| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹57.9 L+₹1.5 L (2.69%)Rejected-AOC C O BARENDRA NARZARI SARUBENGERA P O KABIRALI P S UDALGURI DIST UDALGURI BTC ASSAM | UDALGURI | UDALGURI | ASSAM | 784509 | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Failed |
Tender Value
₹56.5 L
EMD Value
₹1.1 L
Closing Date
14 Feb 2022, 1:00 pmClosed
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD BTC, Kokrajhar
Repair and Renovation of Amgagaon Bodo Medium High School in Udalguri District for the financial year 2021-22.
2022_BTC_24207_1
ACE-35/TECH/UDL(RB)/IFB/18-19
Open Tender
Civil Works
Works
120 days
Udalguri Dist.
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,700
Principal Secretary, BTC, Kokrajhar
₹1.1 L
Yes
5 Mar 2022
3 Feb 2022
14 Feb 2022
3 Feb 2022
14 Feb 2022
3 Feb 2022
3 Feb 2022 - 14 Feb 2022
Amount
A) Civil Works:- 23.12:- Dismantling of all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels.
23.9:- Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
23.15:- Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
23.14:- Demolishing the plastering from wall/RCC and PCC members without causing any damage to the wall/member upto any height including disposal of debris as directed for all levels.
18.3.2:- Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or combination of following sections of (i) Square section (ii) Rectangular Hollow section of specification SHS/RHS and including purlins bottom runners and ….
8.1.35:- Providing Pre Painted Galvalume Sheet Roofing (P.P.GL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlin etc. to be measured and paid separately) TATA Blue Scope/Dyna roof/ Woder Roof or equivalent as directed by the department. (iv) 0.60mm thick.
18.1.36:- Providing Pre Painted Galvalume Sheet (PPGL) accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete Tata Blue scope/Dyna roof/Wonder Roof or equivalent as directed by the department. vi) 0.60mm
7.10.1:- Providing and fixing in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mm x 600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm. Using 4mm/6mm thich high..... A) Standard Ceilings of Everest make or equivalent as directed by the department. ii) Using 6mm thick FC Board
5.1.14:- 65mm thick cement concrete floor consisting of 50mm under layer of cement concrete in prop. 1:3:6 (1 cement : 3 coarse sand : coarse aggregate of 25mm and down) and 15mm thick wearing layer in cement concrete in prop. 1:1:2….. Complete as directed. (ii) 6mm thick F/C. Board
18.7.2:- Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and stee; base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 PCC after fitting the frame with brick/concrete works etc. coomplete as directed by the department for all levels (PCC to be measured and paid separately) iii) Size 125mm x 60mm (Single rebate)
18.7.2:- Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and stee; base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 PCC after fitting the frame with brick/concrete works etc. coomplete as directed by the department for all levels (PCC to be measured and paid separately) b) 1.60mm thick sheet iii) Size 125 x 60mm (Single rebate)
9.12.1: Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevant I.S. code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws a) Decorative type face panes and lock board core. i) 40 mm thick
18.5.3:- Providing and fixing steel windows of standard rolled steel section as per relevant I.S. code, joints mitred and welded with 15mm x 13mm x 100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device, steel handles, pegs, stays of 300mm long etc. complete including providing 12mm x 12mm sq. bars duly welded to steel frame at more than 12xm c/c applying a priming coat of red-lead paint etc. complete as per drawing. a) Openable
18.5.4:- Providing, fitting and fixing steel ventilator (openable) of standard rolled steel section as per relevant I.S. code, joints mitred and welded with 15mm x13mm x 100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device, steel handles, pegs, stays of 300mm long etc. complete including providing 12mm x 12mm sq.bars (horizontal) duly welded to steel frame applying a priming coat of red oxide paint etc. complete as per drawing.
16.1:- Providing and fixing clear sheet glass bedded in putty and fixed with/without wooden bidding including necessary cutting and glass to be required sized (Payment for wooden bead shall be made separately) (1) Area of glass panes not exceeding 0.15m2 (a) 3.00mm thick
15.2.1:- Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects….etc. complete as directed. (b) Tower bolt (ii) 250mm x 12mm
15.2.1:- Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects….etc. complete as directed. (b) Tower bolt (iii) 200mm x 12mm
15.2.1:- Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects….etc. complete as directed. (c) Door handle (ii) 150mm
15.2.1:- Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects….etc. complete as directed. (d) Gate shutter hook & eye (ii) 150mm
19.2:- Providing plinth protection with brick flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with floating coat of neat cement finish.
19.5:- Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
B) SANITARY WORKS: 1.2:- Providing, fitting and fixing vitrous China pedestal type water closet…required (European type WC pan 400mm height with seat and lead, CP brass hinges and rubber gasket) (a) Parry ware make i) Universal closet S Trap (Cat No.10271) (Anglo India)
1.8:- Providing, fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and C.P. brass speader and brass union etc. a) Parryware make a) White i) New (Cat. No.C0575)
1.9:- Providing, fitting and fixing vitreous china squating plate urinal with automatic flushing cister with standard flush pipe and CP brass speader and brass union etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware Make i) White (Cat. No.C0503)
1.13.1:- PEDESTAL BASIN (With Pedestal) A) Parryware make i) Duke 660 x 495 (Cat. No.C8416/27) White Coloured
1.19:- Providing, fitting and fixing Decorative Mirror complete as directed and specified A) Parryware make a) Size 800mm x 600mm
1.37.1:- Supplying, fitting and fixing PVC pipe 6 kg/cm2 (Supreme/Prince) or other ISI approved brand including joining, fitting and fixing with clamp, etc. as necessary complete. (a) In exposed surfaces or in trenches (iv) 160mm dia
1.37.2:- Supplying, fitting and fixing 87.5 degree PVC bend (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamp etc. as necessary complete below G.L. as specified and directed. (a) In exposed surfaces or in trenches (i) 160mm dia
1.37.2:- Supplying, fitting and fixing 87.5 degree PVC bend (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamp etc. as necessary complete below G.L. as specified and directed. (a) In exposed surfaces or in trenches (iv) 75mm dia
1.38:- Providing, fitting and fixing 50mm dia. HCI cowel with cement…. Complete as directed and specified.
1.46:- Providing, fitting and fixing 450mm dia 90mm thick man hole cover and frame of 58 Kg weight complete as directed and specified.
1.51:- Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats covered with plain sheet above brick bats filling etc. complete.
1.52:- Constn. Of inspection pit inside measurement 450mm x 450mm x 450mm flush with 100mm dia meter HCL/PVC pipes and cement concrete base in prop. 1:3:6 over flat brick soling, 12 cm brick wall etc. complete as directed.
2.1.1:- Clearance of service septic tank and removing the might soil and debris etc….complete. b) 100 Users
Construction of Main Entry Gate:-:- 1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soi
1.3:- Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
1.4:- Raising low site including around the building with approved soil obtained from outside by truck carriage within initial lead of 8.00 km including breaking clods, dressing etc. complete including paying necessary land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned). (b) Other than Guwahati city
18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
17.11:- Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts)
2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand :6 coarse aggregate by volume
2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
3.1.1:- Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1:- Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (i) Using 38mm thick plank
3.1.1.2:- Sides of tie beams, grade beams etc. at or below ground level. (i) Using 38mm thick plank
3.1.1.3:- Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (i) Using 38mm thick plank
3.1.1.4:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M (i) Using 38mm thick plank
3.1.1.5:- Flat Surfaces such as soffits of suspended floors, roofs, edges of slab, landings, cantilever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (i) Using 38mm thick plank
3.1.1.11:- Arches/ slabs having curved surface in one direction. (Using 38mm thick plank)
26.1.2:- Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
4.1.1:- Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
5.1.4:- 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed
6.2.1:- 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
6.2.3:- 20 mm thick cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and/ or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15mm and finishing coat 5mm thick) b) In cement mortar 1:4
13.7.2:- Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers dnd sand paper a) With ready mixed "red-lead/red oxide" primer.
13.7.4:- Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. b) High gloss (Asian paint/ Berger paint/ ICI paint/ J&N paint/Nerolac).
13.3.1:- Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
13.3.4:- Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceilings both internal and external) after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii) Thickness=1.0mm thick
13.2.3:- Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.4.1:- Wall painting (two coats) with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Nerolac)
RCC Stagging with Filteration Unit and Installation of DTW & WS works:- 1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soi
4.1.1:- Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand :6 coarse aggregate by volume
18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
3.2.1:- Providing form work of 12 mm thick Plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. 3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0 M.
3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face a) Square, rectangular……..
3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. a) Square, rectangular……..
3.2.1.3:- Flat Surfaces such as soffits of suspended floors, edges of slab, roofs, landings, cantilever slabs, chajjas, balconies and the like. a) Floors etc. upto 200 mm in thickness
2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (I) Using Mixture Machine (A) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M15 grade concrete or Prop. 1:2:4
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M15 grade concrete or Prop. 1:2:4
4.1.6:- Brick work in cement morter with 1st class brick including raking out joints and curing complete as directed. ii) In super structure above plinth level upto 1st floor level b) In prop. 1:5
4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete…… etc. a) In cement mortar in prop. 1:5 A) 112mm thick brick wall
6.2.2.:- 15mm thick cement plaster in single coat on rough side for interior plastering upto 1st floor level including ariges etc. a) On fair side b) In cement mortar 1:4
10.2:- Providing fitting and fixing MS Grill of required pattern for windows/ clerestory windows/ opening with M.S. flats of required spacing b) Plain Grill c) Fixed to brick work/PCC/RCC
13.2.1:- a) Colour washing with lime on wall surface (Two coats) over and including a priming coat of white washing to give an even shade after thoroughly brooming the surface to remove all dirt….
Deep Tube Well: 5.3.4:- Labour for boring hole for inserting tubewell through different soil/rock media including hire charge of drill pipes etc. ii) Bore hole of 100mm dia meter
5.3.5:- Supplying fitting and fixing pipe (Plain/Bevel ended) for casing conforming to solvent IS code of practice including supplying and…….. i) GI Pipe a) TATA/SAIL (Medium) Sockets should be welded to the pipes iii) 80mm dia meter.
5.3.6:- Supplying fitting and fixing section pipes (Plain/Bevel) conforming to relevant IS code of practice……. A) G.I. Pipe a) TATA/SAIL (Medium) Sockets should be welden to the pipes ii) 32mm dia meter
5.3.7:- Supplying, fitting and fixing G.I. filter and fixing G.I. filter 2.00m long
5.3.12:- Development of the Tube well compressor or by over pumping unit for 48 hours/ till sand free discharge is obtained.
5.3.13:- Flushing, clearing, washing and watering of the tube well
5.1.1:- Supplying fitting and fixing 1st class ITC or similar approved GI pipe etc. complete. A) G.I. pipe with GI fittings a) Using TATA/ SAIL (Medium) v) 32mm dia
5.1.1:- Supplying fitting and fixing 1st class ITC or similar approved GI pipe etc. complete. A) G.I. pipe with GI fittings a) Using TATA/ SAIL (Medium) v) 40mm dia
5.1.1:- Supplying fitting and fixing 1st class ITC or similar approved GI pipe etc. complete. A) G.I. pipe with GI fittings a) Using TATA/ SAIL (Medium) iii) 25mm dia
5.1.1:- Supplying fitting and fixing 1st class ITC or similar approved GI pipe etc. complete. A) G.I. pipe with GI fittings a) Using TATA/ SAIL (Medium) ii) 25mm dia
3.17.1:- Supplying fitting and fixing country pit valve (full way valve) ISI make as specified and directed. b) 40mm dia
3.17.4:- Supplying fitting and fixing G.I. Foot Valve with strainer including cutting necessary thread to pipe………. b) 40mm dia (Heavy type)
5.4.2:- Supplying fitting and placing in position plastic cylindrical vertical closed top (PCVC) Tank of Sintex/Polycone/Pattan tank……complete. I) 2000 Litre Capacity a) Sintex make
Supplying fitting and fixing Motor Pump set with all accessories
Construction of Latrine & Urinal:- 1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soi
4.1.1:- Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand :6 coarse aggregate by volume
18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. b) Other ISI approved TMT reinforcement bar.......
18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. C) ISI approved M.S. rod
3.2.1:- Providing form work of 12 mm thick Plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. 3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0 M.
2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (I) Using Mixture Machine (A) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M15 grade concrete or Prop. 1:2:4
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M15 grade concrete or Prop. 1:2:4
4.1.4:- Brick work in cement morter with 1st class brick including raking out joints and curing complete as directed. i) In substructure upto plinth level including dewatering if necessary b) In prop. 1:4
1.3: Earth/ sand filling in plinth layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly not plastic) by truck carriage including loading and unloading.
18.7.2:- Providing, fitting and fixing powder coated pressed steel door frame made of 1.20mm/1.60mm thick sheet of various sizes with necessary hinge jamb, lock jamb, read and steel base ties at the bottom of the frame the whole frame shall be welded or rigidly.........etc. (a) 1.25mm thick sheet. (iii) Size 125mm x 60mm (Single rebate)
4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete…… etc. a) In cement mortar in prop. 1:5 A) 112mm thick brick wall
9.12.1:- Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels…etc. complete. (i) Decorative type face panel and block board core. ii) 35mm thick
18.3.2:- Providing, fitting, hoisting and fixing of roof trusses fabricated using any one of combination of following sections of (i) Square section…..
6.2.2:- 15 mm thick cement plaster in single coat on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and/ or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4 A) On Rough Side
B) On Fair Side
8.1.1.:- Providing corrugated galvenised iron sheet roofing of TATA SHAKTEE/ SAIL including fitting and fixing necessary galvanized J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick….purlin etc. (c) 0.63mm thick
5.1.4:- 65mm thick cement concrete floor consisting of 50mm under layer of cement concrete in prop. 1:3:6 (1cement: 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15mm thick wearing layer in cement concrete in prop. 1:1:2… complete as directed.
13.2.2 (c) : Applying one coat of distemper primer of approved brand and manufacture on wall surface after thoroughly brushing etc.
13.2.2 (f) : Distempering with dry distemper of approved brand and manufacture (two coats)… etc. complete.
13.2.3: (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and includig preparing the surface eevn and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and required shade on new wall surface (two coats) to give an even shade after thoroughly….powdered materials.
5.7.1.2:- Providing polished ceramic tile of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 including cutting …etc. (i) Executive range Somany/Orient/Nitco/Asian Make i) of size 300mm x 450mm and above.
5.7.1.1:- Providing polished ceramic tile of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 including cutting …etc. (i) Executive range Somany/Orient/Nitco/Asian Make i) of size 600mm x 600mm and above.
9.4.1: Providing barge board of size 200mm x 25mm with 1st class local wood Hollock/Bonsum/Sundi etc..complete as directed.
1.1:- Providing fitting and fixing vitreous water closet squatting pan (Indian Type Orissa Pattern) of size 550mm x 4.20mm a) White 1) Parryware make
1.37.1:- Supplying, fitting and fixing PVC pipe of 6 kg/cm2 (Supreme/Prince) of other ISI approved etc…complete. a) Exposed surfaces on in trenches ii) 110mm dia.
1.37.1:- Supplying, fitting and fixing PVC pipe of 6 kg/cm2 (Supreme/Prince) of other ISI approved etc…complete. a) Exposed surfaces on in trenches ii) 75mm dia.
1.37.2:- Supplying fitting and fixing 87.5 degree PVC bend (Supreme/Prince) of other ISI approved…etc. a) Exposed Surfaces on in trenches ii) 110mm dia
1.30.1:- Construction of filter bed in soakpit of…etc. comoplete
1.30.2:- Constn. of inspection pit inside measurement 450mm x 450mm x 450mm lear top..etc complete.
1.39:- Providing fitting and fixing 75mm dia PVC Cowel of ISI marked approved …etc. complete. Iv) 75mm PVC cowel of ISI make
6.2.1:- Supplying and placing ferrocement septic tank of rectangular (vii) 50 Users.
1.4:- Raising low site including around the building with approved soil obtained from outside by truck carriage within initial lead of 8.00 km including breaking clods, dressing etc. complete including paying necessary land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned). (b) Other than Guwahati city
Sri Mukul Narzari
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .