| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.1 L+₹3.9 L (16.2%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹41.9 L+₹17.7 L (73.2%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 |
Tender Value
₹41.6 L
EMD Value
₹83,160
Closing Date
8 Sept 2023, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
REPAIR, MAINTENANCE OF TRANSFORMER, HT VCBs, LT PANELS SWITCHGEARS, SECURITY LIGHTS AND OTHER MISC WORKS AT SLIPWAY AND DEGAUSSING BAY AT SBC COMPLEX UNDER NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2023_MES_613268_1
8825/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM, Visakhapatnam
₹83,160
Yes
16 Oct 2023
11 Aug 2023
15 Sept 2023
11 Aug 2023
8 Sept 2023
25 Aug 2023
Amount
Attending to transformer complaint 24 hrs of capacity upto 750 KVA tripping including meggaring of the cables and checking the physical condition of the transformer and assessing the physical condition and, checking oil level, conducting electrical LT testing like, measuring of IR values, ratio test, magnetic balance test, oil BDV test to assess the healthness of the windigs and if found statiafactory, then connections of the cable terminations and make arrange for charging the transformer.If transformer is found faulty, then recommend for the further repair/rewinding works to be carried out to put back the transformer into service.
Note :- (a) New transformer oil to be bought in company sealed ISI marked container with test certificate (b) Filtration /dehydration of transformer oil shall be carried out at the location where transformer is installed and required pipe connection from filter machine to transformer shall be made and rate shall be inclusive of quoted rate. (c) Necessary filter/dehydration plant having pressure gauge, hour meter, temperaturature gauge to be brought at site by contractor and to be kept permanently inside ND (V) till completion of work and rate deemed to be included in the quoted rate. In any condition, in-out of the filter machine during the progress of the work will not be allowed. (d) Transformer oil test report before and after dehydration/filtration shall be submitted duly authenticated by authorised person .
M&L for dismantling of HT/LT epoxy insulator after dismantling cables at outside & transformer terminal at inside of transformer for rectification of oil leakage through insulator or for replacement of insulator or for replacement of brass stud by taking out unsv gusket from inside & outside bushing and replacement with RC 70 C rubberised cork sheet gusket of proper thickness, reassemble old/new insulator, brass stud, HT/LT cable connection, HT/LT transformer inside terminal connection to original position all as specified and directed. Note: (a) Opening of top cover measured separately (b) Epoxy insulator HT/LT & Brush stud with nuts & bolts required new shall be measured as supply only. (c) Silicon sheet gusket shall be inclusive of quoted rate.
M & L for filtration/dehydration transformer oil of transformer voltage grade 11/0.415 KV, capacity 200 KVA to 3000 KVA indoor/outdoor type, floor mounted in situ till achieve dielectric strength minimum 40 KV at 4mm gap all as specified and directed.
M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and directed. Make – GULF/Castrol/ HP /IOC /Savita /Power.
M&L for complete painting of transformer outer surface in situ/wksp with one coat of synthetic enamel paint using sprayer for transformer capacity 500-1600 KVA after prliminary preparation of old painted surface . Note :- (i) During process of painting, transformer will be under shut down for the period and the rate deemed to be included for running the sprayer machine with alternative arrangement by contractor. (ii) After completion of painting HT/LT outdoor bushing, cable termination joint, Oil inspection glass, meters and name plates to be made clean using volatile cleanner.
M&L for testing of transformer 500 KVA to 3000 KVA, 11/0.415 KV at various location by following test for HV & LV complete all as specified and directed. (a) Insulation Registance (b) Winding resistance (c) Turn ratio (d) Magnetic balance, (e) Oil BD value (Note: Required testing equipment for transformer test shall be brought by the contractor and rate shall be inclusive of quoted rate)
M & L for replacement of silica gel grains in the breather assembly of transformer complete all as specified and directed.
M & L for replacement of breather assembly made with polycarbonate base and clear acylic glass of size to accommodate 1.0 kg of silica gel for transformer complete all as specified and directed.
M & L for replacement of transformer temperature gauge dial type having temp range 0 to minimum 120 degree celcius complete all as specified and directed.
M & L for replacement of transformer explosion vent gasket complete all as specified and directed.
Supply only brass stud with accessories suitable for HT 11000 volts grade insulator with con & rubber washer, double Brass nuts & brass washer at both end of stud for Tr cap 750 KVA complete all as specified and directed.
Supply only brass stud suitable for LT 1100 volts grade insulator with con & rubber washer, double Brass nuts & brass washer at both end of stud for Transfomrer capacity 750 KVA complete all as specified and directed.
Taking out manually defective transformer of capacity 750 KVA from its position upto road n. exc 50 mtr and transportation by vehicle to workshop n. exc 25 KM and reinstallation at original position after repair including all cable/earth connections all as specified and directed. Note:- a) Rates for dismentling of HT/LT cable & earthing and reconnection after installation deemed to be included in the quoted rate, (b) Necessary crane for lifting of transformer and vehicle for transportation shall be arranged by the contractor and deemed to be included in the quoted rate.
M & L for core & chamber cleaning by lifting up carefully transformer core after dismentling carefully terminal connections from core to HT/LT bushings, tap changer assy, drainout all oil and keeping in clean container, flushing with transformer oil for cleaning of core/winding, cleaning of transformer tank by removing all sludges, re-install core with tapchanger, all connection complete all as specified and directed for the transformer 750 KVA, 11/0.415 KV transformer complete all as specified and directed. Note:- (a) Opening of top cover, nuts, bolts & washers, HT/LT busings, brash rods, de-hydration/topping up of oil as required, shall be mesured separately under appropriate item, (b) The work shall be carried out inside dockyard, (c) Transformer oil used for flushing shall be retained and re-used vide item No-1, (d) Empty transformer oil containers shall be arranged by the contractor and inclusive of quoted rate.
M & L for rewinding of HV/LV coil after lifting up carefully transformer core after dismentling carefully terminal connections from winding to tap changer assy and to HT/LT bushings, drainout all oil and keeping in clean container, dismentling core, dismentling all HT & LT coils from core for rewinding, testing and reassembling complete with HT/LT coils to core, required necessary numax paper insulation, insulating press board, precompressed board off sizes, vernishing, heating to achive insulation level not less than 1000 megaohms at both HT & LT side, core at transformer chamber, tap changer assy, terminal connection, refilling of oil complete for the transformer capacity 500 to 3000 KVA, 11/0.415 KV transformer all as specified and directed. Note:- Opening of top cover, Rewinding of HT/LT coils, transformer oil, nuts, bolts & washers, HT/LT busings, required new mesured separately under appropriate item
M&L for rewinding of HT coils suitable for 11000 volts grade with new DPC/super enamelled copper wire having Class-F insulation as per existing size and turns for capacity of transformer 200-3000 KVA complete all as specified and directed.
M&L for rewinding of LT coils suitable for 1100 volts grade with new DPC /super enamelled copper strip having Class-F insulation as per existing size and turns for capacity of transformer 200-3000 KVA all as specified and directed.
M&L for rewinding of LT coils suitable for 1100 volts grade with existing DPC /super enamelled copper strip having Class-F insulation as per existing turns for capacity of transformer 200-3000 KVA all as specified and directed.
M&L for replacement of off load Tap changer assy incl rotating wheel having 7 position of transformer including dismentling and taking out old unserviceable one and dismentling all winding terminal connections and reconnection after replecement complete upto transformer cap 3000 KVA 11/0.415 KV all as specified and directed.
Overhauling and replacement of minor spares of 400 Amp to 800 Amp 11 KV HT breakers for proper functionalling and servicing/ repairs, replacement of defective worn out components and refixing back including testing comprising the following:- (a) Disconnecting form socket contacts, cleaning and adjustment of gap, replacement of rings etc. (b) Checking the brekaer bushing of bus bar and circuit side, inspection/ servicing of internal surface for any arcing/ tracks. (c) Checking the epoxy body completely for any cracks, any sign of arcs/ tracks, cleaning thorougly with CTC including applying bectrol red varnish if necessary. (d) Checking the drive rod & drive beam insulator assembly and inspect for chocking/ tracks/ arcing. (f) Checking the condition of the spring charging motor along with gear box including servicing the motor & replacement of motor bearings if required. (g) Checking/ servicing of ratchet wheel assembly, driving and charging parts. (h) Chekcing the auxiliary switch, its contacts for proper functional operation. (i) Checking & servicing of raising/ lowering mechanisim and its locking system for proper functioning. (j) Checking & servicing of shutter assembly for its automatic opening/ closing
(k) Testing of VCB to confirm healthiness up to satisfactory results before reinserting in VCB panel. (i) Insulation Resistance test with 5000V digital insulation tester. (ii) Timing test at 70%, 100%, of rated control voltage. (iii) Contact Resistance Measurement test. (iv) AC Hi voltage test (if required) (l) Replace both the closing & tripping buffers and if required adjust VCB timing up to satisfactory limit. Note :- (i) Test results should be submitted to Engineer in-Charge to keep on record duly signed by all concerened complete all as specified and as directed. Submission of latest and valid calibration certifcate of all used testing kits and equipment from reputed laboratories approved by NABL. Calibration should be carried out through authorised CEIG Licenced agency only. (ii) Any abnormality found during testing, same shall be brought to the notice of Engineer in -Charge. (iii) The items like testing equipment, nuts, bolts, spring washers, petroleum jelly, CTC etc. Required to put the breaker in serviceable condition shall be supplied by the contractor and rate shall be deemed to be included in the unit rate quoted.
M&L for de-carbonising/ cleaning maintenance of 11KV cubicle type VCB panels consisting of bus bar and circuit chamber, metering chamber, CTs, PTs and relay chamber all as specified below:- (i) Checking the bus bar and circuit spouts, cleaning with CTC and applying bectrol red varnish to the surface of the bus bar and circuit spouts. (ii) Checking the CTs/PTs for any arcing/ tracks, cleaning and applying one coat of varnish/ bectrol red. (iii) Cleaning of metering and relay chamber, checking of burnt wires if any, tightening of all connections to arrest the loose contacts. (iv) Applying mon - plast compound at bus bar joints after tightening all joints/ connections.
Supply only Resin Cast CT dual core, CT ratio - 100/50/5A-5A for 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make- Kappa/ Esun/ Pragati/ Schneider
M&L for mainteanance / servicing of PT unit 11KV/110V by disconnecting and taking out from panel mojnted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of Busbar connections, resin cast PTs using hot blower, CTC solution, applying backtol (Red) solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
Supply and fix space heater, 230V, 100 Watt inside cable chamber including necessary connection, testing complete all as specified and directed. Make: Schneider, Part No. EHT-A-AA000-001
Supply and fix including dismantling taking out unserviceable thermostat for space heater for 800 A to 1600 A Schneider make 11 KV VCB compete all as specified and directed. Make: Schneider only, Part No ETH-E-B000-001
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 630A to 800A Schneider make 11 KV VCB complete all as specified and as directed. Make-Schneider only, Part No- MVIJ00098-01
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) for 630A to 800A Schneider make 11 KV VCB complete all as specified and as directed. Make-Schneider only, Part No- MVIJ00056-01
Supply and fix including dismantling taking out unserviceable single (Read-Blue) phase busbar spout suitable for 630A to 800A VCB complete all as specified and as directed. Make-Schneider only, Part No- MEP-39-32185
Supply and fix including dismantling taking out unserviceable single (Y) phase busbar spout for 630A to 800A 11 KV VCB complete all as specified and as directed. Make :- Schneider Model No. MEP-39-32186
Supply and fix including dismantling taking out unserviceable CT Spout suitable for VCB 630A to 800A complete all as specified and as directed. Make :- Schneider Model No MEP-39-32187
Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unsv one complete all as specified and as directed.. Make :- Schneider, Part No- ECO39SN134900FN
Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unsv one complete all as specified and as directed.. Make :- Schneider, Part No- ECO39SN134100FN
Supply and fix including dismantling taking out unserviceable Breaker Wheel - CAST IRON, For 630A to 800A 11 KV VCB complete all as specified and as directed. Make :- Schneider only, Part No-MVIA00025-01
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC for 630A to 800A 11 KV VCB complete all as specified and as directed. Make :- Schneider only, Part No-MVIJOO157-02
Supply and fix including dismantling taking out unserviceable busbar supporting insulator For 630A to 800A Schneider make 11 KV VCB complete all as specified and as directed. Make :- Schneider only , Part No- MEP-39-A0147901
Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor For 630A to 800A Schneider make 11 KV VCB complete all as specified and as directed. Make :- Schneider only, Part No- ERC-A-A00DC-001
Supply and fix including dismantling taking out unserviceable Drive Beam suitable for 11 KV VCB 630A to 800A complete all as specified and as directed. Make :- Schneider only Model No MSM3950118600FN
Supply and fix Epoxy Body suitable for 11 KV VCB up to 630 Amps complete all as specified and as directed. Make :- Schneider only Model No MEP3953022000FN-22
Supply and fix including dismantling taking out unserviceable Shutter assembly for busbar / circuit spout suitable for 11 KV VCB up to 630A to 800A complete all as specified and directed. Make :- Schneider only Model No SPP0009-04
Supply only Busbar anodised aluminium off sizes including required drilling holes for fixing with other bus / cable connections all as specified and directed.
Supply only Busbar anodised copper off sizes including drilling holes for fixing with other bus / cable connections all as specified and directed.
M&L for finding of cable fault of UG 11000 volts grade cable inside trench (under soil / drain/PCC/road/trench ) by disconnecting both cable ends, using insulation tester, cable path/fault finder and rectification complete by necessary excuvation, cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 185 sqmm to 400 sqmm, 3 core, 11000 volts grade or replacement of heat shrink indoor cable joint kit of size 185 sqmm to 400 sqmm, 3 core and reconnection of both cable end to original position after complete satisfactory insulation test, fixing with old or required new nuts-bolts-washers complete with testing all as specified and directed . Note: (a) Items required for rectification such as heat shrink indoor cable joint kit / heat shrink straight through joints / heat shrink sleeves and earth work shall be measured separately . (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate. (c) Contractor shall bring necessary testing equipment and rate shall be inclusive of quoted rate.
Supply and fix cable route indicator to indicate path of HT cable 11000 Volte material usde cast iron with pcc work complete all as specified and directed.
Supply only cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm incl dismentling / taking down unserviceable one all as specified and directed.
Servicing/maintinance/painting of multiple section of LT Panel board in one substation comprising minimum up to 04 Nos ACBs/ MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray chamber after opening front/top/side/back cover by using forced air pressure and brushes, cleaning of all dust/durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tighting of all nuts & bolts of busbar/switchgear/cable terminals, repair/replacement to defective metering wiring from ACB/MCCB/CT to meter and replacement of defective meters, CTs, indicator lamp, metering terminal blocks, MCB, replacement of defective aluminum cable lugs, nuts-bolts-washers, replacement of defective Panel knob/door knob and hinges all as specified and directed for Note:- (i) Panel Meter, indicator lamp, MCB and CT will be measured and paid seperately as supply only. (ii) required aluminium cable lugs, metering cables and nuts-bolts-washers shall be inclusive of quoted rate. (iii) Servicing/maintinance of ACBs measured seperatelly.
All as per item No 45 above, but comprising ACBs /MCCBs/SDFs up to total 7 Nos
All as per item No 45 above, but comprising ACBs /MCCBs/SDFs up to total 21 Nos
All as per item No 45 above, but comprising ACBs /MCCBs/SDFs up to total 27 Nos
Servicing, repair, maintinance of Air Circuit Breaker 630 Amps to 3200 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and directed. Note: (a) Required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) All cleaning agents are included in the quoted rate.
Supply only fixed contact of ACB 630A to 3200A all as specified and directed.
Supply only Moving contact of ACB 630A to 3200A all as specified and directed.
Supply only Electronic protection unit of ACB 630A to 3200A all as specified and directed.
Supply only shunt trip coil of ACB 630A to 3200A all as specified and directed.
Supply only closing coil ACB 630A to 3200A all as specified and directed.
Supply only indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 240 V AC supply and taking down unserviceable indication lamps all as specified and directed. Make :- Cat Part No:-1SFA619402R5201 of Siemens/C&S/schneider/ABB
Supply only metering current transformer of 1000/5 Amps class-1, 15 VA, all as specified and directed. Make:-Rishabh, Cat No- TW-06 or equivelent of Kappa/ AE
M & L for Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical Plate No. 3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with RCC precast pit cover slab 80mm thick with handle for lifting made out of 8mm dia MS rod, Funnel with watering pipe, wiremesh, charcoal and salt in alternate 150mm thick layers around earth plate including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion after dismentling taking out unserviceable one complete all as specified and directed.
Supply and fix ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps all as specified and directed.
Supply and fix ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps all as specified and directed.
Supply and fix MCCB 3 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 36 KA all as specified and directed.
Supply and fix MCCB 3 Pole, 415 V, with Microprocessor release 250 Amps with breaking capacity 36 KA all as specified and directed.
Supply and fix MCCB 3 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA all as specified and directed.
Taking down old unsv copper /aluminium point wiring (light, fan.socket or power) complete including fixture and fittings such as switches,ceiling roses,pendants,regulators,sockets,light fittings etc removing materials to store for keepin or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of walls,floors etc. complete all as specified and directed.
Taking down old UNSV DB's and main switches along with MCBs and MCCBs all as directed.
M&L for point wirng concealed type in non-metallic FRLS ISI PVC conduit medium grade with 1.5 sq mm size multi stranded fire retardant PVC sheathed FRLS copper conductor cable and PVC insulated FRLS cable of size 1.5 sq mm as earth continuity conductor including clamps, screws gutter / plug etc with and including with bakelite 3 mm thick sheet : Note:Cutting chases for DB &making good to wall shall be inclusive of quoted rate
(a) One light point point controlled by one 5 Amps switch one way
(b) One fan point controlled by one 5 Amps switch one way
(c) One 3/5 pin 5 Amp switch socket outlet on independent board
(d) One 3/5 pin 5 Amp socket outlet on same board.
Supply & fix Switch piano, flush type single pole, one way 5 Amp all as specified and directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp in 1, 3 pin, 5 and 15 Amp flush type universal all as specified and directed.
M&L for point wiring concealed type in non mettalic FRLs ISI PVC conduit med grade with 2.5 sq mm size multi stranded FRLS PVC sheated copper conductor and PVC insulated FRLS copper cable of size 1.5 sq mm incl clamps, screws, gutties, plug, terminal boards with bakelite sheet 3 mm thick heavy duty as earth continuity conductor for 3/5 pin socket outlet 15 Amps all as specified and directed. Note:Cutting chases for DB &making good to wall shall be inclusive of quoted rate
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required all as specified and directed.
S&F SP MCB 6 to 32 Amps 'C' Curve complete all as specified and directed.
S&F TPN MCB 63 Amps C Curve complete all as specified and directed.
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way including dismantling taking down unsv one all as specified and directed.
S&F doubledoor TPN DB 6 way double door with 200 Amp rated bus bar all as specified and directed.
S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed.
M & L for wiring with 2 runs of 1.5 sqmm FRLS grade PVC insulated copper conductor wire single core multistrand for phase & neutral, 1.0 sqmm FRLS grade PVC insulated copper conductor wire for earch continuity drawn in and including non metallic FRLS ISI marked PVC conduit medium grade dia with conduit accessories ,all as specified and directed. Note:Cutting chases for DB &making good to wall shall be inclusive of quoted rate
M & L for wiring with 2 runs of 6 sqmm FRLS grade PVC insulated copper conductor wire single core multistrand for phase & neutral, 6 sqmm FRLS grade PVC insulated copper conductor wire for earch continuity drawn in and including non metallic FRLS ISI marked PVC conduit medium grade dia with conduit accessories ,all as specified and directed. Note:Cutting chases for DB &making good to wall shall be inclusive of quoted rate
M & L for wiring with 4 runs of 10 sqmm FRLS grade PVC insulated copper conductor wire single core multistrand for phase & neutral, 10 sqmm FRLS grade PVC insulated copper conductor wire for earch continuity drawn in and including non metallic FRLS ISI marked PVC conduit (heavy grade) with conduit accessories ,all as specified and directed. Note:Cutting chases for DB &making good to wall shall be inclusive of quoted rate
Taking down of Exaust fan upto 450 mm dia from wall, dismmanting complete fan assy, removing of motor and taking out for rewinding to civil workshop outside dockyard, complete rewinding with super enamelled copper wire as per existing size, heating, varnishing replacement of both end bearing and complete assemble of motor, transport been to ND(V), complete assemble of exhaust fan,fixing to orginal position, testing commisioning complete including painting to complete fan assy all as specified and directed.
M&L for servicing & rewinding of ceiling fan size upto 1400 mm sweep after opening complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings / capacitor pad / connector block, connection wire 3 core, assemble of rotor and stator unit with capacitor, connecting wire, capacitor pad, down rod, blades complete including painting to complete fan assy complete all as specifeid and directed.
S&F LED tube light fitting with LED tube, 4'long, 20 watt, CDL, 230 Volts , complete with all accssories internally pre wired incl dismantling taking down unsv FTL/CFL fiitings all as specified and directed.
Earth continuity conductor or main earthing lead 25x4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified and as directed
Taking down of wall mounted fan upto 450 mm dia from wall, dismmenting complete fan assy, removing of motor and taking out for rewinding to civil workshop outside dockyard, complete rewinding with super enamelled copper wire as per existing size, heating, varnishing replacement of both end bearing and complete assemble of motor, transport been to ND(V), complete assemble of exhaust fan,fixing to orginal position, testing commisioning complete including painting to complete fan assy complete all as specified and directed.
Supply and fixing aluminium strip 25mm x 3.15mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
Supply and fixing air termination , single pointed aluminium rod 12mm dia and 300mm long complete all as specfied and as directed.
Supply and fix test point terminal block made of gun metal or phorphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex Head screw complete all as specfied and as directed.
S&F LED high bay light 150 watt at roof truss level of wksp buildings and other places incl dismantling taking down unsv one any type all as specified and directed.
Supply, laying and connecting up through surface/wall/duct cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with straded aluminium conductor of size 95 sqmm 3.5 core all as specified and directed.
Supply, laying and connecting up through surface/wall/duct cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with straded aluminium conductor of size 240 sqmm 3.5 core all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft loose soil for cable work or from above cable duct complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for dry sand cushioning for under ground cable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180mm x 40mm all as specified and directed.
Surface dressing of areas of above cable duct by Clearing away all grass, wild vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30cm girth and removing rubbish upto a distance of 50 meters outside the periphery of the area under clearance complete all as specified and as directed.
Dismantling existing unserviceable /corroded LT Pillar Box and supply, fabricate, install, testing and commissioning out-door type, double door dust & vermin proof LT piller box of 2.1 M length, 1 M width & 1.6 M height fabricated vertically by using 50x50x5 mm angle iron frame, fixing with nuts & bolts on 75 x 40 mm ISMC as per directions of Engineer-in-Charge and using 3 mm thick CRCA MS sheet all over body front and back cover with hinges and aldrops for locking arrangments, 1 mm thick FRP coating all over the external surfaces and 3 mm thick MS sheet for bus bar cover, piller Box, partitions and bottom cable entry covers duly painted with one coat of redoxide and two coats of synthetic enamel paint including control wiring complete in LT piller box with 1.5 sq mm FRLS copper conductor cable and 5A MCB SPs 2.5 amp for meters, breaker control supply and indication lamps and provision to accommodate the following: (a) 3 ph+1N Copper busbar of equal sizes of capacity 1.5 times of rated current of incoming switchgear. (b) 3 ph+1N Copper busbar of equal sizes of capacity 1.5 times of rated current of outgoing switchgears as down links/connectivity links to switchgear.
(c) Digital ammeter & voltmeter for incoming & Digital ammeter for outgoing. (d) LED indication lamps for RYB for incoming and outgoing indication.(Red,yellow & blue coloured) (e) LT ACB – 630Amps, 4P, 50KA, complete with over current and earth fault tripping device as incomer -01No (g) MCCB - 400 Amps, 3P, 36KA complete with over current and earth fault tripping device as out going-02No (h) MCCB - 250 Amps, 3P, 36KA complete with over current and earth fault tripping device as outgoing-01No Note : (i) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC (1:2:4) type B1 using 20 mm graded crushed stone agreegate for foundation to fix the LT Piller Box. (ii) Cost of digital ammeter, voltmeter, LED lamps, CTs, LT ACBs, MCCBs and MCBs shall be included in the quoted rate. (iii) Drawing shall be got approved by GE before fabrication of the LT piller Box. (iv) All incoming and outgoing cable connections are to be made as per existing one and rate deemeded to be included in the quoted rate. (v) The pillar box shall be brought to Jetty gallery part by part and to be assembled in site being limited space of work/movement and rate shall deemed to be included in quoted rate. (vi) Copper busbars with pvc sleeves shall be measured and paid seperately under respective item in this schedule as 'Supply only'
aswitha engineering works
SANTOSH CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .