| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 CrAccepted-AOC 4 195 38 PARAMESHWARA NILAYA MARAKADA KUNJATHBAIL DAKSHINA KANNADA KARNATAKA 575014 UDYAM KR 11 0021217 | DAKSHINA KANNADA | KARNATAKA | 575014 | ₹29.3 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹36.1 CrRejected-Finance ERODE 638 002 | ₹36.1 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹36.8 CrRejected-Finance GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹36.8 Cr | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹38.7 CrRejected-Finance 610B NILGIRI BLOCK ADITYA ENCLAVE AMEERPET HYDERABAD 500038 | HYDERABAD | TELANGANA | 500038 | ₹38.7 Cr | L4 | Rejected-Finance Not being L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical 1. Physical copies of instrument of tender cost and EMD not received 2. Financial soundness for engagement is inadequate (Against Rs.40 crore only 08 crore limit given) |
| Sl No | Description | Qty | Unit | Sri Avantika Contractors (I) Limited L4 | S.S.NATARAJAN AND CO L2 | VIJAY CONSTRUCTIONS L3 | GOVARDHAN AND COMPANY L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE "A" Part - I (BUILDING & STRUCTURE WORKS)
Details of prepriced schedule is given in tender documents. | 1 | Lump sum | 22,36,00,000 ₹22.4 Cr | 21,90,38,281 ₹21.9 Cr | 23,45,16,480 ₹23.5 Cr | 17,05,57,440 ₹17.1 Cr |
| 2.00 | SCHEDULE "A" PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 12,25,393.8 ₹12.3 L | 7,84,914 ₹7.8 L | 11,48,154 ₹11.5 L | 8,48,153 ₹8.5 L |
| 3.00 | SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 29,48,107 ₹29.5 L | 26,28,111 ₹26.3 L | 19,37,083 ₹19.4 L | 25,69,774 ₹25.7 L |
| 4.00 | SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 69,19,780 ₹69.2 L | 58,95,150 ₹59.0 L | 63,62,962 ₹63.6 L | 60,44,814.11 ₹60.4 L |
| 5.00 | SCHEDULE "A" PART-V (LIFT)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 44,11,150 ₹44.1 L | 48,25,143 ₹48.3 L | 58,18,622 ₹58.2 L | 45,89,656 ₹45.9 L |
| 6.00 | SCHEDULE "A" PART-VI (FIRE FIGHTING)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 15,11,688 ₹15.1 L | 15,44,474 ₹15.4 L | 13,30,472 ₹13.3 L | 16,77,137 ₹16.8 L |
| 7.00 | SCHEDULE "A" PART-VII (ROAD/PATH/ HARD STANDING/CULVERT)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 36,09,586.8 ₹36.1 L | 50,15,324 ₹50.2 L | 43,46,170 ₹43.5 L | 50,54,916 ₹50.5 L |
| 8.00 | SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 2,95,136 ₹3.0 L | 4,05,026 ₹4.1 L | 2,10,985 ₹2.1 L | 3,72,104 ₹3.7 L |
| 9.00 | SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 31,18,044 ₹31.2 L | 35,43,891 ₹35.4 L | 27,15,644 ₹27.2 L | 32,38,624 ₹32.4 L |
| 10.00 | SCHEDULE "A" PART-X (SEWAGE DISPOSAL)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 3,18,812 ₹3.2 L | 4,30,094 ₹4.3 L | 3,74,250 ₹3.7 L | 3,34,152 ₹3.3 L |
Updated dates
Tender Value
₹28.9 Cr
EMD Value
₹15 L
Closing Date
3 Nov 2025, 6:00 pmClosed
Chief Engineer (CG) Goa
Chief Engineer (CG) Goa Pin 403806
PROVISION OF DEFICIENT MARRIED ACCOMODATION AND ALLIED FACILITIES AT NEDUMBASERY, KOCHI
2025_MES_730568_1
84023/E8
Open Tender
Civil Works
840 days
GE (I) (CG) Kochi
As per tender document
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) Kochi
₹15 L
24 Dec 2025
12 Sept 2025
10 Nov 2025
12 Sept 2025
3 Nov 2025
20 Oct 2025
Amount
SCHEDULE "A" Part - I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (LIFT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (ROAD/PATH/ HARD STANDING/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder
INTERNAL WATER SUPPLY Supply and laying of 100 mm outer dia CPVC pipes SDR-11 including plain CPVC SDR-11 fittings like tee / union / elbows / reducers, etc., on walls /ceiling or laying in floors complete all as specified and directed by Engr In charge
S & F of special fittings brass union 100 dia copper alloy, screwed ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Equivalent in Kohler), cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F for 20 mm bore concealed Stop cock regular brass body with spindle extension with Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT) (Make : Jaquar Model No. ALD 089 CQT/ Equivalent in Kohler), cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F 100mm dia gun metal globe or gate valves with iron wheel head , screwed both ends for iron/CPVC pipe or for union and fixed to pipes
S & F of special fittings brass elbow reducer 32 to 25mm dia , screwed ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F of special fittings brass elbow reducer 50 to 32 mm dia , screwed ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F of special fittings brass elbow reducer 100 to 32 mm dia , screwed ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
INTERNAL ELECTRIC SUPPLY Supply and fix power unit for AC with socket and 20 Amp MCB complete. Make : Havells/L&T/Legrand or equivalent
Supply and Fixing surface mounted LED batten 10W with extruded aluminum housing heavy duty integrated electronic driver, surge protection more than 2 KA and THD<10% Make: Havells/WIPRO/PHILLIPS/BAJAJ/Techno commercial or equivalent
S & F wall mounted light fitting with lamp holder including LED lamp of 12 watt connecting up with three core flexible copper conductor cable of suitable size complete. Make : Luker or equivalent
S & F Vertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for Suitable FP MCCB as incomer and TP/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wires & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
Supply and Fix Sheet Metal enclosure for fixing RCBO 4 pole, 63 Amps For Lift
Supply and fix wall fan 400 mm sweep complete with all accessories
S & F GI metal flush boxes 2 module with suitable cover plates
Supply and fix RJ 11 telephone socket 1 module
Supply and fix TV socket 1 module
FIRE FIGHTING Supply & fixing of cast iron Air Release valve suitable for fixing100 dia bore water supply mains including all items to fix the same complete all as specified and as directed.
M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systematic manner to get uniform thickness of coating as per IS specification
M & L for low smoke zero halogen flame retardant fire alarm cable 2 core, 1.5 sqmm copper conductor confirming to BS7629-1,BS6387 & rated for 500 V grade having plain stranded copper conductor with priming insulation of glass mica fire resistance tape & secondary insulation high performance silicon rubber with electrostatic screen of aluminum fire barrier type LT 53 outer sheath confirming to BS 7655,red in colour drawn through & including concealed steel conduit including laying ,fixing, connecting complete all as specified and directed.
S & F wall mounted LED emergency Exit signage luminaries, double sided, Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours
Fire Extinguisher Dry Chemical powder[ABC] type 6 Kg capacity as per IS 15683 with mono Ammonium phosphate powder 50, stored pressure type, pressure Gauge, applicable on class A,B,C & electrically started fire A rating 13 A, B rating 34B , can construction deep down & CO2 Mig welded, Valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyester powder coating, Sheet metal thickness : 1.80MM, ISI and EN approved
Fire Extinguisher Carbon Dioxide type of 4.5Kg capacity light weight squeeze grip type as per IS 15683 complete all as specified
Stored water fire extinguisher 9 L with anti corrosion treated cylinder, Brass Chrome Plated Valve with SS Squeeze Grip Handle TP 42 Bar with inbuilt UGTS Mechanism, safety release device in valve, Aluminium siphon tube etc
Water mist CAF fire extinguisher 9.0 L capacity EN : 3 - 7, Pressure vessel : PESO with special nozzle delivering the droplets as small as 25 microns to create ultra fine mist
Mechanical foam type fire extinguisher of 9.0 L capacity with wall mount hook as per IS 15683 complete all as specified
Fire bucket 9 Ltr for dry sand painted with iron red as per IS 2546 complete
EXTERNAL WATER SUPPLY Supply and fix Cast iron air release valve with 50 mm bore and two outlets as per IS:14845.complete all as specified and directed.
S & F LT Control panel board, indoor type, double door, cubical type, pedestal mounted, of suitable size, CPRI approved having, IP 44, independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar of 200 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board with two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in Siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising the following : Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phase and 100 amp for the neutral bar Incoming:- Incomer :- MCCB 100 Amp,25 KA, 415 volt- 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 100/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB TP 40 Amp,16 KA, 415 volt- 02 No. Ics =100% Icu (b) Change over switch TPN 63 A, 415 Volt - 01 No (c) MCB,SPN,32 Amp, breaking capacity 10 KA- 02 No. Ics =100% Icu Make of MCCB:- Havells/L&T/Indo Asian/ equivalent. (d) DOL starter suitable for 10 HP pump set - 02 Nos (e) Angle iron base frame of required size as per above panel, total leg height 600 mm and grouting inside PCC 150 mm legs and made out of ISA 50x50x6 mm thick angle iron duly painted-01 No
M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m including excavation and earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces( upto 150mm depth below GL for external surface), PCC 1:3:6 type C1 as in coping, 4mm thick MS sheet cover with two Nos of 20mm pintle hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement, frame for cover using angle iron 50x50x6mm, including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted cost shall include all earthwork and connected items as specified.
EXTERNAL ELECTRIFICATION Cutting of bituminous road, PCC surface/floor by using mechanical method or suitable method as per direction of Engineer In Charge carefully without damaging adjacent area and making good the cut portion and disturbed surfaces to match with the adjacent surface using the same specification of the adjacent surface, complete all as specified and directed.
(d). Outdoor Enclosure : Outdoor type enclosure having construction of Galvanised Sheet Steel. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for Transformer compartment. The enclosure exterior shall be Powder coated (Color -RAL-1001-Cream). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. (e). Interconnection & Earthing : Interconnection Between HT switchgear & Transformer using 1Cx3Rx95Sq.mm XLPE Al Single core cable & Interconnection between Transformers to LT switchgear using Aluminium bus bars. Internal earthing connections including Transformer Neutral by using 50x6 mm GI Strips.
Supply & installation 12 kV, SF6 Ring Main Unit complete both side Extensible, Outdoor type with 2 Nos of Isolator (Load Break Switch) and 01 No Breaker (High performance VCB), motor operated complete with the following specifications :- Make-Schneider ( HSN Code; 8537 ) or equivalent Type - Outdoor Rated Voltage - 12 KV Operation Voltage - 11 KV Rated lightning withstand voltage - 75 KV Rated Frequency - 50 Hz Rated short circuit current - 21 kA Bus bar rating - 630 Amp Vacuum Circuit Breaker - 630 Amp (Fixed type)
S & F LT Control panel board, outdoor type, double door, cubical type, pedestal mounted, of suitable size, CPRI approved having, IP 55, independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal Aluminium bus bar of 750 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in Siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Main LT Panel. The LT Panel comprising of the following:-
Incoming:- Incomer :- MCCB 4 Pole, 415 V, 36 KA with Thermal Magnetic Release (Manual Fixed type) of capacity 400 Amps Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 600/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320 Amps, breaking capacity 36 KA- 01 No. Ics =100% Icu (for building Panel) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, breaking capacity 25 KA- 01 No. Ics =100% Icu ( for AMF panel) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 25 KA - 03 No. Ics =100% Icu (for APFC panel + 1 spare + 1 Solar) (e) Angle iron base frame of required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50x50x6 mm thick angle iron duly painted- 01 Nos
All as per item 12.37 but indoor type with the following accessories:- LT Panel No.2 ( Main building Panel ) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 500 Amps Incoming:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320 Amps, breaking capacity 36 KA - 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 25 KA- 01 No. Ics =100% Icu (for spare) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 07 Nos. Ics =100% Icu ( for First floor to seventh floor) (c) Angle iron base frame as required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50x50x6 mm thick angle iron duly painted-01 Nos
All as per item 12.37 but with the following accessories:- LT Panel No.3 (DG panel) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 250 Amps Incoming:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, breaking capacity 25 KA - 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 02 Nos. Ics =100% Icu ( Fire fighting and Alarm + Spare) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 40 Amps, breaking capacity 25 KA- 04 Nos. Ics =100% Icu ( for lift 02 Nos + Common Area 01 No + street light 01 No) (c) Angle iron base frame of required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50x50x6 mm thick angle iron duly painted-01 Nos
M & L for PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 of 2.5 Sqmm, 3 core all as specified and as directed
Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimum size 255 x 355 x 122 mm including suitable Cable connecting Terminals, Cable lugs, including provision of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. Make: Hensel or equivalent as approved.
S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length 1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc complete etc all as specified.
Supply and fix electric chimney single phase AC 230 volts wall mounted 90cm size suitable motor and fan that provide suction to pull in and expel smoke, odour and air borne particles produced during cooking and automatic sensor operation and LED lights
AVIATION OBSTRUCTION LIGHT Supply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure (Make Bajaj Cat No BGAV 302 LED)
SOLAR POWER PLANT Design, supply and installation of Ongrid Solar system on rooftop of capacity 60KW consisting of following. a) Ongrid solar three phase Inverter having BIS certification and IEC certification approved by MNRE. The Inverter will have online monitoring system ( Wi-Fi connection to be provided by User). The inverter will have inbuilt surge suppressor. The Inverter shall come with manufacturer’s guarantee of minimum 7 years. b) Photovoltaic panels used will be from ALMM list approved by MNRE confirming to DCR. The combination of panels will be of 335Wp capacity of 180 Nos or 545 Wp of 120 Nos. The panel will come with manufacturers performance guarantee of 25 years. c) The Panels shall be installed on roof with mounting structure of Pre galvanized steel of various section and aluminium clamps and stainless steel bolts. d) Separate Chemical Earthing to be provided for Inverter, solar panels etc. The chemical earthing shall be done by using copper bonded rod of one meter length. With copper earhing strip of 20x3.15 mm e) Lightning arrestor with hollow copper rod of one meter length with aluminum down conductor of 20 SQMM connected to copper bonded rod of one meter length with pit filled with chemical. f) The DC cable of size 4 sqmm will be used for interconnecting panels and the inverter. The wire will be having ISI marking. The wiring will be done using ISI make conduit pipe. g) The AC wiring will be done using cables of proper size with ISI marking. h) The system will consist of DC DB of proper rating having surge suppressor type 2 and DC fuse protection. i) The system will consist of AC DB of proper rating having MCB of proper rating with ISI marking also surge suppressor type 2. j) The Bus bar box of proper rating will be used. The Busbar box will have ISI mark.
k) The net meter and generation meter of make approved by KERALA State electricity board shall be used and it should be tested from KERALA State electricity board and then Only installed. l) The cost will include liasioning with KERALA State electricity board and execution of agreement with KERALA State electricity board The Rates shall be Inclusive of GST 1. The rates shall be inclusive of transportation of the required material 2. The rates shall be inclusive of liaison work with KERALA State electricity board for getting permissions for RTS and getting the agreement signed between MES and KERALA State electricity board for the RTS net metering. 3. The subsidy on the above project can be obtained from SECI (Solar Energy Corporation of India) . The application for the same to SECI will be made by MES & contractor Incorporated will extend full support in helping to complete the required documentation and provide inputs and information to the process. Note - Design of OnGrid Solar Plant to be vetted by IIT/NIT & get approved by Accepting officer before commencement of work
Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mm conforming IS 16205 (Part 24 ) for protection of electric cable complete all as specified and directed.
DG SET Supply and installation of silent Diesel Engine driven generating set 415 Volts, 3 Phase, 4 wire, engine as per IS:10001/10002 and Alternator as per IS:13364 complete with relay panel and switch gears for automatic starting on main failure (AMF), control panel having meter and sound proof canopy as per latest CPCB norms and foundation etc. of capacity 62.5 KVA including AMF panel with following specifications :- Power rating : 62.5 KVA/50 KW Rated Current : 87 Amp Voltage : 415 Volts / 50 Hz (Three Phase) Engine Rating : 61 KW / 83 BHP No of cylinders : 04 Nos Fuel tank capacity : Min 12 Hrs Capacity Noise Level : 75 db at 1 Mtr distance The DG set shall comply latest CPCB norms Note : The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016.
SEWAGE DISPOSAL M & L for laying of DWCPE sewage pipes line 150 mm dia bore pipe stiffness class SN 8 including sealing of joints fittings etc complete with collars complete all as specified and directed
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 using 20 mm graded stone aggregate in cast in situ bored pile of any length/any sections as shown on drg complete all as specified and directed. Note: Minimum cement content for M-30 design mix for pile shall be 400 kg/cum and cement for pile shall be SRPC.
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 using 20 mm graded stone aggregate in pile caps complete all as specified and as shown on drg. Note: Minimum cement content for M-30 design mix for pile cap shall be 400 kg/cum and cement for pile cap shall be SRPC.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends as necessary and binding with and including 0.9mm dia MS wire annealed or welded so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5 mm dia and over up to and including 10mm dia and conforming to IS-1786 as Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS wire annealed or welded so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends as necessary and binding with and including 0.9mm dia MS wire annealed or welded so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs.
M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps complete all as specified and directed.
Formwork to sides of pile caps rough finished surface of concrete flat all as specified and as directed.
M & L for carrying out Initial Load test (vertical load test) for cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. (Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial (lateral load test) for cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. (Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial load test ( pull out test) for cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial Load test (vertical load test) for cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial load test ( pull out test) for cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Routine load Test (Vertical load) all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M & L for carrying out Routine load Test (Vertical load) all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
Retractable cloth drying system. S & F pulley operated cloth drying system(pull it pulley system) of 6 feet length with 04 SS pipes, ropes and all allied accessories, complete all as specified and as directed. Note: Stainless steel pipe should be of minimum diameter 15mm, SS 304 Grade, Sch-10S. Body of pulley shall be stainless steel with nylon wheel with rope guide mounted on channel. locking shall be mounted or fixed with self-tapping screw. Rope shall be polyester braided undyed of 3.4mm dia. Make- easydry or equivalent
GREEN BUILDING NORMS(Griha concepts) Supply, installation, testing and commissioning single phase energy meter with the following specifications: Microprocessor based single phase tamper proof electronic static pre paid cum postpaid energy meter rating 240 Volts, 50 HZ of range 10-60 Amps, complying to IS16444 :2015 (reaffrimed 2020)and conforming to IS 13779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default /in built dual source, inbuilt long range Communication suitable for outdoor data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty. Make: Elmeasure of Model: PE5121 or equivalent in Secure, L&T, Schneider, HPL etc. Note: (a) The Energy Meter to be capable of running in both prepaid and postpaid mode (b) The meters to carry 5 year warranty.
Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase tamper proof electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 HZ of range 10-60 Amps, complying to IS16444 :2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default /in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty. Make: Elmeasure of Model: PE5121 or equivalent in Secure, L&T, Schneider, HPL etc. Note: (a) The Energy Meter to be capable of running in both prepaid and postpaid mode. (b) The meters to carry 5 year warranty.
Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules: (a) Meter Data Management Module The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the following data: (i) 30 min instantaneous data from all the meters for seven parameters - Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency ii) Monthly billing survey data for cumulative energy and max demand
(b) Billing Module :The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required. (c) Occupation and Vacation Module : The system would support occupation / vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events. (d) Customer Module : The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. (e) Energy Accounting Module :The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (f) Communication Module : The system would provide communication of energy data and bills via print, email and sms methods (g) Meter Master Data:The system would support meter master data repository. The system would support meter replacement process. (h) Excel Export: The system would support export of metering and billing data in excel format.
Hosting GPRS (4G) charges for two Gateways for four years warranty from the date of completion (Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone
PHASE-II (Item No. 12.77 to 12.82) COMPREHENSIVE MAINTENANCE OF LIFT Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of 01 number of electrically operated Passenger Lift of capacity 08 Passengers and 1 number of electrically operated Passenger Lift of capacity 13 Passengers, speed 1.5 m/s with single speed motor, 415 V, 3 phase AC 50Hz supply suitable to serve G+7 upper floors with AC variable voltage and variable frequency drive(VVVF drive) complete with all standard accessories including ARD and batteries, simplex automatic & manual dual controlled operation with/without attendant, center opening doors with door drive(electric motor driven mechanism), sliding stainless steel door, infra red sensor including repairs/ replacement of all defective and unserviceable parts during contact period, attending breakdown as and when intimated including necessary periodical safety checking and testing of lifts as mentioned in relevant code of practice/IE for the safe and efficient and trouble free performance of lifts installed under relevant schedule here in before through out 12 months on all days including Sundays & holidays for first year during defect liability period all as specified and directed
All as per item 12.77 above but for 2nd year during defect liability period.
All as per item 12.77 above but during 1st year after expiry of defect liability period.
All as per item 12.77 above but during 2nd year after expiry of defect liability period.
All as per item 12.77 above but during 3rd year after expiry of defect liability period.
S.S.NATARAJAN AND CO (BID ID -3460180)
VIJAY CONSTRUCTIONS (BID ID -3460293)
Sri Avantika Contractors (I) Limited (BID ID -3459411)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
DRG1.rar
Additional Documents • 11.20 MB
84023TENDERPAGES.pdf
Tender Documents • 2.38 MB
DRG2.rar
Additional Documents • 21.06 MB
DRG3.rar
Additional Documents • 11.54 MB
BOQ_817898.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid