| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹23.1 L+₹1.2 L (5.46%)Rejected-Finance | L2 | Rejected-Finance Not Meeting eligibility criteria | |
| 3 | L3₹23.9 L+₹2.0 L (9.13%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | L3 | Rejected-Finance Not Meeting eligibility criteria | |
| 4 | L4₹24.2 L+₹2.3 L (10.7%)Rejected-Finance | L4 | Rejected-Finance Not Meeting eligibility criteria | |
| 5 | L5₹29.6 L+₹7.7 L (35.1%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-Finance Not Meeting eligibility criteria |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Aug 2022, 6:00 pmClosed
Shri T Rajasekharam,IDSE
HQ Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REWIRING AND REPAIR TO FITTING OF MD OTM ACCN OF SARVTRA NAGAR NEPAL LINE AND INDRAYANI DARSHAN UNDER GE DEHU ROAD
2022_MES_530902_4
84080/DR/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Dehu Road
Please ref tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Dehu Road
₹80,000
5 Jan 2023
12 Aug 2022
31 Aug 2022
12 Aug 2022
30 Aug 2022
18 Aug 2022
12 Aug 2022 - 23 Aug 2022
Amount
Taking down carefully copper / aluminium point wiring (Light, fan, socket or power socket) complete including fixtures and fittings such as switches , ceiling roses, pendants, regulators, socket light fitting and making good disturbed surfaces of walls, floors with cement mortal and white/colour wash to match with existing surfaces etc complete all as specfication and directed by Engineer-in-Charge .
Taking down unserviceable Main switch, MCB DB TPN, MCB DB, TPN/SPN/SP etc. and making good disturbed surfaces of walls complete all as specfication and directed by Engineer-in-Charge .
M & L for Point wiring complete with and including 1.5 sq. mm ( nominal area) single core multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade FRLSH, I S I marked drawn through PVC casing caping suitable size with accessories such as bend ,tees, junction boxes etc. incl. 1.5 Sqmm PVC insulated and unsheathed multi stranded copper conductor as earth wire including PVC premoulded switch board ISI marked suitable size for housing switch, socket and fan regulators etc complete and making good the disturbed surfaces of wall by cement patch all and matching the surface to the existing finising colour all as specified and directed for the following :- (a) One light point controlled by one one way switch.
- do same as Item no.3 above but One Fan point controlled by one one way switch.
- do - same as Item no.3 above butOne light point controlled by two 2 way switches.
- do - same as Item no.3 above but One bell point controlled by one bell switch.
- do - same as Item no.3 above but One 5 pin 5 Amps socket outlet on the same board with other switch controlled.
- do same as Item no.3 above but One 5 pin 6 Amp switch socket outlet on the independent board.
- do - same as Item no.3 above but wiring with 2.5 sq. mm multy stranded copper conductor PVC insulated but unsheathed FRLS cable for 5 pin 15 Amps multi purpose socket outlet.including 2.5 Sqmm PVC insulated and unsheathed single core copper conductor cable as a earth wire to common earth connection to earth duly.
M & L for concealed point wiring for light/call bell/fan/exhaust fan point with cables 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable 1100 volts grade FRLSH, confirming to IS - 694 drawn into and incl PVC concealed conduit /PVC surface conduit with pressed steel terminal boxes of adequate size with 3 mm thick plastic laminated sheet , cover of adequate size for light/fan/Exhaust fan/ call bell controlled by one switch incl 1.5 Sqmm copper conductor cable multistrand PVC insulated and unsheathed as earth wire to common earth dolly complete all as specified.Note- Item rate includes making groves/ trenches in wall and making good surface. (a) One light point controlled by one one way switch.
- do - same as Item no.10 above but One Fan point controlled by one one way switch.
- do - same as Item no.10 above but One light point controlled by two 2 way switches.
- do - same as Item no.10 above but One bell point controlled by one bell switch.
- do - same as Item no.10 above but One 5 pin 5 Amps socket outlet on the same board with other switch controlled.
- do - same as Item no.10 above but One 5 pin 6 Amp switch socket outlet on the independent board.
- do - same as Item no.10 above but wiring with 2.5 sq. mm multy stranded copper conductor PVC insulated but unsheathed FRLS cable for 5 pin 15 Amps multi purpose socket outlet.including 2.5 Sqmm PVC insulated and unsheathed single core copper conductor cable as a earth wire to common earth connection to earth duly. Make for Item No.3 to 16- Make for cable : Havells/Finolex/ Nicco/Plaza/ Anchor/ Polycab/RPG/Gloster/RR Kabel/KEL Make for PVC Conduit : (i) Anchor (ii) Modi (iii) Pressfit (iv) Precision (v) Astral Make for Casing caping : Precision / Modi / Presto Plast / Supreme/ Polycab/ Plaza/ Pressfit
S & F in repair switch piano flush type ,single pole one way 5 Amp complete all as specfication and directed by Engineer-in-Charge .
S & F in repair of Bell push, flush type, 5 amp complete all as specfication and directed by Engineer-in-Charge .
S & F in repair ding dong electric calling bell with new one 240V, 50Hz, AC complete all as specfication and directed by Engineer-in-Charge .
S & F in repair socket outlet 2-in-1, 3 pin 5 Amps complete all as specfication and directed by Engineer-in-Charge .
S & F in repair switch socket combination 2-in-1, 5 Amps flush type complete all as specfication and directed by Engineer-in-Charge .
S & F in repair socket outlet 2-in-1, 5 pin 15 Amps Flush type complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Switch 15 Amps Flush type, ISI marked complete all as specfication and directed by Engineer-in-Charge .
S & F in repair ceiling rose surfase type ISI marked 65 x 50 mm three terminals type complete all as specfication and directed by Engineer-in-Charge .
S & F in repair for White Angle lamp holder, ISI marked with metal ring Insulated body with back plate for batten fitting complete all as specfication and directed by Engineer-in-Charge .
S & F in repair step type electronic regulator of ceiling fan should be capacitor based hum free ISI marked 230 v 100 watt complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular switch 1 way 6A , 230 V, 1 Module single pole complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular switch 2 way 6A , 230 V, 1 Module single pole complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular switch 1 way 16 A, 230 V, 1 Module single pole complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular calling bell switch 6 A, 230 V, 1 Module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular socket outlet 2/3 pin , 6 Amps, 2 module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular switch socket combination 2 in 1, 5 Amps Flush type complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular socket outlet 5/6 pin , 6/16 Amps, 2 module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular fan regulator , 120 W , 2 Module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular white cover plate with frame 1 module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular white cover plate with frame 3 module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular white cover plate with frame 6 module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair Modular white cover plate with frame 8 module complete all as specfication and directed by Engineer-in-Charge .
S & F in repair of PVC board of size 10X8 cm with arrangement to accommodate switch/socket/regulator complete all as specfication and directed by Engineer-in-Charge .
S & F in repair of PVC board of size 7X4 cm with arrangement to accommodate switch/socket/regulator complete all as specfication and directed by Engineer-in-Charge .
S & F in repair of PVC board of size 4X4 cm with arrangement to accommodate switch/socket/regulator complete all as specfication and directed by Engineer-in-Charge . Make for Item No. 17 to 41- (a) Anchor Penta (b) Legrand (c) Crabtree (d) Havells (e) Indo Asian (f) Polycab (g) Leader
S & F in repair of PVC Block of size 75 mm for fluroscent fittings in shape of round/ Square complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement MCB SP 6 to 40 Amps 240 volts 50 Hz having 'B' Curve complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement MCB SPN 6 to 40 Amps 240 volts 50 Hz having 'B' Curve complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement MCB SPN 63 amps, AC, 240V, 50 Hz,having 'B' Curve complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement MCB TPN 63 Amps 415 volts having 'B' Curve complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement MCB TPN 100 Amps 415 volts having 'B' Curve complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement MCB 4 pole 63 Amps 415 volts having 'B' Curve complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement MCB 4 pole 100 Amps 415 volts having 'B' Curve complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement sheet metal enclosures double door distribution board IP 20- Ik- 08 factory made duly painted 12 way SPN and neutral 240 v with 200 amps fully insulated rated copper bus bar.
S & F in replacement sheet metal enclosures double door distribution board IP 20- Ik- 08 factory made duly painted 8 way SPN and neutral 240 v with 200 amps fully insulated rated copper bus bar complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement distribution board sheet metal enclosures for single door factory made duly painted 4 way SPN 240 V , suitable for fixing MCB /Isolators all as specified and complete all as specfication and directed by Engineer-in-Charge .
S & F in replacement vertical distribution board in sheet metal enclosure with double door factory made 4 way TPN,415 Volt IP- 54 IK-09 suitable for fixing MCCB TP as main incoming duly painted all as specified with insulated copper bus bar 200 amps insulated neutral bar and cable ties for cable management, corner shield for better protection , masking sheet and pan assembly for easy installation complete all as specfication and directed by Engineer-in-Charge. Make for Item No.43 to 53 : (i) Larsen & Toubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric (ix) Standard (x) HPL
S & F in replacement of 4 feet 18W linear aluminium LED Batten basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and electric coneection with suitable copper wire complete all as specified. Cat Part No : LHEXBTP7IN1W018 of Havells or equivalent of Philips, Bajaj, Crampton and HPL.
S & F in replacement of 4 feet 20W linear aluminium LED Batten professional CW 6500K cool white complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size. Cat Part No : LHEXACP7IN1W020 of Havells or equivalent of Philips,Bajaj, Crampton, Havells and HPL.
M & L in replacement of 4 feet 22W linear aluminium LED Batten professional CW 6500K cool white complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size complete with acessories. Cat Part No : LHEXACP7IN1S022 of Havells or equivalent of Philips,Bajaj, Crampton, Havells and HPL.
M & L in replacement of 2 feet 9/10W linear aluminium LED Batten with white acrylic cover complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size.Cat Part No : LHEXBLP7IN1W009 of Havells or equivalent of Philips,Bajaj, Crampton, Havells and HPL.
M & L in replacement 15 Watt LED bulb high power low heating superflux LEDs, 100 lumen/ watt, 120-270 V AC inbuilt electronic driver, complete all as specified. Make : Havells/Philips/ Bajaj/crampton/HPL
S & F in replacement of 10W Surface mounted downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency all as specified & directed. Make : Cat Part No INTEGRANEOSURFA CEDLS10WLED840S of Havells or equivalent of Philips, Bajaj HPL
S & F in replacement of 12 W Star Slim LED Panel light with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency all as specified & directed. Make- Cat No LHEBADP5IZ1W012 of Havells or equivalent of Philips, Bajaj, HPL.
S & F in replacement of 28 W Recess Mounting Pluto Neo Panel 2x2 down light environment friendly, new generation aesthetically designed, ultra modern with high brightness SMD LEDS as light source, suitable for armtrong/Grid ceiling all as specified & directed. Make : Cat Part No PLUTONE02X2PLR28WLED857S of Havells or equivalent of Philips, Bajaj, HPL.
Taking down carefully old u/s submain wiring of any type and making good the disturbed surface of walls /floor complete all as specfication and directed by Engineer-in-Charge.
M & L for sub main wiring with two runs of single core PVC insulated multistranded unsheated FRLS cable 4.0 sqmm (nominal area) 1100 Volts grade copper conductor with one run of 4.0 sqmm PVC insulated unsheated single core copper conductor multistrand 1100 volt grade as a earth wire drawan into and including PVC casing caping with accessories of suitable size as required and all as directed by engr-in-charge
M & L for sub main wiring with two runs of single core PVC insulated multistranded unsheated FRLS cable 4.0 sqmm (nominal area) 1100 Volts grade copper conductor with one run of 4.0 sqmm PVC insulated unsheated single core copper conductor multistrand 1100 volt grade as a earth wire drawan into and including PVC concealed conduit with accessories of suitable size as required and all as directed by engr-in-charge.
M & L for sub main wiring with two runs of single core PVC insulated multistranded unsheated FRLS cable 6.0 sqmm (nominal area) 1100 Volts grade copper conductor with one run of 6.0 sqmm PVC insulated unsheated single core copper conductor multistrand 1100 volt grade as a earth wire drawan into and including PVC casing caping with accessories of suitable size as required and all as directed by engr-in-charge. Make for Item No. 63 to 65 : Havells / Finolex / Nicco / Plaza / Anchor / Polycab / RPG/ GLOSTER / RR Kabel/ KEI
M & L for Earthing complete with Galvanised steel earth plate electrode 600x 600x 6 mm thick, buried directly in ground (earth pit not less than 2.75 deep Below ground level with top age of the plate not less tha 1.50M below ground level connected to galvanised earth lead wire 4mm dia (uoto 7.5mt) by means of bolts, nuts check nuts and washer of galvanised iron or steel connected to eartthing test point all as specfied incl excavation and earth work and disposal of surplus soil incl 15 mm Gl tubing mrdium grade and necessary fitting for protection of lead wire incl laying of charchol dust and common salt PCC (1.3:6) type B-O using 12.5 mm garded stone aggregate reinforced with 6mm dia round bar @15mm C/C both ways with MS handle 12mm dia, plastering 15mm Thick CM(1:6) internally and upto 150mm below ground level extermally, PGI funnel with 20mm dia GI pipe med grade for watering and wire mesg complete all as specfied and shown on electrical plate No3 of SSR part tI 2009 and connected to earth test incl testing complete all as specfication and directed by Engineer-in-Charge .
Taking down exhaust fan of any make dismantling/open fan taking out burnt winding and rewinding the same with super enamelled copper winding wire suitable guage and after cutting the old burnt winding and cleaning the slots including varnishing and replacement of flexible cable 23/0.0076 mm to the required length including making connection and testing complete and re-fixing in same position all as specified and directed by Engr-in-charge.
All as per item no 67 above but exhaust fan 275 to 300 mm sweep
All as per item no 67above but exhaust fan 350 to 450 mm sweep
All as per item no 67 above but wall mounted fan 400 mm sweep
M & L in repair Fan capacitor 2.5 mfd for ceiling fan 1200 mm complete all as specfication and directed by Engineer-in-Charge .
M & L in repair Fan capacitor 4 mfd for exhaust fan all as specified and as directed by Engr-in-Charge. Make for Item No.71 & 72 : Amcap, Epson
S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Make : Bajaj/ Havells/ Crompton Greaves/ Orient
Supply and laying in repair old UNSV UG Cable and Laying only cable heavy duty 1100 volts grade with strandad aluminum conducter of Size 10 Sqmm x 2 Core complete all as specfication and directed by Engineer-in-Charge . Note : Cable will be issued free for fixing Schedule "B"
All as per item no 74 above but of size 16 Sqmm x 2 Core
All as per item no 74 above but of size 10 Sqmm x 4 Core
All as per item no 74 above but of size 16 Sqmm x 4 Core
All as per item no 74 above but of size 25 Sqmm x 3.5 Core
All as per item no 74 above but of size 50 sq mm x 3.5 core
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in soft /loose soil omplete all as specfication and directed by Engineer-in-Charge .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in Hard / dense soil omplete all as specfication and directed by Engineer-in-Charge .
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation complete all as specified and directed by Engineer -in-Charge.
M & L for HDPE 50 mm dia pipe for UG cable protection through out from panel to all as specified and directed by Engineer-in-Charge. Make : (a) Rex polyextrusion Ltd (b) Finolex (c) Prince Pipes and fittings Ltd (d) Kisan ( Supreme (f) JAIN IRRIGATION SYS (g) Astral
PREETI ENTERPRISES
Shri Sai Electricals
S.M.Sales Corporation
metro electrical services
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .