Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 CrAccepted-AOC | ₹6.0 Cr | L1 | Accepted-AOC L1 being lowest bidder |
| 2 | L2₹6.0 Cr+₹2.0 L (0.33%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹6.0 Cr+₹2.0 L (0.33%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹6.0 Cr+₹2.6 L (0.44%)Rejected-Finance | ₹6.0 Cr+₹2.6 L (0.44%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹6.3 Cr+₹35.0 L (5.87%)Rejected-Finance | ₹6.3 Cr+₹35.0 L (5.87%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹6.4 Cr+₹39.0 L (6.54%)Rejected-Finance | ₹6.4 Cr+₹39.0 L (6.54%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹5.8 Cr
EMD Value
₹6.1 L
Closing Date
23 May 2025, 6:00 pmClosed
CHIEF ENGINEER PATHANKOT ZONE
HQ CHIEF ENGINEER PATHANKOT ZONE
PROVISION OF OTM ACCN PH-I AT MILITARY STATION SAMBA
2025_MES_698638_1
CEPZ-14/2024-25
Open Tender
Civil Works
Lump-sum
660 days
SAMBA
as per tender documents
8 documents required · 8 mandatory
₹3,000
SAMBA
₹6.1 L
Yes
16 Jul 2025
20 Feb 2025
30 May 2025
20 Feb 2025
23 May 2025
9 May 2025
Amount
Lumpsum price worked out by the contractor for Buildings works as listed in Schedule 'A' Part-I
Lumpsum price worked out by the contrator for Earth Work, Site Clearance & Site Development as listed in Schedule 'A' Part-II
Lumpsum price worked out by the contractor for Internal Water Supply Works listed in Schedule 'A' Part-III
Lumpsum price worked out by the contractor for Internal Electrification Supply Works listed in Schedule 'A' Part-IV
Lumpsum price worked out by the contractor for Protective Works listed in Schedule 'A' Part-V
Lumpsum price worked out by the contractor for Road, Path & Culvert as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Sewage Disposal works as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Area Drainage Works as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for Summer Appliances Works as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for Hot Water Supply Works as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for External Water Supply as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the contractor for External Electrification works as listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the contractor for Demolition and Dismantling of Building Works as listed in Schedule 'A' Part-XIII.
M&L for RCC Septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls. Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole opening with cover connection etc. complete with effective depth of 1.5 Metre and overall depth of 3 metre for 100 Users with UPFLOW FILTER complete all as specified and shown on relevant drawings and as directed and directed.
M&L Soakage well of size 3.0 M dia x 3.0 M deep, excavation in ordinary soil foundation on PCC 1:3:6 walls of honeycombed and soil in M 25 concrete includiong intercepting chambers, screen chamber, brick work in CM. RCC cover slab in M25/RR masonry/filling with brick bats complete all as specified and shown on relevant drawings and as directed.
M&L for Sheet metal enclosures distribution boards, double door VTPN, 415 volts 4 way suitable for fixing MCCB as incomer and MCBs as out going (One incoming three phase & eight outgoings single phase) for MCCB & MCBs comprising three phase four wire copper strip bus bar of appropriatee capacity complete all as specified and directed. Note: (i) The DB shall be VTPN series. (ii) The DB shall be flush fixed and making good the distrubed surface matching with existing specifications shall be part of work at no extra cost. (iii) Connection of the MCCBs and MCBs with cable shall be made through appropriate size pin/bottle type thimble properly crimped. (iv) All the size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) MCCB and MCB shall be measured and paid separately under respective items.
M&L for Earthing with galvanished steel earth plate electrode 600x600x 6.0mm thick buried directly in ground pit not less than 3.25 mtr deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to 4.00 mm dia GI wire & PVC insulated solid copper conductor of size 4 mm by means of nuts and GI washers including PCC pit in PCC 1:2:4 type B-1, RCC cover, 20 mm dia (MG) GI watering pipe with funnel wire mesh and protection pipe of GI of 15 mm dia up to 7.5 Mtr length including charcoal, salt, excavation earth work etc in any type of soil complete all as shown in electrical plate No 3 of MES SSR PART-1 as specified GI wire & 4 MM dia solid conductor pvc insulated for continuity earth wire from test point to main distribution board and all as specified and as directed. Note:- Rate for archieving requierd depth by compressor machine if required is deemed to be included in the quoted unit rate.
Supply and Fix LED bulb 12 watt invertor type base type B-22 lumen output 1200. 6500 K complete all as specified and directed by Engr-in-Charge.
Supply, Installation testing and commissioning of heavy Duty Package Air Cooling Units, Top/Down (Universal) Discharge with following features 4” inch thick imported high efficiency cellulose pads on 4 sides, optimized 3 Phase motor and fan to deliver the powerful air flow, water pump in wet section, cool flow dispenser for better cooling, auto connection of water tank to quick fill, water connection with ball valve , drain and overflow connection, weather resistat engineering plastic body with dust filter comprising of following Capacity Complete. Note: (i) The contractor should provide ducting layout drawing and cooling unit technial drawing and data to the department for approval. (ii) The Package Air cooler installed at G + 2 building and required T & P for positioning the four nos of plant in top of the roof deemed to be included on the quoted rate” (i) Ground Floor Wing A 7000 CFM (2.2 Kwh Three Phase) -Each-01. (ii) Ground Floor Wing B 7000 CFM (2.2 Kwh Three Phase) – Each-1. (iii) First Floor Wing A 12000 CFM (3.5 Kwh Three Phase) -Each -01 . (iv) First Floor Wing B 12000 CFM (3.5 Kwh Three Phase)- Each- 01. (v) Second Floor Wing A 12000 CFM (3.5 Kwh Three Phase) – Each-01 No. (vi) Second Floor Wing B 12000 CFM (3.5 Kwh Three Phase) – Each-01 No
Supply, Installation, Testing and commissioning of flexible connection with material Canvass all as specified and directed by Engr-in-Charge.
Supply, Installation, Testing and commissioning of Factory Fabricated GI Sheet Spiral Oval/Round Ducting with required Hardware Sheet 22 Gauge complete all as specified and directed by Engr-in-Charge.
Supply, Installation, Testing and commissioning of Factory Fabricated GI Sheet Spiral Oval/Round Ducting with required Hardware Sheet 24 Gauge all as specified and directed By Engr-in-Charge
Supply and application of Acoustic treatment of ducts with 15 mm thick open cell, elastomeric nitrile rubber, of 140 Kg/m3 density dust free, fiber free, and CFC free insulation pasted inside the Duct with the help of adhesive complete all as specified and directed by Engr-in-Charge
Supply Installation, Testing and commissioning of Thermal Duct insulation with 6 mm thick aluminium foil faced XLPE pasted on duct with rubber adhesive complete all as specified and directed by Engr-in-Charge.
Supply Installation, Testing and commissioning of air aluminium powder coated linear Grill / Diffusers with M. S volumn control duct damper all as specified and directed by Engr-in-Charge.
Supply Installation, Testing and commissioning of Site Fabricated MS Angle Iron stand for Ductable Air cooling Unit with black enamel paint including lifting and placing of air washers all as specified and directed by Engr-in-Charge.
Supply Installation, Testing and commissioning of 2.5 Sq mm x 4 core Copper cable all as specified and directed by Engr-in-Charge.
Supply Installation, Testing and commissioning of water connection with 2000 Ltrs tank & required accessories for evaporating ductable air cooling unit all as specified and directed by Engr-in-Charge.
Supply Installation, Testing and commissioning of voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for in put variation between 90 v to 280 v with output volatge stablizer at 230 v with acciracy of (-) or (+) 2.5% and of capacity 2 Kva including all connection complete all as specified and directed by Engr-in-Charge.
M&L for Cutting of existing DI pipe two cut of dia 150mm position for intersection of new MS sec of 150 x 100 x 100mm dia tee for branch connection complete with all fittings complete all as specified and directed by Engr-in-Charge. Note:- DI fitting, excavation and earth work, lead joint/Flanged joint etc shall be measured and paid separately under relevant items
M&L for Construction of brick masonry valve chamber of internal dimensions 900 x 900 x 900 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregates, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15mm thick. The top cover of the pit shall be out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 nos steel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Supply and Fix release valve of 40 mm dia with two air outlets and fixing up in Gi water supply mains complete all as specified and directed.
M&L for Pole mounting junction box of size 300mmx200mmx100mm fabricated out of 2mm thick MS sheet, front openable door with hinges, weather proof duly painted with two coats of aluminium paint internally and externally over a coat red oxide primer suitable to house and including 04 Nos aluminium bus bar of 63 Amps capacity mounted on suitable insulators, one No MCB SP 6A mounted on dinrail, internally wired with suitable size of copper conductor cable, provision of bottom cable entry with cable glands including mounting on steel tubular poles with two Nos F.I. clamps 25mmx3mm with nuts, bolts and washers complete including making connection with 1.5 sqmm copper conductor PVC insulated 3 Core cable from junction box to security lights fittings duly laid inside the steel tubular pole and bracket complete all as specified and directed.
M&L for Bracket fixing for street /building light fittings bend to shape, made out of 40 mm dia GI pipe medium grade upto 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50mmx6mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed. Note : MS clamps including nuts, bolts and washers shall be measured and paid for separately under respective items.
Supply ,Installation ,testing & commisioning of totally enclosed feeder piller box outdoor type (IP-65) fabricated out of 3.15 mm thick CRCA sheet angled framed dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt 50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips made out of 65x65x6mm angle iron grouted in brick masonry plateform upto 30 cms .Brick masonry plateform should be 60 cms above the Ground Level comprising the following :- (i) The panel shall be front operated with cable entry from the bottam with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI. Width of the panel should not be less than 60cms Main LT Panel No 01 ( Pocket -I, Ph-I) Aluminium bus bar electrolytic grade rectangular 300 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves - 01 job (a) MCCB 160 amps , 25 KA ,FP, 415 volt 50 Hz adjustable type-01 No's (for Incoming)
M&L for Construction of platform of size 3000 x 2500 x 1200 mm for transformer with PCC (1:4:8) in foundation and PCC 1:2:4 type B1, 100 mm thickness at top portion of platform , brick work with cement mortar (1:4) and complete plaster work of 15 mm thick to exposed surface in CM (1:4) including necessary MS work ( i.e. MS jali/fencing/MS angle ) on the top of platform around transformer up to height 90 cm and one coat of white wash on plastered surface complete all as shown on drawing No CEPZ/C-TD/002/13 Dated 2/5 and all as specified .
Supply and laying 3 layer PP-R Polypropylene random copolymer concealed pipes of size 32 mm SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors connected on water tank to air cooling unit and motors complete all as specified and directed by Engr-in-Charge.
Supply and fix PP-R Gate valves (brass inserted) of size 32 mm dia to connect the PP-R pipe complete, all as specified and directed by Engr-in-Charge.
M & L for Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 20 Amps complete all as specified and directed by Engr-in-Charge.
Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 40,997.00 shall be deducted from the total amount of BOQ to arrive at the contract sum.
vijay builders (BID ID -3298501)
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd. (BID ID -3297793)
M/S MOHAN LAL GUPTA (BID ID -3298483)
Elite Builders (BID ID -3302756)
M/S ARUN ANAND (BID ID -3298225)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .