Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.5 L+₹26,815 (1.15%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹23.8 L+₹52,890 (2.27%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to not fulfiling Cat C(i) | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to not fulfiling Cat C(i) |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
18 Mar 2020, 6:00 pmClosed
Lt Col Amit Bhat
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
SPECIAL REPAIR TO E/M ITEMS DECLARED BER IN THE BOO FOR ITEMS AT AF STATION JAMNAGAR
2020_MES_328718_1
8721/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR NO.1
₹61,000
Yes
21 Apr 2020
26 Feb 2020
19 Mar 2020
26 Feb 2020
18 Mar 2020
11 Mar 2020
Amount
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (15 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:- (i) Refrigerant - R 410a (non CFC) (ii) EER - min 3.5 w/w( 3 star rating) (iii) Tonnage -1.5 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter
(vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: Carrier/ Hitachi/O General
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (15 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:- (i) Refrigerant - R 410a (non CFC) (ii) EER - min 3.5 w/w( 3 star rating) (iii) Tonnage -2.0 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter
(vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make- Carrier/Hitachi/ O General
Note for item No. 1 & 2 Following will be inclusive in rate:- (a) Piping length up to 15 mtr will be inclusive in item
(b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge (c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe
(d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) Contractor will provide warranty of 5 years for compressor from the date of installation (f) 5% of Air conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air conditioner (g) Contractor shall provide complete free service in warranty period by the company
Supply & installation of Air cooled inverter based cassette type split AC unit with cooling functions and suitable at ambient for outdoor unit 15 to 46 Deg C in cooling mode . Cassette type Air Conditioner will have following conditions :- (i) Airflow Rate- 33/28/22.5 m3/min, 1165/988/794 cfm (ii) Piping Connection (Liquid/Gas/Drain)- 9.52/15.88/26 (Hole) mm (iii) Outdoor Unit Sound Level- 55 dB(A) (Cooling) (iv)Max Interunit Piping Length- 50
(v) Power Supply (1-Phase) 230 V, (3-Phase) 400 V, 50 Hz (vi) Indoor Unit Model FCVF140BRV16 (1-Phase, 3-Phase) (vii) Outdoor Unit Compressor- Hermetically sealed swing Type, 2.4 kW (Motor Output) (viii) Outdoor Unit Refrigerant Charge- 3.1 kg (Charged for 30 m) R-32(Non CFC)
(ix)Outdoor Unit Dimensions- HxWxD 990x940x320 mm (x) Outdoor Unit Machine Weight- 69 kg (xi) Outdoor Unit Certified Operating Range-21 to 46 Degree C (DB) (xii)Maximum Installation Level Difference-30 m (xiii)Outdoor Unit Model -RZVF140BRY16 (3-Phase)
(xiv)Cooling Capacity Rated -14.0 (6.2~15.5) kW (xv)Power Consumption Rated- 5.900 kW (1-Phase), 5.500 kW (3-Phase) (xvi)Indoor Unit Colour- Fresh White (xvii)Indoor Unit Dimensions- HxWxD 298x840x840 mm (Unit), 50x950x950 mm (Panel) (xviii)Indoor Unit Machine Weight- 24 kg (Unit), 5.5 kg (Panel) (xix)Indoor Unit Certified Operation Range-14 to 28 Degree C (WB) .
(xx) Contractor will provide warranty of 5 year for compressor from the date of installation . (xxi) 5% Air Conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air Conditioner. (xxii) After installation , service of Air Conditioner company shall be included upto one (01) year without any cost . Make- Daikin or equivalent make of Carrier/Hitachi/O General
Taking down existing cassette type split Air Conditioner any capacity inner and outer both units and depositing to MES store complete all as specified and directed by engineer incharge.
Taking down POP false ceiling for removing of existing Cassette AC indoor unit & making good after fitting of new Air conditioners to match the existing surface all as directed and as per site requirement.
Supply and fix MCB TPN ,C curve,20 Amp, 10KA fitted in and including suitable size of SMC box complete all as specified and as site requirement . Make-ABB/HAVELLS/LEGRAND
Supply & Fix voltage stabilizer with digital type voltmeter for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 4 KVA. Make :- V Guard/SUKAM/Microtek
Supply & Fix voltage stabilizer with digital type voltmeter for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 5 KVA. Make :- V Guard/SUKAM/Microtek
Supply & install smart inverter compressor based refrigerator electric driven (single phase) double door of capacity 300 to 325 Ltr, Energy rating 5 star Non CFC, frost free and energy efficient compressor that save energy upto 36% including PCC foundation 1:2:4, 60 cm above the ground with plaster complete all as specified and as directed. Make-LG/GODREJ/WHIRLPOOL
Supply & install smart inverter compressor based refrigerator electric driven (single phase) single door of capacity 190 Ltr, Energy rating 5 star Non CFC, frost free and energy efficient compressor that save energy upto 36% including PCC foundation 1:2:4, 60 cm above the ground with plaster complete all as specified and as directed. Make-LG/GODREJ/WHIRLPOOL
Supply only bottled water dispenser , having option of dispensing hot and cold water of following size and specification :- (a) Make : Voltas or equivalent in Blue star, Daikin etc. (b) Model No. Minimagic Pure R (c ) Type :- Floor Mounted (d) Cabinet type :- Cooling cabinet (e) Power supply :- 230V-50 Hz (f) No of Faucets :- 3 Nos (g) Cold water storage Capacity :- 3.0 Ltr (h) Cooling capacity :- 2.5 ltr/Hr (j) Cooling power consumption :-86W (k) Hot water storage Capacity :- 1 Ltr
(l) Heating Capacity :- 5 Ltr/Hr (m) Heating power consumption :- 500 W (n) Unit dimension :- 310x345x940 mm (o) Refrigerant :- Non CFC (R 134a) (p) Compressor cooling :-Yes (q) Function :- Hot, Normal , Cold (r) Display :- LED indicator (s) Hot water dispenser lock :- Yes
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 4 Sqmm drawn through in and including Non metallic PVC casing capping on wall / ceiling with all accessories with 4.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note: Three runs of 4.0 sqmm copper cable including PVC casing capping will be measured as one RM for payment.
S & F in repair metal clad plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete. Make : Havells/C&S/L&T
Jyoti Refrigeration
M/s SK Traders
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .