| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹45.3 L+₹3.8 L (9.21%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹45.6 L+₹4.0 L (9.75%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹45.6 L+₹4.1 L (9.90%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹45.8 L+₹4.3 L (10.3%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
9 Jan 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVISION OF GEYSER AND RO PURIFIER AT NEWLY CONSTRUCTED MD ACCN AT ICGS VADINAR UNDER GE I CG PORBANDAR
2022_MES_570250_1
8826
Open Tender
Civil Works
Item Rate
180 days
VADINAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹80,000
Yes
7 Feb 2023
20 Dec 2022
10 Jan 2023
20 Dec 2022
9 Jan 2023
3 Jan 2023
Amount
SCHEDULE 'A'
Supply and fix electric water heater, storage type with inner tank and heating element upto 2 KW, BEE 4 star and above rated complete with all accessories such as safety valve, thermostate, NRV, with Anchor fastners of suitable size and including Flexible hot/cold connection Pipe -02 Nos, complete all as specified and directed of follwing capacity:- Make - JAQUAR Model. ELENA MANUAL/ Racold Model. Andris Uno /AOSmith Model. Finesse.
(a) 10 Litre Capacity
(b) 15 Litre Capacity Note: (a) Geyser to be fitted by company technician only. (b) Geyse fixing to be done only by heavy fastners. (c) Warranty card of every New Geyser will be submittedto the Engineer-in-charge duly stamped.
S&F Domestic type RO water purifier fully automatic operation with auto start and auto off secondary purification by UF after RO ensuring enhanced water quality through out service cycles and with TDS control system enabling maintaining of essential natural minerals in purified water, spin welded RO membrance housing to prevent tampering built in SMPS to operate with 160-250 V leak proof ABS construction for corrosion free life span suitable for all type of RAW water like borewell, shallow well, overhead storage tanks, water tankers all as specified and directed with following specification:-
(i) Prefilter with connected accessories-01 No
(ii) Purification capacity -15 ltrs/hour
(iii) Max duty cycle -75 ltrs/day
(iv) Storage tank capacity - 8 ltrs
(v) RO membrane - 1812-75 GPD
(vi) UF membrance - 0.01 micron
(vii) Min inlet water pressure - 0.3 kg/cm2
(viii) Input voltage - 160-250 V DC
(ix) Operation voltage -24 V DC
(x) Dimension : L-340mm W-265mm H-505mm
(xi) Net Weight - 6.5 Kg
Make:- Kent RO (Elegant Lite)
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded Flame retardant PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets all a specified and directed Make of wire: Polycab/Finolex/RR Kabel
Supply and fix Marut Air Powerful Exhaust Fans MCG-900 Model MCG-900 Diameter blades (mm) 900 blades rotational speed (r/min) 620 Air flow (m³/h) 30,000 Noise (decibels) <70 Import power (W) 750 Rated voltage (V) 415 HeightxWidthxThickness 1000mmx1000mmx400mm complete all as specified and as directed.
S&F Modular switch 16 A, 1 way, 1 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider
S&F Modular socket 6/16 A, 2/3 pin combined , 2 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider
Cutting of mirror window & making hole of size 1030mm x 1030mm for fixing of Air powerfu exhaust fan complete as directed.
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor of size 35 sqmm 3.5 core, 1100 volts grade of cross-sectional area complete all as specified and directed by Engr-in-Charge. Make: Polycab/ Asian/ Gloster,
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor of size 25 sqmm 4 core, 1100 volts grade of cross-sectional area. Make: Polycab/ Asian/ Gloster, complete all as specified and directed by Engr-in-Charge.
Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 40 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. Make: Gemini/Rex/Poly
Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 32 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. Make: Gemini/Rex/Poly
S&F AC Three Phase Static Energy meter of Accuracy Class 1.0, 3 X 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh,V,I,kW,PF,Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete all as spd and directed. Make: HPL/L&T/Secure
Supply and laying speaker cable 2.5 sqmm (transparent) complete all as specified and directed
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Hard/ dense soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
roxy enterprise
JAMNAGAR ELECTRIC AND MACHINERY CO
SURAJ ENTERPRISE
jitendra c joisar
SURESH ELECTRICALS
OM ENGINEERING
RAJESH ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .