Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR MAINT OF CEILING FANS EXHAUST FANS AIR CIRCULATORS WALL FANS FLAME PROOF FANS SAFETY CHECK OF CEILING FANS ETC AT MOV NEW OLD BVY SRU WED RS 32 WEU NSB CTW NSV CE N INS VISWAKARMA NAMAC ASHOKA PARK MEGHADRIPETA PALLAVA PARK ADJ AREA GE ND V
2026_MES_773215_1
8623/GEND/E8
Open Tender
Electrical and Maintenance Works
180 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Naval Depot
₹70,000
Yes
23 Jun 2026
23 Jun 2026
16 Jul 2026
23 Jun 2026
14 Jul 2026
7 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.01 | SCHEDULE 'A' PART-I: E/M WORKS | - | - | - | - |
| 1 | Taking down carefully ceiling fans at any height 3.5mtr from the floor of any sweep/ make / model after disconnecting the electric connections and dismantling , cleaning the complete body and renewal of split pins , cater pins , coupling bolts, terminal adaptors, screws, nut sspring washers for blade/body etc and replacement of components/ accessories such as ball bearings, gun metal bushes, capacitor , canopy, shackle pins assembly and assembling all parts incl hanging and fixing in the same position and connecting back the electrical connections and testing for its safety ,satisfactory performance complete all as specified and as dirtcected NOTE (i) Spare parts will be measured and paid separately under relavent items of schedule under supply only (ii) rewinidng of the fans motors, painting will be measured and paid separately (iii) Labour element for fixing of spares parts and removing old unserviceable items are deemed to be incl in quoted rate (iv) Material, arrangements for safety tools and items required to work at heights is deemed to be included in the rates quoted. Each complaint to be supported with the job card of the under format and the rates quoted are deemed to be incl of necessary stationery chargers | 2,350 | EACH JOB | 1.25 | ₹2,937.5 |
| 1.01 | JOB CARD FORMAT (i) sl No (ii) Area (iii) Particular location (iv) No of ceiling fan tested for safety with weight upto 75 kg applied (v) Sig of Contractor's rep with date (vi) Sig of the Occupant with date (vii) Signature of AO/WO of the Area with date (viii) Signature of JE(E&M) with date (ix) Remarks | - | - | - | - |
| 2Takingdown carefully ceiling fans at any height more than 3.5 mtr from the floor of any sweep/ make / model after disconnecting the electric connections and dismantling , cleaning the complete body and renewal of split pins , caterpins, cater pins , coupling bolts, terminal adaptors, screws, nut sspring washers for blade/body etc and replacement of components/ accessories such as ball bearings, gun metal bushers, capacitor , canopy, shackle pins assembly and assembling all parts incl hanging and fixing in the same position and connecting back the electrical connections and testins for its safety satisfactory performance complete all as specified and as dirtcected NOTE (i) Spare parts will be measured and paid separately under relavent items of schedule under supply only (ii) rewinidng of the fans motors, painting will be measured and paid separately (iii) Labour element for fixing of spares parts and removing old unserviceable items are deemed to be incl in quoted rate (iv) Material, arrangements for safety tools and items required to work at heights is deemed to be included in the rates quoted. Each complaint to be supported with the job card of the above format and the rates quoted are deemed to be incl of necessary stationery chargers (FORMAT AS PER ITEM ABOVE) | |||||
| 3 | All as per item 1 above but for Exhaust fan Metal body 300 mm sweep to 450mm sweep complete all as specified and as directed (FORMAT AS PER ITEM ABOVE) | - | Each Job | 100 | - |
| 4 | All as per item 1 above but for Exhaust fan Metal body 600 sweep complete all as specified and as directed(Note : that the work to be carried out at heights of 10-15 mtrs from the GL and rates quoted to be incl of hiring of heavy duty manupulator suitable for the mentioned ht and ensuring safety of the workers working at that ht. The workers should be covered with suitable inusrancy policy by the tenderer and this will deptt will not be liable for any accident while repairing/ replacing the fans and rates quoted are deemed to inclu of all the rates ) (FORMAT AS PER ITEM ABOVE) | - | Each Job | 53 | - |
| 5 | All as per item 1 above but for Exhaust fan PVC Body200 to 250mm sweep complete all as specified and as directed (FORMAT AS PER ITEM ABOVE) | - | Each Job | 10 | - |
| 6 | All as per item 1 above but for Exhaust fan PVC Body 300mm sweep complete all as specified and as directed (FORMAT AS PER ITEM ABOVE) | - | Each Job | 11 | - |
| 7 | All as per item 1 above but for Air Circulators/ wall mounted fans of 450mm to 600mm sweep complete all as specified and as directed (FORMAT AS PER ITEM ABOVE) | - | Each Job | 1.25 | - |
| 8All as per item 1 above but for flameproof exhaust fans 450mm to 600mm sweep complete all as specified and as directed(Note : that the work to be carried out at heights of 10-15 mtrs from the GL and rates quoted to be incl of hiring of heavy duty manupulator suitable for the mentioned ht and ensuring safety of the workers working at that ht. The workers should be covered with suitable inusrancy policy by the tenderer and this will deptt will not be liable for any accident while repairing/ replacing the exhuast fans and rates quoted are deemed to inclu of the same) (FORMAT AS PER ITEM ABOVE) | |||||