Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.8 L+₹31,200.50 (3.28%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.0 L+₹48,580.50 (5.11%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹11.6 L+₹2.1 L (21.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | Rejected-Technical TENDER DOCUMENTS DO NOT CONTAIN THE FULL ADDRESS FOR THIS PRIVATE COMPANY | - | Rejected-Technical Documentary evidence in proof of experience submitted is not as per NIT terms |
Tender Value
₹10 L
EMD Value
₹25,000
Closing Date
17 Apr 2024, 2:00 pmClosed
Dairy Manager
Milam Palakkad Dairy, Kallepully, Palakkad
COLD ROOFING WORK OF QUALITY ASSURANCE LAB AT MILMA PALAKKAD DAIRY
2024_KCMMF_652621_3
01/PKD/ENGG/CIVIL/LAB ROOFING/2023-24
Open Tender
Civil Works - Buildings
Item Wise
45 days
Milma Palakkad Dairy, Kallepully
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
Yes
₹25,000
3 Sept 2024
5 Apr 2024
18 Apr 2024
5 Apr 2024
17 Apr 2024
5 Apr 2024
Amount
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.
Providing and laying in position reinforced cement concrete for reinforced cement concrete work of mix 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size), but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All works above plinth level
Centering and shuttering including strutting, etc. and removal of form above plinth level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Thermo - Mechanically Treated bars of grade Fe-500 or more
Steel work in single or built up sections, base plates, trusses, frame work, purlins, wind tie etc., including cutting, welding, bolting, hoisting, fixing position and applying two coat approved steel primer and two coat enamel paint, etc. complete.
Steel work in single or built up M.S tubular (round, square or rectangular hollow tubes etc.) trusses, frame work, purlins, wind tie etc., including cutting, welding, bolting, hoisting, fixing position and applying two coat approved steel primer and two coat enamel paint, etc. complete.
Providing and fixing MS round holding down bolts/anchor bolts\foundation bolts etc of specified size and diameter with nuts, washer complete as per the direction of Engineer in charge
Providing and fixing Sandwiched roofing panel made of 9-10mm thick XLPE/PUF having density of 30-35 kg/m3 sandwiched between 0.40mm (+-0.05%) TCT PPGL sheet with Al-Zn coating 150gsm in upper skin and PPGL/Aluminium sheet in lower skin. Steel sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sheet shall be fixed using self drilling/self tapping screws applied only on ribs of the sheet with EPDM seal, complete upto any pitch in horizontal/ vertical, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvalume sheets (PPGL) (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.45 mm (+ 0.05%) total coated thickness, Al-Zn coating 150 grams per sqm Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvalume sheet (PPGL) ridge 0.45 mm (+ 0.05%) total coated thickness, Al-Zn coating 150 grams per sqm self drilling/self tapping screws complete:
Providing and fixing Square UPVC gutter of minimum 160mm wide and 100mm depth including fittings, drop, clamp etc. complete.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/ clips/ at 1.00 m spacing. This includes jointing of pipes and fittings with one step PVC solvent cement and testing of jointscomplete as per direction of Engineer-in-Charge 110mm dia 4 Kgf/cm2 - Exposed on wall/slab
SIVANANDAN MANIKYAN
MEGHA MOHAN M
Nijesh
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .