Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | As L1₹11.7 LAccepted-AOC GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | As L1 | Accepted-AOC L1 |
Tender Value
₹13.4 L
EMD Value
₹26,765
Closing Date
7 Oct 2017, 9:00 amClosed
Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
Repairing of One no Electrical Installation works at newly constructed guest room in VYBK Salt Lake Kolkata 98 SITC of fire detection system
2017_WBPWD_129735_1
WBPWD/EE/BED/25/e-IT of 2017_18/4th Call
Open Tender
ELECTRICAL WORKS M/R
Item Rate
40 days
VYBK
Please refer Tender documents.
4 documents required · 4 mandatory
₹26,765
Yes
30 Sept 2021
18 Sept 2017
9 Oct 2017
19 Sept 2017
7 Oct 2017
19 Sept 2017
Amount
Supply, Installation Testing & Commisioning of EN-54 standard VDS/LPCB. Approved Microprocessor based 4 Loops expandable up to minimum 6 Loops, fire alam control panel fully networkable with each loop capable of taking atlest 125 devices and each loop should be connected to a dedicated loop card (even if a loop card supports multiple loop the panel should be provided with 4 nos loop cards and should have provision for accomodating total 6 nos loop card). 1/4 VGA display character alpha-numeric liquid crystal display. The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Futher, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier provision for external & internal printer (if required) Loop cards. LCD unit to indicate Fire/Fault Signal with address and anaog output, complete in all respects having minimum 1000 event memory, integral SMF lead acid batteries with sealed cells of 24 V/12 V with integral battery charger complete as required and as per specification. (Approved Make : Honeywell/Bosch/Secutron/Siemens)
Supply, installation, testing & commissioning of EN-54 Standard, VDS/LPCB approved Addressable Multi-Sensor Detector (optical smoke as well as heat) with inbuilt/additional Isolator and intergral LED status indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required with the protection category of IP40 (Approved Make: Honeywell/Bosch/Secutron/Siemens)
Supply, installation, testing & commissioning of EN-54 Standard, VDS and FM approved Intelligent Addressable Air duct smoke detector with inbuilt short circuit Isolator capable of detecting in ducts up to 2.8m, usable in air speeds from 1 to 20m/s and should have the protection of IP54. (Approved Make: Honeywell/Bosch/Secutron/Siemens)
Supply, installation, Testing & Commissioning of Response Indicator, with all other accessories. (Approved Make: Honeywell/Bosch/Secutron/Siemens)
Supply, installation, testing & commissioning of EN-54 Standard, VDS/LPCB approved Intelligent addressable manual call point with inbuilt/additional Isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra accessories as required. (Approved Make: Honeywell/Bosch/Secutron/Siemens)
Supply, installation, testing & commissioning of EN-54 Standard, VDS/LPCB approved addressable One input & One output module with inbuilt/additional isolator and shall have the LED indication for Normal, Fault, test and activation. The module shall have the option for configuration as fail safe operation. (Approved Make: Honeywell/Bosch/Secutorn/Siemens)
Supply & Drawing of 2 core 1.5 sq. mm FRLS shielded copper Cable. (Make : Finolex/Technoflex/MEM/KEI)
Supply & Laying of 20 mm FR PVC rigid condult pipe on the surface of the wall (Make : Precisson/Prestoplast Medium)
Comprehensive Maintenance (with spares to be supplied free of cost by the bidder) of the system for another year after expiry of 1 year defect libility period of the Bidder from the date of commissioning of the system (Rate should be qouted considering minium wages act.)
L.W.C. must be quoted manually @1% on the total quoted value else the LWC shall be treated as included in quoted value.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .