Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹13.5 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹14.8 L+₹1.3 L (9.28%)Rejected-Finance | ₹14.8 L+₹1.3 L (9.28%) | L2 | Rejected-Finance Other then Lowest Bidder |
| 3 | l3₹18.1 L+₹4.6 L (33.7%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹18.1 L+₹4.6 L (33.7%) | l3 | Rejected-Finance Other then Lowest Bidder |
| Sl No | Description | Qty | Unit | V r traders L3 | KAPOOR ELECTRICALS L1 | trinity construction L2 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting & Taking out existing change over swtich from MRS LT panel room and supply and fixing commissiong , testing 630 A change over switch in 400 KVA genereator room including all necessary fixing arrangement & connceting LT Cables with suitable legs/thimbles as requied etc complete all as specified and directed. | 1 | Each Job | 29,999 ₹29,999 | 33,000 ₹33,000 | 25,000 ₹25,000 Lowest |
| 2.00 | M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric H T power cables (heavy duty) with aluminium conductor, 11000 volts Earthed,,grade cross sectional area 95 sq. mm 3 core complete all as specified and directed | 185 | RM | 1,049 ₹1,94,065 | 1,300 ₹2,40,500 | 900 ₹1,66,500 Lowest |
| 3.00 | Supply, laying, connecting and testing in repalcement XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty ) 1100 Volts grade with stranded aluminium conductor cross sectional area 400 sqmm 3.5 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed. | 49 | RM | 1,099 ₹53,851 Lowest | 2,222 ₹1,08,878 | 1,800 ₹88,200 |
| 4.00 | M & L for servicing of (as described below) indoor/ outdoor type HT 11 KV VCB , VCB of various capacity. (a) Servicing and inspecting of draw out type trolly mounted, manual spring charge ON-OFF mechanism and testing for proper functioning of ON and OFF operation ,servicing of male female contacts,greasing all the mechanical components and applying dry graphite conductive sealent for contacts.(b) Cleaning,inspecting and testing HT 11 KV bus bar ,Checking of insulators at input and output for any crack of damages, Checking of cable termination for all the three phases, Cleaning the copper bus bar , checking for proper insulation ,tightening all the nuts ,bolts of bus bar.(c) Cleaning ,inspecting and testing of electrical wiring system, ammeter,voltmeter, VAF meter, selector switch, all illuminated indicators for RYB phase ,DC supply healthy,spring charge ,trip circuit healthy etc(d) Cleaning, inspecting and testing for over current relay ,CT for ammeter ,PT for voltmeter for display of voltage HT 11 KV (e) Setting of earth fault relay and over current relay as per ,manfactrurers's recommendetion and site requirement . | 7 | Each Job | 1,999 ₹13,993 | 300 ₹2,100 Lowest | 4,500 ₹31,500 |
| 4.01NOTE: (i)Cost of all the material , components, repairs, elements as per above as well as other elements (except supply only of the components considerd under items herein after to the extent required and operated ) to make the VCB complete functional shall be deemed to be included in the quoted rate of the contractor. | ||||||
| 4.02(ii)Individual Breaker VCB consider as one unit and above job is to be carried out unitwise.Above job will be carried out by licenced technician as aproved by GE. | ||||||
| 4.03(iii) Any accident/mishapenning occurred during the execution of work shall be responsibity of Contractor. | ||||||
| 4.04(iv) All necessary tools & plants required to carry out above job will be provided by contractor and the cost of the same are deemed to be included in quoted rate. | ||||||
| 4.05(v) Inventory of defective parts to be replaced by contractor will be prepared by joint inspection with contractor | ||||||
| 5.00 | M & L for calibration IDMT microprocessor based numeric relay (Three nos over current and one no earth fault relay) fixed in 11 KV HT panel by primary and secondary injection method and setting the relay tripping timing in advance to match the outgoing load on the incoming and out going feeders complete all as specified and directed | 6 | Each Job | 2,499 ₹14,994 | 300 ₹1,800 Lowest | 6,000 ₹36,000 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
21 Jul 2026, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun-248003
REPAIR /MAINTENANCE OF HT EXTERNAL ELECTRIFICATION, EXTERNAL WATER SUPPLY AND OTHER MISC E/M WORKS AT NHO AND PCDA(AF) UNDER GE CLEMENT TOWN
2026_MES_773745_1
85463/CTL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE Clement Town
Class E Cat b (ii)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town Dehradun
₹40,000
Yes
23 Sept 2026
20 Jun 2026
29 Jul 2026
20 Jun 2026
21 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting & Taking out existing change over swtich from MRS LT panel room and supply and fixing commissiong , testing 630 A change over switch in 400 KVA genereator room including all necessary fixing arrangement & connceting LT Cables with suitable legs/thimbles as requied etc complete all as specified and directed. | 1 | Each Job | 41.7 | ₹41.7 |
| 2 | M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric H T power cables (heavy duty) with aluminium conductor, 11000 volts Earthed,,grade cross sectional area 95 sq. mm 3 core complete all as specified and directed | 185 | RM | 41.7 | ₹7,714.5 |
| 3 | Supply, laying, connecting and testing in repalcement XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty ) 1100 Volts grade with stranded aluminium conductor cross sectional area 400 sqmm 3.5 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed. | 49 | RM | 41.7 | ₹2,043.3 |
| 4 | M & L for servicing of (as described below) indoor/ outdoor type HT 11 KV VCB , VCB of various capacity. (a) Servicing and inspecting of draw out type trolly mounted, manual spring charge ON-OFF mechanism and testing for proper functioning of ON and OFF operation ,servicing of male female contacts,greasing all the mechanical components and applying dry graphite conductive sealent for contacts.(b) Cleaning,inspecting and testing HT 11 KV bus bar ,Checking of insulators at input and output for any crack of damages, Checking of cable termination for all the three phases, Cleaning the copper bus bar , checking for proper insulation ,tightening all the nuts ,bolts of bus bar.(c) Cleaning ,inspecting and testing of electrical wiring system, ammeter,voltmeter, VAF meter, selector switch, all illuminated indicators for RYB phase ,DC supply healthy,spring charge ,trip circuit healthy etc(d) Cleaning, inspecting and testing for over current relay ,CT for ammeter ,PT for voltmeter for display of voltage HT 11 KV (e) Setting of earth fault relay and over current relay as per ,manfactrurers's recommendetion and site requirement . | 7 | Each Job | 41.7 | ₹291.9 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender85463.pdf
Tender Documents • 1.17 MB
BOQ_866377.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .