| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.0 L+₹1.0 L (5.84%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹19.4 L+₹1.4 L (7.87%)Rejected-Finance INDEX NO B 33 NC R O KRALPORA DISTT BUDGAM SRINAGAR J K 190019 | SRINAGAR | BUDGAM | JAMMU AND KASHMIR | 190019 | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹20.3 L+₹2.4 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹21.9 L+₹3.9 L (21.9%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
16 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sachin H Chavan IDSE
Garrison Engineer (North) Bathinda Mil Stn
SPL REPAIR TO COOK HOUSE AND PROVN OF WATCH TOWER AT MANDI DABWALI UNDER AGE BR-V AND AGE EM OFFICE OF GE NORTH BATHINDA AT BATHINDA MIL STN
2021_MES_423328_1
8935/NIT-62/20-21
Open Tender
Civil Works
Item Rate
184 days
GE North Bathinda Mil Stn
Class E
9 documents required · 9 mandatory
₹500
GE (North) Bathinda
₹41,000
Yes
23 Mar 2021
18 Feb 2021
18 Mar 2021
18 Feb 2021
16 Mar 2021
4 Mar 2021
18 Feb 2021 - 24 Feb 2021
60 days
Amount
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement including demolition of cement concrete (unreinforced, existing plinth floor, hard standing etc, only damage area of plinth) of any description and in any position, same material using as a hard core, filling in down surface/depressions area which occurs during the process and the surface prepared in leveled well ramming including watering as required and consolidation with Durmat/hand roller, rolling to required gradient and camber and upto entire satisfaction of Engineer-in-charge, balance unused material/dabries removing rubbish from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge. Note :- Extra hard core where required for leveling the surface same shall be measured and paid separately under appropriate item of this schedule.
Material and labour for 50 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping on steps, bed block, cills & similar work etc including necessary form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size bricks (old serviceable bricks obtained from demolition/dismantled item shall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to better rough finished flat complete all as specified & directed by Engineer-in- charge.
Form work to sides of pillars , posts, struts piers, columns and stanchions and similar works rough finished complete all as specified & directed by Engineer-in- charge.
Form work to flat sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas etc and similar works rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed by Engineer-in- charge.
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels, cills, steps; seismic and other similar bands complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Roughening surfaces of old concrete floor by picking and prepare the surface to receive the screed for tiling/kota stone, sweeping cleaning and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor with provision of spacer 3 to 5mm, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular (same as floor tile ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (screed) in cement mortar (1:4) including making good excess taking down plaster area (above skirting tile ) complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 22 mm thick, Kota stone slab (size of slab not less than 550x550mm) as in flooring, laid over and including 15 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 22mm thick, Kota stone slab as in riser of steps, skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing only butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply and fixing factory made 105 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing only butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply only 100mm long powder coated mild steel butt hinges medium weight cold rolled complete all as specified & directed by Engineer-in-charge.
Material and labour for PCC (1:3:6) type C-0, using 12.5 mm graded aggregated as in back filling of chowkhats and for hold fast complete all as specified and as directed by Engineer-in-Charge
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply & fixing aluminium anodised frame, made out of aluminium section weighing 0.98 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron), for doors, windows, ventilators with one or more rebate including jointing cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge. Note :- If aluminium section used other than above mentioned weighing then weight of each section shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site.
Supply & fixing anodised aluminium door shutter, made out of aluminium section weighing 0.55 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron) including aluminium hardware i.e. necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 2 Nos and aluminium hinges 04 Nos in each leaf (size of handle and hinge as directed), anodised aluminium snap beading, screws etc including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply & fixing anodised aluminium window/ventilator shutter side hung type without sash bars, made out of aluminium section weighing 0.55 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 No. for ventilator and 3 Nos for window each shutter) suitable handle (1 No.), including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars (mosquito proof shutter) including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden frame with screw complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel 4 lever mortice lock vertical type 100mm size with original and duplicate key complete all as specified and directed by Engineer-in-Charge.
Supply & fixing aluminium (die cast) body door closer hydraulically regulated, designation No 3, universal type suitable for door shutter of 851 to 1000mm in width and weight between 61 to 80 Kg, ISI marked complete all as specified & directed by Engineer-in-charge.
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply & fixing 3mm thick sheet glass ordinary quality in squares / retangular not exceeding 0.5sqm in each pane (for new door/window) and fixed in any type of doors/windows/ventilators with wooden bead/pin tacked/with oil putty etc. as required or as directed including cutting of glass as per site requirement complete all as specified & directed by Engineer-in- charge.
Supply only 4 mm thick sheet glass ordinary quality in squares / retangular not exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge. Note :- Labour for fixing and fixing material shall be included in the main item of shutters.
Supply only 4 mm thick sheet glass ordinary quality in squares / retangular exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge. Note :- Labour for fixing and fixing material shall be included in the main item of shutters.
Supply & fixing, solar control film 25 micron reflective type (gareware sun control or equivalent) pasting on glass duly air bubble free complete all as specified & directed by Engineer-in- charge.
Supply and fixing in replacement drapery curtain rod 19/20mm dia, fabricated out of mild steel pipe with PVC coating (ABS), wall thickness of pipe not less than 20 guage, including fancy type brackets and pair of decorated end knobs (finials), stop roller etc, fixed to wall for doors and windows cuttings as required and fixing at site complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing drapery curtain rod 19/20mm dia, fabricated out of mild steel pipe with PVC coateing (ABS), wall thickness of pipe not less than 20 guage, including fancy type brackets and pair of decorated end knobs (finials), stop roller etc, fixed to wall for doors and windows cuttings as required and fixing at site complete all as specified and as directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement stainless steel sink with drainage board made out of 1.00mm thick sheet , kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar to dwarf wall or fixing cast iron cantilever brackets and connecting union to waste pipe; overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm including taking down existing chinaware sink complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply only ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets fixed in any position with nails fixed with screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Dismantling plain or corrugated asbestos cement sheet (corrugated / semi corrugated) including ridges as in roof covering complete all as specified & directed by Engineer-in- charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down old any type of truss/purlins in any position or from supported on wall as steel scrap complete all as specified and as directed by engr-in-charge.
Material and labour for mild steel framed work, framed/truss work made by using hollow square/rectangular/round pipe (ERW or induction butt welded tubes conforming to latest relevant IS), or other section like angle, tee, plate, distance pieces, cleats etc. and cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge. Note ;- Sketch of new truss design and steel section to be used shall be approved by Engineer-in-charge in writing before execution)
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for cleaning the roof screed surface including flashing and junction of parapets etc. by brushing, removing all dust and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm complete all as specified and directed by Engineer-in-Charge.
Material and labour for 80mm thick average consolidated thickness mud phuska on flat roofs prepared with wheat straw and cow dung and lay properly including 25mm thick mud plaster and 3 mm thick leeping plaster complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles laid on mud mortar & joints grouted flush and flush pointing in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) and as directed by Engineer-in-Charge. (Note :- Water proofing compound and Mud mortar shall be measured & paid separately under appropriate item of this schedule)
Material and labour for PCC (1:2:4) Type B0 using 12.5mm graded stone aggregate as in roof kerb (golla) or mud stops, side of roof sheet & similar work etc rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including fabrication as directed, including hold fast, locking arrangement, sliding door bolt, stopper etc conforming to Fe-410-W (Gde E-250) quality A, including dismantling /taking down old mild steel framed work of any description not otherwise provided for complete all as specified and as directed by Engineer-in- charge
Material and labour for Framed work such as grills, gratings, cattle trap etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work made out of MS angle, round bars, flat iron, round pipe or other section conforming to Fe.290.Gde-E-165 including welding work including dismantling /taking down old mild steel framed work of any description not otherwise provided for complete all as specified and as directed by Engineer-in- charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying white cement based putty to make the surface even and smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surface of walls / pillars / cornices by brooming down with using broom/sand papering or by any other mean and preparing the surface smooth, applying one coat of exterior emulsion primer as priming coat and after that applying two coats of weather proof exterior emulsion paint (Apex paint / wheather coat, 100% exterier grade), by using paint brush / roller brush as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls / pillars / cornices by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust and washing down with water including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth and also using sander machine (with provision of dust sucking) on uneven surface to make the surface even and smooth (before and after applying putty as per site situation) upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying two coats of cement base paint as per approved tint/colour with using paint brush/roller brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying CBP as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying average 3mm thick layer (1.5mm thick each in two layer application) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge), after applying putty first and second coat sanding the surface as per requirement by using mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer-in-charge and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge. NOTE : - Each stage i.e after complete removal and before applying OBD as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator including rusted/broken concealed conduit, junction and sunken boxes etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick sheet) concealed in wall, including inner and outer plates suitable for fixing the moudular switches, sockets and fan regulator, wiring for light /fan/ bell point controlled by one switch (on indipendent board), including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 100 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 100 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick sheet), including inner and outer plates suitable for fixing the moudular switches, sockets and fan regulator, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), including provn of 2.5 Sqmm FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing modular switch piano type (ISI marked) , 5/6Amps, single pole, one way fixed on inner plate complete all as specified and as directed by Engineer-in-charge. (Inner and outer plate shall be measured and paid in point wiring item of BOQ).
Supply and fixing modular Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 5/6 Amp, flush type fixed on inner plate complete all as specified and as directed by Engineer-in-charge. (Inner and outer plate shall be measured and paid in point wiring item of BOQ).
Supply and fixing modular switch piano type (ISI marked) , 15/16Amps, single pole, one way fixed on inner plate complete all as specified and as directed by Engineer-in-charge. (Inner and outer plate shall be measured and paid in point wiring item of BOQ).
Supply and fixing modular Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 15/16 Amp, flush type fixed on inner plate complete all as specified and as directed by Engineer-in-charge. (Inner and outer plate shall be measured and paid in point wiring item of BOQ).
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 5/6Amps, 250 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 5/6Amps, 250 volts including LED lamp lumeno of 9 watt suitable for B-22 based holder complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4/5), electronic Fan regulator (two module, modular type), 100-120 watt, 250 volts, fixed on inner plate complete all as specified and as directed by Engineer-in-charge. (Inner and outer plate shall be measured and paid in point wiring item of BOQ).
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 4 Way 240V (8+12 modules), double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40 Amps to 63 Amp, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 415 volts AC supply, 63 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCCB of capacity 63 Amp, FP, 415 volt, short circuit breaking capacity not less than 25KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including factory made sheet metal encloser of suitable size made out of CRCA sheet for fixing MCCB, including thimbles, nuts, bolts, washers etc and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .
Supply and fixing in replacement wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as directed complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No BLRB 18W CWc and BLRB-DB 118 of Bajaj / LT8-20-865-2 and DMLN1LT8-16 of Crompton / PHOTONULTRA 1213T8SSTL 18WLED 865 SPC and REGALBATTENT 8UPTO1X22WSSBSWH of Havells
Supply and fixing Sleek Pressure die cast aluminium housing/body, heat resistant clear glass, LED lens for wide beam, energy saving, IP65/66 protection, not less than 5700K, better optics for uniform distribution street/Roadway luminaire with high power LED 25 watt complete fitting with driver, LED strip and all other accessories etc, suitable for 40/32mm OD entry for direct mounting on pipe bracket, fixing on poles/along wall with and including brackets made out of GI tubing light grade 40mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size and including taking down old unserviceable light fitting complete all as specified and as directed by Engineer-in-charge. Make - Cat part No LSTS-25-CDL of Crompton/ BRLEP 25W LED WH of Bajaj / ENDURA PEARL SL25W LED757SASYTOPC of Havells / HLSLD-09-25CWL-R of Halonix
Supply and fixing in replacement recessed LED ceiling tile with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness LEDs 36 W (100 lumens per watt), not less than 5700K including connecting electric connection, including taking down old unserviceable light fittings any type at any site as directed complete all as specified and as directed by Engineer-in-Charge. Make : Cat part No. LCTLRN-36-F0-CDL of Crompton / BZRSQL 36W GZ1 CW of Bajaj / VENUS NEOHE 2X2PLR 18-42WLED857MOD of Havells
Supply and fixing in replacement recessed LED ceiling tile slim panel with wide light window for maximized glare free output suitable for 300x1200mm and ceiling cutout 295x1195mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness LEDs 36 W (100 lumens per watt), not less than 5700K including connecting electric connection, including taking down old unserviceable light fittings any type complete all as specified and directed by Engineer-in-Charge. Make : Cat part No. LCPL-36-CDL (1x4) of Crompton / BZRSLL 36W GZ1 CW of Bajaj / PLUTONEO4X1PLR36WLED840S of Havells
Supply and fixing surfaces mounted (fixing along wall / along pole / steel member of truss including fixing mateial, MS clamps, nut bolts, steel wire etc) LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories, including electric connection complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No BLRB 18W CWc and BLRB-DB 118 of Bajaj / LT8-20-865-2 and DMLN1LT8-16 of Crompton / PHOTONULTRA 1213T8SSTL18WLED865SPC and REGALBATTENT 8UPTO1X22WSSBSWH of Havells
Supply and fixing flood light luminaire, high power LED 300 watt, white light, 100 lumens per watt, energy saving, light weight and with secondary optics, made of pressure die-cast housings with IP 66 rating, complete fitting with LED strips and all other accessories and fitting arrangements including connecting electric connection, complete all as specified and directed by Engineer-in-Charge. Make : Cat part No. LHB-300-CDL/60 of Crompton / BJFL 300W LED I of Bajaj / PCGLFC2 01 300 W of Polycab / SLEFL 300W of Surya
Supply and laying XLPE LT Cable of size 25 Sqmm, 4 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc complete all as specified and as directed by Engineer-in-Charge.
Disconnecting electric connection and taking down carefully serviceable ceiling fans or Exhaust Fans and keep in safe custudy. After completion the building repair work refixing /hanging the ceiling fan as directed including electric connection with and including new flexible copper wire from ceiling rose/connector to fan connector, new nut bolts and split pins etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing High Flo Wave Wall Mounted Fan 400 mm sweep single phase, 230 volts 50 Hz, Pull Chain control type, double ball bearing energy efficiant, metal blades with fine finishing, Rigid frame for protection from foreign matters /Sturdy close-mesh guards including fixing material including electrical connection complete all as specified and directed by Engineer-in-Charge Make - Crompton / Bajaj / USHA / Havells
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge, including taking out/dismantling old unserviceable earthing system. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
R B BUILDERS
G N CONSTRUCTIONS
K L JINDAL AND CO.
R K GOYAL & COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .