Loading…
Loading…
Tender ID
Tender Value
₹25 L
EMD Value
₹20,000
Closing Date
2 Apr 2026, 6:00 pmClosed
Ex.Eng (O&M) Valsad Rural Division
Erection & Maintenance and Labour works for Laying, testing & commissioning of 11/22 KV underground / Overhead XLPE cable (XLPE cable to be supplied by DGVCL), with cable End termination & straight through jointing kits (to be supplied by contractor) for Various feeder under jurisdiction of Dharasana subdivision under Valsad Rural Division under SI & Other Various Scheme.
288300
DGVCL/VALSAD-R DO/E-TENDER/2025-26/124
Open
Miscellaneous Works
Works
Valsad
8 documents required · 8 mandatory
₹1,180
Yes
DGVCL, Payable @ Valsad
₹20,000
Yes
20 Mar 2026
20 Mar 2026
20 Mar 2026
2 Apr 2026
20 Mar 2026
Item Code Details of works Unit FY 2024-25
(A) LINE MAINTENANCE
1 9924000001 Cutting of Tree branches surounding HT/LT line
Replacement of old jumpers & providing new
2 9924000002 double jumpers with 8" binding [D Type] & No.
capsuling with PVC pipe etc
3 9924000005 Support pole for Stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per
pole in costle area with cleaning .
6 9924000008 Pin binding of conductor LT shakel insulator No.
Replacement of one/both disc.insulator at strain
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Refixing of V cross Arm No.
Replacement of V cross Arm (With Transportation
11 9924000013 Refixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting &
jumpuring(ONE DO FUSE)
Numburing of pole with paint by preparing back
15 9924000017 ground of one colour and have lettering(height 3" No.
* width 0.5") using stensil
16 9924000018 Fixing of MMB(1PH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (1ph.) meter for Urban area No.
19 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with
letter size height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with
letter size height 40mm* width 8mm)
Replacement of deteriorated Single phase Service
Fixing of new dist. Box with complete wiring
including clamps,nut bolts etc.
Reparing of guarding involving reshaping of
bearer wire cross lacing binding etc.
Painting of steel fabricated material of RSJ DO DP
structure with paint
Painting of steel fabricated material of RSJ pole
26 9924000028 mounted transformer double pole structure with No.
Painting of steel fabricated material of RSJ single
pole with paint
painting of steel fabricated material of PSC Single
pole (HT line) with paint
painting of steel fabricated material of PSC DO DP
double pole with paint
painting of steel fabricated material of PSC
30 9924000032 double pole at pole mounted transformer with No.
31 9924000033 Providing line seperater single phase No.
32 9924000034 Providing line seperater three phase No.
Replacement / Providing of stay insulator along
with adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist.
34 9924000036 Box with new up to 100KVA capacity & crediting No.
Replacement of deteriorated /providing LT dist.
35 9924000037 Box with new above 100KVA capacity & crediting No.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
Converting pin point to Shackle point including locatio
dismentaling & restringing etc. n
replacement of 11KV Pin insulator with providing
new double pin binding
replacement of 22KV Pin insulator by new 11kv
40 9924000042 pin insulator with spares & providing new double No.
Providing 11kv double disc insulators with binding
Replacement of existing 11kv conductor (all size) Cond/K
with new double pin binding M
Plumbing of PSC Pole with straightening at pin
Plumbing of PSC Pole with straightening at
Plumbing of tilted DP structure (PSC/RSJ/STP)
with refilling of stone Murrum etc.
Providing new 11kv AB /GO switch with
46 9924000049 fabrication and insulated colour code jumper, Set
binding, lugs etc
Replacement of old 11kv AB /GO switch with
providing new insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line per
with using PVC reel insulators etc pole
Labour charges for replacement /providing of
49 9924000053 MMB & service with all accessories for three phase No.
Labour charges for replacement /providing of
50 9924000054 MMB & service with all accessories for single No.
phase connection
Dismentalling of existing Dist.X'mer center(RSJ
51 9924000055 /STP POLE) 25/63/100/200 KVA with all No.
fabrication & creditig the old material to store
52 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole
& crediting to S/dn (1 ph.)
Dismentaling & removing of service line from pole
& crediting to S/dn (3 ph.)
Reconnection of service line complete with PVC
Reconnection of service line complete with PVC
Providing spiral type earthing by G.I. NO 8(weight
2kg -5mtr in length) with salt and coal 10kg each,
including pvc rigid pipe 20mm dia( 1.5mtr length)
to pass exposed part of G.I. wire at consumer
end with all materials, earth resistance should be
less than 2 ohms
Providing and fixing of signle core 1.5 sq mm
single strand copper insulated cable with cable
nail clip for spiral type earthing at consumer end.
The end of G.I. no 8 is to be connected by
connector with copper cable of which other end per
shall be connected to the earth terminal of meter meter
box. This item shall be used in location where
there is more distance between earth terminal
and earthing terminal of meter. (All materials
supplied by contractor)
9924000065 Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ
MM including fitting of all accessories i.e. special
design suspension / tension clamp, fixing of cross
arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling
charge of existing bare conductor and crediting in
to store & dismantling of service line from LT bare
conductor and to provide service connection on
Aerial Bunch Cable by insulated piercing
connectors through service connection box
complete as required & directed by Engineer in
9924000066 Stringing of LT ABC of 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM including fitting of all
accessories i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and
63 inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismantling
of service line from LT bare conductor and to
provide service connection on Aerial Bunch Cable
by insulated piercing connectors through service
connection box complete as required & directed
by Engineer in Charge.
9924000067 Stringing of 11KV ABC of 3*95 SQ MM +80 SQ
MM including fitting of all accessories i.e. special
design suspension / tension clamp, fixing of cross
arm, binding to pin insulator, preparing shackle
point, jumpers etc. and inclusive of dismantling
charge of existing bare conductor and crediting in
to store complete as required & directed by
Engineer in Charge.
9924000068 Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ
MM including fitting of all accessories i.e. special
design suspension / tension clamp, fixing of cross
arm, binding to pin insulator, preparing shackle
point, jumpers etc. and inclusive of dismantling
charge of existing bare conductor and crediting in
to store complete as required & directed by
Engineer in Charge
9924000069 Stringing of LT ABC of 2*50 SQ MM +1*25 SQ
MM+ 35 SQ MM including fitting of all accessories
i.e. special design suspension / tension clamp,
fixing of cross arm, LT shackle insulator etc. for
fixing of messenger wire and inclusive of
dismantling charge of existing bare conductor and
crediting in to store & dismantling of service line
from LT bare conductor and to provide service
connection on Aerial Bunch Cable by insulated
piercing connectors through service connection
box complete as required & directed by Engineer
-::- SCHEDULE – ‘B 3’: FOR Underground -::-
LABOUR RATE FOR UNDERGROUND CABLE WORK (WITHOUT GST)
Item Code Description Unit FY 2024-25
Labour charge for excavation of
cable trench of 400mm width x
1200mm depth, in any type of
soil for laying of cable of size up
to 240 mm2 (For additional
cable 200 mm additional width
shall be considered i.e. half
trench length is to be considered)
Labour charge for excavation of
cable trench of 600mm width x
1200mm depth, in any type of
soil for laying of cable of size up
to 240 mm2 (For additional
cable 200 mm additional width
shall be considered i.e. half
trench length is to be considered)
Labour charge for excavation of
cable trench of 400mm width x
1500mm depth, in any type of
soil for laying of cable of size up
to 240 mm2 (For additional
cable 200 mm additional width
shall be considered i.e. half
trench length is to be considered)
Labour charge for laying of 11kV
/ 22 kV XLPE Cable of size up to
240 mm2 & preparation of sand
layer 100mm thick, in the cable
trench & covering the cable with
150 mm dia (Inner), thickness
25 mm, 1.0 meter long RCC half
round muffs and providing and
fixing of 4inch width yellow colour
polyethylene tape with printing
"CAUTION ELECTRIC CABLE
BELOW" at 0.75 m depth from
ground surface after laying cable
in trench. This will provide
indication that electric cable is
passing underground so as to
protect cable from mechnical
injuries, refilling the same, as per
Instruction of Engineer in Charge
Labour charge for horizontal
drilling using Auger machine
without damage to surface road
at max 2.0 mtrs depth & putting
of 6.11 kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5mm
thickness H.D.P.E. pipe confirms
to IS 4984-1987(3rd revision)
and BIS certification and laying
of 11KV/22KV XLPE cable of
size up to 240 mm2 in HDPE
pipe, as per Site Condition
(excluding cost of pipe). The
detail map obtained from HDD
machine and excell sheet(hard
and soft copy) indicating the
respective depth and distance
from adjacent landmark for each
segment for HDD is must
required to be submitted. HDD to
be carried out at depth 1.5 mtrs
to 2.0 mtrs as per site conditions
and as per instruction of EIC.
Labour charge for horizontal
drilling manually without
damage to surface road at max
2.0 mtrs depth & putting of
kg/cm2 , class-4,Green color,
110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS
4984-1987(3rd revision) and BIS
certification and laying of
11KV/22KV XLPE cable of size
up to 240 mm2 size, as per Site
Condition (excluding cost of
6 9925000006 pipe). The detail map and excell Meter
sheet(hard and soft copy)
indicating the respective depth
and distance from adjacent
landmark for each segment of
cable to be submitted. Drilling to
be carried out at depth Minimum
1.2 mtrs to 2.0 mtrs as per site
conditions as per instruction of
Supply of 6.11kg/cm2 , class-
4,Green color, 110mm O.D. ,
mm thickness H.D.P.E. pipe
7 9925000007 confirms to IS 4984 and BIS Meter
certification for laying of
underground 11KV / 22KV XLPE
cable up to 240 mm2 size.
Labour work for RCC concreting
on disputed location and
repairing of damage portion of
road crossing for the work
carried out for roads crossing as
well as concreting & muffing of
ploes including all materials
Providing & fixing concrete stone
route marker of 300 mm width x
150 mm thick x 650 mm height
embedded in earth at least
mm below & 350 mm above
ground level respectively at
distance approx 50 meters along
the length of cable. The RCC
concreting (1:2:4)(all necessary
maeterials will be in bidder's
scope) of route marker is to be
9 9925000009 carried out 300 mm width x 150 No.
mm thick x 300 mm below
ground level as per instruction
of EIC. The route marker should
be with name of company with
approved yellow colour-DGVCL.
The distance from marker to
cable and cable depth with
feeder name etc., marked with
arrow sign is to be painted on
it.The route marker is to be fixed
at location near to any fixed
permanent location (not
necessary to fix exact on top of
cable) as per instruction of
Erection of D.P. (double pole)
structure using 9 / 11 Mtr. RSJ
pole with cable connection
arrangement along with fitting of
10 9925000010 necessary fabrication for 11KV No.
cable including excavation of pit
& refilling of earth as per
instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of Single pole
structure using 9 / 11 Mtr RSJ
pole with cable connection
arrangement along with fitting
ofnecessary fabrication for
11KV/22 KV cable including
excavation of pit & refilling of
earth as per instruction of EIC.
(Exclusive of concreting &
muffing of poles)
Erection of D.P. (double pole)
structure using 8.0 Mtr. PSC
pole with cable connection
arrangement along with fitting of
12 9925000012 necessary fabrication for 11KV No.
cable including excavation of pit
& refilling of earth as per
instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of Single pole
structure using 8.0 Mtr PSC
13 9925000013 pole with cable connection No.
arrangement along with fitting
ofnecessary fabrication for
11KV/22 KV cable including
excavation of pit & refilling of
earth as per instruction of EIC.
(Exclusive of concreting &
muffing of poles)
Labour charge for erecting of
11kV / 22 kV XLPE cable of size
up to 240 mm2 on DP Structure
with fixing of 02 Nos polymer
cleats on top and middle
part.Polymer cleats, nut bolts
etc. fixing material to be provided
Providing & fixing of 6.11kg/cm2
, class-4,Green color, 110mm
O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS
4984 and BIS certification on
the erected DP structure for the
mechanical protection of cable
by inserting the cable inside
15 9925000015 HDPE pipe. The HDPE pipe shall Per Job
be erected in such a way that
300mm shall be below the
ground level and the rest
mm shall be supported on the
DP Structure with 01 No
Polymer cleat.All materials
including polymer cleat and Nut
bolt to be provided by contractor.
Providing and fixing of pipe type
earthing from 80 mm dia class-B
GI pipe with pit to be filled with
salt & coke and construction of
16 9925000016 chamber as per DGVCL Drg. No. No.
dg /100 for DP and cable. The
earthing pit should be joined with
cable by G.I. strip of size 1” width
& 2 mm thick. All material GI
pipe, Coke, Salt etc will be
supplied by bidder.
Supply & fixing of heat shrink
type end terminations
17 9925000017 (outdoor) for upto 11kV 3C x No.
185 mm2 size XLPE cable as per
DGVCL technical specification
Supply & fixing of heat &
shrinkable end terminations
18 9925000018 (outdoor) for upto 22 kV 3C x No.
185 mm2 size XLPE cable as per
DGVCL technical specification)
Supply & fixing of heat shrink
type end terminations (indoor)
19 9925000019 for upto 11kV 3C x 185 mm2 No.
size XLPE cable as per DGVCL
technical specification)
Supply & fixing of heat &
shrinkable end terminations
20 9925000020 (indoor) for upto 22 kV 3C x No.
185 mm2 size XLPE cable as per
DGVCL technical specification
Supply & fixing of heat shrinkable
straight through joint for upto
21 9925000021 11kV 3C x 185 mm2 size XLPE No.
cableas per DGVCL technical
Supply & fixing of heat shrinkable
straight through joint type for
22 9925000022 upto 22kV 3C x 185 mm2 size No.
XLPE cable as per DGVCL
technical specification
Labour charge for excavation of
2100mm long x 1200mm wide x
1200 mm deep joint pits for
installation of 11kV / 22kV
Straight through joints as per
23 9925000023 instruction of engineer-in-charge No.
& covering the cable with
mm dia (Outer), thickness
mm, 1.0 meter long RCC half
round muffs & refilling same as
per instruction of EIC .
Providing and fixing of insulating
bus bar, made from 11KV/22KV
XLPE cable after removal of
semi conducting layer and
applying of PVC heat shrinkable
anti-tracking core insulating
tubing (1.1KV), on both end
terminal using Aluminium long
barrel heavy duty up to 240 sq
mm lugs, Aluminium bus
connector. Taping with PG-
clamp for bus conductor as per
drawing and as per instruction of
EIC. The Alluminium lugs and
PG clamp shall be covered with
11KV/22KV HT insulating
tapes.(11KV/22KV XLPE cable
will be in scope of DGVCL while
all other materials will be in
bidder's scope)
Testing of cable at various
points and commissioning the
feeder as per instruction of
engineer-in-charge.Test result
shall be submitted by contractor
Preparation and submission of
(six) copies, of complete layout
drawings with GIS mapping as
26 9925000026 per actual cable routing showing Set
road crossing, HDPE pipe
sleeving, jointing locations,
Providing and fixing of Sign
Board at junction point Made out
of 2 mm aluminium sheet size
rectangle, as per design, pre
treated with phosphate process
and acid etching coated with one
coat of epoxy primer and two
coats of best quality paints,
refloctrorised with Hi-Intensity
retro – reflective sheeting as per
the latest and frame fabricated
from suitable size iron angle. The
Sign Board is to be fixed on the
base prepared from channel and
bracing angles which is grouted
by means of cement concreting
of 1:2:4 for size of 300 mm dia x
800 mm height (500 mm to be
grouted in ground). The details to
be displayed on sign board will
be given by In-charge
Engineer.(a) Hi intensity Micro
prismatic Grade
Providing and fixing of Sign
Board (Danger Board) on
Distribution Transformer Centers
Made out of 2mm aluminium
28 9925000028 sheet size 300x300mm (1x1ft) as No.
per design, pre treated with
phosphate process and acid
etching coated with one coat of
epoxy primer and two coats of
best quality paints, refloctrorised
with Hi-Intensity retro-reflective
sheeting as per the latest and
frame fabricated from suitable
size iron angle. The Sign Board
(Danger Board is to be fixed at
the location as per instruction of
In-charge Engineer.
(a) Hi intensity Micro prismatic
Providing & fixing of aluminium
tag of size 250 mm (L) x 75 mm
(W) from 3 mm aluminium sheet
along with 1.0 mm dia aluminium
binding wire for fixing of
aluminium tag near end
29 9925000029 termination joint at DP structure No.
for identifyng the cable. The
details of feeder i.e. 11 / 22 KV
with feeder name shound be
punched on the tag by letter
punch of size 16 mm as per
instruction of In-charge Engineer.
Supply & fixing of heat shrink
type end terminations
30 9925000030 (outdoor) for 11kV 3C x 240 No.
mm2 size XLPE cable as per
DGVCL technical specification
Supply & fixing of heat &
shrinkable end terminations
31 9925000031 (outdoor) for 22 kV 3C x 240 No.
mm2 size XLPE cable as per
DGVCL technical specification)
Supply & fixing of heat shrink
type end terminations (indoor)
32 9925000032 for 11kV 3C x 240 mm2 size No.
XLPE cable as per DGVCL
technical specification)
Supply & fixing of heat &
shrinkable end terminations
33 9925000033 (indoor) for 22 kV 3C x 240 No.
mm2 size XLPE cable as per
DGVCL technical specification
Supply & fixing of heat shrinkable
straight through joint for 11kV
34 9925000034 3C x 240 mm2 size XLPE No.
cableas per DGVCL technical
Supply & fixing of heat shrinkable
straight through joint type for
35 9925000035 22kV 3C x 240 mm2 size XLPE No.
cable as per DGVCL technical
Installation, Testing and
commissioning of 11 KV,630 A
SCADA Compatible, RRL type-
3 Way RMU including Two
numbers of earthings as per
Drawing (material is in bidder's
scope) and as per DGVCL
Technical specification.
Installation, Testing and
commissioning of 11 KV,630 A
SCADA Compatible, RRLL type-
4 Way RMU including Two
numbers of earthings as per
Drawing (material is in bidder's
scope) and as per DGVCL
Technical specification.
Installation, Testing and
commissioning of 22KV,630 A
SCADA Compatible, RRL type-3
Way, RMU including Two
numbers of earthings as per
Drawing (material is in bidder's
scope) and as per DGVCL
Technical specification.
Installation, Testing and
commissioning of 22KV,630 A
SCADA Compatible, RRLL type-
4 Way, RMU including Two
numbers of earthings as per
Drawing (material is in bidder's
scope) and as per DGVCL
Technical specification.
Construction of plinth for
11KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One
number of Breaker) Ring Main
40 9925000042 Unit as per DGVCL's technical No.
specification mentioned in
drawing no: Drg. 11kv-01. All
required material will be supplied
Construction of plinth for
11KV, RRLL type- 4 Way (i.e
Two numbers of Isolator & Two
number of Breaker)Ring Main
41 9925000043 Unit as per DGVCL's technical No.
specification mentioned in
drawing no:Drg. 11kv-02.All
required material will be supplied
Construction of plinth for
22KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One
number of Breaker) Ring Main
42 9925000044 Unit as per DGVCL's technical No.
specification mentioned in
drawing no: Drg. 22kv-01. All
required material will be supplied
Construction of plinth for
22KV, RRLL type- 4 Way (i.e
Two numbers of Isolator & Two
number of Breaker)Ring Main
43 9925000045 Unit as per DGVCL's technical No.
specification mentioned in
drawing no:Drg. 22kv-02.All
required material will be supplied
Modifications e.g.Providing and
fixing of Terminal protectors i.e.
Re-use able boot (HT Side
11/22KV, LT Side 1.1KV)
including 11/22 KV insulating
taps and L.T.(1.1 KV) insulating
taps ,Busbar, Tapping from Bus
Bar (11/22 KV XLPE cable)
through P.G. Clamp for H.T.
Jumper to D.O. Fuse to bushings
of Transformer Center,
providing & Fixing of jumper and
providing & fixing of Heat
Shrinkable Anti Tracking Core
Insulating Tubing (Insulation
44 9925000046 Level 11/22 KV) in H.T. jumper , No.
Clamping arrangement of cable
support frame on both side of
existing Over Head type
Distribution Transformer to utilize
in Under Ground cable network
as per drawing & as per
instruction of Engineer incharge.
All live parts i.e. PG-Clamp,
connections of D.O.fuses, HT
bushings etc . shall be covered
with fixinng of 11/22 KV HT
insulating tapes. ( 11/22 KV
XLPE cable will be in scope of
DGVCL while all other materials
will be in bidder's scope ) .
Laying of any size of 11/ 22 KV Per
45 9925000047 XLPE /PILC Cable in redaymade Cable
trench or in open space Per Mtr
Labour charges for Lying of O/H
XLPE cable pole to pole
Supply of 150 mm dia (Inner),
47 9925000064 thickness 25 mm, 1.0 meter long No.
RCC half round pipe
Total of schedule B1, B2& B3
(+)_______%Above, (-)_______%Below, Rate to
Net Total of Schedule ‘B1, B2& B3:
Amount in Words: (Twenty-Five Lacks Only)
1. Whatever Steel Material removed after replacement should be credited to Store.
2. The rates are inclusive of PF & Work Contract Tax & excluding of GST.
3. Contractor has to carry out work under Dharasana Sub-Division under Valsad-
Rural Division.
4. DGVCL will provide 1ph & 3ph LT Ariel Bunch Cable 11/22kv HT ABC with necessary
accessories to the contractor.
5. The rates are inclusive of dismantling charges of existing bare conductor and
crediting in to store & dismantling of service lines from LT bare conductor and to
provide service connections on ABC by insulated pierce connectors through service
connection box.
6. The contractor has to collect all the required materials from DGVCL store as well as
credit the dismantle material to the DGVCL store at their cost.
1. DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the contractor.
2. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding
rods confirming to the relevent ISI specification and as directed by Engineer in charge.
3. Necessary electricity connection for fabrictated items shall be provided by DGVCL on
payment of required charge for connection & electricity bill of the same shall be paid by the
4. All the rates are inclusive of PF and Exclusive of GST applicable time to time.
5. All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles &
steel fabricated materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the
RSJ poles & steel fabricated materials of RSJ/PSC poles.
Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint)
is to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
Executive Engineer (O&M)
Valsad Rural Division.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2. Bid Document.pdf
4. Detail Technical Specification.pdf
Amend an Arbitration Clause.pdf
GENERAL TERMS and CONDITIONS.pdf
Letter to All DISCOMs for Ratified Common UG Tender Conditions.pdf
TECHNICAL SPECIFICATIONS FOR THE WORK.pdf
1. Schedule A.pdf
Schedule-B.pdf
TECHNICAL BID.pdf
Notice Inviting Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .