Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 10 SUBASH COLONY DEFENCE LAB ROAD RATANDA JODHPUR 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | Admitted-Finance |
| 5 | Admitted-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
14 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER ARMY UTILITY JODHPUR
GARRISON ENGINEER ARMY UTILITY MULTAN LINE JODHPUR
REPAIR / MAINT OF STREET AND SECURITY LIGHT AND OTHER ALLIED WORK AT SECTOR C AND D AREA IN ARMY AREA JODHPUR
2021_MES_456111_1
8985/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER ARMY UTILITY MULTAN LINE JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER ARMY UTILITY JODHPUR
₹20,000
Yes
24 Aug 2021
1 Jul 2021
21 Aug 2021
1 Jul 2021
14 Aug 2021
15 Jul 2021
60 days
Amount
Repair and refixing to street lights of any type by removing from existing position and refixing after repair including replacement of the following items complete all as specified and directed by EIC. (a) Electronic Driver suitable for 25/36/40/45/50/72/90/120 Watt LED light fittings (b) Surge Protector not less than 5 KV rating suitable for 25/30/35/36/45/50/72/90/120 Watt LED light fittings. (c) PCB suitable for LED street light fittings 25/30/35/36/45/50/72/90 Watt. Note : (i) Items mentioned at (a) to (c) above to be incorporated in the work will be measured and paid separately under respective item supply only items. (ii) Certain spare components shall be issued under Sch 'B' (iii) T&P / Vehicle mounted Telescopic Ladder required for carry out the repair work on lights at a height up to 15 meter will be issued to contractor under Schedule 'C' as demanded by contractor.
Repair and refixing of High mast lights fitting of any type by removing from existing position and refixing after repair including the replacement of following items complete all as specified and directed by EIC. (a) Electronic Driver 100/150/200 Watt suitable for LED light fitting of rating. (b) Surge Protector not less than 5 KV rating suitable for100/150/200 Watt LED light fittings. (c) PCB suitable for LED flood light fittings 100/150/200 Watt Note : (i) Items mentioned at (a) to (c) above to be incorporated in the work will be measured and paid seperately under respective item supply only items. (ii) T&P / Vehicle mounted Telescopic Ladder required for carry out the repair work on lights at a height up to 15 meter will be issued to contractor under Schedule 'C' as demanded by contractor.
Labour only for making unserviceable street/security lights serviceable placed at pole by disconnecting / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire all as required and as directed by Engr-in-Charge. Note : - (a) New cable as required shall be measured and paid separately under respective item under supply only item. (b) In case major components like surge protector, driver, PCB are requried to make the unserviceable light serviceable, the item of repair shall be measured under item ser No 1 & 2 above.
Dismantling of depreciated cross arms (Clamp, nut bolts )/ channels/ supports etc care fully from site all as specified and directed by Engr-in-charge.
Material and labour for steel structure, cross arms bracing supports ,clamps, back plates of any type, section incl. nuts, bolts, washers, welding ,bending cold or hot in any size and shape all as directed Including two coats of aluminium paints over a coat of red oxide primer including preparation of surface all as directed by Engr-in-charge.
Restringing/refixing only of ACSR conductor of street / security light feeder including straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc all as directed by Engr-in-charge complete of any size. Note : - Single conductor shall be measured for length re-stringing.
Material and Labour for GI tubing medium grade in repairs including accessories for protection of cables on poles / under road crossing of following sizes :- (a) 40 mm dia
(b) 50 mm dia
Laying only in trenches in replacement of unserviceable cable/ LT OH line, LT under ground cable XLPE insulated PVC sheathed 1100 V grade armoured heavy duty aluminium conductor including testing commissioning of the following cross sectional area ranging for 6 sqmm to 35 sqmm, 2/3.5/4 core. Note : (i) LT XLPE cable will be issued by department free for fixing under Sch 'B'. (ii) Earth work, cable protection, sand shall be measured and paid separately.
Dismantling of broken U/S existing earthing with galvanised steel strip 32x6mm and 10/8 SWG wire complete including removing of PCC from site.
Earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. Note : Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I.
Motorized Augering/driling under road of suitable dia for laying of 40/50 mm dia GI tubing pipe all as directed by Engineer-in-Charge.
Material and labour for Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of pole /struts/stay assembly etc including any form work required complete all as directed by EIC.
Material and labour Cement concrete (1:2:4) type B -1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work ,fair finishing to exposed surfaces using extra cement complete all as directed by EIC.
Excavation in trenches not exceeding 1.5m wide and n.exc. 1.5m in depth for laying of cable and foundation in soft/loose soil complete all as specified and as directed by EIC.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and getting out in soft/loose soil.
Returning filling in and well ramming in layers n. exc. 25cm thick including spreading, leveling and watering all as specified and directed by EIC.
Removing excavated material (soil/rock) and depositing at a distance not exceeding 50m where directed.
M&L for sand cushioning to U/G cable for cushioning 8cm below the cable and 15cm above cable all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm for protection and laid perpendicular over the cable all as specified and as directed by Engr-in-Charge.
Fixing only street light/security light/flood light fitting LED type of any watt and any size suitable for mounting on 40 mm dia FI mast or bracket arms with pole fixing attachments and proper fixing/connecting of service cable from pole box to street light fitting including dismantling of old existing light fitting and depositing to MES store yard complete all as specified and directed by Engr-in-Charge. Note : LED street /flood / security light fitting of any type will be issued by department free for fixing under Sch 'B'.
Fixing only LED driver of any type street light/security light/flood light fitting LED type of any watt and any size with suitable nut, bolts, screws and proper fixing/connecting of driver to PCB and surge protectors including dismantling of old drivers complete all as specified and directed by Engr-in-Charge. Note : LED drivers of any type will be issued by department free for fixing under Sch 'B'.
Fixing only LED PCB of any type street light/security light/flood light fitting LED type of any watt and any size with suitable nut, bolts, screws and proper fixing/connecting of driver to PCB with proper soldering and including dismantling of old PCB complete all as specified and directed by Engr-in-Charge. Note : LED PCB's of any type will be issued by department free for fixing under Sch 'B'.
S&F MCB single pole 'B' curve, 230 Volts 10 KA upto 4 Amp rating complete all as directed by Engr-in-Charge. Make : L&T / Legrand / ABB
Supply and fix electric contactor three phase, 415 Volts, 50 Hz, upto 50 Amp load capacity suitable for street light timer box complete all as specified and directed by Engr-in-Charge. Make- ABB / Siemens /BCH / C&S Electric / Legrand
Supply and fix electric contactor single phase, 230 Volt, 50 Hz, upto 40 Amps load capacity suitable for street light timer box complete all as specified and directed by Engr-in-Charge. Make- ABB / Siemens /BCH / C&S Electric / Legrand
Supply only Electronic Driver Input Voltage Range 160V to 260V AC Single Phase 50 Hz and Output Voltage not exceeding 60V DC suitable for 21/25/30 Watt LED type fitting complete all as per Make-Philips/Wipro/Crompton/C&S Electric.
All as per item No. 26.00 but suitable for 36/40 Watt LED type light fitting.
All as per item No. 26.00 but suitable for 45/50 Watt LED type light fitting.
All as per item No. 26.00 but suitable for 72/75 Watt LED type light fitting.
All as per item No. 26.00 but suitable for 100 Watt LED type light fitting.
All as per item No. 26.00 but suitable for 150 Watt LED type light fitting.
Supply only surge Protector not less then 5kV suitable for 25/30/35/36/45/50/72/75/100/150 Watt LED type light fittings complete all as per direction by Engr-in-Charge. Make : -Philips/ Wipro/ Crompton/ C&S Electric.
M & L for painting to steel tubular pole/rail pole upto 9 mtr long with two coats of aluminium paints including preparation of surfaces and painting of pole coping with white synthetic enamel paint and writing pole No. etc all as directed by Engr-in-Charge. Note : - Zebra painting the bottom of pole is deemed to be included in the quoted rate.
M & L for disconnecting and re-connecting of burnt LT XLPE cable to OH conductor on pole/ equipment including removing of faulty part of cable, preparation of cable for connection, suitable Aluminium lugs, nut bolts etc and as directed on site by EIC. Note: The cost of earth work for taking out LT cable loop and refilling will deemed to be included in the quoted rate of this item.
Material and Labour for ZEBRA painting of PCC/steel poles 9/11 m long alongwith road upto 1.5 m height from pedestal, with two coats of synthetic enamel paint in 30 cm height incl painting of pole coping with white paint and writing pole No. etc all as directed by EIC.
M&L for trimming and pruning of one complete tree up to a safe distance from the over head lines incl cutting branches of size not exceeding 80mm dia complete all as directed at site and disposal of branches/bushes to a distance and clearing the site all as directed by Engineer-in-charge NOTE:- 1. The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to incl in the rate quoted for the job. 2. Proper shut down will be taken by the authorised rep only. 3. One Job will be considered for trimming/ prunning of one complete tree branches of given size.
Supply and fixing as in replacement of burnt / unserviceable timer switch astronomical time watch digital type along with switch for (auto/manual) on and off including MCB as per requirement complete all as specified and directed by EIC Make: Legrand /Schnieder/L&T/BCH
Supply and fix security light termination box pole junction box of size 250×200×100 mm, weather proof, along with connector for 3 phases and neutral and MCB SP - 0.5 / 2 Amps rating incl Power Terminals 16sq.mm - 6 No. The Junction Box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. Degree of Ingress Protection IP 65, Pole Mounting type, including M32 Cable glands for 10/16sq.mm x 2/3.5/4.0 Core cable I/C & O/g .- 2 Nos with terminals, MCB, Cable Glandsetc complete all as specified and directed by EIC. Make :Sintex/Hensel/Neptune.
S & F Copper cable 1100 volts grade PVC insulated and PVC sheathed weather proof multistranded conductor of size 3 Core x 1.5 sqmm complete all as specified and directed by EIC. Make : Finolex/ Havells/ Polycab / Universal/ Nicco.
M&L as in repair/replacement of PVC conduit 20 mm rigid non metallic including of all tee, bends, elbows etc including fixing accessories GI bracket of suitable size with nut bolts etc complete all as specified and directed by Engr-in-Charge.
Supply and fix GI pipe Bracket of 32 / 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr incl 2 Nos. MS Clamp of flat iron of suitable size complete with nut , bolt, washers Including two coats of aluminium paints over a coat of red oxide primer all as specified and directed at site.
Dismantling of insulators any type any size from existing poles all as directed by Engr-in-Charge.
Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified.
Supply and fix shackle type porcelain vitreous white insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel strap of size 31mm x 3mm , 12 mm dia insulators bolts, washers and nuts complete all as specified.
Supply and fixing of LED post top light with Die cast Aluminum housing in Pure Polyster UV resistant powder coated grey finish, HET PMMA diffuser, IP65 Protection, Maximum system wattage 45 watts, min 3500 system lumens, 3 stage CCCV driver with 4kV surge protection voltage range of 150-270 V AC and connecting complete all as specified and directed at site by Engr-in-Charge Make :- Wipro / Crompton / Philips / C&S Electric.
Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relevant latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping complete all as specified and directed at site. NOTE:- (i) Earthwork, PCC will be measured and paid separately under relevant item of BOQ. (ii) Removal of dismantled items from site are included in rate quoted by the contractor.
M/s Vishaka Enterprises
Shree Karni Construction
M/S SHREE AAINATH ENTERPRISES
CHAHAR ENGINEERS AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .