| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical H NO G 3G F PLOT NO 11 MANISH AVINAB PLAZA MLU SECTOR 4 DWARKA NEW DELHI 110075 | SOUTH WEST | DELHI | 110075 | Accepted-Technical The firm fulfills all the parameters of NIT, hence Qualified for next stage. |
| 2 | Accepted-Technical | Accepted-Technical The firm fulfills all the parameters of NIT, hence Qualified for next stage. |
| 3 | Accepted-Technical VILLAGE LAPKAN POST SHAHPUR RANIGANJ DISTT PRATAPGARH 230304 | PRATAPGARH | UTTAR PRADESH | 230304 | Accepted-Technical The firm fulfills all the parameters of NIT, hence Qualified for next stage. |
| 4 | Accepted-Technical | Accepted-Technical The firm fulfills all the parameters of NIT, hence Qualified for next stage. |
| 5 | Rejected-Technical | Rejected-Technical As the firm failed to submit relevant documents as per TEC Report, Hence, Rejected/Disqualify. |
Tender Value
₹67.9 L
EMD Value
₹2.0 L
Closing Date
19 Jan 2026, 10:00 amClosed
Commandant (Engineer)
CONTRACT CELL, CENTRAL ZONE HQR, CRPF, STREET NO. 299, DJ BLOCK, NEW TOWN AREA-III, NEAR JALVAYU TOWER, NEW TOWN, KOLKATA (W.B.) PIN-700160
Construction of damaged boundary wall i/c concertina coil at different location
2026_CRPF_893858_1
B.V(GC Kathgodam) Spl. Repair/2025-26-CZ-C/Cell (NIT-80)
Open Tender
Civil Works - Buildings
Item Rate
120 days
GC, CRPF, Kathgodam, Distt-Nainital (Uttrakhand)
As per tender enquiry
13 documents required · 13 mandatory
₹0
₹2.0 L
29 Jan 2026
14 Jan 2026
20 Jan 2026
14 Jan 2026
19 Jan 2026
14 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand). With Modular bricks
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement :4 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Welding by gas or electric plant including transportation of plant at site etc. complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)
Neat cement punning.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2mm, supplied @ 3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.18 MB
BOQ_939526.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .