Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.8 LAccepted-AOC | 1 | Accepted-AOC accepted |
Tender Value
₹3.7 L
EMD Value
₹7,474
Closing Date
30 May 2020, 3:00 pmClosed
Executive Engineer (E)
BSNL Electrical Division , Main Telephone Exchange bldg. Ambala Cantt
PITC of addressable Fire Detection and Fire Alarm system
2020_BSNL_46827_1
EE/E/BSNL/AB/2019-20/56
Open Tender
Electrical Works
Works
30 days
KALPI Ambala
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
Accounts Officer (Cash) O/o The CGMT BSNL Ambala
₹7,474
Yes
8 Aug 2020
11 Apr 2020
5 Jun 2020
11 Apr 2020
30 May 2020
11 Apr 2020
Amount
Fire Alarm Control Panel (FACP): SITC of UL/ ULC/ EN 54/ CE listed Analogue addressable micro Processor controlled, Standalone Main Fire Alarm Control Panel having 1 loop (1 Loop Card) (with minimum 99 detectors/ 99 devices capacity per loop card) with LCD display , capable of being networked to the central monitoring System to monitor and integrate with other panels such as Access control System along with accessories like detectors, LCP's, hooters, control modules, monitor modules Fault Isolation Modules, response indicators, fire/ fault indicators, audio-visual signals, central processing units, complete with LCD display, zone indicating LEDs, having multiple access levels, event history file in non-volatile memory (EEPROM) as per the detailed specification, complete with PSU, Battery backup along with charger for 24 hours in non-alarm condition and 30 minutes in alarm condition etc. as required for each panel . The panel shall have a built in power supply and battery charger along with maintenance free 7 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger and conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL as per specifications complete in all respect [Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
One loop Panel
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. [Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
a) On Visible False Ceiling
b) Above False/ True Ceiling
c) Below False Flooring
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. [Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying, installation, testing & commissioning of addressable fire control module complete as required.[Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying, installation, testing & commissioning of addressable phone control module complete as required.[Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying, installation, testing & commissioning of addressable manual call point complete as required.[Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.[Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying, installation, testing & commissioning of fault isolator complete with base as required. [Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying, installation, testing & commissioning of response indicator on surface/ recessed MS Box having two LED, metallic cover complete with all connections etc as required. [Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/ 1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.( 2x1.5sqmm)
Supply Installation Testing and Commissioning of Laser etched LED Emergency Exit Signage (single side) on ceiling/ wall mounted (with Logo & Exit arrow) etching on etc. 8mm + 8mm transparent acrylic sheet of 350x220mm (nominal size) with extra super bright LED's in glass Epoxy PCB strip concealed in top mounted suitable size 20SWG MS box duly powder coated and equipped with necessary circuit to step down from 230V AC to 6V/ 12V DC with nickel cadmium batteries and battery charger as required. [Make: M/s. Honeywell (Notifier/ System Sensor/ Morley)/ Kidde/ UTC Fire & Security (GST/ Edward)/ Siemens/ Fire Finder/ Bosch]
Supplying and fixing of 4.5Kg capacity CO2 (Carbon Dioxide) type fire extinguisher confirming to IS:15683 and cylinders duly charged complete with 1mtr long hose pipe & horn and other accessories commissioning etc. complete as required. (Make -Safex/ Omex/Safeguard/Lifeguard ISI Mark )
Supplying and fixing of following accessories for installation of detectors on true ceiling/ false ceiling/ false floor complete as required.
(a) MS tripod stand for in the false floor for supporting detectors complete with all accessories.
(b) Suitable size MS box for mounting detector base complete with loop in & loop out cable glands
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing of UTP 4pair cat-6 Lan cable in the existing surface/ recessed steel/ PVC conduit as reqd. ( One run of Cable )
NOTE (1) :- All accessories (i.e. photothermal detector, thermal detector, fire control module, phone control module, manual call point, addressable horn cum strobe, fault isolator, response indicator etc.) shall be of the same make as of Fire Alarm Control Panel
NOTE (2) :- Coloured Wiring Diagram showing all accessories and main control panel in single line duly laminated on the wooden board have to be fixed at site free of cost & three sets of the same diagram in hard copies along with operation & maintenance manuals have to be supplied at the time of handing over/ taking over.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .