Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹3.4 L+₹13,579 (4.15%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹3.6 L+₹29,650 (9.06%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹3.7 L+₹42,015 (12.8%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹3.8 L+₹56,680 (17.3%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹4.4 L
EMD Value
₹8,760
Closing Date
9 Oct 2021, 6:00 pmClosed
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA -522 101
AS PER BOQ AND TENDER DOCUMENT
2021_MES_474758_1
AGE(I)/SL/8422
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ARO GUNTUR SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
7 documents required · 7 mandatory
₹300
AGE (I) SURYALANKA
₹8,760
Yes
28 Oct 2021
13 Sept 2021
11 Oct 2021
13 Sept 2021
9 Oct 2021
27 Sept 2021
14 Sept 2021 - 21 Sept 2021
Amount
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS PVC insulated unsheathed cable 1100 volts grade fixed in and including Concealed PVC conduit, fitting and accessories, joints boxes including one 1.5 Sqmm copper FRLS PVC insulated unsheathed earth continuity conductor connected in the common earth, including suitable size metal flush box, modular cover plates, after wall cutting making good with Plaster and painting to match the existing surface including taking down the old wiring complete all as specified and as directed for following:-
One light/fan/5A independent Socket / Bell point controlled by one switch
One 3 pin socket outlet 5 amps on same board controlled by one switch with 1.5 sqmm size cable
One 3 pin socket outlet, 15 amps / AC Metal Clad, controlled by one switch on independent board with 4 sqmm size cable for phase, neutral and earth.
S&F in replacement of Modular Bell push 6A 1 module Switch complete all as specified and as directed.
S&F in replacement of Bell, AC, 230 volts, single pole, complete all as specified and as directed.
S&F in replacement of Modular Switch 5/6 Amps, 1module 1 Way complete all as specified and as directed.
S&F in replacement of Modular Switch 15/16 Amps, 1 Module 1 Way complete all as specified and as directed.
S&F in replacement of Modular Socket 5/6 Amps, 2 Module 2 and 3 pin complete all as specified and as directed.
S&F in replacement of Modular Socket 15/16 Amps, 2 Module 2/3 pin complete all as specified and as directed.
S&F in replacement of Modular Fan Regulator Step type, 2 Module 1 Way, 120 Watt complete all as specified and as directed.
S&F in repair MCB SP 6-32 Amps, C Curve, 10 kA, 230 V Complete all as specified and as directed.
S&F in repair MCB SPN 32 Amps, C Curve, 10 kA, 230 V Complete all as specified and as directed.
S&F in repair MCB SPN 40-63 Amps, C Curve, 10 kA, 230 V Complete all as specified and as directed.c
S&F in repair MCB TPN 16-32 Amps, C Curve, 10 kA, 415 V Complete all as specified and as directed.
S&F in repair 4 Feet LED Tube light of 20Watt integrated Batten LED polycarbonate Tube light with inbuilt driver <10% THD with very high efficiency and connected upto ceiling rose including taking down existing Tube light fitting of any type complete all as specified and as directed.
All as per item No. 13 above But 2 feet 10 watt.
Taking down ceiling fan, cleaning internally & external and removing defective winding and rewinding with new super enameled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans of size 1200/ 1400mm sweep of any make and re-assembling testing complete and refixing to the location including repair of flexible copper wire from ceiling rose to ceiling fan complete all as specified and as directed. Note: The quoted rate shall be inclusive of the transportation charges to and fro between site & work shop etc complete
S&F in repair condenser (capacitor) 3.15/ 2.5 MFD, 230 Volts, AC, 50 Hz as per IS : 1709 suitable for ceiling fan 1200/ 1400mm sweep complete all as specified and as directed.
S&F Heavy Duty exhaust fan of 300 mm sweep (12"), 1400 RPM, 230 Volts, with aluminium louvers and accessories and connecting upto ceiling rose with 3 core 0.5 sqmm copper flexible PVC Cable inclduing taking down the existing fan complete all as specified and as directed.
S&F in repair LED Bldg security light fitting 20 watt 230 volt AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrison resistant inclduing thermal management in multiple optics with IP 65-66 protection, fixed on pole/wall complete all as specified and as directed.
S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed on pole/wall complete all as specified and as directed.
S&F in repair of existing Post light of any type and wattage with New generation, LED Post Top light of wattage 35 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and connecting up with existing cable complete all as specified and as directed.
S&F in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp, fixed on pole/ wall complete all as specified and as directed.
M&L for cleaning of complete indoor/outdoor units of 1.5/2.0 TR Capacity Split Air conditioner by means of adding, cleaning solution (HCL) or equivalent solution with water complete all as specified and as directed. Note:- The cleaning of the condenser and indoor units shall be done using nylon brushers till the scaling is removed completetly
M&L for Top up / Gas charging with refrigerant gas (R-22/32/410) for Air conditioner window type / split type of capacity 1.5 / 2 Ton after vacuuming & leak testing including bracing suction/discharge line and testing complete all as specified and as directed.
S&F in repair Starting Capacitor 35 to 45 MFD
S&F in repair Universal PCB Timer electronic switch with sensor suitable for all makes of split 1.5 / 2 Ton AC complete with hand set including taking down unserviceable Electronic PCB from existing unit complete all as specified and as directed.
M&L in repair/ replacement for Earthing complete with GI Earth Plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with GI earth lead wire of 4.0 mm by means of nuts/bolts/ check nuts/ wahers , GI pipe light grade of 15 mm bore as protection pipe, GI wire of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
S&F in repairs submersible cable PVC insulated & PVC Sheathed, Copper Conductor industrial cable, Flat 3 core 4.0 sqmm 1100 Volt, conforming to IS 694, for submersible pump motors, fixed with clamps complete all as specified and as directed.
S&F in repair 1100 volts grade heavy duty 2 core 6 sqmm cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cable flat or circular complete all as specified and as directed.
All as per Item No. 28 above but with 4 core, 6 sqmm
S&F in replacement of 100 Amps MCCB, 415 Volt, 16 kA, 4 Pole fixed thermal and magnet setting complete all as specified and as directed.
S&F in replacement of common SS Enclosure suitable for 100 Amps, MCCB 4 Pole, 415 V, with interlock and ped lock facility, mounting holes, including installation of RCC/PCC Poles with necessary clamps etc complete all as specified and as directed.
Sai Raja Enterprises
Bismi Engineering
VIJAYA ENTERPRISES
VENKATESWARA ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .