Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | L1 | Accepted-AOC 1st LOWEST | |
| 2 | L2₹9.5 L+₹57,549 (6.44%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹10.2 L+₹1.3 L (14.5%)Rejected-Finance WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹10.5 L+₹1.6 L (17.8%)Rejected-Finance HOUSE NO 04 NEW SARASWATI VIHAR NEAR PAWAN VIHAR PHASE 6 OVER HEAD TANK BAREILLY 243006 UP | BAREILLY | BAREILLY | UP | 243006 | L4 | Rejected-Finance 4th lowest | |
| 5 | L5₹10.9 L+₹2.0 L (22.1%)Rejected-Finance | L5 | Rejected-Finance 5th lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Aug 2020, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR MAINT OF SUB MAIN WIRING DBs AND CONNECTED WORK UNDER GE EAST BAREILLY
2020_MES_358358_1
C/8845/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer East
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE EAST BAREILLY
₹30,000
Yes
11 Sept 2020
4 Jul 2020
7 Aug 2020
4 Jul 2020
5 Aug 2020
24 Jul 2020
4 Jul 2020 - 18 Jul 2020
Amount
Taking down copper/aluminum point wiring (Light fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting holders etc, removing materials for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of wall, floors etc complete all as specified and directed.
Taking down electric meter duly disconnecting from electric connection and removing to store for keeping in safe custody for refixing etc complete all as specified and directed.
Taking down light fittings of any and removing for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of wall, floors etc complete all as specified and directed.
Taking down main switch / MCB/ DBS including MC BS etc of any size removing for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of wall, floors etc complete all as specified and directed.
Taking dowm sub main wiring including earth wire and making good disturbed surfaces to match with the existing surfaces of walls including removing from site for credit complete all as specified and directed.
M & L for point wiring with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor FRLS 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) drown through and including PVC Casing & Caping with all accessories including 1.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and concealed sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switches with 3 mm thick hylum laminated sheet cover complete all as specified and as directed for one light point controlled by one switch.
All as per item No 6 herein before but One light point controlled by two, two way switches complete all as specified and directed.
S&F switch piano flush type single pole, 230 Volts, 5 Amp, one way complete all as specified and directed.
S&F switch piano flush type single pole, 230Volts, 5 Amp, two way complete all as specified and directed .
S&F ceiling roze, 3 terminals, 230 Volt, PVC polycarbonate isolated body complete all as specified and directed
S&F bulk head luminaire 10 watt LED oval shaped in Engineering plastic housing with clear prismatic diffuser, heat sink integrated with housing, IP-65 including one No. 10Watt LED lamp complete all as specified and directed.
Supply & fixing ultra slim LED 1x20 Watt MS batten T8 batten white powder coated decorative end cap complete with retrofit polycarbonate glass tube LED 20Watt 4' long including suitable electric connection with 3 core flexible PVC insulated copper conductor, multistranded, cable of size 1.0 sqmm complete all as specified and directed.
Fixing only and connecting electric meter upto 25 Amp received against item srl item-2 here in before complete all as specified and directed..
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through in PVC conduit/ PVC Casing & Caping complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through in existing PVC conduit/ PVC Casing & Caping complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire will be measured as one unit.)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in PVC conduit/ PVC complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in existing PVC conduit/ PVC Casing & Caping complete all as specified and directed.. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through in PVC conduit/ PVC complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through in existing PVC conduit/ PVC Casing & Caping complete all as specified and directed.. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
S&F sheet metal enclousers (DBS) when MCBs to be used 4 way, 415 Volts, double door, tripple pole & neutral prewired Vertical ( VTPN) made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar with 125Amp MCCB, IP-54 protection, door earthing & isolated Neutral bar complete all as specified and directed. ( NOTE:- MCBs are to be measured and paid seperately)
S&F sheet metal enclousers (DBS) when MCBs to be used 4 way, 240Volts, double door, Single pole & neutral prewired made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar complete all as specified and directed. ( NOTE:- MCBs are to be measured and paid seperately)
S&F sheet metal enclousers (DBS) when MCBs to be used 8 way, 240 Volts, double door, Single pole & neutral prewired made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar complete all as specified and directed. ( NOTE:- MCBs are to be measured and paid seperately)
S&F sheet metal enclousers (DBS) when MCBs to be used 12 way, 240 Volts, double door, single pole & neutral prewired made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar complete all as specified and directed. ( NOTE:- MCBs are to be measured and paid seperately)
S & F in replacement MCCB 100Amp, 415 Volt, 16 KA, 4Pole complete all as specified & directed.)
S&F MCB SPN 32 to 63 A, 230 V, 10 KA, B curve type complete all as specified & directed.
S & F in replacement MCB SPN 32A to 63 A, 230V, 10KA, B' curve type complete all as specified and directed.
S&F MCB SP 32A-63A, 230V,10 KA, B curve type complete all as specified and directed).
S&F in replacement MCB SP 32A-63A, 230V,10 KA, B curve type complete all as specified and directed.
S&F Blanking plate PVC.
VINYAK TRADERS
N S ELECTRICALS
S S CONSTRUCTION CO
Shri Siddhi Vinayak Constructions
M/S Quality Constructions
R. S. Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .