Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.1 LAccepted-AOC KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹100.0 L+₹5.8 L (6.18%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | L3₹1.0 Cr+₹6.8 L (7.24%)Rejected-Finance | L3 | Rejected-Finance Highest | |
| 4 | L4₹1.1 Cr+₹13.9 L (14.7%)Rejected-Finance 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance Highest |
Tender Value
₹79.5 L
EMD Value
₹1.6 L
Closing Date
30 Nov 2021, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Four Lanning of NH-72 Ambala Naraingarh road from Km. 1.00 to Km. 3.500) (Baldev Nagar Chowk to Naraingarh Road) in Ambala District (Pdg. Decorative Poles with LED Fittings).
2021_HRY_196150_1
PWD/Elect-KNL/Elect-AMB/110198
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.6 L
Yes
22 Apr 2022
17 Nov 2021
1 Dec 2021
17 Nov 2021
30 Nov 2021
17 Nov 2021
Amount
Wire 1.5 Sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable. EL003
10 Sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable. EL007
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp HSR No. 23.22.1.9
MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP HSR No. 23.22.2.1
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.9
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR No. 23.22.5.1
6 amp. to 32 amp MCB's TRIPLE POLE HSR No. 23.22.5.5
Supply and election of Goodridge Almirante type M.S. pedestal made of 50 mm *50 mm * 6 mm angle Iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and looking arrangement with the Godrich type handle including round bars. The to covering should have a downward overhang of 75 mm on all sides of pedestal, having two sets of water proof ventilation holes of suitable size on the sides, at top and bottom, each set containing four No’s. holes to discharge the heat produced by suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embedded upto the entire depth in 1:2:4 cement concrete block, projected 75 mm all around the pedestal and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in charge of the work. M.S. pedestal of size 750 mm wide, 900 mm high, 300 mm deep and bottom totally open , duly embedded in cement concrete block of size 900 mm*450 mm*200 mm above ground level , having a base of size 1050 mm* 600 mm* 250 mm below ground level. HSR No. 23.27.2
CHAPTER 24.0 - CABLE LAYING AND STREET LIGHTING EARTHING AND LIGHTENING ARRESTOR Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. HSR No. 24.1.1
Extra for using salt and char coal/coke for pipe earth electrode as required. HSR No. 24.1.2
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. HSR No. 24.1.11
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop carthing as required. HSR No. 24.1.13
Laying of underground cable in pipe /existing open/closed tench tc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core HSR No. 24.2.4.2
Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 1.5 sqmm HSR No. 24.2.6.1
10 sqmm HSR No. 24.2.6.5
Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core HSR No. 24.2.7.2
25 sqmm to 50 sqmm Cable 2 to 4 Core HSR No. 24.2.7.3
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm HSR No. 24.2.8.4
35 sqmm HSR No. 24.2.8.6
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia HSR No. 24.5.2.3
RCC FOUNDATIONS FOR OCTAGONAL POLES Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 70 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 8m high pole HSR No. 24.8.6
Digging & refilling of trench 30 cm wide below ground level for erection of pipe/cable (up depth of 1 Mtr. Underground cable excluding the cost of cable/pipe complete in all respect. HSR No. 24.10.1
S/Eof under ground cable ,loose in existing pipe or trenches complete with necessary connections . Supply & Erection of 16 Sq. mm 4 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, make Grandlay complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Plaza/Grandlay. NS-1
Supply & Erection of 35 Sq. mm 3.5 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, make Grandlay complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Plaza/Grandlay. NS-2
SITC of 8 MTR high Decorative Pole , having lower section OD 114 MM and top Section 76 MM Dia , made of GI Pipe as per IS 1239, Square mild Steel plate should be joined with the pole at the bottom through welded joints with 4 no circular holes suitaible for M12 Bolts . The pole must have a decorative casting at the bottom and at the Middle sectiuon, The pole should have window cutting 300mm x 70 mm weather proof flush door and locking arrangement for housing of the pole to accomodate electrical accessories (Bakelite plate and connector ) for power supply connection . The window cover is fitted with allen screws to the pole and is provided in bottom section of the pole, the body of the pole shall be machined and polished properly to give it a smooth surface as per IS2629 and IS 2633. The pole shall have a decorative casting at the top of the shaft . The decorative pole shall be duly pre-treated and painted UV resistant coating in approved color shade. The coating Shoukd have a DFT of 80-90 Microns, Entire Unit Shall be given an extensive three stage treatment with PU based etch primer , Zinc phosphate primer and PU paint of approoved color and prescribed for such surface to make it absolutely rust and corrosin proof. The pole Should have double arm decorative bracket with U Shape bracket , each bracket arm lenght of 1000mm and dia for hanging the fitting should be 48MM with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make as per approved make list. NS-3
SITC of 120 Watt IP 66 , IK07 LED hanging decorative Street light in round shape suitauble for U shaped Brackets with viewing angle of 120 degree for better uniformity , with injection moulded clear Polycarbonate Cover , pressure diecast heat sink , with individual PC lens for better uniformity , built in potted electronic driver with THD<10%, built in surge protection upto 10 KV and other safety test as per IS 15885 part-2/sec13, operating voltage 140-270 V , Life of Led 50000 burning hrs , operating temperature of 50 degree celsius.The fixture should have system efficacy of minimum 90 Lumens /watt. The CCT of the Fixture Warm white with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make as per approved make list. NS-4
S/E of 63 amp. 3 Pole/230V Astronomical automatic time switch of Indo Asian make Cat No. TL065ASO alongwith contractor of required capacity movement controlled by precisaty quartz osciliation operation on main supply of continue to run on built in rechageable nicket cadium cell for 150 hours in the evnt of power failure including cost of contractor complete in all respect upto the entire satisfaction of Engineer-in-charge of the work. NS-5
Baliyan Electrical Works
M/S PANJETA ELECTRICALS
J.B.S.Electrical Co.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .