuts fixing the unit to wall making good the damages colour washing etc including giving necessory connection as required
Fabrication , supply and installation of dust and vermin proof,wall mounting thermoplastic meter box of following size suitable for fixing KSEB fuse units ,CT etc . Hinged door construction for the front side with compartment if necessary ,providing vision panel for the meter compartment ,knock out for cable entry and exit.
S&F32 A fuse holder for BS type blade fuses accessories in the existing meter board and giving connections etc.
20-32A ,bolted offset tag type fuse link of size A1
32A ,415V,2 way neutral link mounted on DMC/SMC base
S&F iron hook grouted on wall for binding GI wire
Supplying threading grouted laying and jointing of 16mm B class GI pipe with all required accessoreis in ground in the existing trenches
Appendix F Krishibavan anganvadi under Thalassery municipality ward12
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing Switch Board main and continuous earthing with No. 1.5 , required qtgreen coloured FR wire required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white ) up to and including 6 A modular type ROHS complaint SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control celing fan point & with socket size stepped electronic regulator
Combined plug point .
Independent plug point
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.directly on wall or celing with PVC cround block neatly painted to suit the fittin and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connection as required
1x28WT5 fitting with APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube
Supply, conveyance, installation, testing and commissioning of pre wired light fitting made from .5mm CRCA sheet complete with all accessories and lamps etc directly on wall using 2 nos C/U brackets made from 20x3mm MS flat painting the flat iron bracket and giving connection with required length of 16/.2mm 3core copper conducter flex wire confoming to relevant ISS or extending the original wiring and giving connection etc required
1x28WT5 fitting with lamp holder ,APF electronic ballast suitable for continuous operation with THD <10%, power factor >0.98 RoHS complaint high lumen tube.
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminum body, epoxy power coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall /cieling including giving connections with required length of 16/0.20mm PVC insulatored and PVC sheathed 3core round copper conducter flex wire confrming to relevant ISS or extending the original wiring and making good the surface as required.
S&F angle/straight brass lined bakelite batten holder and giving connections etc.as required.
S&F 14 WBC / ES retrofite CFL in the existing fittings as required.
SCITC of 1200mm sweep ( category B)-5 star rated ceiling fan and giving connection with 16/0.20mm PVC& PVC 3 core round copper conducter flux wire or with extended original wire etc.as required.
S&F MS rod type fan clamp as per IS 732 as required.
S&F the following type / sizes of boxes & front plates suitable for modular accessories in surface/recess (ROHS)
3 module metal box with front plates in recess .
6 module metal box with front plates in recess .
S&F the following modular switches and accessories in the existing front plates and giving necessary connection as required.(Group B)
6 A SP I way switch
16 A SP I way switch
6A universal socket
6/16A combined socket
S&F 20mm dia light gauge of PVC conduit confoming to IS 9537/1983part III with its special on surface etc as required
25mmdia light gauge with specials as service pipe
Supply &drawing 650/1100 V grade PVC insulator stranded single core copper conductor cables confoming to IS 694 part I 1990 in the existing surface or recess conduit as required including giving necessary connection of the following sizes .
1.50 sqmm 2 run
2.50 sqmm 2 run
4 sqmm 2 run
Supply &drawing bare earthing conductor of the 2mm copper conductor (14 SWG)along with wiring /cables and giving connection as required
2.65mm copper conductor (12SWG)
3.15mm copper conductor (10SWG)
Supply of superior quality copper earth socket for the 2mm/2.65mm of earh conductor including crimping etc as required.
do-2.65/3,15mm (12/10SWG)
Supply and providing 25x3 mm brass bolt & nut with washers on the existing MS box/earth bus etc.as required including drilling necessary holes as required
do-25x6mm brass bolt &nut
Supply and installation of sheet steel ,phosphatised and painted ,dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link,earth bus and DIN rail suitable for fixing MCB/isolator etc.fixed on wall using suitable anchor bolts or fixed in recess including cutting hole onthe wall making good the damages ,colour washing etc.as required.
12 way single phase double cover(IP 42/43)
Supply and installation of the following accessories suitable for 50Hz AC supply conforming to IS 8828-1995/IEC 60898 of the following current ratings in the existing enclosure and giving connections as required.
25A, 2 pole,30m A RCCB
40A 2 pole mini break isolator
6A to 32 A ,10KA,SP MCB (C Curve)
Supplying and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20mm GI watering pipe fixed to the earth plate with 20x3mm GI clamps ,GI funnel with weld mesh.filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick)brick work in cement mortar 1:4 12mm thick ( the finished inside dimension shall be 300x300x300mm)but excluding test joint ,with earth continuity conducter to the plate, and covering at the top ( in ordinary soil)
do- 300x300x6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
S&P test joint for the earthing system using 2x25x3mm GI srip including cutting and bending to shape ,drilling necessary holes and fixed to thewatering pipe etc.as required.
S&P earth lead from test joints to earth plate using 25x3mm GI strip
Supply and laying 10.SWG bare earthing conducters laid 0.60m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary bsoil)
Supply and instalation of 32A 230V 50Hz AC 23A duty,SPN switch discoted unit (front hand )in sheet steel encloure complete with handle assembly ,door interlock and pad locking the arrangement of the following ratings on existing angle iron frame work directly to wall using necessory bolts and nuts fixing the unit to wall making good the damages colour washing etc including giving necessory connection as required
Fabrication , supply and installation of dust and vermin proof,wall mounting thermoplastic meter box of following size suitable for fixing KSEB fuse units ,CT etc . Hinged door construction for the front side with compartment if necessary ,providing vision panel for the meter compartment ,knock out for cable entry and exit.
S&F32 A fuse holder for BS type blade fuses accessories in the existing meter board and giving connections etc.
20-32A ,bolted offset tag type fuse link of size A1
32A ,415V,2 way neutral link mounted on DMC/SMC base
S&F iron hook grouted on wall for binding GI wire
Do- 20 W LED street light fitting with aluminium casting,toughed glass cover assemtric beam angle of 130x50degree with typical luminaire efficiency >80 lumen per watt ,IP 66 protection on existing GI pipe and giving connection (stradaplus osran equivalent)
SIVARAM.E
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_252122.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .