Loading…
Loading…
Tender Value
₹17.7 L
EMD Value
₹35,400
Closing Date
17 Aug 2026, 12:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SRDEEG/SEE
13 conditions · 2 needing a document upload
Contractor should have to be registered with Employee Provident Fund Organization (EPFO). It is mandatory for contractor to submit PF code provided by EPFO with their tender offer. Also each contractor has to submit "UAN" of their worker with their offer and have to mention in tender document. It is mandatory. Otherwise offer will not be considered for further action and your offer will summarily be rejected.
The tenderer shall posses the valid ElectricalContractor's license andSupervisory License issuedby any State/Central Govt. licensing board for therequired voltage level or above with their tenderpaper. Tenders without valid electrical contractor'slicense & Supervisory license will summarily berejected.
27 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderers whether sole proprietor , a limited company or a partnership firm he/they should submit authentic proof in terms of partnership deed, proprietorship documents etc. along with the tender. If he/they want to act through agent or individual partners should submit a power of attorney duly stamped and authenticated by Notary Public or by Magistrate in favour of specific person whether he/she/they are partners of the firm or any other person specifically authorizing him/her name to submit the tender, sign the agreement , receive money, witness measurements, sign measurement books , compromise, settie, relinquish any claims, preferred by firm and also sign No Claim Certificate and refer all or any disputes arbitration.
Contractor should have to be registered with Employee Provident Fund Organization (EPFO). It is mandatory for contractor to submit PF code provided by EPFO with their tender offer. Also each contractor have to submit "UAN" of their worker with their offer and have to mention in tender document. It is mandatory. Otherwise offer will not be considered for further action and your offer will be summerisely rejected. You are also instructed to submit monthly payment challan to the person/labour engaged for execution of the work having valid UAN no with bill. This is to be followed strictly as per GCC & as per instruction of labour enforcement officer under Govt of India.
Inclusion of 'Letter of Credit' as Mode of Payment in Works Tenders or Service Tenders as per Railway Board's letter no. 2018/CE-I/CT/9 dated 04.06.2016 remarks from Tenderer required.
Eligibility criteria for works tender in respect of partnership firms:-
in case the tenderer is a partnership firm s , the experience, solvency and turn over shall be in the name and style of the firm only.
If the tenderer is a partnership firm, all the partners shall be jointly and severally liable for successful completion of the work and no request for change on the certification of the firm shall be entertained.
During the currency of the contract, no partner of the firm shall be permitted to withdraw from partnership business and in such and event it shall be treated as breach of trust and abandonment of the contract.
JOINT VENTURE will not be permitted for the tenders.
Any Conditional offer will be summarily rejected.
Rates are inclusive of all taxes/GST, license fee, royalty charges etc. legally leviable by State, Central Govt. and/or any other local authority.
Railway Administration reserves the right to change/Alter/Cancel the tender without any notice.
Construction of 4 unit Type VI Quarters at SEE station.
L-Open-26-27-09Dt23-07-26
L-Open-26-27-09Dt23-07-26
Open
Works - General
180 Days
Saran, Bihar
₹0
₹35,400
17 Aug 2026
23 Jul 2026
3 Aug 2026
67 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 17,70,862.64 | ||
| — | 150.00 | — | — | ||
| Wiring for light point/Fan point/Exhaust Fan Point/Call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switches, modular plate, suitable box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. L&T, Legrand , ABB, Havells, Anchor , Roma, C&S, BENLO. | — | — | — | 72,150 | |
| — | 80.00 | — | — | ||
| Supply and fixing of 6 pin 16 Amp Modular switch & socket make L&T, Legrand , ABB, Havells, Anchor , Roma, C&S, BENLO ISI make approved by competent authority. (Fridge & washing machine, water filter) | — | — | — | 21,268 | |
| — | 75.00 | — | — | ||
| Supply and fixing of 5 pin 5 Amp Modular switch & socket, L&T, Legrand , ABB, Havells, Anchor , Roma, C&S ,BENLO ISI make approved by competent authority. | — | — | — | 13,605 | |
| — | 35.00 | — | — | ||
| Wiring for 3 pin 20 Amp. with 2x6 sq.mm. PVC insulated Copper conductor single core with metal plug and socket with enclosure in CRCA sheet steel RAL 9003 power coated confirming to IS8623-1 & 3,IEC 61439-1 & 3 suitable for surface and flush mounting with 32 Amp SP MCB with all respect as per site in-charge. | — | — | — | 42,000 | |
| — | 16.00 | — | — | ||
| Geyser point with MCB connected of 6 pin 16Amp. power plug socket with 2X 2.5 Sq.mm FR PVC insulated copper conductor single core cable in concealed/surface/recessed PVC insulated copper conduit along 1 no.2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required. | — | — | — | 12,728 | |
| — | 300.00 | — | — | ||
| Wiring for submain along with earth wire with the size 2X2.5 sq.mm+1X2.5 sq.mm earth wire of PVC insulated copper conductor, single core cable in concealed/ surface/recessed PVC heavy gauge conduit as required. | — | — | — | 29,403 | |
| — | 500.00 | — | — | ||
| Wiring for submain along with earth wire with the size 2X4 sq.mm+1X4 sq.mm earth wire of PVC insulated copper conductor, single core cable in concealed/ surface/recessed PVC heavy gauge conduit as required. The work shall be done as per CPWD Pt.I, manual(1972) for general specification of electrical work. All materials should be IS marked. | — | — | — | 48,590 | |
| — | 300.00 | — | — | ||
| Wiring for submain along with earth wire with the size 2X6 sq.mm+1X6 sq.mm earth wire of PVC insulated copper conductor, single core cable in concealed/ surface/recessed PVC heavy gauge conduit as required. | — | — | — | 49,800 | |
| — | 8.00 | — | — | ||
| Supply of 4 way MCB- DB. Make-ABB, L&T, Siemens, Schneider, Legrand, Havells, C&S. | — | — | — | 3,875.12 | |
| — | 32.00 | — | — | ||
| Supply of MCB 6-32A. Make-ABB, L&T, Siemens, Schneider, Legrand, Havells, C&S. | — | — | — | 6,792.32 | |
| — | 8.00 | — | — | ||
| Fixing & commissioning of MCB- DB with MCB. | — | — | — | 666 | |
| — | 10.00 | — | — | ||
| GI pipe earthing with 4.5 M long x40mm dia. With salt & charcoal. Make of GI pipe TATA/Jindal or equivalent superior make. | — | — | — | 16,830 | |
| — | 100.00 | — | — | ||
| Supply & Laying of 6SWG GI wire as conductor earth electrode. | — | — | — | 1,032 | |
| — | 50.00 | — | — | ||
| Supply & fix. Of medium class GI pipe 50mm dia. Make TATA/Jindal For protection of UG cable. | — | — | — | 14,835 | |
| — | 2.00 | — | — | ||
| Supply & fixing of 4 strips CU BBC 300mm long made of copper strip suitable for 200Amp. Cap. Complete with all accessories including connection, earthing the body complete etc. as required. Make-Standard/ Havells/Benlo/C&S. | — | — | — | 11,758 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 4 pole MCCB 100A with enclosure. Make - L&T, Siemens, Hager, Legrand , ABB, Benlo, Schneider, C&S. | — | — | — | 14,337.92 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing & commissioning of 2 way sheet steel DB with 2 Nos. S/P MCB of 16 A cap. complete with Bas bar, Neutral bar, Din rail etc. on wooden/metal bd. Incl. connection & earthing MCB make Siemens/Ligrand/Standard/GEC/Havells/ HPL/ Anchor. | — | — | — | 2,308.24 | |
| — | 80.00 | — | — | ||
| Supply & delivery of OREVA 40 W 4000 K LED Tube light Brand: OREVA Brand type : registered Brand Catalogue Status : Catalogue not verified by OEM Seling As : Reseller not verified by OEM Category Name & Quadrant : Light emitting diode LED fixture- LED tube light (Q3) Model: silver-40W (4Ft) HSN Code: HSN not specified by seller. Make:-Havells, C&S, Bajaj, Oreva or similar. Warranty 05 Years from the date of installation. | — | — | — | 59,552 | |
| — | 12.00 | — | — | ||
| Supply, fixing, connection, testing and commissioning of LED fitting indoor type System wattage 20 W, IP 65 or better, deriving its name from the Nothern lights that make the sky look magnificent, Auora plus lights up your home with utmost glamour it deserves.3-in-1 color modes make it even more versatile. LED used in fittings should be of Make: NICHIA/ OSRAM/SEOUL/CREE/ PHILIPS LUMILEDS/ LEDNIUM with warranty period of 5 Yrs from date of commissioning or 6 Yrs from date of supply whichever is earlier complete with fixing arrangement. (dressing , mirror etc. light)Make: Philips, Bajaj, Havells, Syska. | — | — | — | 12,960 | |
| — | 92.00 | — | — | ||
| Fixing & commissioning of LED light fitting with tube. | — | — | — | 2,368.08 | |
| — | 36.00 | — | — | ||
| Fixing of ceiling fan. | — | — | — | 1,548 | |
| — | 16.00 | — | — | ||
| Installation, testing, fixing & commissioning of exhaust fan 300/380/450mm sweep in the existing opening including making the hole to suitable size for above fan, making good the damage with cement concrete including connection earthing the body complete etc. as required. | — | — | — | 2,516 | |
| — | 4.00 | — | — | ||
| HIKVISION Analog Video Door Phone/Bell with 7" TFT LCD Screen Wired 1080p Resolution | Builtin Mic & Loudspeaker Noise Echo Cancellation Record. ISI make Warranty 5 year. | — | — | — | 18,396 | |
| — | 20.00 | — | — | ||
| Supply, delivery & Fixing of octagonal pole hot Dip Galvanized in single dip average 70 micron DFT, designed for maximum wind speed of 169KM/Hr.,BOP-7030 type pole of 6 m long, top dia. 70mm, bottom dia. 130mm sheet thickness 3mm, in single section with Base plate (220x220x12)mm (LxBxT) with 4x20mm dia. 700mm long with 100mm projection foundation bolt complete with smart pack junction box with bakelite sheet, 6A MCB & stud terminals (for mounting inside base component of pole) and internal wiring for terminal to fitting with 2x2.5 sq.mm cable including single arm 1 mtr. long suitable for 3 to 10 mtr. pole of reputed make. Make - Bajaj, Transrail, Bansal, Jindal, Gammon Group. | — | — | — | 2,31,054.6 | |
| — | 20.00 | — | — | ||
| Making of foundation suitable for 3 to 8 mtrs. octagonal pole as per site in- charge/4'X4'X4'manufacturer dimension & as per site requirement. | — | — | — | 87,000 | |
| — | 20.00 | — | — | ||
| Supply, delivery & installation of (outdoor) 90 W LED street light luminaire made of pressure die cast aluminum housing LED street light luminaires with IP66, Make of luminaire & Tube- Philips, Surya, Bajaj, Crompton Greaves. Warranty/Guarantee 05 Years from date of installation. | — | — | — | 1,38,750 | |
| — | 900.00 | — | — | ||
| Supply of PVC insulated & sheathed arm. Al. conductor 1.1kV grade LT cable of size 4 x 25 sq.mm. | — | — | — | 1,66,500 | |
| — | 837.00 | — | — | ||
| Supply of PVC insulated & sheathed arm. Al. conductor 1.1kV grade LT cable of size 4 x 50 sq.mm. | — | — | — | 2,08,413 | |
| — | 500.00 | — | — | ||
| Supply of PVC insulated & sheathed arm. Al. conductor 1.1kV grade LT cable of size 4 x 70 sq.mm. | — | — | — | 1,54,000 | |
| — | 2000.00 | — | — | ||
| Laying of LT cable direct in ground of size 25-120 sq.mm complete. | — | — | — | 2,11,020 | |
| — | 1.00 | — | — | ||
| Supply, Fixing, Testing and commissioning of LT cubical panel board of size 135x195x45 cm and thickness 2mm comprising of following 1) 4 pole 400 Amp capacity 415 volt AC MCCB-01 no. for Incoming make ABB GE Siemens, L&T, Hevells, Standard, 2) 4 pole 100 Amp capacity 415 volt AC MCCB-03 nos for outgoing maks: ABB, GE, Siemens, LAT, Hevells, Standard, complete in all respect 3) voltmeter (0-500 volt) with selector switch Ammeter range 0-200 Amp grade with selector switch make Kaycee, AE with CT 400/5 of make KAPPA and copper busbar 400 Amp of require size as per panel size of 3 phase and neutral with other accessories complete in all respect. | — | — | — | 60,125 | |
| — | 8.00 | — | — | ||
| Installation, connection, testing and commissioning of one no. Double pole, Rating - 16-25 Amp. ELCB/RCCB on Concealed suitable size PVC board having top cover hylem sheet (thickness not less than 3mm) including supply of ELCB/RCCB, PVC board, hylem sheet, PVC cover cable (not less than 10 sq.mm) for connection with required material for installation and connection as per instruction of site in-charge. Board make - Cany or similar approved by Sr.DEE/SEE, ELCB make - Havells, HPL, Legrand, L&T, Anchor. | — | — | — | 23,976 | |
| — | 4.00 | — | — | ||
| Supply installation, testing and commissioning of single phase Smart Prepaid meter System:- 240 volts AC 1 phase 2 wire, (IS: 13779 IS:16444,IS 15884 & IS:15959 Part 1 & Part 2 with latest amendments), Marked 10-60 Amps calibration LED and load controlling eature & provisions for TOD (Time of Day) Tariff and R.T.C (Real Time Clock) in a suitable tamper proof hinge type box with ABC reading through mobile app with provision of recharging through vending station, provided Android/IOS/Windows mobile apps should have provision of payment gateway. The communication module (cellular based) with NB IoTGPRS/4G enabled SIM card fallback to 2G modern Optical Port for local communication/WAN(Cellular) communication for Data acquisition. All Smart Prepaid meters should be provided with integrated cloud system. Implementation of cloud hosted head end and meter end data management including mobile network system. Meter should have connect/disconnect prepaid billing software. The meter should work either in prepaid and post paid mode. The meter shall have suitable provision to consumer recharge locally in case of no WAN/ communication scenario and monitoring consumption information through mobile app. Warranty of meter should be 05 years from date of commissioning. Meter should emboss with property of E.C. Railway. Released materials should be dismantled and deposited to the consignee. The rates are inclusive of SIM and data charges for a period of first 5 years with all necessary accessories. | — | — | — | 30,705.36 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
I_CT_GCC-
ATTACHMENT
GCCACS1-9.pdf
ATTACHMENT
Advancecorrectionslipno.10.pdf Advance correction slip no 10
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
Tender document
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
Advancecorrectionslipno.10.pdf
ATTACHMENT
Tenderdocument04unittype-VIQtr.atSEE.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .